Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROTOTYPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Lab-Scale Cable-Driven Parallel Robot Prototype for Automated Prefabricated Component Manipulation

This paper presents the design and evaluation of a lab-scale cable-driven parallel robot (CDPR) developed as a flexible platform for automated installation of prefabricated components onto exterior building envelopes. Traditional manual installation methods for prefabricated components, which depend on scaffolding, cranes, cherry pickers, and verbal coordination, are not only labor-intensive and error-prone but also face significant limitations in dense urban environments due to site access constraints. To address these challenges, we developed a lab-scale CDPR platform capable of autonomously transporting building envelope components from a designated pickup zone to their target installation location, minimizing the need for human intervention. This study describes the system’s mechanical design, actuation architecture, real-time feedback system, and control strategy of the CDPR, and evaluates its performance in a laboratory environment. The robot’s actuation system uses torque control for end-effector manipulation. The robot’s real-time pose feedback comes from a construction-grade total station and a wireless inertial measurement unit (IMU), which together support precise end-effector control. Experimental results demonstrate the successful integration of the hardware, sensing, state estimation, and control subsystems. Preliminary tests showed that our lab-scale prototype can position the end effector with an error of less than 3 mm, which is a level of precision not previously achieved by existing CDPRs in construction applications. The key findings are twofold: (1) torque-only control is necessary but not sufficient for minimizing final pose error, and (2) incorporating real-time pose feedback can achieve the desired placement accuracy.

Liu, Yifang [Oak Ridge National Laboratory (ORNL),↗

Underground Prototype Water Cherenkov Muon Detector with the Tibet Air Shower Array

We are planning to build a 10,000 m{sup 2} water-Cherenkov-type muon detector (MD) array under the Tibet air shower (AS) array. The Tibet AS+MD array will have the sensitivity to detect gamma rays in the 100 TeV region by an order of the magnitude better than any other previous existing detectors in the world. In the late fall of 2007, a prototype water Cherenkov muon detector of approximately 100 m{sup 2} was constructed under the existing Tibet AS array. The preliminary data analysis is in good agreement with our MC simulation. We are now ready for further expanding the underground water Cherenkov muon detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision hyperfine structure spectroscopy of Be isotopes at SLOWRI prototype and prospects of SLOWRI at RIKEN

Precision atomic spectroscopy experiments for Be isotopes have been carried out at the prototype universal slow RI-beam (SLOWRI) setup at RIKEN. Radioactive Be ions produced at 1 GeV were decelerated and thermlized in an RF-carpet ion guide. The thermalized ions were transferred to an ion trap where laser cooling was used to reduce the ion energy to the order of 1 {mu}eV. Laser microwave double resonance spectroscopy was performed for the hyperfine structure measurements of trapped and laser cooled {sup 7}Be{sup +} and {sup 11}Be{sup +} ions. Measurements of the S{sub 1/2}{yields}P{sub 1/2},P{sub 3/2} transition frequencies of {sup 7,9,10,11}Be{sup +} ions are also in progress. These results are briefly discussed. Future prospects for expanding the capability of SLOWRI is also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

The entrance system laboratory prototype for an advanced mass and ionic charge composition experiment

Electrostatic analyzers (ESA) have been used extensively for the characterization of plasmas in a variety of space environments. They vary in shape, geometry, and size and are adapted to the specific particle population to be measured and the configuration of the spacecraft. Their main function is to select the energy per charge of the particles within a passband. An energy-per-charge range larger than that of the passband can be sampled by varying the voltage difference between the ESA electrodes. The voltage sweep takes time and reduces the duty cycle for a particular energy-per-charge passband. Our design approach for an advanced mass and ionic charge composition experiment (AMICCE) has a novel electrostatic analyzer that essentially serves as a spectrograph and selects ions simultaneously over a broad range of energy-per-charge (E/q). Only three voltage settings are required to cover the entire range from {approx}10 to 270 keV/q, thus dramatically increasing the product of the geometric factor times the duty cycle when compared with other instruments. In this paper, we describe the AMICCE concept with particular emphasis on the prototype of the entrance system (ESA and collimator), which we designed, developed, and tested. We also present comparisons of the laboratory results with electrostatic simulations.

42 ENGINEERING↗

A laser-Compton scattering prototype experiment at 100 MeV linac of Shanghai Institute of Applied Physics

As a prototype of the Shanghai Laser Electron Gamma Source in the Shanghai Synchrotron Radiation Facility, an x-ray source based on laser-Compton scattering (LCS) has been installed at the terminal of the 100 MeV linac of the Shanghai Institute of Applied Physics. LCS x-rays are generated by interactions between Q-switched Nd:yttrium aluminum garnet laser pulses [with wavelength of 1064 nm and pulse width of 21 ns (full width at half maximum)] and electron bunches [with energy of 108 MeV and pulse width of 0.95 ns (rms)] at an angle of 42 deg. between laser and electron beam. In order to measure the energy spectrum of LCS x-rays, a Si(Li) detector along the electron beam line axis is positioned at 9.8 m away from a LCS chamber. After background subtraction, the LCS x-ray spectrum with the peak energy of 29.1{+-}4.4|{sub stat}{+-}2.1|{sub syst} keV and the peak width (rms) of 7.8{+-}2.8|{sub stat}{+-}0.4|{sub syst} keV is observed. Normally the 100 MeV linac operates with the electron macropulse charge of 1.0 nC/pulse, and the electron and laser collision repetition rate of 20 Hz. Therefore, the total LCS x-ray flux of (5.2{+-}2.0)x10{sup 2} Hz can be achieved.

43 PARTICLE ACCELERATORS↗

Commissioning Of The MINER{nu}A Tracking Prototype

MINER{nu}A is a neutrino scattering experiment that uses the NuMI beamline at Fermilab. A Tracking Prototype was assembled, commissioned and tested at Fermilab before moving it into the NuMI beamline. A description of some of the main commissioning activities is presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum Studies of a Prototype Composite Coil Dewar for HTSC Transformers

Oak Ridge National Laboratory (ORNL) is collaborating with Waukesha Electric Systems (WES) to develop a high-temperature superconducting (HTSC) utility power transformer with primary and secondary coils cooled by liquid nitrogen. Since the vacuum-insulated cryogenic coil dewar surrounds the magnetic core limb and cannot form a shorted turn, non-conductive materials are required. Two test vessels and a small prototype dewar have been fabricated by Scorpius Space Launch Company with epoxy/fiberglass composites, using their proprietary PRESSURMAXX vessel technology. The effects of pumping time, bakeout temperature, and cryogenic vessel temperature on vacuum outgassing rates have been investigated. Outgassing rates of the individual materials used in vessel construction have also been measured. The results will be scaled up to determine the required pumping capacity for a full-size 25-MVA commercial transformer dewar.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototype high resolution multienergy soft x-ray array for NSTX

A novel diagnostic design seeks to enhance the capability of multienergy soft x-ray (SXR) detection by using an image intensifier to amplify the signals from a larger set of filtered x-ray profiles. The increased number of profiles and simplified detection system provides a compact diagnostic device for measuring T{sub e} in addition to contributions from density and impurities. A single-energy prototype system has been implemented on NSTX, comprised of a filtered x-ray pinhole camera, which converts the x-rays to visible light using a CsI:Tl phosphor. SXR profiles have been measured in high performance plasmas at frame rates of up to 10 kHz, and comparisons to the toroidally displaced tangential multi-energy SXR have been made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of multifilter based twin-prototypes for core electron temperature measurements in the TJ-II stellarator

The design and preliminary results from a prototype of a multifilter based electron temperature diagnostic for the TJ-II stellarator are presented. The diagnostic consists of four photodiodes with filters of different thicknesses to determine the electron temperature in a wide variety of plasma compositions, thanks to the set of six different signal-pairs ratios available. The impurity transport code IONEQ, the TJ-II soft x-ray tomography, and the VUV survey diagnostics give the necessary information to assess the proposed diagnostic reliability. In parallel, a vacuum-compatible multichannel electronic board has been designed for a future linear array to determine electron temperature profiles in high-density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of rapid, continuous calibration techniques and implementation as a prototype system for civil engineering materials evaluation

Until recently, civil engineering material calibration data could only be obtained from material sample cores or via time consuming, stationary calibration measurements in a limited number of locations. Calibration data are used to determine material propagation velocities of electromagnetic waves in test materials for use in layer thickness measurements and subsurface imaging. Limitations these calibration methods impose have been a significant impediment to broader use of nondestructive evaluation methods such as ground-penetrating radar (GPR). In 2006, a new rapid, continuous calibration approach was designed using simulation software to address these measurement limitations during a Federal Highway Administration (FHWA) research and development effort. This continuous calibration method combines a digitally-synthesized step-frequency (SF)-GPR array and a data collection protocol sequence for the common midpoint (CMP) method. Modeling and laboratory test results for various data collection protocols and materials are presented in this paper. The continuous-CMP concept was finally implemented for FHWA in a prototype demonstration system called the Advanced Pavement Evaluation (APE) system in 2009. Data from the continuous-CMP protocol is processed using a semblance/coherency analysis to determine material propagation velocities. Continuously calibrated pavement thicknesses measured with the APE system in 2009 are presented. This method is efficient, accurate, and cost-effective.

42 ENGINEERING↗

ITER ICH Transmission Line and Matching System Prototype Development

Design and testing of prototype components for the ITER Ion Cyclotron Heating (ICH) transmission line and matching system is underway. Each ICH transmission line is designed to handle up to 6 MW/line in the 40–55 MHz frequency range. A total of 8 lines split to 16 antenna inputs on two ICH antennas. The ICH system is made up of 14 types of unique coaxial transmission line and matching components. The matching system is designed to provide passive ELM tolerance through the use of hybrid couplers and loads, which can absorb the transient reflected power. In addition the system is designed to compensate for coupling between antenna inputs caused by the mutual inductances of the current straps. It is further designed to balance as much as reasonable, the power requirements from the sources and the peak voltages on the antenna array elements.

42 ENGINEERING↗

Development of the prototype pneumatic transfer system for ITER neutron activation system

The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct drive implosion experiments on SGIII prototype laser facility: Assessing energy coupling efficiency and implosion symmetry

Direct drive implosion experiments were conducted on SGIII prototype laser facility. From the time resolved x-ray images, the bright ring and the central bright spot are observed. The radial velocity of the convergent bright ring indicates the shell velocity, and the times when the central bright spot is first seen and becomes most intensive indicate the times of shock convergence and later stagnation, respectively. Radiation hydrodynamic simulations were carried out by changing laser energy deposition factors. When the simulated results are brought close to the measured ones, it is found that the energy coupling efficiency is around 70%. The implosion symmetry is indicated by the core x-ray emission pattern which is pancake when viewing from the equator, and splits into several bright spots when viewing close to the pole. A simple model is developed to understand this asymmetry. It is speculated that the observed implosion asymmetry can be attributed to the laser arrangement which is originally designed for indirect drive experiments. Further improvements of energy coupling efficiency and implosion symmetry in future experiments can be achieved by optimizing target design and laser arrangement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the molecule-substrate interaction of prototypic tetrapyrrole compounds: Adsorption and self-metalation of porphine on Cu(111)

We report on the adsorption and self-metalation of a prototypic tetrapyrrole compound, the free-base porphine (2H-P), on the Cu(111) surface. Our multitechnique study combines scanning tunneling microscopy (STM) results with near-edge X-ray absorption fine-structure (NEXAFS) and X-ray photoelectron spectroscopy (XPS) data whose interpretation is supported by density functional theory calculations. In the first layer in contact with the copper substrate the molecules adsorb coplanar with the surface as shown by angle-resolved NEXAFS measurements. The quenching of the first resonance in the magic angle spectra of both carbon and nitrogen regions indicates a substantial electron transfer from the substrate to the LUMO of the molecule. The stepwise annealing of a bilayer of 2H-P molecules sequentially transforms the XP and NEXAFS signatures of the nitrogen regions into those indicative of the coordinated nitrogen species of the metalated copper porphine (Cu-P), i.e., we observe a temperature-induced self-metalation of the system. Pre- and post-metalation species are clearly discriminable by STM, corroborating the spectroscopic results. Similar to the free-base porphine, the Cu-P adsorbs flat in the first layer without distortion of the macrocycle. Additionally, the electron transfer from the copper surface to the molecule is preserved upon metalation. This behavior contrasts the self-metalation of tetraphenylporphyrin (2H-TPP) on Cu(111), where both the molecular conformation and the interaction with the substrate are strongly affected by the metalation process.

36 MATERIALS SCIENCE↗

The prototype of a detector for monitoring the cosmic radiation neutron flux on ground

This work presents a comparison between the results of experimental tests and Monte Carlo simulations of the efficiency of a detector prototype for on-ground monitoring the cosmic radiation neutron flux. The experimental tests were made using one conventional {sup 241}Am-Be neutron source in several incidence angles and the results were compared to that ones obtained with a Monte Carlo simulation made with MCNPX Code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy flux thermo-mechanical test of 1D-carbon-carbon fibre composite prototypes for the SPIDER diagnostic calorimeter

Operation of the thermonuclear fusion experiment ITER requires additional heating via injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in Padova, the production of negative ions will be studied and optimised. STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to characterise the SPIDER beam during short pulse operation (several seconds) to verify if the beam meets the ITER requirements about the maximum allowed beam non-uniformity (below ±10%). The major components of STRIKE are 16 1D-CFC (Carbon-Carbon Fibre Composite) tiles, observed at the rear side by a thermal camera. This contribution gives an overview of some tests under high energy particle flux, aimed at verifying the thermo-mechanical behaviour of several CFC prototype tiles. The tests were performed in the GLADIS facility at IPP (Max-Plank-Institut für Plasmaphysik), Garching. Dedicated linear and nonlinear simulations were carried out to interpret the experiments and a comparison of the experimental data with the simulation results is presented. The results of some morphological and structural studies on the material after exposure to the GLADIS beam are also given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary results from direct-drive cryogenic target implosion experiments on SGIII prototype laser facility

Since ignition target design with layered deuterium and triterium ice had been proposed several decades ago, much effort was devoted to fabricate and implode cryogenic targets. Until recently, direct-drive cryogenic target implosion experiment was carried out on SGIII prototype laser facility. The target consisted of a plastic capsule supported by fill tube. Cryogenic helium gas was used to cool the capsule to a few degrees below the deuterium triple point. The resulting deuterium ice layer was characterized by optical shadowgraph and smoothed by applied temperature gradient. Eight laser beams with total energy of 7 kJ were used to directly drive the implosion. On the path of laser light to the capsule, there were 500 nm sealing film and helium gas of mm length. X-ray pinhole images were analyzed to confirm that the sealing film, and helium gas had little effect on aiming accuracy but caused some loss of laser energy especially when condensation on the sealing film was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum mechanical study of solvent effects in a prototype S{sub N}2 reaction in solution: Cl{sup −} attack on CH{sub 3}Cl

The nucleophilic attack of a chloride ion on methyl chloride is an important prototype S{sub N}2 reaction in organic chemistry that is known to be sensitive to the effects of the surrounding solvent. Herein, we develop a highly accurate Specific Reaction Parameter (SRP) model based on the Austin Model 1 Hamiltonian for chlorine to study the effects of solvation into an aqueous environment on the reaction mechanism. To accomplish this task, we apply high-level quantum mechanical calculations to study the reaction in the gas phase and combined quantum mechanical/molecular mechanical simulations with TIP3P and TIP4P-ew water models and the resulting free energy profiles are compared with those determined from simulations using other fast semi-empirical quantum models. Both gas phase and solution results with the SRP model agree very well with experiment and provide insight into the specific role of solvent on the reaction coordinate. Overall, the newly parameterized SRP Hamiltonian is able to reproduce both the gas phase and solution phase barriers, suggesting it is an accurate and robust model for simulations in the aqueous phase at greatly reduced computational cost relative to comparably accurate ab initio and density functional models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗