Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Experiment definition and integration study for the accommodation of giant, passive detector of Exotic Particles In the Cosmic Rays (EPIC) payload on shuttle/spacelab missions

The feasibility of the design, construction, launch and retrieval of a hinged 15 ft by 110 ft the platform containing an array of interleaved CR-39 and Lexan track-recording detectors to be placed into circular orbit by space shuttle is assessed. The total weight of the detector assembly plus supporting structure and accessories is 32,000 pounds. The modular construction permits as little as one fourth of the payload to be exposed at one time. The CR-39 detector has sensitivity adequate to detect and study cosmic rays ranging from minimum ionizing iron-group nuclei to the heaviest elements. The detectors will survive a one year exposure to trapped protons without losing their high resolution. Advantages include low cost, huge collecting power (approximately 150 sq m) as well as the high resolution previously attainable only with electronic detectors.

Price, P. B.↗

Searching for Short-Lived Particles Using the FASER Neutrino Detector

Short-lived particles such as $\tau$ leptons and charm hadrons produced from high-energy neutrino interactions can provide key insights into the Standard Model and beyond. In this study, initial results of the performance of dedicated search tools developed for FASERν are presented. For charged charm searches, all daughter tracks are identified for ~3/4 of the events. Advanced yet reliable machine learning tools are used for D0 detection. For $\tau$ searches, a signal / background ratio of 3.8 is achieved. These results are a major step towards discovering the first charm hadrons and $\tau$ leptons produced from collider neutrinos.

Thor, Simon [CERN] (ORCID:000000029183526X)↗

Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors

Here, we present results of beam tests of charged particle detectors based on single-crystal and poly-crystalline Chemical Vapor Deposition (CVD) diamond. We measured the signal pulse height dependence on the particle flux. The detectors were tested over a range of particle fluxes from 2 kHz/cm 2 to 20 MHz/cm 2 . The pulse height of the sensors was measured with pad and pixel readout electronics. The pulse height of the non-irradiated single-crystal CVD diamond pad sensors was stable with respect to flux, while the pulse height of irradiated single-crystal CVD diamond pad sensors decreased with increasing particle flux. The pulse height of the non-irradiated single-crystal CVD diamond pixel detectors decreased slightly with increasing particle flux while the pulse height of the irradiated single-crystal CVD diamond pixel detectors decreased significantly with increasing particle flux. The observed sensitivity to flux is similar in both the diamond pad sensors constructed using diamonds from the Pixel Luminosity Telescope (PLT) irradiated during its pilot run in the Compact Muon Solenoid (CMS) detector and in neutron irradiated diamond pad sensors from the same manufacturer irradiated to the same fluence of neutrons. The pulse height for irradiated poly-crystalline CVD diamond pad sensors proved to be stable with respect to particle flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detector using lithiated glass-scintillating particle composite

A neutron detector composed of a matrix of scintillating particles imbedded in a lithiated glass is disclosed. The neutron detector detects the neutrons by absorbing the neutron in the lithium-6 isotope which has been enriched from the natural isotopic ratio to a commercial ninety five percent. The utility of the detector is optimized by suitably selecting scintillating particle sizes in the range of the alpha and the triton. Nominal particle sizes are in the range of five to twenty five microns depending upon the specific scintillating particle selected.

47 OTHER INSTRUMENTATION↗

Stardust Encounters Comet 81P/Wild 2

Stardust successfully encountered comet 81P/Wild 2 on 2 January 2004 at a distance of 236.4 +/- 1 km. All encounter investigations acquired valuable new and surprising findings. The time-of-flight spectrometer registered 29 spectra during flyby and measured the first negative ion mass spectra of cometary particles. The dust detectors recorded particles over a broad mass range, 10(exp -11) to 10(exp -4) g. Unexpectedly, the dust distribution along Stardust's flight path was far from uniform, but instead occurred in short 'bursts', suggesting in-flight breakup of fragments ejected from the nucleus. High-resolution, stunning images of the Wild 2 surface show a diverse and complex variety of landforms not seen from comets 1P/Halley and 19P/Borrelly or icy satellites of the outer solar system. Longer-exposure images reveal large numbers of jets projected nearly around the entire perimeter of the nucleus, many of which appear to be highly collimated. A triaxial ellipsoidal fit of the Wild 2 nucleus images yields the principal nucleus radii of 1.65 X 2.00 X2.75 km (+/- 0.05 km). The orientations and source locations on the nucleus surface of 20 highly collimated and partially overlapping jets have been traced. There is every indication that the expected samples were successfully collected from the Wild 2 coma and are poised for a return to Earth on 15 January 2006.

Stardust mission↗

Systematic measurements of identified particle spectra in pp, d+Au, and Au+Au collisions at the STAR detector

Identified charged-particle spectra of {pi}{sup {+-}}, K{sup {+-}}, p, and p at midrapidity (|y|<0.1) measured by the dE/dx method in the STAR (solenoidal tracker at the BNL Relativistic Heavy Ion Collider) time projection chamber are reported for pp and d+Au collisions at {radical}(s{sub NN})=200 GeV and for Au+Au collisions at 62.4, 130, and 200 GeV. Average transverse momenta, total particle production, particle yield ratios, strangeness, and baryon production rates are investigated as a function of the collision system and centrality. The transverse momentum spectra are found to be flatter for heavy particles than for light particles in all collision systems; the effect is more prominent for more central collisions. The extracted average transverse momentum of each particle species follows a trend determined by the total charged-particle multiplicity density. The Bjorken energy density estimate is at least several GeV/fm{sup 3} for a formation time less than 1 fm/c. A significantly larger net-baryon density and a stronger increase of the net-baryon density with centrality are found in Au+Au collisions at 62.4 GeV than at the two higher energies. Antibaryon production relative to total particle multiplicity is found to be constant over centrality, but increases with the collision energy. Strangeness production relative to total particle multiplicity is similar at the three measured RHIC energies. Relative strangeness production increases quickly with centrality in peripheral Au+Au collisions, to a value about 50% above the pp value, and remains rather constant in more central collisions. Bulk freeze-out properties are extracted from thermal equilibrium model and hydrodynamics-motivated blast-wave model fits to the data. Resonance decays are found to have little effect on the extracted kinetic freeze-out parameters because of the transverse momentum range of our measurements. The extracted chemical freeze-out temperature is constant, independent of collision system or centrality; its value is close to the predicted phase-transition temperature, suggesting that chemical freeze-out happens in the vicinity of hadronization and the chemical freeze-out temperature is universal despite the vastly different initial conditions in the collision systems. The extracted kinetic freeze-out temperature, while similar to the chemical freeze-out temperature in pp, d+Au, and peripheral Au+Au collisions, drops significantly with centrality in Au+Au collisions, whereas the extracted transverse radial flow velocity increases rapidly with centrality. There appears to be a prolonged period of particle elastic scatterings from chemical to kinetic freeze-out in central Au+Au collisions. The bulk properties extracted at chemical and kinetic freeze-out are observed to evolve smoothly over the measured energy range, collision systems, and collision centralities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perovskite CsPbBr 3 Single Crystal Detector for Alpha-Particle Spectroscopy.

Here we report the first spectroscopic alpha particle detection based on CsPbBr 3 detectors with asymmetric contacts. The CsPbBr 3 single crystal was grown from melt using Bridgman method and then fabricated into detectors with different contacts. The In/CsPbBr 3 /Au detector presented a low dark current (~100 nA/cm 2 ) and temporal stable performance under high electric field (1000 V/cm). Such detector demonstrated excellent gamma ray resolving capability with a full-width at half maximum (FWHM) of ~5.9 keV for the 57 Co 122 keV γ ray. The CsPbBr 3 detector was capable of simultaneously resolving both the alpha particle (5.5 MeV) and γ ray (59.5 keV) peaks from 241 Am radiative isotope. The transport properties of CsPbBr 3 were then determined based on the alpha particle spectra and corresponding rise time distributions. The equivalent values of electron and hole mobilities were indicated as 63 and 49 cm 2 /(V∙s) respectively. The calculated electron and hole mobility-lifetime products were 4.5 x 10 -4 and 9.5 x 10 -4 cm 2 /V, respectively, demonstrating superior transport properties of holes over electrons in CsPbBr 3 . As a result, this work widens the scope of perovskite detectors to encompass charged radiation as well as high energy X/γ rays, and will significantly promote and guide further studies on perovskite materials for radiation detection applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗