Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESTRAINTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Evaluation of Factors Affecting Powdered Drug Reconstitution in Microgravity

Owing to the high cost of transporting mass into space, and the small volume available for equipment in the Space Shuttle Orbiter and the International Space Station, refrigeration space is extremely limited. For this reason, there exists strong motivation for transporting certain drugs in powdered form so that they do not require refrigeration. When needed, the powdered drug will be mixed with saline to obtain a liquid form that may be injected intravenously. While this is a relatively simple task in a 1-G environment, there are some difficulties that may be encountered in 0-G. In non-accelerated spaceflight, gravitational and inertial forces are eliminated allowing other smaller forces, such as capillary forces and surface tension, to dominate the behavior of fluids. For instance, water slowly ejected from a straw will tend to form a sphere, while fluid in a container will tend to wet the inside surface forming a highly rounded meniscus. Initial attempts at mixing powdered drugs with saline in microgravity have shown a tendency toward forming foamy emulsions instead of the desired homogeneous solution. The predominance of adhesive forces between the drug particles and the interface tensions at the gas/liquid and solid/liquid interfaces drastically reduce the rate of deaggregation of the drug powder and also reduce the rate of absorption of saline by the powder mass. In addition, the capillary forces cause the saline to wet the inside of the container, thus trapping air bubbles within the liquid. The rate of dissolution of a powder drug is directly proportional to the amount of surface area of the solid that is exposed to liquid solvent. The surface area of drug that is in contact with the liquid is greatly reduced in microgravity and, as a result, the dissolution rate is reduced as well. The KC-135 research described here was aimed at evaluating the extent to which it is possible to perform drug reconstitution in the weightlessness of parabolic flight using standard pharmacological supplies. The experiment included a parametric assessment of possible factors affecting the reconstitution process. The specific questions that we wished to answer were: (1) Is it possible to reconstitute powdered drugs in weightlessness using standard pharmacological equipment? (2) What are the differences between drug reconstitution in a 1-G and a 0-G environment? (3) What techniques of mixing the drug powder and diluent are more successful? (4) What physical and chemical factors play a role in determining the success of mixing and dissolution? (5) Is it necessary to employ crewmember and equipment restraints during the reconstitution process?

Schaffner, Grant↗

Medical Operation KC-135 Familiarization Flight

As new personnel join the Medical Operations Branch, it is critical that they understand the effects of microgravity on medical procedures, hardware, and supplies. The familiarization flight provided new personnel with a better understanding of the effects of microgravity on (1) medical procedures, (2) patient and rescuer restraint, (3) medical fluids, and (4) medical training for space flight. The flight process also provided experience in flight proposal preparation, flight test plan preparation and execution, and final report preparation. In addition, first time flyers gained insight on their performance level in microgravity for future flights.

Dawson, Chris↗

Plasma Hormone Concentrations in Monkeys after Spaceflight

The aim of this study was to determine the effects of a 12.5 day spaceflight on the endocrine status of Rhesus monkeys. Male monkeys (three to four years old; 4 kg) were adapted to chair restraint and trained for 20 months. Blood samples were obtained from four control (C) and two flight (F) monkeys preflight (PF), post-flight (Recovery-R; days 0, 3, 11, and 17), and before and after a mission length simulation (S). Cortisol, T4, T3, testosterone (T), and IGF-1 were measured by RIA (radioimmunassay). Growth hormone (GH) was measured by an in vitro bioassay. Cortisol (16-34 ug/dl), T4 (3.9-7.4 ug/dl), and T (0.2-0.4 mg/ml) did not differ between F and C or between PF, R, and S samples. The low T values reflect the immaturity of the animals. In F, T3 fell from C levels of 208 +/- 4 ng/dl to 44 on R+0 and 150 on R+3, then returned to C. F showed a 55% decrease in GH at R+0 and decreases of 93, 89, and 80%, respectively, at R+3, 11, and 17. IGF-1 decreased from PF levels of 675 ng/ml to 365 (R+0) and 243 (R+3), but returned to C at R+11. GH and IGF-1 levels before and after S did not differ from each other or from C. The cause of the transitory decrease in T3 is unknown. The suppressed GH levels for 17 days after flight may reflect reduced proprioceptive input during flight. The faster recovery of IGF-1 suggests that factors other than reduced GH secretion are involved.

Grindeland, Richard E.↗

Microgravity Investigation of Crew Reactions in 0-G (MICR0-G): Ground-Based Development Effort

This report describes the technology development of an advanced load sensor ground-based prototype and details the preliminary tests in microgravity during parabolic flights. The research effort is entitled, the Microgravity Investigation and Crew Reactions in 0-G (MICR0-G), a ground-based research effort funded by the National Aeronautics and Space Administration (NASA). The MICR0-G project was a follow-on to the Enhanced Dynamic Load Sensors (EDLS) spaceflight experiment flown on the Russian Space Station Mir. The technology development of the advanced load sensor prototype has been carried out by the Massachusetts Institute of Technology (MIT), with collaboration from Politecnico di Milano University and the Italian Space Agency (ASI). The key hardware of the advanced sensor prototype is a set of two types of load sensors - a hand-hold and foot restraints - similar in appearance to the mobility aids found in the Space Shuttle orbiter to assist the crew in moving inside the spacecraft, but able to measure the applied forces and moments about the x-, y-, and z- axes. The aim of Chapter 1 is to give a brief overview of the report contents. The first section summarizes the previous research efforts on astronaut-induced loads in microgravity. The second section provides information on the MICR0-G research project and the technology development work conducted at MIT. Section 1.3 details the motivation for designing a new generation of load sensors and describes the main enhancements and contributions of the MICR0-G advanced load sensors system compared to the EDLS system. Finally, the last section presents the outline of the report.

Newman, Dava J.↗

STS 110 Mission Highlights Resource Tape

A continuation of 'STS 110 Mission Highlights Resource Tape'. This video, Part 3 of 4, shows footage from flight days 6 through 9 of STS-110. The spacecrew includes Michael J. Bloomfield, Commander Stephen N. Frick, Pilot; Jerry L. Ross, Mission Specialist; Steven L. Smith, Mission Specialist; Ellen Ochoa, Mission Specialist; Lee M.E. Morin, Mission Specialist; Rex J. Walheim, Mission Specialist. On flight day 6, Ross and Morin conduct an EVA (extravehicular activity) to secure a tripod like strut to the S0 Truss of the International Space Station (ISS). They also move the drag link and keel pins from one face of the Truss to the other to free the rail on the truss for a railcar to move. Smith installs a camera onto the CANADARM robotic arm on flight day 7, and on flight day 8 the restraints are removed from the railcar connected to the S0 Truss in preparation for checkout. The checkout of the railcar is shown, including its inaugural run. Ross and Morin conduct another EVA on flight day 9 to complete the outfitting of the S0 Truss Structure. Notable footage includes views of Ross and Morin at work from the helmet-mounted camera on Ross' EVA suit, including close-ups of the pistol grip tool, CANADARM 2 onboard the ISS lit at sunrise, a 'diamond ring' effect formed by the Sun between the Earth's limb and the ISS, a brief shot of the Yucatan peninsula, and a end-to-end pan down the length of the ISS. The activities from other flights days can be seen on "STS 110 Mission Highlights Resource Tape" Part 1 of 4 (internal ID 2002137575), "STS 110 Mission Highlights Resource Tape" Part 2 of 4 (internal ID 2002137573), and "STS 110 Mission Highlights Resource Tape" Part 4 of 4 (internal ID 2002137517).

Source record↗

STS-110 Flight Day 7 Highlights

On the seventh day of STS-110, Mission Specialists Steven Smith and Rex Walheim are shown preparing for their second extravehicular activity (EVA) and the third of the mission, with the assistance of Mission Specialist Jerry Ross. Following this mission, Ross and Smith will be the first and second most experienced spacewalkers, respectively, in history. A camera mounted on the Space Shuttle Atlantis shows footage of the International Space Station. While Smith and Walheim are on EVA, Mission Specialists Ross and Lee Morin will provide choreography from inside the Atlantis crew cabin, Pilot Stephen Frick will operate the robotic arm, and Commander Mike Bloom will control the cameras on the robotic arm. Smith and Walheim are shown exiting the airlock hatch and then installing an PFR (Portable Foot Restraint) on the end of the robotic arm, from which much of the work will be done. Following the switching off of a circuit breaker, the main EVA task of rewiring umbilical cables that provide power, commands, and video is begun. These cables will be connected to the Mobile Transporter's (MT) robotic arm. The MT, an external transportation system which runs on rails, is seen with a helmet mounted camera as the astronauts work to release bolts that had served to secure the MT during launch. After a final check of the umbilical connections mated, the Umbilical Reconfiguration Panel is fitted over the cables, and the astronauts make their way to the airlock hatch.

Source record↗

STS-112 Mission Highlights Resource Tape Part 2 of 3

An overview of the STS-112 Mission is presented. The fourth flight day begins with a view inside of the Destiny Laboratory of the International Space Station where Expedition Five Commander Valery Korzun is shown. The robotics workstation where Mission Specialist Sandra Mangus and Flight Engineer Peggy Whitson operate Canadarm 2 to lift the S(1) Truss segment out of the payload bay of the Space Shuttle Atlantis and maneuver it for installation onto the S(1) Truss is presented. Mission Specialist Piers Sellers is shown preparing for his six and one half hour spacewalk by performing breathing exercises. Animation of the installation of the S(1) Truss, and also the unbirthing of the S(1) truss is also presented. Mission Specialists David Wolf and Piers Sellers are shown getting suited for their spacewalks. During the spacewalk, David Wolf is removing the antenna assembly from its launched position and Piers Sellers is releasing launch restraints from the Radiator Beam Assembly. A beautiful view of the coast of Texas is captured during this spacewalk. Flight day five shows pilot Pam Melroy and Mission Specialist Dave Wolf working inside of the International Space Station's Quest Airlock. Flight day six is shown with Dave Wolf and Piers Sellers exiting their spacesuits inside of the Quest Airlock Module after a successful spacewalk. This presentation ends with views of the International Space Station's installed S(1) Truss, rotation of the radiator assembly and the radiator's coolant tubing.

Source record↗

Buckling Of Long Compression-Loaded Anisotropic Plates Restrained Against Inplane Lateral and Shear Deformations

An approach for synthesizing buckling results and behavior for thin balanced and unbalanced symmetric laminates that are subjected to uniform axial compression loads and elastically restrained against inplane expansion, contraction, and shear deformation is presented. This approach uses a nondimensional analysis for infinitely long, flexurally anisotropic plates (coupling between bending and twisting) that are subjected to combined mechanical loads and is based on nondimensional parameters. In addition, nondimensional loading parameters are derived that account for the effects of the elastic inplane deformation restraints, membrane orthotropy, and membrane anisotropy on the induced prebuckling stress state. The loading parameters are used to determine buckling coefficients that include the effects of flexural orthotropy and flexural anisotropy. Many results are presented, for some selected laminates, that are intended to facilitate a structural designer's transition to the use of the generic buckling design curves that are presented and discussed in the paper. Several buckling response curves are presented that provide physical insight into the behavior for combined loads, in addition to providing useful design data. An example is presented that demonstrates the use of the generic design curves, which are applicable to a wide range of laminate constructions. The analysis approach and generic results indicate the effects and characteristics of laminate orthotropy and anisotropy in a very general and unifying manner.

Nemeth, Michael P.↗

Characterization of the Test Section Walls at the 14- by 22-Foot Subsonic Tunnel

The test section walls of the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel are known to move under thermal and pressure loads. Videogrammetry was used to measure wall motion during the summer of 2002. In addition, a laser distancemeter was used to measure the relative distance between the test section walls at a single point. Distancemeter and videogrammetry results were consistent. Data were analyzed as a function of temperature and pressure to determine their effects on wall motion. Data were collected between 50 and 100 F, 0 and 0.315 Mach, and dynamic pressures of 0 and 120 psf. The overall motion of each wall was found to be less than 0.25 in. and less than facility personnel anticipated. The results show how motion depends on the temperature and pressure inside the test section as well is the position of the boundary layer vane. The repeatability of the measurements was +/-0.06 in. This report describes the methods used to record the motion of the test section walls and the results of the data analysis. Future facility plans include the development of a suitable wall restraint system and the determination of the effects of the wall motion on tunnel calibration.

Lunsford, Charles B.↗

METAShield: Hot Metallic Aeroshell Concept for RLV/SOV

An innovative fuselage design approach that combines many desirable operational features with a simple and efficient structural approach is being developed by NASA. The approach, named METAShield for MEtallic TransAtmospheric Shield, utilizes lightly loaded, hot aeroshell structures surrounding integral propellant tanks that carry the primary structural loads. The aeroshells are designed to withstand the local pressure loads, transmitting them to the tanks with minimal restraint of thermal growth. No additional thermal protection system protects the METAShield, and a fibrous or multilayer insulation blanket, located in the space between the aeroshell and the tanks, serves as both high temperature and cryogenic insulation for the tanks. The concept is described in detail, and the performance and operational features are highlighted. Initial design results and analyses of the structural, thermal, and thermal-structural performance are described. Computational results evaluating resistance to hypervelocity impact damage, as well as some supporting aerothermal wind tunnel results. are also presented. Future development needs are summarized.

Scotti, Stephen J.↗

Evaluation of a Hybrid Elastic EVA Glove

The hybrid elastic design is based upon an American Society for Engineering Education (ASEE) glove designed by at the Space Systems Laboratory (SSL) in 1985. This design uses an elastic restraint layer instead of convolute joints to achieve greater dexterity and mobility during EVA (extravehicular activity). Two pilot studies and a main study were conducted using the hybrid elastic glove and 4000-series EMU (extravehicular activity unit) glove. Data on dexterity performance, joint range of motion, grip strength and perceived exertion was assessed for the EMU and hybrid elastic gloves with correlations to a barehanded condition. During this study, 30 test subjects performed multiple test sessions using a hybrid elastic glove and a 4000- series shuttle glove in a 4.3psid pressure environment. Test results to date indicate that the hybrid elastic glove performance is approximately similar to the performance of the 4000-series glove.

Korona, F. Adam↗

Shuttle Space Suit: Fabric/LCVG Model Validation

A detailed space suit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the space suit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of space suit shielding properties assumed the basic fabric layup (Thermal Micrometeoroid Garment, fabric restraints, and pressure envelope) and LCVG could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present space suit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and high-resolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the space suit s protection properties.

Wilson, J. W.↗

Shuttle Spacesuit: Fabric/LCVG Model Validation

A detailed spacesuit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the spacesuit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of spacesuit shielding properties assumed the basic fabric lay-up (Thermal Micrometeroid Garment, fabric restraints, and pressure envelope) and Liquid Cooling and Ventilation Garment (LCVG) could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present spacesuit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and highresolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the spacesuit's protection properties.

Wilson, J. W.↗

Airbreathing Hypersonic Vision-Operational-Vehicles Design Matrix

This paper presents the status of the airbreathing hypersonic airplane and space-access vision-operational-vehicle design matrix, with emphasis on horizontal takeoff and landing systems being studied at Langley; it reflects the synergies and issues, and indicates the thrust of the effort to resolve the design matrix including Mach 5 to 10 airplanes with global-reach potential, pop-up and dual-role transatmospheric vehicles and airbreathing launch systems. The convergence of several critical systems/technologies across the vehicle matrix is indicated. This is particularly true for the low speed propulsion system for large unassisted horizontal takeoff vehicles which favor turbines and/or perhaps pulse detonation engines that do not require LOX which imposes loading concerns and mission flexibility restraints.

Hunt, James L.↗

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies↗

Stressed to death: implication of lymphocyte apoptosis for psychoneuroimmunology

Psychological and physical stressors best exemplify the intercommunication of the immune and the nervous systems. It has been shown that stress significantly impacts leukocyte cellularity and immune responses and alters susceptibility to various diseases. While acute stress has been shown to enhance immune responses, chronic stress often leads to immunosuppression. Among many criteria examined upon exposure to chronic stress, the reduction in lymphocyte mitogenic response and lymphocyte cellularity are commonly assessed. We have reported that chronic restraint stress could induce lymphocyte reduction, an effect dependent on endogenous opioids. Interestingly, the effect of endogenous opioids was found to be exerted through increasing the expression of a cell death receptor, Fas, and an increased sensitivity of lymphocytes to apoptosis. Stress-induced lymphocyte reduction was not affected by adrenalectomy. In this review, based on available literature and our recent data, we will discuss the role of the hypothalamic-pituitary-adrenal axis and endogenous opioids and examine the mechanisms by which chronic stress modulates lymphocyte apoptosis.

Review Literature↗

Percutaneous aspiration of fluid for management of peritonitis in space

BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. Hypothesis: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.

Non-NASA Center↗