Epitaxially crystallized polyethylene exhibiting near-equilibrium melting temperatures*
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
No abstract prepared.
One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.
Particles composed of organic and inorganic components can assume core-shell morphologies. The kinetic limitation of water uptake due to the presence of a hydrophobic viscous outer shell may increase the critical supersaturation required to activate such particles into cloud droplets. Here we test this hypothesis through laboratory experiments. Results show that the viscosity of polyethylene particles is 5×10 6 Pa s at 60°C. Extrapolation of temperature dependent viscosity measurements suggests that the particles are glassy at room temperature. Cloud condensation nuclei (CCN) activity measurements demonstrate that pure polyethylene particles are CCN inactive at diameters less than 741 nm and 2.5 % water supersaturation. Thus, polyethylene is used as proxy for hydrophobic glassy organic material. Ammonium sulfate is used as proxy for hygroscopic CCN active inorganic material. Mixed particles were generated using coagulation of oppositely charged particles; charge-neutral polyethylene–ammonium sulfate dimer particles were then isolated for online observation. Morphology of these dimer particles was varied by heating, such that liquefied polyethylene partially or completely engulfed the ammonium sulfate. Critical supersaturation was measured as a function of dry particle volume, particle morphology, and organic volume fraction. The data show that kinetic limitations do not change the critical supersaturation of 50 nm ammonium sulfate cores coated with polyethylene and polyethylene volume fractions up to 97 %. Based on these results, and a synthesis of literature data, it is suggested that mass transfer limitations by glassy organic shells are unlikely to affect cloud droplet activation near laboratory temperatures.
Recently, a cold moderator was designed and developed for use at the Rensselaer Polytechnic Institute Linear Accelerator (RPI LINAC). This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by up to a factor of 8 by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Furthermore, following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0005 – 1 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0005 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0005 – 1 eV for polystyrene and yttrium hydride.
To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.
Recently, a cold moderator was designed and developed for use at the RPI LINAC. This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0006 – 20 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0007 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0006 – 3 eV for polystyrene and yttrium hydride.
Chemical upcycling of waste polyolefins via hydrogenolysis offers unique opportunities for selective depolymerization compared to high temperature thermal deconstruction. Here, we demonstrate the hydrogenolysis of polyethylene into liquid alkanes under mild conditions using ruthenium nanoparticles supported on carbon (Ru/C). Reactivity studies on a model noctadecane substrate showed that Ru/C catalysts are highly active and selective for the hydrogenolysis of C(sp 3 )–C(sp 3 ) bonds at temperatures ranging from 200 to 250 °C. Under optimal conditions of 200 °C in 20 bar H 2 , polyethylene (average M w ~ 4000 Da) was converted into liquid n-alkanes with yields of up to 45% by mass after 16 h using a 5 wt % Ru/C catalyst with the remaining products comprising light alkane gases (C 1 –C 6 ). At 250 °C, nearly stoichiometric yields of CH 4 were obtained from polyethylene over the catalyst. The hydrogenolysis of long chain, low-density polyethylene (LDPE) and a postconsumer LDPE plastic bottle to produce C 7 –C 45 alkanes was also achieved over Ru/C, demonstrating the feasibility of this reaction for the valorization of realistic postconsumer plastic waste. By identifying Ru-based catalysts as a class of active materials for the hydrogenolysis of polyethylene, this study elucidates promising avenues for the valorization of plastic waste under mild conditions.
This study demonstrates a new method of radioisotope labeling of ultra-high molecular weight polyethylene inserts in prosthetic joints for wear studies. The radioisotopes {sup 97}Ru, {sup 100}Pd, {sup 100}Rh, and {sup 101m}Rh are produced in fusion evaporation reactions induced by {sup 12}C ions in a {sup 92}Zr target foil. The fusion products recoil-implant into ultra-high molecular weight polyethylene plugs, machined to fit into the surface of the inserts. During laboratory simulations of the joint motion, a wear rate of the labeled polyethylene may be measured and the pathways of wear debris particles can be traced by detecting characteristic gamma-rays. The concentration profiles of the radioisotopes extend effectively uniformly from the polyethylene surface to a depth of about 4 {mu}m. The multiplicity of labeling and the use of several gamma-ray lines aids with avoiding systematic measurement uncertainties. Two polyethylene plugs were labeled and one was fitted into the surface of the tibial insert of a knee prosthesis, which had been worn in. Actuation over close to 100,000 cycles with a 900 N axial load and a 24 deg. flexion angle removed (14{+-}1)% of the gamma-ray activity from the plug. Most of this activity dispersed into the serum lubricant identifying this as the important debris pathway. Less than 1% activity was transferred to the femoral component of the prosthesis and the measured activity on the tibial tray was insignificant. Assuming uniform wear across the superior surface of the insert, a wear rate of (12{+-}3) mm{sup 3}/Megacycle was determined. This is consistent with wear rate measurements under similar conditions using other techniques.
The preparation of cross-linked polyethylene with high energy electrons is a well-known and used method to change material properties [1-6]. A new developed technique called “Electron induced reactive processing” simultaneously combines polymer modification with high energy electrons and melt mixing processes [7-13]. In the case of polyethylene, this novel technique leads to exceptional mechanical properties. Definitely, these properties depend on the molecular architecture as well as the morphological characteristics of polyethylene after the electron treatment. In this work we concentrate on the morphological changes of high density polyethylene generated by using state of the art high energy electron treatment in the solid state compared with high density polyethylene modified with the electron induced reactive processing.
A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)
Given increasing concerns for the marine environment and human health, as well as trade restrictions from Asian countries, plastics have become a great challenge for the United States. This study addresses the seven commonly used plastics: low-density polyethylene/linear low-density polyethylene, high-density polyethylene, polyethylene terephthalate (PET), polypropylene, polystyrene, polyvinyl chloride, and other plastics. Material flows of the seven polymers were tracked from production into fabrication, manufacturing, flow into use, waste management, and recycling in the United States in 2015. Low- and high-density polyethylene and polypropylene were found to be the largest in both production and product manufacture. More than 88% of the plastics went into three end-use sectors: Packaging, Consumer and Institutional Products, and Building and Construction. In-use lifetimes across the plastics are generally short. Virgin plastics were mainly exported, while intermediate plastic products were largely imported. The actual end-of-life recycling rate of the plastics as a group was no more than 6.2%, with PET and the polyethylene family the most recycled. Here, the high yearly plastic throughput and low recycling rate pose a serious challenge to the sustainability goals of the United States and is in stark contrast to the vision of a circular economy of plastics.
The management of plastic waste is a considerable emerging global concern. Conventional plastics recycling rates range from 5–10% in the US, which results in considerable material being sent to landfill. New sorting technologies using artificial intelligence have the potential to dramatically increase the ability of waste management companies to sort out valuable fractions of plastic waste and create high-purity streams for secondary markets. However, several fractions of the plastics recycling stream, i.e., low-density polyethylene, polypropylene, and polystyrene, do not have well-developed markets. These materials may be sent to pyrolysis facilities for thermal recycling, but the economics of the pyrolysis industry are currently uncertain. This work aims to identify the breakeven price of the plastic fractions that would be sent to pyrolysis in order to determine the economic viability of the sorting facility. The work will use Monte Carlo analysis to evaluate several scenarios and understand how compositional variation, price variability, and facility attributes affect the breakeven price. Here, the presorting conditions in Materials Recovery Facilities strongly affects the profitability of the sorting facility. High residual high density polyethylene (HDPE) and polyethylene terephthalate (PET) content in presorted bales are important revenue drivers for the facility, even in presorted 3-7 bales. Key variables that lead to profitability include a high sale price of polyethylene terephthalate, a high sale price of high-density polyethylene, and if polypropylene can be sold to recycling markets (as opposed to pyrolysis facilities).
Selective Laser Sintering (SLS) uses a precisely controlled laser to fuse polymer powder to build complex 3D shapes. While SLS covers a wide application space, the processing knowledge of polymer powder is limited, restricting the number of commercial powders available. This study serves to expand the processing knowledge of polypropylene and polyethylene in parallel with a “mature” SLS feedstock, nylon, through melt flow index (MFI) characterization. Differential Scanning Calorimetry (DSC) was used to explore the sintering window of the polymers. Polyethylene and polypropylene exhibited a relatively narrow sintering window between 4 – 5 °C, whereas the sintering window of nylon was much wider, between 23 – 24 °C. This suggests that the print quality between polyethylene and polypropylene would be similar; however, X-ray computed tomography revealed a higher volume of print defects, voids, and de lamination in polyethylene than in polypropylene. MFI analysis provided additional insight into the difference in print quality, as the MFI of polyethylene was 7.16 g/10 min, 9.95 g/10 min for polypropylene, and 17.23 g/10 min for nylon. MFI is inversely correlated to melt viscosity, and a low melt viscosity is desired for proper coalescing between the layers and particles. These results suggest that MFI is a promising tool, in conjunction with traditional thermal analysis, for screening candidate powder feedstocks for SLS and optimization of print parameters for novel powders.
A laser ion source can provide wide variety of ion beams from solid target materials, however, it has been difficult to create proton beam efficiently. We examined capability of proton production using beeswax, polyethylene, and metal hydrides (MgH2 and ZrH2) as target materials. The results showed that beeswax and polyethylene could not be used to produce protons because these targets are transparent to the laser wavelength of 1064 nm. On the other hand, the metal hydrides could supply protons. Although the obtained particle numbers of protons were less than those of the metal ions, the metal hydrides could be used as a target for proton laser ion source.