Improving the Deformation of Welded Pipe for Pipelines
The probability of cracks and fractures in pipe expansion is studied. A means of decreasing defect frequency in the deformation of pipe for major pipelines is proposed.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The probability of cracks and fractures in pipe expansion is studied. A means of decreasing defect frequency in the deformation of pipe for major pipelines is proposed.
The writer discusses the phenomena of expansion and compression which alternately take place in the cylinders of four-stroke engines during the induction process at a high mean piston speed due to the inertia and elasticity of the mixture in the intake pipe. The present paper is intended to demonstrate theoretically the existence of a most favorable pipe length for charging.
The Heat-pipe Power System (HPS) is a near-term, low-cost space power system designed at Los Alamos that can provide up to 1,000 kWt for many space nuclear applications. The design of the reactor is simple, modular, and adaptable. The basic design allows for the use of a variety of power conversion systems and reactor materials (including the fuel, clad, and heat pipes). This paper describes a project that was undertaken to develop a database supporting many engineering aspects of the HPS design. The specific tasks discussed in this paper are: the development of an HPS materials database, the creation of finite element models that will allow a wide variety of investigations, and the verification of past calculations.
Design concepts for small Fission Power Systems (FPS) have shown that heat pipe cooled reactors provide a passive, redundant, and lower mass option to transfer heat from the fuel to the power conversion system, as opposed to pumped loop designs typically associated with larger FPS. Although many systems have been conceptually designed and a few making it to electrically heated testing, none have been coupled to a real nuclear reactor. A demonstration test named DUFF Demonstration Using Flattop Fission, was planned by the Los Alamos National Lab (LANL) to use an existing criticality experiment named Flattop to provide the nuclear heat source. A team from the NASA Glenn Research Center designed, built, and tested a heat pipe and power conversion system to couple to Flattop with the end goal of making electrical power. This paper will focus on the design and testing performed in preparation for the DUFF test.
The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.
This is the presentation file for the short course Introduction to Loop Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. This course will discuss operating principles and performance characteristics of a loop heat pipe. Topics include: 1) pressure profiles in the loop; 2) loop operating temperature; 3) operating temperature control; 4) loop startup; 4) loop shutdown; 5) loop transient behaviors; 6) sizing of loop components and determination of fluid inventory; 7) analytical modeling; 8) examples of flight applications; and 9) recent LHP developments.
The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.
Electrowetting heat pipes (EHPs) are a newly conceptualized class of heat pipes, wherein the adiabatic wick section is replaced by electrowetting-based pumping of the condensate (as droplets) to the evaporator. Specific advantages include the ability to transport high heat loads over long distances, low thermal resistance and power consumption, and the absence of moving mechanical parts. In this work, we describe characterization of key microfluidic operations (droplet motion and splitting) underlying the EHP on the International Space Station (ISS). The testing was performed under the Advanced Passive Thermal eXperiment (APTx) project, a project to test a suite of passive thermal control devices funded by the ISS Technology Demonstration Office at NASA JSC (Johnson Space Center). A rapid manufacturing method was used to fabricate the electrowetting device on a printed circuit board. Key device-related considerations were to ensure reliability and package the experimental hardware within a confined space. Onboard the ISS, experiments were conducted to study electrowetting-based droplet motion and droplet splitting, by imaging droplet manipulation operations via pre-programmed electrical actuation sequences. An applied electric field of 36 Volts per micron resulted in droplet speeds approaching 10 millimeters per second. Droplet splitting dynamics were observed and the time required to split droplets was quantified. Droplet motion data was analyzed to estimate the contact line friction coefficient. Overall, this demonstration is the first-ever electrowetting experiment in space. The obtained results are useful for future design of the EHP and other electrowetting-based systems for microgravity applications.
This paper investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.
This investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.
Current models of the Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC) being developed for long duration space exploration utilize cooling chambers and heat plates to adsorb and desorb contaminants -13 . To reduce resources required and lower the equivalent system mass (ESM), the study focuses on determining the applications of titanium heat pipe systems to operate both phases, allowing for future research into the development of a heat pipe chamber to hold the zeolite formulations.
Spacecraft nuclear electric propulsion, as well as other emerging technologies, can benefit from heat pipes with optimal performance in the intermediate temperature, 450–700 K, regime. In this work, a 1D model was developed to investigate the performance of halide working fluids coupled with 3D printed-ceramic shells to operate at 500–600 K and interface with a nuclear electric propulsion system. An initial conceptual design and performance limits of a 3D printed-AlN heat pipe radiator with AlBr 3 as the working fluid is presented. An areal density of 5.2 kg/m 2 and mass per unit heat performance of 1.00kg/kW is estimated.
NASA’s space missions demand better and more efficient carbon dioxide removal systems. wo challenges present themselves in improving the state of the art pellet adsorption beds: power minimization and uniform heating for carbon dioxide desorption. Titanium heat pipes and vapor chambers were found to be excellent candidates in solving these problems because of their passive heating nature, tolerance to high temperatures, and capability of direct implementation into these adsorbent beds.This research work compares these different titanium heat pipes (HPs) and vapor chambers (VPs).
Advanced light water reactor systems are designed to use passive emergency core cooling systems with horizontal pipes that provide highly subcooled water from water storage tanks or passive heat exchangers to the reactor vessel core under accident conditions. Because passive systems are driven by density gradients, the horizontal pipes often do not flow full and thus have a free surface that is exposed to saturated steam and stratified flow is present.
The specification of damping for nuclear piping systems subject to seismic-induced motions has been the subject of many studies and much controversy. Damping estimation based on test data can be influenced by numerous factors, consequently leading to considerable scatter in damping estimates in the literature. At present, nuclear industry recommendations and nuclear regulatory guidance are not consistent on the treatment of damping for analysis of nuclear piping systems. Therefore, there is still a need to develop a more complete and consistent technical basis for specification of appropriate damping values for use in design and analysis. This paper summarizes the results of recent damping studies conducted at Brookhaven National Laboratory.
Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the effectiveness and reliability of advanced nondestructive examination (NDE) methods for the inspection of light water reactor (LWR) components. A primary objective of this work is to evaluate various NDE methods to assess their ability to detect, localize, and size cracks in coarse-grained steel components. This particular study focused on the evaluation of custom-designed, low-frequency (500 kHz) phased-array (PA) probes for examining welds in thick-section cast austenitic stainless steel (CASS) piping. In addition, research was conducted to observe ultrasonic sound field propagation effects from known coarse-grained microstructures found in parent CASS material. The study was conducted on a variety of thick-wall, coarse-grained CASS specimens that were previously inspected by an older generation 500-kHz PA-UT probe and acquisition instrument configuration. This comparative study describes the impact of the new PA probe design on flaw detection and sizing in a low signal-to-noise environment. The set of Pressurized Water Reactor Owners Group (PWROG) CASS specimens examined in this study are greater than 50.8-mm (2.0-in.) thick with documented flaws and microstructures. These specimens are on loan to PNNL from the Electric Power Research Institute (EPRI) NDE Center in Charlotte, North Carolina. The flaws contained within these specimens are thermal fatigue cracks (TFC) or mechanical fatigue cracks (MFC) and range from 13% to 42% in through-wall extent. In addition, ultrasonic signal continuity was evaluated on two CASS parent material ring sections by examining the edge-of-pipe response (corner geometry) for regions of signal loss.
Take a strong magnet and drop it down a copper pipe. You'll notice that the magnet falls slower due to magnetic induction. But, what happens if you cool the copper pipe with liquid nitrogen? Follow-up video! What happens if the MAGNETS are cooled with liquid nitrogen?? --- https://youtu.be/bu4_WW64-Sw
Heat pipes are highly effective devices used to passively transport heat by two-phase capillary action. Their small footprint, light weight and lack of moving parts make them ideal for transportable nuclear microreactors, where size and weight are limited, minimal to no operation and maintenance are required, and high reliability is desired. The use of additive manufacturing allows for the fabrication of heat pipes with performance enhancements, such as microchannels, grooves, arteries, or tailored porosity, which are difficult, expensive or impossible to achieve with traditional fabrication techniques. We are evaluating the capabilities of the Admaflex 130 Digital Light Printer to produce these geometries by characterizing feature shrinkage, developing an optimal heat treatment recipe, assessing the effects of heat treatment atmosphere and varying print orientation. Computational simulations are being used to estimate performance of the various 3D printed configurations.