Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Twin-pulse seeding enables pump-probe capabilities in the EUV to soft X-ray spectrum at synchrotron light sources

Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.1 to 10 ps. In the twin-pulse seeding scheme, the same electron bunch could undergo modulation from two distinct laser pulses. Later stages would produce independent harmonics in subsequent straight sections. There are two variations of this twin-pulse seeding scheme, supporting different scientific applications. With a common modulation in stage 1, the first option allows simultaneously two independent radiation sources, with a full coverage of the EUV (2.5 to 50 nm) to soft X-ray (1.25 to 2.5 nm) spectrum; for the second option, the same stage 2 undulator could generate two coherent pulses both fitting within the FEL bandwidth, or at distinct harmonics. We present particle tracking simulation studies based on the APS-U lattice, including quantum excitation and radiation damping. These simulations indicate that there is no degradation of the modulated longitudinal phase space even when the two stages are separated by as many as 10 BM sections.

36 MATERIALS SCIENCE↗

Site Environmental Report for 2016

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2016. The format and content of this report satisfy the requirements of both DOE Order 231.1B Admin Chg 1, Environment, Safety, and Health Reporting, and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). Activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. Berkeley Lab implements an Environmental Management System (EMS) to oversee these compliance activities and improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the operating contract’s performance evaluation process. For fiscal year (FY) 2016, which began October 1, 2015, and ended September 30, 2016, the EMS was given a performance rating of A minus for its management of environmental activities (on a scale from A plus as the highest grade to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2016 rating was based on how Berkeley Lab met the objective in DOE’s FY 2017 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. To support this rating, Berkeley Lab prepared a list of projects completed during the performance period that achieved reduced environmental impacts. The EMS was also graded through the federal Office of Management and Budget’s EMS Annual Report Data, in which elements of the International Organization for Standardization (ISO) 14001 standard are rated and the degree of integration between the EMS and Berkeley Lab’s sustainable practices is measured. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2016, Berkeley Lab received a score of green, as described in more detail in Chapter 2. An overview of environmental protection and restoration programs is provided (Chapter 3), including information about compliance activities, operating permits, and regulatory agency inspections that occurred during 2016. Six minor violations issued during these inspections are discussed, one of which was rescinded in 2017. This report also includes information on environmental monitoring performed in 2016 (Chapter 4). The results of these monitoring activities confirmed that groundwater cleanup actions continue to show improving conditions, and all emissions and discharges from LBNL operations were within environmental compliance release limits with the exception of some stormwater discharges. While most stormwater discharges measured throughout the LBNL site fall within acceptable levels established by the state's stormwater permit, iron and aluminum exceeded permitted levels. Berkeley Lab is aggressively implementing controls to reduce iron and aluminum discharge levels. The controls include construction of asphaltic berms to restrain and filter runoff to storm drains, and installation of filtration units in storm drain basins to absorb metal contaminants. The radiological dose assessments (Chapter 5) performed in 2016 concluded that the maximum dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.12% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/year); the dose from all radiation sources at Berkeley Lab was approximately 0.1% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.4% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for 2017

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2017. The format and content of this report satisfy the requirements of both DOE Order 231.1B, Administrative Change 1 (Environment, Safety, and Health Reporting) and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). Activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. Berkeley Lab implements an Environmental Management System (EMS) to oversee these compliance activities and continually improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the performance evaluation process of Contract 31. For fiscal year (FY) 2017, which began October 1, 2016, and ended September 30, 2017, the EMS was given a performance rating of B plus for its management of environmental activities (on a scale from A plus as the highest grade to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2017 rating was based on how Berkeley Lab met the objective in DOE’s FY 2017 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. Six significant accomplishments, which ranged from effective teaming on projects and with regulatory agencies to improved program assessment approaches, were factors in the rating. The EMS was also graded through the federal Office of Management and Budget’s annual EMS performance metrics, in which a reporting scorecard rates elements of the International Organization for Standardization (ISO) 14001 standard and the degree of integration between the EMS and Berkeley Lab’s sustainable practices. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2017, Berkeley Lab received a score of green, as described in more detail in Chapter 2. An overview of environmental protection and restoration programs is provided, including information about compliance activities, operating permits, and regulatory agency inspections that occurred during 2017. Thirteen minor violations issued during City of Berkeley inspections of above and underground storage tanks, treatment units, and hazardous waste storage areas are discussed in this chapter. This report also includes information on environmental monitoring performed in 2017. The results of these monitoring activities confirmed that groundwater cleanup actions continue to show improving conditions, and all emissions and discharges from LBNL operations were within environmental compliance release limits, with the exception of some stormwater discharges. Most stormwater discharges measured throughout the LBNL site fall within acceptable levels established by the state’s stormwater permit; however, iron and aluminum exceeded Numeric Action Levels. To reduce iron and aluminum discharge levels, Berkeley Lab is aggressively implementing controls such as construction of asphaltic berms and check dams to restrain and filter runoff to storm drains, and installation of filtration units in storm drain basins to collect sediment and absorb metal contaminants. The radiological dose assessments performed in 2017 concluded that the maximum potential dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.1% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/yr); the potential dose from all radiation sources at Berkeley Lab was approximately 0.06% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.2% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

Decision-making Framework to Support the End-of-Life Management of High-Activity Radioactive Sources

Sealed radioactive sources are used for an extremely wide range of purposes, including as radiation sources in various nuclear facilities, universities, hospitals, biomedical and industrial applications, as well as for geological prospecting and exploration. The proper management of these sealed radioactive sources once they have reached their end-of-life is still a global challenge. Very few field-tested Mobile Hot Cells (MHC) exist in the world to support the end-of-life management of disused high-activity radioactive sources. One of the critical challenges that a source recovery team encounters on each site is to find adequate space, and access to that space to complete the staging and recapture process with a MHC; this process is tedious, uncertain, and time-consuming. Therefore, it is essential to understand the planning and management of the MHC setup and takedown. Currently, there isn't an single capable planning tool that will provide an effective medium to plan, inform, educate, and communicate knowledge about the environment where the MHC will be deployed. We present a novel approach for the planning and management of the deployment of the MHC to several different sites that relies on technology. Furthermore, this planning tool will support collaboration, promote information sharing, and foster better decision making processes, resulting in a more efficient, and reliable setup and source recovery with the MHC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization for Single-Spike X-Ray FELs at LCLS with a Low Charge Beam

The Linac Coherent Light Source is an x-ray free-electron laser at the SLAC National Accelerator Laboratory, which is operating at x-ray wavelengths of 20-1.2 Angstrom with peak brightness nearly ten orders of magnitude beyond conventional synchrotron radiation sources. At the low charge operation mode (20 pC), the x-ray pulse length can be <10 fs. In this paper we report our numerical optimization and simulations to produce even shorter x-ray pulses by optimizing the machine and undulator setup at 20 pC charge. In the soft x-ray regime, with combination of slotted-foil or undulator taper, a single spike x-ray pulse is achievable with peak FEL power of a few 10s GW. Linac Coherent Light Source (LCLS), the world's first hard x-ray Free electron laser (FEL), has started operation since 2009. With nominal operation charge of 250 pC, the generated x-ray pulse length is from 70 fs to a few hundred fs. This marks the beginning of a new era of ultrashort x-ray sciences. In addition, a low charge (20pC) operation mode has also been established. Since the collective effects are reduced at the low charge mode, we can increase the compression factor and still achieve a few kA peak current. The expected electron beam and x-ray pulses are less than 10 fs. There are growing interests in even shorter x-ray pulses, such as fs to sub-fs regime. One of the simple solutions is going to even lower charge. As discussed, single-spike x-ray pulses can be generated using 1 pC charge. However, this charge level is out of the present LCLS diagnostic range. 20 pC is a reasonable operation charge at LCLS, based on the present diagnostic system. At 20 pC in the soft x-ray wavelength regime, we have experimentally demonstrated that FEL can work at undercompression or over-compression mode, such as 1 degree off the full-compression; at full-compression, however, there is almost no lasing. In hard x-ray wavelength regime, we observed that there are reasonable photons generated even at full-compression mode, although the photon number is less than that from under-compression or over-compression mode. Since we cannot measure the x-ray pulse length at this time scale, the machine is typically optimized for generating maximum photons, not minimum pulse length. In this paper, we study the methods of producing femtosecond (or single-spike) x-ray pulses at LCLS with 20 pC charge, based on start-to-end simulations. Figure 1 shows a layout of LCLS. The compression in the second bunch compressor (BC2) determines the final e-beam bunch length. However, the laser heater, dog-leg after the main linac (DL2) and collective effects also affect the final bunch length. To adjust BC2 compression, we can either change the L2 phase or BC2 R{sub 56}. In this paper we only tune L2 phase while keep BC2 R{sub 56} fixed. For the start-to-end simulations, we used IMPACT-T and ELEGANT tracking from the photocathode to the entrance of the undulator, after that the FEL radiation was simulated with GENESIS. IMPACT-T tracks about 10{sup 6} particles in the injector part until 135 MeV, including 3D space charge force. The output particles from IMPACT-T are smoothed and increased to 12 x 10{sup 6} to reduce high-frequency numerical noise for subsequent ELEGANT simulations, which include linear and nonlinear transport effects, a 1D transient model of CSR, and longitudinal space charge effects, as well as geometric and resistive wake fields in the accelerator. In GENESIS part, the longitudinal wake field from undulator chamber and longitudinal space field are also included.

43 PARTICLE ACCELERATORS↗

Analysis of seismic sources for different mechanisms of fracture growth for microseismic monitoring applications

We have developed and illustrated an approach for geomechanic modeling of elastic wave generation (microsiesmic event occurrence) during incremental fracture growth. We then derived properties of effective point seismic sources (radiation patterns) approximating obtained wavefields. These results establish connection between geomechanic models of hydraulic fracturing and microseismic monitoring. Thus, the results of the moment tensor inversion of microseismic data can be related to different geomechanic scenarios of hydraulic fracture growth. In future, the results can be used for calibrating hydrofrac models. We carried out a series of numerical simulations and made some observations about wave generation during fracture growth. In particular when the growing fracture hits pre-existing crack then it generates much stronger microseismic event compared to fracture growth in homogeneous medium (radiation pattern is very close to the theoretical dipole-type source mechanism)

42 ENGINEERING↗

X-ray science using the ESRF—extremely brilliant source

The Extremely Brilliant Source (EBS), the first high-energy 4th-generation synchrotron radiation source, constructed at the ESRF and based upon the novel concept of a Hybrid Multi-Bend Achromat (HMBA), has started user operation on August 25th, 2020. We report here on selected recent scientific results exploiting the greatly improved performances of this novel X-ray source.

43 PARTICLE ACCELERATORS↗

Preshot Summary for Coax-14A OMEGA Experiments on January 28th, 2014

The goal of the Coax campaign is to implement an experiment with a highly anisotropic radiation source to benchmark the performance of CASSIO in a regime where radiation transport modeling requires an implicit Monte Carlo treatment instead of the standard diffusion treatment. The system is created by driving an Au halfhohlraum (halfraum) with a foam package mounted on the end opposite of the halfraum LEH. Different types of Ta apertures are inserted at the foam/halfraum interface to make the radiation drive incident on the foam anisotropic.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

Burt, Eric A.↗

Selection of Training Sets for 235U Source Detection Classifiers Using Gamma Signatures

The machine learning methods for classifiers to detect low level radiation sources are of interest when suitable training data sets are available. Their application and performance assessment, however, involves the aspects of over-fitting and training data selection that are somewhat uncommon in other existing methods for this task.We study U-235 gamma signatures using data sets collected by 21 NaI detectors under controlled conditions. The gamma spectra are collected by the detectors located at different distances from the source, and we study their choice as training sets for classifiers to detect a source. The detectors form the near, middle and outer groups based on the distance to source. The classifiers based on the outer group are susceptible to over-fitting, that is, they achieve low training error but incur much higher testing error in independent tests. The other two groups achieve lower training error and comparable testing error, and the near group achieves the overall lowest error. In detecting a source at an unknown distance, the farther detectors in the middle group achieve the overall lowest testing error with limited over-fitting, thereby indicating the complex dependencies between the training and classifier performance.

Rao, Nageswara↗

Ultraviolet Radiation Round-Robin Testing of Various Backsheets for Photovoltaic Modules

Durability testing of materials exposed to natural weathering requires testing of the ultraviolet (UV) stability, especially for polymeric materials. The type approval testing of photovoltaic (PV) modules according to standards IEC 61215 and IEC 61646, which includes a so-called UV preconditioning test with a total UV dose of 15 kWh/m2, does not correspond to the real loads during lifetime. Between 3%-10% of the UV radiation has to be in the spectral range between 280 and 320 nm (UV-B) in the recent editions of the standards. However, the spectral distribution of the radiation source is very important because different samples show very individual spectral sensitivity for the radiation offered. Less than 6% of the intensity of solar radiation exists in the UV range. In the case of an increase of the intensity of the light source for accelerating the UV test, overheating of the samples would have to be prevented more rigorously and the temperature of the samples have to be measured to avoid misinterpretation of the test results.

14 SOLAR ENERGY↗

3D Backscatter Imaging System

Systems and methods for imaging an object using backscattered radiation are described. The imaging system comprises both a radiation source for irradiating an object that is rotationally movable about the object, and a detector for detecting backscattered radiation from the object that can be disposed on substantially the same side of the object as the source and which can be rotationally movable about the object. The detector can be separated into multiple detector segments with each segment having a single line of sight projection through the object and so detects radiation along that line of sight. Thus, each detector segment can isolate the desired component of the backscattered radiation. By moving independently of each other about the object, the source and detector can collect multiple images of the object at different angles of rotation and generate a three dimensional reconstruction of the object. Other embodiments are described.

Turner, D. Clark↗

Low-level measuring techniques for neutrons: High accuracy neutron source strength determination and fluence rate measurement at an underground laboratory

We report on measuring techniques for neutrons that have been developed at the Physikalisch-Technische Bundesanstalt (PTB), the German National Metrology Institute. PTB has characterized radioactive sources used in the BOREXINO and XENON100 experiments. For the BOREXINO experiment, a {sup 228}Th gamma radiation source was required which would not emit more than 10 neutrons per second. The determination of the neutron emission rate of this specially designed {sup 228}Th source was challenging due to the low neutron emission rate and because the ratio of neutron to gamma radiation was expected to be extremely low, of the order of 10{sup −6}. For the XENON100 detector, PTB carried out a high accuracy measurement of the neutron emission rate of an AmBe source. PTB has also done measurements in underground laboratories. A two month measurement campaign with a set of {sup 3}He-filled proportional counters was carried out in PTB's former UDO underground laboratory at the Asse salt mine. The aim of the campaign was to determine the intrinsic background of detectors, which is needed for the analysis of data taken in lowintensity neutron fields. At a later time, PTB did a preliminary measurement of the neutron fluence rate at the underground laboratory Felsenkeller operated by VKTA. By taking into account data from UDO, Felsenkeller, and detector calibrations made at the PTB facility, it was possible to estimate the neutron fluence rate at the Felsenkeller underground laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion composition and drift observations in the nighttime equatorial ionosphere

The first in situ measurements of ion composition in the nighttime equatorial E and F region ionospheres (90-300 km) are presented and discussed. These profiles were obtained by two rocket-borne ion mass spectrometers launched from Thumba, India on March 9-10, 1970 at solar zenith angles of 112 deg and 165 deg. Ionosonde data established that the composition was measured at times bounding a period of F region downward drift. During this period the ions O(+) and N(+) were enhanced by one to three orders of magnitude between 220 and 300 km. Below the drift region (200 km), O(+) ceased to be the major ionic constituent, but the concentrations of O(+) and N(+) remained larger than predicted from known radiation sources and loss processes. Here also, both the O2(+) and NO(+) profiles retained nearly the same shape and magnitude throughout the night in agreement with theories assuming scattered UV radiation to be the maintaining source. Light metallic ions including Mg(+), Na(+) and possibly Si(+) were observed to altitude approaching 300 km, while the heavier ions Ca(+) and K(+) were seen in reduced quantity to 200 km. All metal ion profiles exhibited changes which can be ascribed to vertical drifting.

Goldberg, R. A.↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

Watts Bar I Ex-Core Analyses using VERA

The integration and direct coupling of the Oak Ridge National Laboratory (ORNL) Shift Monte Carlo code within the Consortium for Advanced Simulation of Light Water Reactors (CASL) Virtual Environment for Reactor Applications (VERA) offers unique capabilities that combine high-fidelity in-core and ex-core radiation transport. In this recent development activity, the deterministic neutronics code MPACT performs the incore radiation transport with temperature feedback using COBRA-TF (CTF), and provides the fission source to Shift for a follow-on fixed source radiation transport calculation to determine ex-core quantities of interest. The coupling of MPACT to Shift allows the neutron source for the ex-core transport to be calculated from the time-dependent, fully coupled MPACT solution. This paper presents the first use of VERA to perform coupon irradiation for validation of its ex-core capabilities.

Davidson, Eva↗

Improvements in the Method of Radiation Anomaly Detection by Spectral Comparison Ratios

Algorithms for detecting illicit gamma radiation sources must respond to a wide variety of threat signatures and ignore a wider variety of clutter. Previously, we described the Nuisance-rejection Spectral Comparison Ratio Anomaly Detection (N-SCRAD) method for indicating the presence of threat sources during mobile search operations. Our method relies on the formulation of radiation alarm test statistics applied to detector counts in numerous spectral regions of interest and our test statistics are standardized by local estimates of background variability. In this work we present a new automated procedure for selecting test statistics and specifying the regions of interest based on minimizing detectable count rates of prototype threat spectra at a specified false positive rate using simulated annealing. The new procedure can be applied to configuring the detection algorithm when the prototype threats are many and diverse without significantly compromising the detection sensitivity to any one of them. N-SCRAD makes use of estimates of background variability obtained during a search from prior measurements of background. In applications such estimates made purely from past measurements sometimes do not extrapolate well to current conditions. In this work we present a new method for correcting those estimates to current conditions of the total count rate. We demonstrate that the correction lowers detection thresholds for a specified false positive rate, enabling greater sensitivity to targets. The two proposed improvements to N-SCRAD maximize detection power for the expected variety of possible threats while reducing or maintaining the false positive rate.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗