Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Time and position resolution of the scintillator strips for a muon system at future colliders

In this study, prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A linear array of position-sensitive virtual Frisch-grid CdZnTe for low-energy gamma rays

Large-area arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution and high efficiency have been proposed for spectroscopy and imaging of gamma-ray sources. We present the design and test results of a linear array of such detectors optimized for use in handheld instruments. There are several application areas for such detectors including uranium enrichment measurements, storage monitoring, dosimetry and other nuclear safeguards related tasks. The array configuration provides a large area with minimum number of readout channels, which potentially allows the developers to avoid using ASIC-based readout electronics by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of 6 5 x 7 x 25 mm 3 CZT detectors side-oriented with respect to the source to achieve the maximum area. Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. As an option, the pads can be grouped together to reduce the number of readout channels. The same can be done with the cathodes. The pads signals are converted into X–Y coordinates and combined with the cathode signals (for the Z coordinates) to give 3D positional information of each interaction point. This information is used to correct the response non-uniformity caused by material inhomogeneity, which allows the developers to use standard grade (unselected) CZT crystals, while retaining high spectroscopic performance.

3D position-sensitive virtual Frisch-grid detector↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IsoForma: An R Package for Quantifying and Visualizing Positional Isomers in Top-Down LC-MS/MS Data

Proteoforms, the different forms of a protein with sequence variations including post-translational modifications (PTMs), execute vital functions in biological systems such as cell signaling and epigenetic regulation. Precisely defining the stoichiometry of PTMs has been challenging because, in the widely used bottom-up proteomics methods, the detection occurs at the peptide level and thus the link between peptides and their specific modification site is lost, resulting in proteoform ambiguity. Advances in top-down mass spectrometry (MS) technology have permitted the direct characterization of intact proteoforms and their exact number of modification sites, allowing for the relative quantification of positional isomers (PI). Proteins with positional isomers refers to proteoforms with identical total mass and set of modifications but varying PTM site combinations. The relative abundance of PI can be estimated by matching proteoform-specific fragment ions to top-down tandem MS (MS2) data to localize and quantify modifications. However, current approaches heavily rely on manual annotation. Here, we present IsoForma, an open-source R package for relative quantification of PI within a single tool. We benchmarked IsoForma’s performance against two existing workflows and highlight the similarity of the results and improvements in speed. Overall, IsoForma provides a streamlined process, reduces the time of conducting isoform-based analyses, and offers an essential framework for developing customized proteoform analysis workflows. Finally, the software is open source and available at https://github.com/EMSL-Computing/isoforma-lib.

59 BASIC BIOLOGICAL SCIENCES↗

Single Crystalline Na 0.67 Ni 0.33 Mn 0.67 O 2 Positive Electrode Material via Molten Salt Synthesis for Sodium Ion Batteries

P2-layered Na 0.67 Ni 0.33 Mn 0.67 O 2 (NNMO) has emerged as a promising positive electrode material for sodium ion batteries due to its appealing electrochemical properties. Synthesis of polycrystalline NNMO (PC-NNMO) materials through conventional calcination of solid precursors remains the prevailing method, where heating occurs in a dry environment with air or O 2 . On the other hand, the molten salt method, where precursors are submerged in molten salt medium during calcination, emerged in recent years to be a scalable technique for more controlled crystal growth and uniform morphology in a variety of materials. Here, we utilize the molten salt method to synthesize single crystalline NNMO (SC-NNMO) materials with enhanced electrochemical properties. The SC-NNMO material exhibits an initial specific discharge capacity of 95 mAh g –1 at a 0.1C rate, retaining approximately 88.5% of its capacity after 100 cycles over a wide voltage range of 2.0–4.2 V. Furthermore, SC-NNMO maintains a capacity retention of 83.9% after 300 cycles at a 1C rate compared to 66.6% for PC-NNMO, indicating excellent long-term cycling stability. This stability is further confirmed by the performance of an SC-NNMO//hard carbon full cell, which retains 90.3% of its capacity after 200 cycles at 1C within a voltage window of 1.9–4.1 V. The enhancement in stability of the SC-NNMO sample is attributed to the single crystalline structure suppressing the undesired P2–O2 phase transition at high voltage. This study also presents an easy, efficient, and straightforward molten salt process for SC-NNMO material synthesis, offering valuable insights into the potential application of such methodology for the large-scale, cost-effective production of various sodium-layered transition metal oxide positive electrode materials for SIBs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of the positioning force of electrostatic levitators on viscosity measurements

Electrostatic levitators use strong electric fields to levitate and accurately position a sample against gravity. In this study, the effects of the electric field are investigated with regard to viscosity measurements conducted with the oscillating drop method. The effects of the external field on viscosity measurements are experimentally confirmed by changing the sample size. Moreover, a numerical simulation based on a simple mass-spring-damper system can reproduce the experimental observations. Based on the above results, measurement procedures are improved. These help to minimize the effect of the positioning force and to increase the accuracy of the viscosity measurements.

36 MATERIALS SCIENCE↗

An Efficient Referencing And Sample Positioning System To Investigate Heterogeneous Substances With Combined Microfocused Synchrotron X-ray Techniques

A referencing and sample positioning system has been developed to transfer object positions measured with an offline microscope to a synchrotron experimental station. The accuracy should be sufficient to deal with heterogeneous samples on micrometer scale. Together with an online fluorescence mapping visualisation the optical alignment helps to optimize measuring procedures for combined microfocused X-ray techniques.

39↗

In situ positioning of a few hundred micrometer-sized cleaved surfaces for soft-x-ray angle-resolved photoemission spectroscopy by use of an optical microscope

A method to position samples with small cleaved regions has been developed to be applied to the angle-resolved photoemission spectroscopy (ARPES) which uses soft-x-ray synchrotron radiation focused down to 160x180 {mu}m{sup 2}. A long-working-distance optical microscope is used for the sample observation. A selected region on a sample can be optimally set at the position of measurements, which is realized by the spatial resolution of the photoelectron analyzer. Using this method, electronic band dispersions of bulk silicon have been measured by ARPES for a partially cleaved region with a size of {approx}200x500 {mu}m{sup 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Errors in Patient Positioning on Resulting Dose Distribution during IMRT Treatment for Head and Neck Area

Intensity modulated radiotherapy (IMRT) irradiation technique uses steep dose gradients to protect organs at risk (OAR) during treatment course. Therefore even small mistakes in patient positioning during treatment course may lead to significant changes in dose distribution. The influence of small errors (order of millimeters) in patient's positioning on resulting dose absorbed in OARs and target volume (PTV, GTV) was simulated in this work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of X-ray Beam Position Monitors for Superconducting Wiggler

For the development of an X-ray beam position monitor (XBPM) for the superconducting wiggler (SW) at the NSRRC, two XBPM are installed in the SW front end. The blades of the XBPM were manufactured with material of three types; tungsten, Glidcop and aluminium, to test the effect of the material on the performance of the XBPM. These three materials are compared with blades of molybdenum that were previously installed. The vibration and thermal expansion of the pillar of a XBPM affects the position reading of the XBPM. For pillars of XBPM of various designs, each type has a distinct thermal isolating material and is filled with a separate damping material for comparison. The design requirements of these XBPM include high spatial resolution of the monitor and mechanical stability of the structure with a large thermal load. The design, fabrication and measurement results are presented here.

43 PARTICLE ACCELERATORS↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

Performance of BF{sub 3} Filled Position Sensitive Neutron Detector

{sup 3}He filled position sensitive detectors (PSD)s developed in-house are successfully used for neutron scattering studies at Dhruva. However recent global scarcity of {sup 3}He has made it essential to find an alternative. It is very difficult to meet performance capabilities of {sup 3}He for neutron detection in any of the alternate materials. Among various alternatives, BF{sub 3} gas can be one. We have recently put an effort to evaluate performance of BF{sub 3} based PSD. For that a PSD filled with BF{sub 3} gas at 0.8 bar pressure is fabricated and characterized. Performances of the same with Pu-Be source and at Hi-Q Diffractometer, Dhruva are reported in this paper. Diffraction spectra from standard samples Fe and Si at wavelength 0.783 A were recorded. It is found that while position resolution of the BF{sub 3} filled PSD is comparable but the efficiency is 20 times less than that of a {sup 3}He(12 bar) filled PSD.

36 MATERIALS SCIENCE↗

The physical nature of the phenomenon of positive column plasma constriction in low-pressure noble gas direct current discharges

The essence of the positive-column plasma constriction for static (the diffusion mode) and dynamic ionization equilibrium (the stratificated and constricted modes) is analyzed. Two physical parameters, namely, the effective ionization rate of gas atoms and the ambipolar diffusion coefficient of electrons and ions, determine the transverse distribution of discharge species and affect the current states of plasma. Transverse constriction of the positive column takes place as the gas ionization level (discharge current) and pressure increase. The stratified mode (including the constricted one) is observed between the two adjacent types of self-sustained discharge phases when they coexist together at the same time or in the same place as a coherent binary mixture. In the case, a occurrence of the discharge phase with more high electron density presently involve a great decrease in the cross-section of the current channel for d.c. discharges. Additional physical factors, such as cataphoresis and electrophoresis phenomena and spatial gas density inhomogeneity correlated with a circulatory flow in d.c. discharges, are mainly responsible for the current hysteresis and partially constricted discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid monitor for both beam position and tilt of pulsed high-current beams

A Hybrid beam monitor, integrated with both azimuthal and axial B-dot probes, was designed for simultaneous measurement of both beam position and beam angle for pulsed high-current beams at the same location in beam pipe. The output signals of axial B-dot probes were found to be mixed with signals caused by transverse position deviation. In order to eliminate the unwanted signals, an elimination method was developed and its feasibility tested on a 50-Ω coaxial line test stand. By this method, a waveform, shape-like to that of input current and proportional to the tilt angle, was simulated and processed by following integration step to achieve the tilt angle. The tests showed that the measurement error of displacement and tilt angle less than 0.3 mm and 1.5 mrad, respectively. The latter error could be reduced with improved probes by reducing the inductance of the axial B-dot probe, but the improvement reached a limit due to some unknown systemic mechanism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and amplitude

A new multi-particle time and position sensitive detector using only a set of microchannel plates, a waveform digitizer, a phosphor screen, and a CMOS camera is described. The assignment of the timing information, as taken from the microchannel plates by fast digitizing, to the positions, as recorded by the camera, is based on the COrrelation between the BRightness of the phosphor screen spots, defined as their integrated intensity and the Amplitude of the electrical signals (COBRA). Tests performed by observing the dissociation of HeH, the fragmentation of H{sub 3} into two or three fragments, and the photo-double-ionization of Xenon atoms are presented, which illustrate the performances of the COBRA detection scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The total position-spread tensor: Spin partition

The Total Position Spread (TPS) tensor, defined as the second moment cumulant of the position operator, is a key quantity to describe the mobility of electrons in a molecule or an extended system. In the present investigation, the partition of the TPS tensor according to spin variables is derived and discussed. It is shown that, while the spin-summed TPS gives information on charge mobility, the spin-partitioned TPS tensor becomes a powerful tool that provides information about spin fluctuations. The case of the hydrogen molecule is treated, both analytically, by using a 1s Slater-type orbital, and numerically, at Full Configuration Interaction (FCI) level with a V6Z basis set. It is found that, for very large inter-nuclear distances, the partitioned tensor growths quadratically with the distance in some of the low-lying electronic states. This fact is related to the presence of entanglement in the wave function. Non-dimerized open chains described by a model Hubbard Hamiltonian and linear hydrogen chains H{sub n} (n ≥ 2), composed of equally spaced atoms, are also studied at FCI level. The hydrogen systems show the presence of marked maxima for the spin-summed TPS (corresponding to a high charge mobility) when the inter-nuclear distance is about 2 bohrs. This fact can be associated to the presence of a Mott transition occurring in this region. The spin-partitioned TPS tensor, on the other hand, has a quadratical growth at long distances, a fact that corresponds to the high spin mobility in a magnetic system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response to “Comment on ‘Two-dimensional positive column structure in a discharge tube with radius discontinuity’” [Phys. Plasmas 22, 094701 (2015)]

For a quantitative validation of the nonlocal approach for simulation of positive column of dc gas discharge in neon, we have performed a comparative self-consistent calculations of parameters of longitudinally uniform positive column using two approaches—a full kinetic equation with a radially inhomogeneous electron distribution function (exact calculation) and a nonlocal approach. The calculations were performed for discharge current 1 mA and neon pressures 40 and 90 Pa. It is shown that discrepancies between parameters calculated with the two approaches—radial distributions of electron number densities, ionization rates, space potentials—are minor. Physical reasons of a validity of the nonlocal approach for present conditions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗