Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Evaluation of ion collection area in Faraday probes

A Faraday probe with three concentric rings was designed and fabricated to assess the effect of gap width and collector diameter in a systematic study of the diagnostic ion collection area. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collectors. Two versions of the outer collector were fabricated to create gaps of 0.5 and 1.5 mm between the rings. Distribution of current density in the plume of a low-power Hall thruster ion source was measured in azimuthal sweeps at constant radius from 8 to 20 thruster diameters downstream of the exit plane with variation in facility background pressure. A new analytical technique is proposed to account for ions collected in the gap between the Faraday probe collector and guard ring. This method is shown to exhibit excellent agreement between all nested Faraday probe configurations, and to reduce the magnitude of integrated ion beam current to levels consistent with Hall thruster performance analyses. The technique is further studied by varying the guard ring bias potential with a fixed collector bias potential, thereby controlling ion collection in the gap. Results are in agreement with predictions based on the proposed analytical technique. The method is applied to a past study comparing the measured ion current density profiles of two Faraday probe designs. These findings provide new insight into the nature of ion collection in Faraday probe diagnostics, and lead to improved accuracy with a significant reduction in measurement uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Methodology for the Characterisation of Air-coupled Ultrasound Probes

This study is aimed at developing a technique for the characterisation of air-coupled ultrasound probes, starting from the analysis of the mechanical behaviour of the probe membrane. The vibratory behaviour of the emission membrane is studied using laser-Doppler vibrometry techniques with high frequency demodulation system (20 MHz). The determination of the vibration provides information which are useful for the assessment of the performance of the probe, in particular concerning the Quality factor and the portion of the membrane which really contributes to the emission. During the second step the results of the vibration measurements are used to calculate, by means of numerical boundary element method, the ultrasound beam emitted in terms of intensity in space. The obtained field is compared with the direct measurements carried out by scanning with the receiver probe and a pinhole plate. This comparison allows the potential and the problems of the two different characterisation techniques to be determined, even if the pinhole technique (which is currently considered the state of the art) cannot be used as an absolute reference. This study appears to be useful for paving the way for a new methodology for the calibration of air-coupled ultrasound probes, which potentially could be used not only to improve the probe manufacturing process, but also to control conformity to specifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast reciprocating probe system on the EAST superconducting tokamak

A new fast reciprocating probe system (FRPS) has been built and installed on the outer midplane of the EAST tokamak to investigate the profiles of the boundary plasma parameters such as electron density and temperature. The system consists of a two-stage motion drive mechanism: slow motion and fast motion. The fast motion is powered by a servo motor, which drives the probe horizontally up to 50 cm to scan the edge region of the EAST tokamak. The maximum velocity achieved is 2 m/s. High velocity and flexible control of the fast motion are the remarkable features of this FRPS. A specially designed connector installed at the front end of the probe shaft makes it easy to install or replace the probe head on FRPS. During the latest experimental campaign in the spring of 2010, a probe head with seven tips, including two tips for a Mach probe, has been used. An example is given for simultaneous profile measurements of the plasma temperature, plasma density, and the plasma flow velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the electron density gradients of dense plasmas by deflectometry using short-wavelength probe

A new and simple experimental technique for the measurement of electron density gradients in dense laser-produced plasmas using an electromagnetic wave probe is presented. The main advantage of this method is the low requirements on coherence of the probing beam. The method is based on measuring the deformation of the Talbot pattern of a two-dimensional grating that stems from the distortion of the probe beam wave-front caused by the gradients of the index of refraction. The compromise between spatial resolution and sensitivity for the given wavelength of the probe beam is set by the experimental design. The proposed technique was experimentally verified on plasmas that were created by either a point focus or a line focus of a laser interacting with various solid targets. In the experiments reported here, all plasmas were probed by a Ne-like Zn x-ray laser beam at 21.2 nm, but the technique is applicable for any wavelength of the probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved analysis techniques for cylindrical and spherical double probes

A versatile double Langmuir probe technique has been developed by incorporating analytical fits to Laframboise's numerical results for ion current collection by biased electrodes of various sizes relative to the local electron Debye length. Application of these fits to the double probe circuit has produced a set of coupled equations that express the potential of each electrode relative to the plasma potential as well as the resulting probe current as a function of applied probe voltage. These equations can be readily solved via standard numerical techniques in order to determine electron temperature and plasma density from probe current and voltage measurements. Because this method self-consistently accounts for the effects of sheath expansion, it can be readily applied to plasmas with a wide range of densities and low ion temperature (T{sub i}/T{sub e} Much-Less-Than 1) without requiring probe dimensions to be asymptotically large or small with respect to the electron Debye length. The presented approach has been successfully applied to experimental measurements obtained in the plume of a low-power Hall thruster, which produced a quasineutral, flowing xenon plasma during operation at 200 W on xenon. The measured plasma densities and electron temperatures were in the range of 1 Multiplication-Sign 10{sup 12}-1 Multiplication-Sign 10{sup 17} m{sup -3} and 0.5-5.0 eV, respectively. The estimated measurement uncertainty is +6%/-34% in density and +/-30% in electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of effective sheath width around cutoff probe in low-pressure plasmas

Previous studies indicated that the measurement results of microwave probes can be improved by applying the adequate sheath width to their measurement models, and consequently the sheath width around the microwave probe tips has become very important information for microwave probe diagnostics. In this paper, we propose a method for measuring the argon plasma sheath width around the cutoff probe tips by applying the circuit model to the cutoff probe phase spectrum. The measured sheath width of the cutoff probe was found to be in good agreement with the floated sheath width calculated from the Child-Langmuir sheath law. The physical reasons for a discrepancy between the two measurements are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the use of the double floating probe method to infer the difference between the electron and the heavy particles temperatures in an atmospheric pressure, vortex-stabilized nitrogen plasma jet

Sweeping double probe measurements in an atmospheric pressure direct current vortex-stabilized plasma jet are reported (plasma conditions: 100 A discharge current, N{sub 2} gas flow rate of 25 Nl/min, thoriated tungsten rod-type cathode, copper anode with 5 mm inner diameter). The interpretation of the double probe characteristic was based on a generalization of the standard double floating probe formulae for non-uniform plasmas coupled to a non-equilibrium plasma composition model. Perturbations caused by the current to the probe together with collisional and thermal processes inside the probe perturbed region were taken into account. Radial values of the average electron and heavy particle temperatures as well as the electron density were obtained. The calculation of the temperature values did not require any specific assumption about a temperature relationship between different particle species. An electron temperature of 10 900 ± 900 K, a heavy particle temperature of 9300 ± 900 K, and an electron density of about 3.5 × 10{sup 22} m{sup −3} were found at the jet centre at 3.5 mm downstream from the torch exit. Large deviations from kinetic equilibrium were found toward the outer border of the plasma jet. These results showed good agreement with those previously reported by the authors by using a single probe technique. The calculations have shown that this method is particularly useful for studying spraying-type plasma torches operated at power levels of about 15 kW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Movable multi-probes for plasma boundary measurement in sino-united spherical tokamak

A novel movable multi-probes is developed to get local magnetic and electrostatic profiles on Sino-UNIted Spherical Tokamak (SUNIST). This multi-probes combines a four-tips Langmuir probe, a magnetic coil, and a retarding field energy analyzer (RFEA). It can be used to simultaneously measure the poloidal magnetic field B{sub p}, electric field E{sub r}, electron temperature T{sub e}, electron density n{sub e}, and ion temperature T{sub i}. Its small overall size (20 × 20 × 38 mm{sup 3}) enables the movable multi-probes to measure the magnetic and electrostatic profiles in high spatial resolution, with negligible impact to plasma in SUNIST. This paper presents the design of the movable multi-probes, in particular, details of RFEA for reliable ion energy measurements. Preliminary experimental results of the movable multi-probes are given as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probe diagnostics of electron distributions in plasma with spatial and angular resolution

This paper discusses the spatial resolution that is required to study inhomogeneous, low-temperature plasmas and is based on a review of low-temperature plasma electron kinetics and methods for probe measurements of electron energy distribution functions (EEDFs). It is stated that EEDFs can be extracted from probe measurements by applying an appropriate probe theory. The Druyvesteyn formula is most commonly used for this extraction and has been used in numerous publications, but more general theory can be used for a wider range of gas pressures. It is demonstrated that the Druyvesteyn formula can be obtained from the general theory as a limiting case. This paper justifies the application of wall probes in plasma studies of an energetic part of EEDFs. This justification is made for an idealized probe. We briefly review the methods for studying anisotropic plasmas and their usefulness in plasma research. It is demonstrated that to determine anisotropic electron energy distribution functions, a planar, one-sided probe is most convenient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of double-probe characteristics in low-frequency gas discharges and its improvement

The double-probe has been used successfully in radio-frequency discharges. However, in low-frequency discharges, the double-probe I-V curve is so much seriously distorted by the strong plasma potential fluctuations that the I-V curve may lead to a large estimate error of plasma parameters. To suppress the distortion, we investigate the double-probe characteristics in low-frequency gas discharge based on an equivalent circuit model, taking both the plasma sheath and probe circuit into account. We discovered that there are two primary interferences to the I-V curve distortion: the voltage fluctuation between two probe tips caused by the filter difference voltage and the current peak at the negative edge of the plasma potential. Consequently, we propose a modified passive filter to reduce the two types of interference simultaneously. Experiments are conducted in a glow-discharge plasma (f = 30 kHz) to test the performance of the improved double probe. The results show that the electron density error is reduced from more than 100% to less than 10%. The proposed improved method is also suitable in cases where intensive potential fluctuations exist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative measurements of plasma potential with ball-pen and Langmuir probe in low-temperature magnetized plasma

The ball-pen probe (BPP) is used for direct plasma potential measurements in magnetized plasma. The probe can adjust the ratio of the electron and ion saturation currents I{sub sat}{sup −}/I{sub sat}{sup +} to be close to one and therefore its I-V characteristic becomes nearly symmetric. If this is achieved, the floating potential of the BPP is close to the plasma potential. Because of its rather simple construction, it offers an attractive probe for measurements in magnetized plasma. Comparative measurements of plasma potential by BPPs of different dimensions as well as one Langmuir probe (LP) in an argon discharge plasma of a cylindrical magnetron were performed at various experimental conditions. An additional comparison by an emissive probe was also performed. All these types of probes provide similar values of plasma potential in a wide range of plasma parameters. Our results for three different BPP dimensions indicate that the BPP can be operated in a cylindrical magnetron DC argon discharge if the value of the ratio of the magnetic field and neutral gas pressure, B/p, is greater than approximately 10 mT/Pa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and analysis of electron-neutral collision frequency in the calibrated cutoff probe

As collisions between electrons and neutral particles constitute one of the most representative physical phenomena in weakly ionized plasma, the electron-neutral (e-n) collision frequency is a very important plasma parameter as regards understanding the physics of this material. In this paper, we measured the e-n collision frequency in the plasma using a calibrated cutoff-probe. A highly accurate reactance spectrum of the plasma/cutoff-probe system, which is expected based on previous cutoff-probe circuit simulations [Kim et al., Appl. Phys. Lett. 99, 131502 (2011)], is obtained using the calibrated cutoff-probe method, and the e-n collision frequency is calculated based on the cutoff-probe circuit model together with the high-frequency conductance model. The measured e-n collision frequency (by the calibrated cutoff-probe method) is compared and analyzed with that obtained using a Langmuir probe, with the latter being calculated from the measured electron-energy distribution functions, in wide range of gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of electron density using reactance cutoff probe

This paper proposes a new measurement method of electron density using the reactance spectrum of the plasma in the cutoff probe system instead of the transmission spectrum. The highly accurate reactance spectrum of the plasma-cutoff probe system, as expected from previous circuit simulations [Kim et al., Appl. Phys. Lett. 99, 131502 (2011)], was measured using the full two-port error correction and automatic port extension methods of the network analyzer. The electron density can be obtained from the analysis of the measured reactance spectrum, based on circuit modeling. According to the circuit simulation results, the reactance cutoff probe can measure the electron density more precisely than the previous cutoff probe at low densities or at higher pressure. The obtained results for the electron density are presented and discussed for a wide range of experimental conditions, and this method is compared with previous methods (a cutoff probe using the transmission spectrum and a single Langmuir probe).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical and experimental study of the dynamic response of absorber-based, micro-scale, oscillatory probes for contact sensing applications

This paper presents two models for predicting the frequency response of micro-scale oscillatory probes. These probes are manufactured by attaching a thin fiber to the free end of one tine of a quartz tuning fork oscillator. In these studies, the attached fibers were either 75 μm diameter tungsten or 7 μm diameter carbon with lengths ranging from around 1 to 15 mm. The oscillators used in these studies were commercial 32.7 kHz quartz tuning forks. The first theoretical model considers lateral vibration of two beams serially connected and provides a characteristic equation from which the roots (eigenvalues) are extracted to determine the natural frequencies of the probe. A second, lumped model approximation is used to derive an approximate frequency response function for prediction of tine displacements as a function of a modal force excitation corresponding to the first mode of the tine in the absence of a fiber. These models are used to evaluate the effect of changes in both length and diameter of the attached fibers. Theoretical values of the natural frequencies of different modes show an asymptotic relationship with the length and a linear relationship with the diameter of the attached fiber. Similar results are observed from experiment, one with a tungsten probe having an initial fiber length of 14.11 mm incrementally etched down to 0.83 mm, and another tungsten probe of length 8.16 mm incrementally etched in diameter, in both cases using chronocoulometry to determine incremental volumetric material removal. The lumped model is used to provide a frequency response again reveals poles and zeros that are consistent with experimental measurements. Finite element analysis shows mode shapes similar to experimental microscope observations of the resonating carbon probes. This model provides a means of interpreting measured responses in terms of the relative motion of the tine and attached fibers. Of particular relevance is that, when a “zero” is observed in the response of the tine, one mode of the fiber is matched to the tine frequency and is acting as an absorber. This represents an optimal condition for contact sensing and for transferring energy to the fiber for fluid mixing, touch sensing, and surface modification applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bohm-criterion approximation versus optimal matched solution for a cylindrical probe in radial-motion theory

The theory of positive-ion collection by a probe immersed in a low-pressure plasma was reviewed and extended by Allen et al. [Proc. Phys. Soc. 70, 297 (1957)]. The numerical computations for cylindrical and spherical probes in a sheath region were presented by F. F. Chen [J. Nucl. Energy C 7, 41 (1965)]. Here, in this paper, the sheath and presheath solutions for a cylindrical probe are matched through a numerical matching procedure to yield “matched” potential profile or “M solution.” The solution based on the Bohm criterion approach “B solution” is discussed for this particular problem. The comparison of cylindrical probe characteristics obtained from the correct potential profile (M solution) and the approximated Bohm-criterion approach are different. This raises questions about the correctness of cylindrical probe theories relying only on the Bohm-criterion approach. Also the comparison between theoretical and experimental ion current characteristics shows that in an argon plasma the ions motion towards the probe is almost radial.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial solitary like weak probe wave in the three-level Λ-type atoms

We study the interaction of the medium composed of three-level atoms in A configuration interacting with two laser fields: weak probe field and strong control field. The probe field enters the medium under a certain angle, and it is initially in the form of the spatial soliton, while the control field is periodically modulated. The system of optical Bloch equations is analytically solved in the stationary regime by the perturbation method in order to obtain linear and third-order nonlinear susceptibility of the medium with respect to the probe field. After a straightforward algebraic procedure, using the approximation of the slow-varying field envelope, the nonlinear Schrödinger equation for the probe field is obtained. It is numerically solved by applying the spectral Fourier split-step method. It is found that, for properly chosen values of the probe and control field detunings and control Rabi frequency, the probe field behaves as a solitary wave whose direction does not depend on the incident angle. Moreover, the regime consisting of Bloch-like oscillations can be identified. The simulation is performed by choosing the corresponding levels of Mg atoms. © 2019 Author(s).

60 APPLIED LIFE SCIENCES↗

Ultrafast disruptive probing: Simultaneously keeping track of tens of reaction pathways

Ultrafast science depends on different implementations of the well-known pump–probe method. Here, we provide a formal description of ultrafast disruptive probing, a method in which the probe pulse disrupts a transient species that may be a metastable ion or a transient state of matter. Disruptive probing has the advantage of allowing for simultaneous tracking of the yield of tens of different processes. Our presentation includes a numerical model and experimental data on multiple products resulting from the strong-field ionization of two different molecules, partially deuterated methanol and norbornene. The correlated enhancement and depletion signals between all the different fragmentation channels offer comprehensive information on photochemical reaction pathways. In combination with ion imaging and/or coincidence momentum imaging or as complementary to atom-specific probing or ultrafast diffraction methods, disruptive probing is a particularly powerful tool for the study of strong-field laser–matter interactions.

47 OTHER INSTRUMENTATION↗