K^0 Regeneration on Deuterium
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A steam energy tip sheet for the Advanced Manufacturing Office (AMO)
Presented by NETL at AIChE Annual Meeting, 11/17
Disclosed are methods and systems for adjusting a High Voltage Direct Current (HVDC) compensator output signal to an HVDC system to reduce control loop modulus due to excessive time delay of sensor measurements. Two different time windows, a Short-Time Variance Window (STVW) and an Extended-Time Variance Window (ETVW) may be examined for detection of increased energy. To detect increased energy the HVDC compensator output signal may be passed through a bandpass filter, then variances for the STVW and ETVW may be generated to produce corresponding test statistics. The STVW and ETVW test statistics may be compared to hypothesis test thresholds and have binary logic based on the hypothesis test comparisons used to generate a gain. The gain may then be multiplied times the original HVDC feedback compensator output such that the adjusted HVDC feedback compensator output reduces the control loop modulus when applied to the HVDC system.
The zero energy buildings concept is more than 20 years old, and the paradigm shift from buildings as energy consumers to buildings as energy producers is underway. Buildings also consume land and material resources, however, with attendant environmental impacts. Another paradigm is emerging: a built environment that produces energy and is environmentally responsive and regenerative. This paper investigates an updated framework for thinking about zero energy buildings that includes discussions of prioritizing renewables; determining on-site versus off-site generation; exploring how and when buildings should use energy; and balancing renewables, storage, and energy efficiency. Buildings are typically connected to the utility grid and the utility grid develops largely in response to the built environment. If more buildings’ real time electricity use aligned with renewable generation, more renewables would be added to the grid. Ultimately, the goal for zero energy buildings will be to use 100% renewables, 100% of the time, matching loads with energy storage and renewable generation at each discrete timestep over a year. This target is beyond the current zero energy definitions, which focus on an annual balance of renewable supply and energy demand and use the grid to “store” excess production to make up for hours without sufficient on-site renewable generation. This paper expands this upgraded concept and outlines simple metrics to evaluate the alignment of renewable sources and storage with building loads. This process can provide insights on building design considerations, including the use of flexible loads and optimal resource management.
Presented by LRST at the International Pittsburgh Coal Conference, September 8-11, 2020, 9/10
Presented by LRST at the AIChE 2020 Annual Meeting, 11/17
Presented by NETL at Carbon Management Technology Conference, 07/19
Presented by NETL at 53rd IMPI Microwave Power Symposium, 06/19
Presented by NETL at 2019 AIChE Annual Meeting, 11/19
A system and method that includes flowing brine containing a metal ion through a reactor that includes porous particles having metal ion imprinted polymer having selective binding sites. The system and method further include discharging the brine from the reactor, contacting the porous particles with water, and pressurizing the reactor with carbon dioxide. The carbon dioxide reacts with the adsorbed metal ions to form a metal carbonate solution, where the metal carbonate solution can then be continuously purified with ion exchange. The method can include recycling eluent from the ion exchange back into the system for re-use. The method further includes depressurizing the reactor to precipitate metal carbonate from the metal carbonate solution and discharging the metal carbonate solution from the reactor.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This disclosure provides methods of improving callus formation in plants. This disclosure further provides genetically engineered plants with improved callus formation.
This disclosure provides systems, methods, and apparatus related to water desalination. In one aspect, a method includes generating a diluted draw solution using forward osmosis. Wastewater is on a first side of an osmotic membrane and a draw solution is on a second side of the osmotic membrane. The draw solution comprises a mixture of water and an ionic liquid. Water in the wastewater diffuses across the osmotic membrane to the draw solution to form the diluted draw solution. The diluted draw solution is heated using a photonic heater to a temperature above a lower critical solution temperature (LCST) of the ionic liquid to phase separate the diluted draw solution into the ionic liquid and treated water.
Compositions and methods of preparing the compositions are disclosed for sorbents and other surfaces that can adsorb and desorb carbon dioxide. A sorbent or surface can include a metal compound such as an alkali or alkaline earth compound and a support. The sorbent can be prepared by several methods, including an incipient wetness technique. The sorbents have a CO 2 adsorption and desorption profile. A sorbent having high levels of a metal compound and adsorbed CO 2 is disclosed.