Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Uranus Flagship-class Orbiter and Probe Using Aerocapture

Exploration of the Ice Giants, especially Uranus, via orbiter and atmospheric probes, is required to answer pressing science questions that have been raised in the latest National Academies of Sciences Planetary Decadal Survey. Since the Ice Giants are the farthest planets from Earth, traditional fully-propulsive orbit insertion missions have transit times to the planetary bodies bordering 13-15 years and require a large amount of propellant (wet mass percentages of around 60-70%) for the orbit insertion maneuver, leaving less mass for the scientific payload and a planetary probe. Aerocapture uses aerodynamic forces generated by flight within a planetary atmosphere to decelerate and achieve orbit insertion. Aerocapture has been considered for several past missions but it has not been demonstrated. However, recent developments in thermal protection systems (TPS), guidance and control (G&C), and interplanetary navigation capabilities show the potential for using rigid, heritage entry vehicle configurations already flown at other planetary bodies for Ice Giants aerocapture. Aerocapture can robustly deliver spacecraft to Ice Giant orbits, while substantially increasing on-orbit payload mass (more than 40%) that can be used for a robust atmospheric entry probe. Additionally, the aerocapture maneuver would reduce the interplanetary transit time by 2-5 years (15-30%) relative to fully-propulsive orbit insertion. Recent work has shown that a flagship-class mission can be conducted in a shorter time than fully-propulsive missions if using aerocapture. This paper will consider the merits of including aerocapture as the orbit-insertion mechanism for a Uranus mission. Specifically, the implications of aerocapture orbit insertion for in-situ atmospheric probes will be discussed. The Uranus Orbiter and Probe concept mission study [3] is considered as the potential payload. Results from a recent NASA Space Technology Mission Directorate (STMD)-funded activity that is designing an aerocapture mission for a Uranus orbiter will be presented.

Soumyo Dutta↗

AFM fluid delivery/liquid extraction surface sampling/electrostatic spray cantilever probe

An electrospray system comprises a liquid extraction surface sampling probe. The probe comprises a probe body having a liquid inlet and a liquid outlet, and having a liquid extraction tip. A solvent delivery conduit is provided for receiving solvent liquid from the liquid inlet and delivering the solvent liquid to the liquid extraction tip. An open liquid extraction channel extends across an exterior surface of the probe body from the liquid extraction tip to the liquid outlet. An electrospray emitter tip is in liquid communication with the liquid outlet of the liquid extraction surface sampling probe. A system for analyzing samples, a liquid junction surface sampling system, and a method of analyzing samples are also disclosed.

36 MATERIALS SCIENCE↗

Sparse sampling and reconstruction for electron and scanning probe microscope imaging

Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

General Mode Scanning Probe Microscopy

A critical part of SPM measurements is the information transfer from the probe-sample junction to the measurement system. Current information transfer methods heavily compress the information-rich data stream by averaging the data over a time interval, or via heterodyne detection approaches such as lock-in amplifiers and phase-locked loops. As a consequence, highly valuable information at the sub-microsecond time scales or information from frequencies outside the measurement band is lost. We have developed a fundamentally new approach called General Mode (G-mode), where we can capture the complete information stream from the detectors in the microscope. The availability of the complete information allows the microscope operator to analyze the data via information-theory analysis or comprehensive physical models. Furthermore, the complete data stream enables advanced data-driven filtering algorithms, multi-resolution imaging, ultrafast spectroscropic imaging, spatial mapping of multidimensional variability in material properties, etc. Though we applied this approach to scanning probe microscopy, the general philosophy of G-mode can be applied to many other modes of microscopy. G-mode data is captured by completely custom software written in LabVIEW and Matlab. The software generates the waveforms to electrically, thermally, or mechanically excite the SPM probe. It handles real-time communications with the microscope software for operations such as moving the SPM probe position and also controls other instrumentation hardware. The software also controls multiple variants of high-speed data acquisition cards to excite the SPM probe with the excitation waveform and simultaneously measure multiple channels of information from the microscope detectors at sampling rates of 1-100 MHz. The software also saves the raw data to the computer and allows the microscope operator to visualize processed or filtered data during the experiment. The software performs all these features while offering a user-friendly interface.

Somnath, Suhas↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

Cooks, Robert Graham↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bile salt hydrolase probe and method of making and using the same

Probe embodiments for targeting, identifying, and isolating enzymes exhibiting BSH activity as well as devices and kits that use the probes are described herein. Methods of making and using the probes, devices, and kits are also described. In some embodiments, probes, devices, and kits for targeting, identifying, and isolating enzymes in a biological sample are disclosed. In some embodiments, compositions and methods of treatment using the probes, devices, and kits disclosed herein are described.

Wright, Aaron T.↗

Science of the Van Allen Probes Science Operations Centers

The Van Allen Probes mission operations materialized through a distributed model in which operational responsibility was divided between the Mission Operations Center (MOC) and separate instrument specific SOCs. The sole MOC handled all aspects of telemetering and receiving tasks as well as certain scientifically relevant ancillary tasks. Each instrument science team developed individual instrument specific SOCs proficient in unique capabilities in support of science data acquisition, data processing, instrument performance, and tools for the instrument team scientists. In parallel activities, project scientists took on the task of providing a significant modeling tool base usable by the instrument science teams and the larger scientific community. With a mission as complex as Van Allen Probes, scientific inquiry occurred due to constant and significant collaboration between the SOCs and in concert with the project science team. Planned cross-instrument coordinated observations resulted in critical discoveries during the seven-year mission. Instrument cross-calibration activities elucidated a more seamless set of data products. Specific topics include post-launch changes and enhancements to the SOCs, discussion of coordination activities between the SOCs, SOC specific analysis software, modeling software provided by the Van Allen Probes project, and a section on lessons learned. One of the most significant lessons learned was the importance of the original decision to implement individual team SOCs providing timely and well-documented instrument data for the NASA Van Allen Probes Mission scientists and the larger magnetospheric and radiation belt scientific community.

47 OTHER INSTRUMENTATION↗

Van Allen Probes observations of electromagnetic ion cyclotron waves triggered by enhanced solar wind dynamic pressure

Magnetospheric compression due to impact of enhanced solar wind dynamic pressure P dyn has long been considered as one of the generation mechanisms of electromagnetic ion cyclotron (EMIC) waves. Here, with the Van Allen Probe-A observations, we identify three EMIC wave events that are triggered by P dyn enhancements under prolonged northward interplanetary magnetic field (IMF) quiet time preconditions. They are in contrast to one another in a few aspects. Event 1 occurs in the middle of continuously increasing P dyn while Van Allen Probe-A is located outside the plasmapause at postmidnight and near the equator (magnetic latitude (MLAT) ~ -3°). Event 2 occurs by a sharp P dyn pulse impact while Van Allen Probe-A is located inside the plasmapause in the dawn sector and rather away from the equator (MLAT ~ 12°). Event 3 is characterized by amplification of a preexisting EMIC wave by a sharp P dyn pulse impact while Van Allen Probe-A is located outside the plasmapause at noon and rather away from the equator (MLAT ~ -15°). These three events represent various situations where EMIC waves can be triggered by P dyn increases. Several common features are also found among the three events. (i) The strongest wave is found just above the He + gyrofrequency. (ii) The waves are nearly linearly polarized with a rather oblique propagation direction (~28° to ~39° on average). (iii) The proton fluxes increase in immediate response to the P dyn impact, most significantly in tens of keV energy, corresponding to the proton resonant energy. (iv) The temperature anisotropy with T ⊥ > T || is seen in the resonant energy for all the events, although its increase by the P dyn impact is not necessarily always significant. Finally, the last two points (iii) and (iv) may imply that in addition to the temperature anisotropy, the increase of the resonant protons must have played a critical role in triggering the EMIC waves by the enhanced P dyn impact.

79 ASTRONOMY AND ASTROPHYSICS↗

A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and {sup 64}Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescence signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.

60 APPLIED LIFE SCIENCES↗

Thermalization of the Kerr index of refraction in acetone and methanol using femtosecond pump-probe scattering spectroscopy

Femtosecond time-resolved pump-probe scattering is used to temporally investigate the index thermalization Δn(t) of the molecular motions associated with the Kerr nonlinear index n 2 . This is done using an intense 300 fs 1034 nm pump pulse and temporally probed by a 517 nm and supercontinuum pulse in acetone and methanol. The optically pumped molecular states change the index of refraction and through the processes of Raman and Rayleigh scattering are shown to engage in a 4-step energy relaxation process. Here, the pump first initiates the Kerr effect as well as populate resonant vibrational molecular motions, which act as a “mother” energy state. The electronic component of the Kerr effect is shown to couple with these vibrational modes through the process of Born-Oppenheimer coupling, which can be measured through the Raman scattering of the probe. The “mother” coupled state then decays into “daughter” anharmonic non-resonant states, which then further decay into “granddaughter” and thermal bath states. The population of these states alter the index of refraction in time, Δn(t), and can be measured through the changing in the probe beam’s Rayleigh scattering. This thermalization process takes ~5.5 ps in acetone and ~3.7 ps in methanol. The scattering signals from each Δn(t) thermalization stage in the localized region, (“mother”, to “daughter”, to “granddaughter”, to the bath states, to the ground state), are fitted to theoretical decay equations that show the rise and fall times of the energy decay routes.

47 OTHER INSTRUMENTATION↗

Impacts of Focused Ion Beam Processing on the Fabrication of Nanoscale Functionalized Probes

Herein, we examine the impact of Ga + ion kinetic energy and the target material type on the extent of ion implantation and structural damage in atomic force microscopy probes made of Al 2 O 3 and ZnO manufactured by focused ion beam (FIB) using scanning transmission electron microscopy and energy-dispersive X-ray mapping. Penetration of Ga into the Al 2 O 3 lattice induced structural distortions and amorphization. For ZnO probes, Ga is uniformly dispersed across the surface, resulting in the formation of distinct clusters. Atom probe tomography further validates the Ga distributions in Al 2 O 3 and ZnO nanoprobes. Complementary Monte Carlo simulations with the transport of ions in the matter program indicated that the introduction of Ga + prompts the generation of cation and anion vacancies, an occurrence more pronounced in Al 2 O 3 compared to ZnO. In conclusion, this study not only enriches the knowledge of ion-matter interactions, but also serves as a practical guide for the fabrication of nanoscale functionalized AFM probes.

Al2O3↗

Relaxation Dynamics of Hydrated Thymine, Thymidine, and Thymidine Monophosphate Probed by Liquid Jet Time-Resolved Photoelectron Spectroscopy

In this work, the relaxation dynamics of thymine and its derivatives thymidine and thymidine monophosphate are studied using time-resolved photoelectron spectroscopy applied to a water microjet. Two absorption bands are studied; the first is a bright ππ* state which is populated using tunable-ultraviolet light in the range 4.74–5.17 eV and probed using a 6.20 eV probe pulse. By reversing the order of these pulses, a band containing multiple ππ* states is populated by the 6.20 eV pulse and the lower energy pulse serves as the probe. The lower lying ππ* state is found to decay in ~400 fs in both thymine and thymidine independent of pump photon energy, while thymidine monophosphate decays vary from 670 to 840 fs with some pump energy dependence. The application of a computational quantum mechanical/molecular mechanical scheme at the XMS-CASPT2//CASSCF/AMBER level of theory suggests that conformational differences existing between thymidine and thymidine monophosphate in solution account for this difference. The higher lying ππ* band is found to decay in ~600 fs in all three cases, but it is only able to be characterized when the 5.17 eV probe pulse is used. Notably, no long-lived signal from an nπ* state can be identified in either experiment on any of the three molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Johnson-noise-limited cancellation-free microwave impedance microscopy with monolithic silicon cantilever probes

Abstract Microwave impedance microscopy (MIM) is an emerging scanning probe technique for nanoscale complex permittivity mapping and has made significant impacts in diverse fields. To date, the most significant hurdles that limit its widespread use are the requirements of specialized microwave probes and high-precision cancellation circuits. Here, we show that forgoing both elements not only is feasible but also enhances performance. Using monolithic silicon cantilever probes and a cancellation-free architecture, we demonstrate Johnson-noise-limited, drift-free MIM operation with 15 nm spatial resolution, minimal topography crosstalk, and an unprecedented sensitivity of 0.26 zF/ √ Hz. We accomplish this by taking advantage of the high mechanical resonant frequency and spatial resolution of silicon probes, the inherent common-mode phase noise rejection of self-referenced homodyne detection, and the exceptional stability of the streamlined architecture. Our approach makes MIM drastically more accessible and paves the way for advanced operation modes as well as integration with complementary techniques.

47 OTHER INSTRUMENTATION↗

Simultaneous use of camera and probe diagnostics to unambiguously identify and study the dynamics of multiple underlying instabilities during the route to plasma turbulence

We use multiple-tip Langmuir probes and fast imaging to unambiguously identify and study the dynamics of underlying instabilities during the controlled route to fully-developed plasma turbulence in a linear magnetized helicon plasma device. Langmuir probes measure radial profiles of electron temperature, plasma density and potential; from which we compute linear growth rates of instabilities, cross-phase between density and potential fluctuations, Reynold's stress, particle flux, vorticity, time-delay estimated velocity, etc. Fast imaging complements the 1D probe measurements by providing temporally and spatially resolved 2D details of plasma structures associated with the instabilities. We find that three radially separated plasma instabilities exist simultaneously. Density gradient driven resistive drift waves propagating in the electron diamagnetic drift direction separate the plasma into an edge region dominated by strong, velocity shear driven Kelvin-Helmholtz instabilities and a central core region which shows coherent Rayleigh-Taylor modes propagating in the ion diamagnetic drift direction. The simultaneous, complementary use of both probes and camera was crucial to identify the instabilities and understand the details of the very rich plasma dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tracing ultrafast dynamics of strong fields at plasma-vacuum interfaces with longitudinal proton probing

If regions of localized strong fields at plasma-vacuum interfaces are probed longitudinally with laser accelerated proton beams their velocity distribution changes sensitively and very fast. Its measured variations provide indirectly a higher temporal resolution as deduced from deflection geometries which rely on the explicit temporal resolution of the proton beam at the position of the object to probe. With help of reasonable models and comparative measurements changes of proton velocity can trace the field dynamics even at femtosecond time scale. In longitudinal probing, the very low longitudinal emittance together with a broad band kinetic energy distribution of laser accelerated protons is the essential prerequisite of the method. With a combination of energy and one-dimensional spatial resolution, we resolve fast field changes down to 100 fs. The used pump probe setup extends previous schemes and allows discriminating simultaneously between electric and magnetic fields in their temporal evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Numerical matching of the sheath and presheath solutions for a spherical probe in radial-motion theory

The theory of positive-ion collection by a probe immersed in a low-pressure plasma was reviewed and extended by Allen, Boyd, and Reynolds [Proc. Phys. Soc. 70, 297 (1957)]. For a given value of the ion current, the boundary values of the matched “nonneutral” or “sheath” solution V{sup ~}{sub nn}{sup (m)}(r; r{sub m}) were obtained from the “quasineutral” or “presheath” solution V{sup ~}{sub qn}(r) by choosing the small potential and electric-field values corresponding to some large “matching radius” r{sub m}. Here, a straightforward but efficient numerical method is presented for systematically determining an optimal value of the matching radius at which the presheath and sheath solutions are joined to yield the “matched” potential profile. Some suitable initial matching radius r{sub m1} is chosen and the related potential and electric-field values of the quasineutral solution are calculated. Using these as boundary conditions, Poisson's equation is integrated to yield the matched nonneutral solution including the corresponding potential at the probe surface. This procedure is repeated for increasing values r{sub m2}, r{sub m3},…. until the resulting potential at the probe surface becomes practically constant. The corresponding value of r{sub m} is taken as the “optimal” matching radius r{sub mo} at which the presheath and sheath solutions are ultimately joined to yield the “optimal” matched potential profile in the entire plasma-probe transition region. It is also shown that the Bohm criterion is inapplicable in the present problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗