Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

DAC-3 Pointing Stability Analysis Results for SAGE 3 and Other Users of the International Space Station (ISS) Payload Attachment Sites (PAS)

The purpose of this paper is to provide final results of a pointing stability analysis for external payload attachment sites (PAS) on the International Space Station (ISS). As a specific example, the pointing stability requirement of the SAGE III atmospheric science instrument was examined in this paper. The instrument requires 10 arcsec stability over 2 second periods. SAGE 3 will be mounted on the ISS starboard side at the lower, outboard FIAS. In this engineering analysis, an open-loop DAC-3 finite element model of ISS was used by the Microgravity Group at Johnson Space Flight Center to generate transient responses at PAS to a limited number of disturbances. The model included dynamics up to 50 Hz. Disturbance models considered included operation of the solar array rotary joints, thermal radiator rotary joints, and control moment gyros. Responses were filtered to model the anticipated vibration attenuation effects of active control systems on the solar and thermal radiator rotary joints. A pointing stability analysis was conducted by double integrating acceleration transient over a 2 second period. Results of the analysis are tabulated for ISS X, Y, and Z Axis rotations. These results indicate that the largest excursions in rotation during pointing occurred due to rapid slewing of the thermal radiator. Even without attenuation at the rotary joints, the resulting pointing error was limited to less than 1.6 arcsec. With vibration control at the joints, to a maximum 0.5 arcsec over a 2 second period. Based on this current level of model definition, it was concluded that between 0 - 50 Hz, the pointing stability requirement for SAGE 3 will not be exceeded by the disturbances evaluated in this study.

Woods-Vedeler, Jessica A.↗

System for Manipulating Drops and Bubbles Using Acoustic Radiation Pressure

The manipulation and control of drops of liquid and gas bubbles is achieved using high intensity acoustics in the form of and/or acoustic radiation pressure and acoustic streaming. generated by a controlled wave emission from a transducer. Acoustic radiation pressure is used to deploy or dispense drops into a liquid or a gas or bubbles into a liquid at zero or near zero velocity from the discharge end of a needle such as a syringe needle. Acoustic streaming is useful in manipulating the drop or bubble during or after deployment. Deployment and discharge is achieved by focusing the acoustic radiation pressure on the discharge end of the needle, and passing the acoustic waves through the fluid in the needle. through the needle will itself, or coaxially through the fluid medium surrounding the needle. Alternatively, the acoustic waves can be counter-deployed by focusing on the discharge end of the needle from a transducer axially aligned with the needle, but at a position opposite the needle, to prevent premature deployment of the drop or bubble. The acoustic radiation pressure can also be used for detecting the presence or absence of a drop or a bubble at the tip of a needle or for sensing various physical characteristics of the drop or bubble such as size or density.

Oeftering, Richard C.↗

Space station thermal control surfaces

Mission planning documents were used to analyze the radiator design and thermal control surface requirements for both space station and 25-kW power module, to analyze the missions, and to determine the thermal control technology needed to satisfy both sets of requirements. Parameters such as thermal control coating degradation, vehicle attitude, self eclipsing, variation in solar constant, albedo, and Earth emission are considered. Four computer programs were developed which provide a preliminary design and evaluation tool for active radiator systems in LEO and GEO. Two programs were developed as general programs for space station analysis. Both types of programs find the radiator-flow solution and evaluate external heat loads in the same way. Fortran listings are included.

Maag, C. R.↗

Operational Health Physics for Radiation Source Payloads

Spacecraft payloads processed at the Kennedy Space Center (KSC) frequently include ionizing and nonionizing radiation sources that require controls to protect the health of the workers involved in the ground operations. At KSC, a robust radiation protection program ensures that radiation hazards are identified, and appropriate controls are implemented using a radiation use authorization (RUA) process and Radiation Protection Committee review and approval. The Health Physics Office provides monitoring and oversight to ensure compliance. A brief overview of health physics activities in support of the Mars 2020 mission will be described to illustrate the overall management of radiation sources during payload ground processing.

Kurt R Geber↗

A hybrid coupler for directing quantum light emission with high radiative Purcell enhancement to a dielectric metasurface lens

Quantum photonic technologies such as quantum sensing, metrology, and simulation could be transformatively enabled by the availability of integrated single photon sources with high radiative rates and photon collection efficiencies. We address these challenges for quantum emitters formed from color center defect sites such as those in hexagonal boron nitride, which are promising candidates as single photon sources due to their bright, stable, polarized, and room temperature emission. We report design of a nanophotonic coupler from color center quantum emitters to a dielectric metasurface lens. The coupler is comprised of a hybrid plasmonic–dielectric resonator that achieves a large radiative Purcell enhancement and partial control of far-field radiation. We report radiative Purcell factors up to 285 and photon collection efficiencies up to 89% for a lossless metasurface, applying a continuous hyperboloidal phase-front. Our hybrid plasmonic–dielectric coupler interfacing two nanophotonic elements is a compound optical element, analogous to those found in microscope objective lenses, which combine multiple optical functions into a single component for improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data compression/error correction digital test system. Appendix 1: Operation

The DC/EC operating instructions are provided for anticipated operating conditions. The instructions are supported by illustrations and tables for the controls and indication of radiation-built equipment. The transmitter control panel provides a functional representation of the system configuration. Inputs and outputs of functional units are brought to jacks on the panel for interconnection and monitoring, and to allow independent use of subsystems of the transmitter.

Source record↗

Proton Radiotherapy for Childhood Ependymoma: Initial Clinical Outcomes and Dose Comparisons

Purpose: To report preliminary clinical outcomes for pediatric patients treated with proton beam radiation for intracranial ependymoma and compare the dose distributions of intensity-modulated radiation therapy with photons (IMRT), three-dimensional conformal proton radiation, and intensity-modulated proton radiation therapy (IMPT) for representative patients. Methods and Materials: All children with intracranial ependymoma confined to the supratentorial or infratentorial brain treated at the Francis H. Burr Proton Facility and Harvard Cyclotron between November 2000 and March 2006 were included in this study. Seventeen patients were treated with protons. Proton, IMRT, and IMPT plans were generated with similar clinical constraints for representative infratentorial and supratentorial ependymoma cases. Tumor and normal tissue dose-volume histograms were calculated and compared. Results: At a median follow-up of 26 months from the start date of radiation therapy, local control, progression-free survival, and overall survival rates were 86%, 80%, and 89%, respectively. Subtotal resection was significantly associated with decreased local control (p = 0.016). Similar tumor volume coverage was achieved with IMPT, proton therapy, and IMRT. Substantial normal tissue sparing was seen with proton therapy compared with IMRT. Use of IMPT will allow for additional sparing of some critical structures. Conclusions: Preliminary disease control with proton therapy compares favorably with the literature. Dosimetric comparisons show the advantage of proton radiation compared with IMRT in the treatment of ependymoma. Further sparing of normal structures appears possible with IMPT. Superior dose distributions were accomplished with fewer beam angles with the use of protons and IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Active Control of Fan-Generated Tone Noise

This paper reports on an experiment to control the noise radiated from the inlet of a ducted fan using a time domain active adaptive system. The control ,sound source consists of loudspeakers arranged in a ring around the fan duct. The error sensor location is in the fan duct. The purpose of this experiment is to demonstrate that the in-duct error sensor reduces the mode spillover in the far field, thereby increasing the efficiency of the control system. The control system is found to reduce the blade passage frequency tone significantly in the acoustic far field when the mode orders of the noise source and of the control source are the same, when the dominant wave in the duct is a plane wave. The presence of higher order modes in the duct reduces the noise reduction efficiency, particularly near the mode cut-on where the standing wave component is strong, but the control system converges stably. The control system is stable and converges when the first circumferential mode is generated in the duct. The control system is found to reduce the fan noise in the far field on an arc around the fan inlet by as much as 20 dB with none of the sound amplification associated with mode spillover.

Gerhold, Carl H.↗

Constitutive Model of Radiation Aging Effects in Filled Silicone Elastomers under Strain

Filled silicone elastomers, an essential component in many technological applications, are often subjected to controlled or unintended radiation for a variety of reasons. Radiation exposure can lead to permanent mechanical and structural changes in the material, which is manifested as altered mechanical response, and in some cases, a permanent set. For unfilled elastomers, network theories developed and refined over decades can explain these effects in terms of chain-scission and cross-link formation and a hypothesis involving independent networks formed at different strain levels of the material. In this work, we expose a filled silicone rubber to gamma radiation while being under finite elongational strain and show that the observed mechanical and structural changes can be quantitatively modeled within the same theoretical framework developed for unfilled elastomers as long as nuances associated with the Mullins effect are accounted for in a consistent manner. In this work, we employ Ogden’s incompressible hyperelastic model within the framework of Tobolsky’s two-network scheme to describe the observed permanent set and mechanical modulus changes as a function of radiation dosage. In the process, we conclude that gamma radiation induces both direct cross-linking at chain crossings (H-links) and main-chain-scission followed by cross-linking (Y-links). We provide an estimate of the ratio of chain-scission to cross-linking rates, which is in reasonable agreement with previous experimental estimate from Charlesby–Pinner analysis. We use density functional theory (DFT)-based quantum mechanical calculations to explore the stability of –Si and –SiO radicals that form upon a radiation-induced chain-scission event, which sheds light on the relative rates of Y-linking and H-linking processes.

36 MATERIALS SCIENCE↗

Mathematical modelling of dispersion-managed thulium/holmium fibre lasers

The mathematical model of a dispersion-managed thulium/holmium fibre laser is described; the results of numerical calculations and their comparison with the experimental data are presented. Qualitative agreement of the results of the mathematical modelling with those of the experiment is obtained. Using the methods of mathematical modelling, the variation in the characteristics of the optical pulses due to the change in the average cavity dispersion is analysed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mysterious diel cycles of mercury emission from soils held in the dark at constant temperature

It is well known that mercury (Hg) emission from soils is largely controlled by solar radiation and soil temperature, exhibiting diel cycles that closely follow diel variations of solar radiation. To study soil Hg emission processes, we conducted experiments by measuring soil Hg emission fluxes under controlled conditions in the laboratory with a dynamic flux chamber using outside ambient air as flushing air. Unexpectedly, we observed consistent, recurring diel cycles of Hg emissions from dry soils held at constant temperature in the dark in our laboratory. The peaks of the emissions also seemed subject to some seasonal variation and to respond to local weather conditions with lower flux peaks in wintertime and on cloudy or rainy days. Finally, much lower soil Hg emission fluxes were observed in the presence of Hg-free zero air than in the presence of outside ambient air. It is hypothesized that some unidentified air-borne substance(s) in the ambient air might be responsible for the observed diel cycles of soil Hg emission. Further elaborate mechanistic investigations are clearly needed to test the initial working hypotheses and uncover the cause for this interesting, mysterious phenomenon. The present work and recent finding of enhancement of Hg emissions from soil and mineral particles by O3 seem to point to a research need to probe the possible role of near-ground atmospheric chemistry in Hg air/soil exchange.

54 ENVIRONMENTAL SCIENCES↗

Anthropogenic–biogenic interaction amplifies warming from emission reduction over the southeastern US

A decline of surface biogenic secondary organic aerosols through the mediation of reduced anthropogenic aerosols has been recognized as an air quality co-benefit of anthropogenic emission control over the southeastern US. However, the climate impacts of this anthropogenic–biogenic interaction remain poorly understood. Here, we identified a substantial decline of summertime aerosol loading aloft over the southeastern US in recent decades through the interaction, which leads to a stronger decline in column-integrated aerosol optical depth and a greater increase in radiative fluxes over the southeastern than northeastern US, different from trends of anthropogenic emissions and near-surface aerosol loading. The anthropogenic–biogenic interaction is shown to explain more than 60% of the coherent increasing trend of 5.3 Wm -2 decade -1 in clear-sky surface downward radiative fluxes. We show that current climate models fail to represent this interaction. The interaction is further projected to amplify the positive radiative forcing from emission control by 42.3% regionally over the southeastern US and globally by 5.4% in 2050 under RCP4.5 compared to 2005. This amplification effect implies greater challenges to achieving the Paris Agreement temperature targets with continuous emission control in future.

54 ENVIRONMENTAL SCIENCES↗

Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens

This is the Final Progress Report for DOE-funded research project DE-PS02-08ER08-01 titled “Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens”. The project focuses on the effects of low-linear energy transfer (LET) radiation on the ocular lens. The lens is an exquisitely radiosensitive tissue with a highly-ordered molecular structure that is amenable to non-invasive optical study from the periphery. These merits point to the lens as an ideal target for laser-based molecular biodosimetry (MBD). Following exposure to different types of ionizing radiations, the lens demonstrates molecular changes (e.g., oxidation, racemization, crosslinkage, truncation, aggregation, etc.) that impact the structure and function of the long-lived proteins in the cytosol of lens fiber cells. The vast majority of proteins in the lens comprise the highly-ordered crystallins. These highly conserved lens proteins are amongst the most concentrated and stable in the body. Once synthesized, the crystallins are retained in the fiber cell cytoplasm for life. Taken together, these properties point to the lens as an ideal system for quantitative in vivo MBD assessment using quasi-elastic light scattering (QLS) analysis. In this project, we deploy a purpose-designed non-invasive infrared laser QLS instrument as a quantitative tool for longitudinal assessment of pre-cataractous molecular changes in the lenses of living mice exposed to low-dose low-LET radiation compared to non-irradiated sham controls. We hypothesize that radiation exposure will induce dose-dependent changes in the molecular structure of matrix proteins in the lens. Mechanistic assays to ascertain radiation-induced molecular changes in the lens focus on protein aggregation and gene/protein expression patterns. We anticipate that this study will contribute to our understanding of early molecular changes associated with radiation-induced tissue pathology. This study also affords potential for translational development of molecular biodosimetry instrumentation to assess human exposure to mixed radiation fields.

01 COAL, LIGNITE, AND PEAT↗

Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

54 ENVIRONMENTAL SCIENCES↗

Computational Model of Heat Transfer on the ISS

SCRAM Lite (SCRAM signifies Station Compact Radiator Analysis Model) is a computer program for analyzing convective and radiative heat-transfer and heat-rejection performance of coolant loops and radiators, respectively, in the active thermal-control systems of the International Space Station (ISS). SCRAM Lite is a derivative of prior versions of SCRAM but is more robust. SCRAM Lite computes thermal operating characteristics of active heat-transport and heat-rejection subsystems for the major ISS configurations from Flight 5A through completion of assembly. The program performs integrated analysis of both internal and external coolant loops of the various ISS modules and of an external active thermal control system, which includes radiators and the coolant loops that transfer heat to the radiators. The SCRAM Lite run time is of the order of one minute per day of mission time. The overall objective of the SCRAM Lite simulation is to process input profiles of equipment-rack, crew-metabolic, and other heat loads to determine flow rates, coolant supply temperatures, and available radiator heat-rejection capabilities. Analyses are performed for timelines of activities, orbital parameters, and attitudes for mission times ranging from a few hours to several months.

Torian, John G.↗