Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A Comparative Evaluation of Additive Manufactured Stainless Steel Test Pieces

Stainless steel is used for variety of applications with different grades, alloys, filaments and powders. Additive manufacturing (AM) enables unique design features and refined microstructures. Performance testing on AM parts are needed as input to modeling and accelerated qualification processes. The objective of this work is to determine the effect of surface roughness on corrosion rate for from different manufacturers Preliminary evaluation shows that the 500-hour data set was scattered, and trend analysis are complex, while the 1000h and 1500h test results evaluation show more distinct trends.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a plasma driven permeation experiment for TPE

Experiments on retention of hydrogen isotopes (including tritium) at temperatures less than 800 ?C have been carried out in the Tritium Plasma Experiment (TPE) at Idaho National Laboratory [1,2]. To provide a direct measurement of plasma driven permeation in plasma facing materials at temperatures reaching 1000 ?C, a new TPE membrane holder has been built to hold test specimens (=1 mm in thickness) at high temperature while measuring tritium permeating through the membrane from the plasma facing side. This measurement is accomplished by employing a carrier gas that transports the permeating tritium from the backside of the membrane to ion chambers giving a direct measurement of the plasma driven tritium permeation rate. Isolation of the membrane cooling and sweep gases from TPE’s vacuum chamber has been demonstrated by sealing tests performed up to 1000 ?C of a membrane holder design that provides easy change out of membrane specimens between tests. Simulations of the helium carrier gas which transports tritium to the ion chamber indicate a very small pressure drop (~700 Pa) with good flow uniformity (at 1000 sccm). Thermal transport simulations indicate that temperatures up to 1000 ?C are expected at the highest TPE fluxes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of catalyst-coated membranes for enhancing performance in proton exchange membrane electrolyzer cells

To achieve large-scale application of proton exchange membrane electrolyzer cells (PEMECs) for hydrogen production, it is highly desirable to reduce the manufacturing cost while enhancing cell performance. In the PEMPECs, a catalyst-coated membrane (CCM) is the vital component where electrochemical reactions and mass transport mainly occur. The fabrication methods and catalyst layer (CL) structure can significantly affect the cell performance. Herein, for the first time, a comparative study of CCM fabrications with decal transfer and direct spray deposition methods have been conducted by both ex-situ materials characterization and in-situ performance testing in PEMECs. It is found CCMs that are fabricated with a direct spray deposition method display enhanced cell performance compared to CCMs fabricated with a decal transfer method, mainly due to the largely reduced ohmic resistance and improved mass transport. More importantly, cell performance can be greatly enhanced by simply regulating the Nafion ionomer content at the anode CL. The optimal Nafion ionomer content of 10 wt% gives the best cell performance at 80 °C with a low cell voltage of 1.887 V at 2 A cm -2 , outperforming the commercial CCM and most other previous publications. Our study provides a valuable guidance for fabrication and optimization of CCMs with significantly enhanced performance and reduced cost for practical application of the PEMECs.

08 HYDROGEN↗

Influence of topology optimization parameters on the mechanical response of an additively manufactured test structure

Topology Optimization (TO) determines a material distribution within a domain under given conditions and design constraints, and generally generates complex geometries as a result. Complementary to TO, Additive Manufacturing (AM) offers the ability to fabricate complex geometries which may be difficult to manufacture using traditional techniques such as milling. AM has been used in multiple industries including the medical devices area. Hence, TO may be used to create patient-matched devices where the mechanical response is catered to a particular patient. Furthermore, during a medical device regulatory 510(k) pathway, demonstrating that worst-cases are known and tested is critical to the review process. Using TO and AM to predict worst-case designs for subsequent performance testing may be challenging and does not appear to have been thoroughly explored. Investigating the effects of TO input parameters when AM is employed may be the first step in determining the feasibility of predicting these worst-cases.

36 MATERIALS SCIENCE↗

Impact of Microporous Layer Roughness on Gas-Diffusion-Electrode-Based Polymer Electrolyte Membrane Fuel Cell Performance

This study explores the role of the gas diffusion media microporous layer (MPL) surface structure on the electrochemical properties of gas-diffusion-electrode (GDE)-based membrane electrode assemblies (MEAs). It has been shown that a thin ionomer layer on top of the GDE and hot pressing is needed to create good contact between the catalyst layer and the membrane. In this study, gas diffusion media with different MPL surface roughness were applied to fabricate GDE-based MEAs to understand how MPL roughness impacts the amount of ionomer overlayer required for maximum performance. Electron microscopy was employed to investigate MPL/catalyst layer and catalyst layer/membrane interfaces. In-situ performance testing was used to assess the impact of MPL roughness and ionomer overlayer on catalyst utilization and air polarization performance. We find that a smoother MPL surface required a thinner ionomer overlayer than gas diffusion media (GDM) with a rougher MPL surface to achieve a performance comparable to direct-coated catalyst-coated-membrane MEAs.

36 MATERIALS SCIENCE↗

Development of soft X-ray polarized light beamline on Indus-2 synchrotron radiation source

This article describes the development of a soft x-ray beamline on a bending magnet source of Indus-2 storage ring (2.5 GeV) and some preliminary results of x-ray absorption spectroscopy (XAS) measurements using the same. The beamline layout is based on a spherical grating monochromator. The beamline is able to accept synchrotron radiation from the bending magnet port BL-1 of the Indus-2 ring with a wide solid angle. The large horizontal and vertical angular acceptance contributes to high photon flux and selective polarization respectively. The complete beamline is tested for ultrahigh vacuum (UHV) ∼ 10{sup −10} mbar. First absorption spectrum was obtained on HOPG graphite foil. Our performance test indicates that modest resolving power has been achieved with adequate photon flux to carry out various absorption experiments.

43 PARTICLE ACCELERATORS↗

Sierra/SolidMechanics 5.0 Example Problems Manual

Presented in this document are tests that exist in the Sierra/SolidMechanics example problem suite, which is a subset of the Sierra / SM regression and performance test suite. These examples showcase common and advanced code capabilities. A wide variety of other regression and verification tests exist in the Sierra / SM test suite that are not included in this manual.

97 MATHEMATICS AND COMPUTING↗

Los Alamos flux comperssion systems, ASI focus area I program plan

This document is a final summary of an original plan submitted as LA-UR 10-06693. There are minor revisions, some new items have been completed, and there is a statement of some funding shortfalls. Program plan focuses on using Ranchero Technology for the ASI 43 cm Ranchero generators are being fabricated to provide a small scale load and diagnostics test capability at Los Alamos - LLNL loads and Los Alamos multi-shell loads. 43 cm Ranchero tests continue as long as they are useful. 1 or 1.4 m Ranchero tests follow in the out years - Multi-shell loads have identified needs for full length generators and one 1.4 m generator is on hand. Both LLNL and Los Alamos loads will require larger current capability, and Ranchero will be scaled up in diameter when full scale current is defined. Increased scale tests expected in FY-12. The bulk of the Los Alamos Effort will be directed toward two thrusts: (1) Perform tests for LLNL load development and (2) explore multi-shell loads. ASC program assesses development against ASI results then provides new designs.

99 GENERAL AND MISCELLANEOUS↗

Characterization of front-end electronics for CZT based handheld radioisotope identifier

A radioisotope identifier device based on large volume Co-planar grid CZT detector is current under development at Malaysian Nuclear Agency. This device is planned to be used for in-situ identification of radioisotopes based on their unique energies. This work reports on electronics testing performed on the front-end electronics (FEE) analog section comprising charge sensitive preamplifier-pulse shaping amplifier chain. This test involves measurement of charge sensitivity, pulse parameters and electronics noise. This report also present some preliminary results on the spectral measurement obtained from gamma emitting radioisotopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress Towards Commercialization of Electrochemical Membrane Technology for CO2 Capture and Power Generation

To address the concerns about climate change resulting from emission of CO2 by coal-fueled power plants, FuelCell Energy, Inc. has developed Combined Electric Power and Carbon-dioxide Separation (CEPACS) system concept, as a novel solution for greenhouse gas emission reduction. The CEPACS system utilizes Electrochemical Membrane (ECM) technology derived from the Company’s well established Direct FuelCell® products. The system concept works as two devices in one: it separates the CO2 from the exhaust of other plants and simultaneously, using a supplementary fuel, produces electric power at high efficiency. FCE is currently evaluating the use of ECM to cost effectively separate CO2 from the flue gas of coal fired power plants under a U.S. Department of Energy contract. The overarching objective of the project is to verify that the ECM can achieve at least 90% CO2 capture from flue gas of a PC plant with no more than 35% increase in the cost of electricity. The specific objectives and related activities presently ongoing for the project include: 1) conduct bench scale tests of ECM and 2) evaluate the effects of impurities present in the coal plant flue gas by laboratory scale performance tests of the membrane.

carbon↗

High Power UV LED Industrial Curing Systems

UV curing is a green technology that is largely underutilized because UV radiation sources like Hg Lamps are unreliable and difficult to use. High Power UV LEDs are now efficient enough to replace Hg Lamps, and offer significantly improved performance relative to Hg Lamps. In this study, a modular, scalable high power UV LED curing system was designed and tested, performing well in industrial coating evaluations. In order to achieve mechanical form factors similar to commercial Hg Lamp systems, a new patent pending design was employed enabling high irradiance at long working distances. While high power UV LEDs are currently only available at longer UVA wavelengths, rapid progress on UVC LEDs and the development of new formulations designed specifically for use with UV LED sources will converge to drive more rapid adoption of UV curing technology. An assessment of the environmental impact of replacing Hg Lamp systems with UV LED systems was performed. Since UV curing is used in only a small portion of the industrial printing, painting and coating markets, the ease of use of UV LED systems should increase the use of UV curing technology. Even a small penetration of the significant number of industrial applications still using oven curing and drying will lead to significant reductions in energy consumption and reductions in the emission of green house gases and solvent emissions.

42 ENGINEERING↗

Test plan for the irradiation of nonmetallic materials.

A comprehensive test program to evaluate nonmetallic materials use in the Hanford tank farms is described in detail. This test program determines the effects of simultaneous multiple stressors at reasonable conditions on in-service configuration components by engineering performance testing.

Brush, Laurence H.↗

Test plan for the irradiation of nonmetallic materials.

A comprehensive test program to evaluate nonmetallic materials use in the Hanford Tank Farms is described in detail. This test program determines the effects of simultaneous multiple stressors at reasonable conditions on in-service configuration components by engineering performance testing.

Brush, Laurence H.↗

SRNL SHELF LIFE STUDIES - SCC STUDIES AT ROOM TEMPERTURE [stress corrosion cracking ]

Phase II, Series 2 corrosion testing performed by the Savannah River National Laboratory (SRNL) for the Department of Energy 3013 container has been completed. The corrosion tests are part of an integrated plan conducted jointly by Los Alamos National Laboratory and the Savannah River Site. SRNL was responsible for conducting corrosion studies in small-scale vessels to address the influence of salt composition, water loading, and type of oxide/salt contact on the relative humidity inside a 3013 container and on the resulting corrosion of Type 304L and 316L stainless steel (304L and 316L). This testing was conducted in two phases: Phase I evaluated a broad spectrum of salt compositions and initial water loadings on the salt mixtures exposed to 304L and 316L and the resulting corrosion; Phase II evaluated the corrosion of 304L at specific water loadings and a single salt composition. During Phase I testing at high initial moisture levels (0.35 to 1.24 wt%)a, the roomtemperature corrosion of 304L exposed to a series of plutonium oxide/chloride salt mixtures ranged from superficial staining to pitting and stress corrosion cracking (SCC). 304L teardrop coupons that exhibited SCC were directly exposed to a mixture composed of 98 wt % PuO2, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl2. Cracking was not observed in a 316L teardrop coupon. Pitting was also observed in this environment for both 304L and 316L with depths ranging from 20 to 100 μm. Neither pitting nor SCC was observed in mixtures with a greater chloride salt concentration (5 and 28 wt%). These results demonstrated that for a corrosive solution to form a balance existed between the water loading and the salt chloride concentration. This chloride solution results from the interaction of loaded water with the hydrating CaCl2 salt. In Phase II, Series 1 tests, the SCC results were shown to be reproducible with cracking occurring in as little as 85 days. The approximate 0.5 wt% moisture level was found to result in an initial relative humidity of ~55% within the small-scale vessels. Pits were found to be associated with cracks and appeared to act as initiators for the cracking. In a vapor-space only exposure, the weld oxide, which results from the TIG closure weld used to fabricate the teardrop coupon, was also shown to be more susceptible to pitting corrosion than a surface free from weld oxide. This result has important implications for the closure weld of the 3013 inner can since the weld oxide on the can internal surface cannot be removed. The results from the Phase II, Series 2 tests further demonstrated the significance of forming a solution with a critical chloride concentration for corrosion to proceed. 304L teardrop coupons were found to corrode only by pitting with a similar oxide/salt mixture as used in Series 1 testing but with a lower water loading of 0.2 wt%, which resulted in an initial relative humidity of 35-38%. These tests ran twice as long as those for Series 1 testing. The exposure condition was also found to impact the corrosion with salt-exposed surfaces showing lower corrosion resistance. Additional analyses of the Series 2 coupons are recommended especially for determining if cracks emanate from the bottom of pits. Data generated under the 2009 3013 corrosion test plan, as was presented here, increased the understanding of the corrosion process within a sealed 3013 container. Along with the corrosion data from destructive evaluations of 3013 containers, the inner can closure weld region (ICCWR) has been identified as the most vulnerable area of the inner can where corrosion may lead to corrosive species leaking to the interior surface of the outer container, thereby jeopardizing the integrity of the 3013 container. A new corrosion plan has been designed that will characterize the corrosion at the ICCWR of 3013 DEs as well as parameters affecting this corrosion.

3013 plutonium storage, stress corrosion cracking,↗

Fluctuations in the Dynamics of Glasses

This research program addressed the question of the presence of dynamical heterogeneities – strong spatial fluctuations in the dynamics – in glass forming liquids and jamming systems near dynamical arrest, with particular emphasis on aging systems, i.e. systems that are in the (non-equilibrium) glass regime. The main goals proposed for this research were: to perform numerical simulations of atomistic structural glass models to characterize dynamical heterogeneities in out of equilibrium (aging) glassy systems; to test the hypothesis that a certain symmetry (“time reparametrization symmetry”) is present in microscopic models of glassy systems and that this symmetry can explain the main features of dynamical heterogeneities; and to test to what extent these phenomena are universal across different glassy/jamming systems. It was found that: most of the important features of dynamical heterogeneities in the aging regime could be described in terms of simple scaling behaviors; that some of the most basic theoretical models of glassy systems indeed have time reparametrization symmetry; that all tests performed in numerical simulation data were consistent with the predictions from time reparametrization symmetry; and that to a large degree, the main features of dynamical heterogeneities were universal across different glassy systems. Most of the findings that came out of this research have been reported in detail in eight papers in high quality journals, two unpublished but publicly accessible manuscripts, and 27 invited and contributed talks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CALiPER Application Summary Report 14: LED Downlight Retrofit Units

This CALiPER report analyzes the independently tested performance of 11 anonymously purchased LED downlight retrofit units—referred to as the Series 14 products. All the units were tested in a 6-inch insulation contact (IC) rated downlight housing mounted in a 24-inch by 24-inch insulated enclosure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flue Gas Water Vapor Latent Heat Recovery for Pressurized Oxy-Combustion

This final report presents the results of a three-year technology development project carried out by a team of participants sponsored by the Department of Energy (DOE). This is addressing the FOA Area of Interest 2: Enabling Combustion Technology. Specifically, the technology targets for flue gas water vapor latent heat recovery from pressurized oxy-coal combustion power plants. A pilot scale Transport Membrane Condenser (TMC) system has been developed, fabricated, integrated, and performance-tested in a pressurized oxy-coal pilot-scale combustion system to prove its effectiveness. We have evaluated its performance and analyzed the results for application to commercial-scale power plants. We expect the same technology to be also applicable to pressurized chemical looping combustion (CLC) flue gas, which has similar conditions.

01 COAL, LIGNITE, AND PEAT↗

Idaho Falls Power Black Start Field Demonstration (Preliminary Outcomes Paper)

This April 2021 field demonstration builds upon a 2017 field demonstration in which it was determined IFP’s HPPs, on their own, can support islanded black start and operation up to 2.5 MW loading. Modeling and hardware-in-the-loop testing was used in the intervening period to design an energy storage solution, specifically using ultracapacitors, to reduce likelihood of generators tripping during the field demonstration. Overall, the 2021 field demonstration tested three different options for meeting IFP’s requirements: innovating the hydropower controls, synchronizing multiple HPPs on the system, and integrating an ultracapacitor energy storage system. This report documents the testing performed. Follow-on analysis will provide additional insights, for example, including a complete table of comparative results between the tests and scenarios. The analysis will also propose a refined design for an energy storage system to meet IFP’s grid islanded needs.

13 HYDRO ENERGY↗