Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Hydrogen uptake in graphite matrix at high temperature

Tritium management is a critical challenge for the next generation of nuclear reactors, such as Fluoride Salt Cooled High Temperature Reactors (FHRs) and High Temperature Gas-cooled Reactors (HTGRs), due to the higher production rate (up to 10,000 times) than conventional Light Water Reactors (LWRs). Graphitic materials employed as moderator, reflector, and fuel pebbles offer a potential pathway for tritium recovery by serving as a sink for tritium. Prediction of uptake capacity under reactor relevant conditions remains a challenge due to a lack of low partial pressure data and significant inter-grade variability of graphite. This study addresses these gaps by providing a comprehensive characterization of hydrogen (as a tritium surrogate) uptake and release behavior in the A3-3 graphite matrix (GM) used in fuel pebbles. Uptake measurements are performed at reactor relevant temperatures of 600- 800 °C, 1-200 Torr hydrogen pressure, and 15-120 min equilibration time, followed by thermal desorption spectroscopy up to 1100 °C. Uptake experiments at different equilibration times demonstrate the role of kinetics in hydrogen uptake, which can be modeled as a diffusion-with-trapping process. In the thermodynamics limit, the Sips adsorption model is shown to capture the uptake in A3-3 GM well. Our campaign provides a set of new results for hydrogen uptake in A3-3, including limiting uptake capacity at 600 °C, apparent diffusion coefficient at 600 °C, and the first estimates of the FHR/HTGR relevant (600 °C, 20 Pa partial pressure) equilibrium uptake capacity and time to saturation. Desorption data highlights a new site for hydrogen uptake, not observed in nuclear graphite, which we attribute to the non-graphitized binder. Using the Kissinger method, we estimate activation energy for release from the desorption peaks, confirming the activation energy for release from the basal planes and providing the first estimate for the activation energy of release from the binder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Neptune’s 2017 bright equatorial storm

Herein we report the discovery of a large (~8500 km diameter) infrared-bright storm at Neptune’s equator in June 2017. We tracked the storm over a period of 7 months with high-cadence infrared snapshot imaging, carried out on 14 nights at the 10 m Keck II telescope and 17 nights at the Shane 120 inch reflector at Lick Observatory. The cloud feature was larger and more persistent than any equatorial clouds seen before on Neptune, remaining intermittently active from at least 10 June to 31 December 2017. Our Keck and Lick observations were augmented by very high-cadence images from the amateur community, which permitted the determination of accurate drift rates for the cloud feature. Its zonal drift speed was variable from 10 June to at least 25 July, but remained a constant 237.4 ± 0.2 m s – 1 from 30 September until at least 15 November. The pressure of the cloud top was determined from radiative transfer calculations to be 0.3-0.6 bar; this value remained constant over the course of the observations. Multiple cloud break-up events, in which a bright cloud band wrapped around Neptune’s equator, were observed over the course of our observations. No “dark spot” vortices were seen near the equator in HST imaging on 6 and 7 October. The size and pressure of the storm are consistent with moist convection or a planetary-scale wave as the energy source of convective upwelling, but more modeling is required to determine the driver of this equatorial disturbance as well as the triggers for and dynamics of the observed cloud break-up events.

79 ASTRONOMY AND ASTROPHYSICS↗

SREMI: Super-resolution electromagnetic imaging with single-channel ground-penetrating radar

High-resolution near-surface imaging has important applications in civil engineering, infrastructure inspection, military threat detection, geological characterization, and lunar and planetary exploration. Zero-offset, singlechannel ground penetrating radar (GPR) imaging is an established technique for near-surface target imaging and sensing but often suffers from low spatial resolution and imaging artifacts, especially of deep structures. In response, we formulate the GPR imaging as a dual-sparsity optimization problem, and develop a super-resolution electromagnetic imaging method based on a fast iterative shrinkage-thresholding algorithm. We develop our GPR imaging method in the framework of electromagnetic exploding-reflectors simulation theory, therefore the imaging method is computationally efficient. In this work, we demonstrate through synthetic and field data examples that our method can produce sharper, more reliable images with fewer artifacts compared with single-pass reverse-time migration GPR method, thus leading to improved near-surface interpretation and object identification.

58 GEOSCIENCES↗

Protection of graphite from salt and gas permeation in molten salt reactors

The reactor core, moderator and reflectors of a thermal spectrum advanced molten salt reactor will constitute multi-tons of graphite. Porous reactor-grade graphite, if unprotected, can be permeated by molten salt depending on the infiltrating pressure differential and entrance diameters of accessible graphite pores. Salt and gas permeation of graphite can affect microstructural properties and radiation behavior but also facilitate diffusion, deposition and retention of fission products and tritium. Because of the significant void volume of nuclear graphite, fission products and tritium retention due to salt permeation necessitates seal coatings or pore impregnation to reduce open porosity. Alternatively, very fine-grained graphite grades with low Xe permeability are being developed. In this work, we survey the current technologies for mitigating salt and gas transport into graphite.

36 MATERIALS SCIENCE↗

Gas hydrate reservoirs and gas migration mechanisms in the Terrebonne Basin, Gulf of Mexico

Here, the interactions of microbial methane generation in fine-grained clay-rich sediments, methane migration, and gas hydrate accumulation in coarse-grained, sand-rich sediments are not yet fully understood. The Terrebonne Basin in the northern Gulf of Mexico provides an ideal setting to investigate the migration of methane resulting in the formation of hydrate in thin sand units interbedded with fractured muds. Using 3D seismic and well log data, we have identified several previously unidentified hydrate bearing units in the Terrebonne Basin. Two units are >100 m- thick fine-grained clay-rich units where gas hydrate occurs in near-vertical fractures. In some locations, these fine-grained units lack fracture features, and they contain 1-4-m thick hydrate bearing-sands. In addition, several other thin sand units were identified that contain gas hydrate, including one sand that was intersected by a well at the location of a discontinuous bottom-simulating reflector. Using correlation of well log data to seismic data, we have mapped and described these new units in detail across the extent of the available data, allowing us to determine the variation of seismic amplitudes and investigate the distribution of free gas and/or hydrate. We present several potential source-reservoir scenarios between the thick fractured mud units and thin hydrate bearing sands. We observe that hydrate preferentially forms within thin sand layers rather than fractures when sands are present in larger marine mud units. Based on regional mapping showing the patchy lateral extent of the thin sand layers, we propose that diffusive methane migration or short-migration of microbially generated methane from the marine mud units led to the formation of hydrate in these thin sands, as discontinuous sands would not be conducive to long-range migration of methane from deeper reservoirs.

03 NATURAL GAS↗

Optical and electronic properties of highly stable and textured hydrogenated ZnO:Al thin films

Highlights: ► We investigate the impact of hydrogen treatment at high temperature of ZnO:Al film. ► Electrical properties of the ZnO:Al films improved due to hydrogen annealing. ► Optical properties of the ZnO:Al films enhanced due to hydrogen annealing. ► ZnO:Al film properties strongly depend on the hydrogen treatment temperature. -- Abstract: We have experimentally investigated the effects of hydrogen-annealing on the structural, electrical, and optical properties of Al-doped ZnO (ZnO:Al) thin films prepared by RF magnetron sputtering at room temperature. From the X-ray diffraction observations, the orientation of ZnO:Al films was found to be a c-axis in the hexagonal structure. We found that intentionally incorporated hydrogen plays an important role in n-type conduction as a donor, improving free carrier concentration and electrical stability. We simultaneously obtained improved optical transmission and enhanced absorption edge of the ZnO:Al film due to hydrogen-annealing. Our experimental data suggest the hydrogen-annealing process as an important role in the enhancement of electrical and optical properties, which is promising as a back reflector material for thin-film solar cells.

36 MATERIALS SCIENCE↗

Photocatalytic reduction of CO2 using CdS nanorods on porous anodic alumina support

Highlights: • Commercial grade quality of aluminum foil was used to fabricate uniformly ordered PAA. • A more compassionate method of SILAR was adopted for synthesis on CdS on PAA. • Photocatalytic reduction of CO{sub 2} was carried on flat sheet reactor with mirror reflectors, which proves to be a potential candidate for large scale application. • Enhanced photocatalytic reduction of CO{sub 2} was obtained, when CdS was retained along the pore wall of the support. - Abstract: Solar reduction of CO{sub 2} to valuable chemicals has captured attention of several researchers due to its cumulative effect on reduction of global warming and also as an alternative to fossil fuels. Hexagonally ordered porous anodic alumina (PAA), prepared from commercial aluminium foil, was used as a support for CdS photocatalyst due to its unique honeycomb structure. The CdS nanorods were vertically grown on the PAA template by successive ion layer adsorption reaction (SILAR) method. The photocatalytic reduction of CO{sub 2} by CdS to CH{sub 3}OH was investigated using a flat sheet reactor under 10 W LED lamp. A peak CH{sub 3}OH formation at 144.5 μmol/g/h with 45.4% of photocatalytic efficiency and 1.97% of CO{sub 2} conversion efficiency in a single pass were obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 {+-} 1.5 treatment fractions; motion data were acquired for a mean of 26 {+-} 6.2 fractions. The mean age was 15.6 {+-} 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternative device structures for CIGS-based solar cells with semi-transparent absorbers

Here in this work, we discuss two alternative structures of CIGS-based solar cells, a bi-facial configuration and a back-wall configuration. One of the critical issues in these structures is fabrication of a transparent back contact which facilitates not only ohmic contact for holes in the valance but also an effective reflector for electrons in the conduction band. In order to meet these requirements of the transparent back contact, a p-type amorphous Si (p-a-Si)/intrinsic amorphous Si (i-a-Si) bi-layer was deposited onto the ITO back contact. Absorber films were formed by a metal precursor reaction in H 2 Se and H 2 S, and their thicknesses were adjusted to about 0.25 µm to enhance current collection from back-side illumination. The resulting devices with a bi-facial structure of SLG/ITO/p-Si/i-Si/Cu(In, Ga)(Se,S) 2 /CdS/i-ZnO/ITO/Ni-Al exhibited a comparable open-circuit voltage to a Cu(In, Ga)(Se,S) 2 cell on a Mo substrate in tests with illumination of both sides. Back-wall cells with a structure of SLG/ITO/p-Si/i-Si/Cu(In, Ga)(Se,S) 2 /CdS/i-ZnO/Ag-reflector were also fabricated and improved current collection by greater light trapping was achieved compared to the bi-facial cell with back-side illumination.

14 SOLAR ENERGY↗

Kinetics calculation of fast periodic pulsed reactors using MCNP6

Fast periodic pulsed reactor is a type of reactor in which the fission bursts are formed entirely with external reactivity modulation with a specified time periodicity. This type of reactors could generate much larger intensity of neutron beams for experimental use, compared with the steady state reactors. In the design of fast periodic pulsed reactors, the time dependent simulation of the power pulse is majorly based on a point kinetic model, which is known to have limitations. A more accurate calculation method is desired for the design analyses of fast periodic pulsed reactors. Monte Carlo computer code MCNP6 is used for this task due to its three dimensional transport capability with a continuous energy library. Some new routines were added to simulate the rotation of the movable reflector parts in the time dependent calculation. Fast periodic pulsed reactor IBR-2M was utilized to validate the new routines. This reactor is periodically in prompt supercritical state, which lasts for similar to 400 mu s, during the equilibrium state. This generates long neutron fission chains, which requires tremendously large amount of computation time during Monte Carlo simulations. Russian Roulette was applied for these very long neutron chains in MCNP6 calculation, combined with other approaches to improve the efficiency of the simulations. In the power pulse of the IBR-2M at equilibrium state, there is some discrepancy between the experimental measurements and the calculated results using the point kinetics model. MCNP6 results matches better the experimental measurements, which shows the merit of using MCNP6 calculation relative to the point kinetics model.

Zhong, Z.↗

Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light

Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner detector walls without significant loss in reflectance to reduce dead volumes around active noble liquids, outgassing, and potential backgrounds. We report on the experimental results to measure the dependence of the reflectance on thickness of two PTFE samples at wavelengths near 178 nm. No change in reflectance was observed as the wall thickness of a cylindrically shaped PTFE vessel immersed in liquid xenon was varied between 1 mm to 9.5 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction position, time, and energy resolution in organic scintillator bars with dual-ended readout

We report on the position, timing, and energy resolution of a range of plastic scintillator bars and reflector treatments using dual-ended silicon photomultiplier readout. These measurements are motivated by the upcoming construction of an optically segmented single-volume neutron scatter camera, in which neutron elastic scattering off of hydrogen is used to kinematically reconstruct the location and energy of a neutron-emitting source. For this application, interaction position resolutions of about 10 mm and timing resolutions of about 1 ns are necessary to achieve the desired efficiency for fission-energy neutrons. The results presented here indicate that this is achievable with an array of 5 x 5 x 190 mm 3 bars of EJ-204 scintillator wrapped in Teflon tape, read out with SensL’s J-series 6 x 6 mm 2 silicon photomultipliers. With two independent setups, we also explore the systematic variability of the position resolution, and show that, in general, using the difference in the pulse arrival time at the two ends is less susceptible to systematic variation than using the log ratio of the charge amplitude of the two ends. Finally, we measure a bias in the absolute time of interactions as a function of position along the bar: the measured interaction time for events at the center of the bar is 100 ps later than interactions near the SiPM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The small-angle neutron scattering extension in MCNPX and the SANS cross section for nanodiamonds

Detonation nanodiamonds provide an intriguing prospect for the development of a very cold neutron (VCN) source or as a high albedo material for VCN reflection helping to control leakage of cold and very cold neutrons in a moderator. The investigation of source and reflector designs necessitates the development of new simulation tools for existing Monte Carlo codes that include small angle neutron scattering (SANS). The SANS extension in MCNPX 2.7 provides an analytical model of hard-sphere scattering with variable scattering particle sizes, size distributions, and packing fractions in order to supplement currently existing scattering kernels as well as the capability to read an experimentally determined small angle neutron scattering profile from a data file. The SANS extension is discussed and compared to nanodiamond SANS measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗