Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

In this study, the Building America team, IBACOS, sought to determine cost-effective, energy-efficient solutions for heating and cooling houses. To this end, the team performed field testing in a retrofit unoccupied test house in Fresno, California, to evaluate three air-based heating, ventilation, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. These included a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems -- a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms -- were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar particle event organ doses and dose equivalents for interplanetary crews: variations due to body size

Proper assessments of spacecraft shielding requirements and concomitant estimates of risk to critical body organs of spacecraft crews from energetic space radiation require accurate, quantitative methods of characterizing the compositional changes in these radiation fields as they pass through the spacecraft and overlying tissue. When estimating astronaut radiation organ doses and dose equivalents it is customary to use the Computerized Anatomical Man (CAM) model of human geometry to account for body self-shielding. Usually, the distribution for the 50th percentile man (175 cm height; 70 kg mass) is used. Most male members of the U.S. astronaut corps are taller and nearly all have heights that deviate from the 175 cm mean. In this work, estimates of critical organ doses and dose equivalents for interplanetary crews exposed to an event similar to the October 1989 solar particle event are presented for male body sizes that vary from the 5th to the 95th percentiles. Overall the results suggest that calculations of organ dose and dose equivalent may vary by as much as approximately 15% as body size is varied from the 5th to the 95th percentile in the population used to derive the CAM model data. c2002 Published by Elsevier Science Ltd on behalf of COSPAR.

NASA Discipline Radiation Health↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring and Modeling Astronaut Occupational Radiation Exposures in Space: Recent Advances

In 1982 astronauts were declared to be radiation workers by OSHA, and as such were subject to the rules and regulations applied to that group. NASA was already aware that space radiation was a hazard to crewmembers and had been studying and monitoring astronaut doses since 1962 at the Johnson Space Center. It was quickly realized NASA would not be able to accomplish all of its goals if the astronauts were subject to the ground based radiation worker limits, and thus received a waiver from OSHA to establish independent limits. As part of the stipulation attached to setting new limits, OSHA included a requirement to perform preflight dose projections for each crew and inform them of the associated risks. Additional requirements included measuring doses from various sources during the flight, making every effort to prevent a crewmember from exceeding the new limits, and keeping all exposures As Low As Reasonably Achievable (a.k.a. ALARA - a common health physics principle). The assembly of the International Space Station (ISS) and its initial manned operations will coincide with the 4-5 year period of high space weather activity at the next maximum in the solar cycle. For the first time in NASA's manned program, US astronauts will be in orbit continuously throughout a solar maximum period. During this period, crews are at risk of significantly increased radiation exposures due to solar particle events and trapped electron belt enhancements following geomagnetic storms. The problem of protecting crews is compounded by the difficulty of providing continuous real-time monitoring over a period of a decade in an era of tightly constrained budgets. In order to prepare for ISS radiological support needs, the NASA Space Radiation Analysis Group and the NOAA Space Environment Center have undertaken a multiyear effort to improve and automate ground-based space weather monitoring systems and real-time radiation analysis tools. These improvements include a coupled, automated space weather monitoring and alarm system--SPE exposure analysis system, an advanced space weather data distribution and display system, and a high-fidelity space weather simulation system. In addition, significant new real-time space weather data sets, which will enhance the forecasting and now-casting of near-Earth space environment conditions, are being made available through unique NASA-NOAA-USAF collaborations. These new data sets include coronal mass ejection monitoring by the Solar and Heliospheric Observatory (SOHO) and in-situ plasma and particle monitoring at the L1 libration point by the Solar Wind Monitor (SWIM) and Advanced Composition Explorer (ACE) spacecraft. Advanced real-time radiation monitoring data from charged particle telescopes and tissue equivalent proportional counters will also be available to assist crew and flight controllers in monitoring the external and intravehicular radiation environment.

Weyland, Mark↗

The incidence of burnout or compassion fatigue in medical dosimetrists as a function of various stress and psychologic factors

ABSTRACT: Burnout and compassion fatigue (CF) adversely affect medical professionals, including those employed in radiation oncology. Previously conducted research acknowledged the presence of burnout in populations of radiation therapists, radiation oncologists, and oncology nursing staff. The aim of the following research was to measure the incidence of burnout or CF in the specific population of medical dosimetrists surveyed. As professional members of the radiation oncology team, this group had not been included in published research data to date. The hypothesis of the subsequent study stated that a comparable incidence of burnout would be observed among medical dosimetrists as had been reported by earlier researchers for a population of radiation therapists. A survey tool based on the Maslach Burnout Inventory (MBI) and distributed to full members of the American Association of Medical Dosimetrists (AAMD) was utilized as the research measurement method. Results obtained indicated an incidence rates of burnout or CF for medical dosimetrists were less than the rates previously measured for radiation therapists (53% vs 11% for emotional exhaustion [EE] and 45% vs 27% for depersonalization [DP]). The incidence of burnout was based on the Burnout Inventory (BI) developed for the research project. Each of the subscales, EE, DP, and decreased personal accomplishment (PA), was considered and analyzed independently. Although not as prevalent among medical dosimetrists as a variety of additional radiation oncology professionals, a significant portion of the population demonstrated signs of burnout or CF. Future concerns abound for the population of medical dosimetrists as a large number of members scored positive for intermediate risk of burnout and CF. Additionally, a large portion of the population was found to be rapidly approaching retirement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Moving Evidence Forward: Addressing the Barriers to Evidence-Based Practice in Radiotherapy

Improving the quality of care is an ongoing challenge for medical professionals in the Canadian healthcare system. One generally accepted method of improving health outcomes has been the clinical implementation of evidence-based practice. Historically, the barrier in clinical settings has been efficient access to reliable information. Point-of-care (P-O-C) tools have been proven to be effective and help promote evidence-based practice in professions outside radiation therapy. To examine the potential usefulness of a P-O-C tool for radiation therapists, a Canada-wide survey was distributed to practicing radiation therapists. Results showed a clear desire by radiation therapists for a P-O-C tool. Sixty-nine percent of surveyed practitioners stated that having a practitioner-focused evidence resource would change their daily work practice, but stipulated that the proper integration of resources into the day-to-day workplace is crucial to supporting clinical evidence-based decision-making. Study participants also highlighted several barriers to their ability to do so, including access to evidence-based data, differing organizational research philosophies and practices, lack of resources to promote discipline-specific practitioner research, and necessary integration of educational and mentoring programs into daily practices. Although they have not been found to be an all-encompassing remedy, P-O-C tools have the potential to aid front-line healthcare providers in fostering evidence-based practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using DNA Damage to Investigate the Individual Variability of Human Sensitivity to Ionizing Radiation

High-LET ionizing radiation is a major occupational health hazard for astronauts, but risk assessment remains elusive due to limited epidemiological data. Identifying genetic factors modulating the individual radiation response may be the most effective strategy to provide individualized risk management for long-duration high-radiation missions. We have started tackling the challenge of predicting individual risks by identifying human genetic loci associated with various radiation sensitivity phenotypes in primary blood mononuclear cells from a relatively large healthy human cohort. To date, we have performed the isolation of PBMCs from 768 subjects of the same ethnicity, and irradiated PBMCs from 576 subjects with 1 and 3 particles/100µm2 of 600 MeV/n 56Fe, 350 MeV/n 40Ar and 350 MeV/n 28Si ions. The phenotypes of interest were: number of radiation-induced foci (or RIFs), CellROX oxidative stress responses and cell death, at 4h and 24h following irradiation. We have observed a significant inter-individual variability at 0 Gy between the 576 studied subjects, with a mean fold difference between the 10% lowest and highest responders of 5.6 of RIFs/cell, 7.9 in mean CellRox intensity, and 9.3 in percentage of dead cells. In order to better assess genetic factors influencing DNA repair, we used a metric previously introduced by our group to sort out radiation sensitivity phenotypes in mice: i.e. the ratio of the first to the second slope of RIFs/cell (between 0 and 1, and between 1 and 3 particle/100µm2). Preliminary data on 192 individuals showed a distribution of low-dose responders (ratio > 1) to high-dose responders (ratio < 1) at 4h of 12%, 55% and 52% respectively for Fe, Ar and Si. The average value for the first and the second slopes was very similar for the two lowest LET (0.10 [-0.26;0.58] and 0.09 [-0.45;0.41] for Ar, 0.07 [-0.27;0.38] and 0.08 [-0.19;0.42] for Si), indicating a linear dose response across both fluence. Fe showed clear saturation for the highest dose with a slope of -0.09 [-0.86;1.51] against 0.68 [-2.21;2.20] for the low dose range, which probably reflects that many PBMCs are beyond repair at the high dose. Note that other significances were found for additional factors such as BMI and age whereas none were found for sex. GWAS will be performed on all phenotypes upon completion of measurements.

Pariset, E.↗

Using DNA Damage to Investigate the Individual Variability of Human Sensitivity to Ionizing Radiation

High-LET ionizing radiation is a major occupational health hazard for astronauts, but risk assessment remains elusive due to limited epidemiological data. Identifying genetic factors modulating the individual radiation response may be the most effective strategy to provide individualized risk management for long-duration high-radiation missions. We have started tackling the challenge of predicting individual risks by identifying human genetic loci associated with various radiation sensitivity phenotypes in primary blood mononuclear cells from a relatively large healthy human cohort. To date, we have performed the isolation of PBMCs from 768 subjects of the same ethnicity, and irradiated PBMCs from 576 subjects with 1 and 3 particles/100µm2 of 600 MeV/n 56Fe, 350 MeV/n 40Ar and 350 MeV/n 28Si ions. The phenotypes of interest were: number of radiation-induced foci (or RIFs), CellROX oxidative stress responses and cell death, at 4h and 24h following irradiation. We have observed a significant inter-individual variability at 0 Gy between the 576 studied subjects, with a mean fold difference between the 10% lowest and highest responders of 5.6 of RIFs/cell, 7.9 in mean CellRox intensity, and 9.3 in percentage of dead cells. In order to better assess genetic factors influencing DNA repair, we used a metric previously introduced by our group to sort out radiation sensitivity phenotypes in mice: i.e. the ratio of the first to the second slope of RIFs/cell (between 0 and 1, and between 1 and 3 particle/100µm2). Preliminary data on 192 individuals showed a distribution of ?low-dose responders? (ratio > 1) to ?high-dose responders? (ratio < 1) at 4h of 12%, 55% and 52% respectively for Fe, Ar and Si. The average value for the first and the second slopes was very similar for the two lowest LET (0.10 [-0.26;0.58] and 0.09 [-0.45;0.41] for Ar, 0.07 [-0.27;0.38] and 0.08 [-0.19;0.42] for Si), indicating a linear dose response across both fluence. Fe showed clear saturation for the highest dose with a slope of -0.09 [-0.86;1.51] against 0.68 [-2.21;2.20] for the low dose range, which probably reflects that many PBMCs are beyond repair at the high dose. Note that other significances were found for additional factors ? such as BMI and age ? whereas none were found for sex. GWAS will be performed on all phenotypes upon completion of measurements.

Pariset, E.↗

Electronic Structure Theory and Novel Materials

This grant supported research on electronic structure and materials theory, with focus on three main issues: (i) novel techniques to deal with correlation in the electronic ground-state, (ii) topological materials, (iii) the phase diagram of lattice spin models. Regarding (i), we applied to the homogeneous electron liquid an approach that we previously developed in the context of molecular systems. In this scheme the electronic occupation probabilities and the natural spin orbitals are used to construct an approximate two-body density matrix for the electronic ground-state. Regarding (ii) we used standard electronic structure methods based on density functional theory to model topological materials and interpret experimental observations. Finally, regarding (iii) we further developed a numerical approach to compute the renormalized couplings within real space renormalization group theory in the context of lattice spin models. The main findings were the following. (i) We found that with our approximate two-body density matrix, which works well for small molecules, is not sufficiently accurate for condensed phase systems. Missing a systematic way of improving on the adopted approximations, we decided not to pursue this approach. (ii) We performed two studies. In one, we investigated the influence of Te defects on the topological properties of a WTe2 monolayer, finding that while Te vacancies, even in modest concentration, destroy the topological character, Te adatoms do not, consistent with a recent experiment. In another study, we predicted Weyl semimetal character and strong anomalous Hall effect in the Heusler compensated ferrimagnet Ti2MnAl. (iii) We developed a new Monte Carlo method to do real space renormalization group calculations for lattice spin models. We subsequently extended the scheme to deal with lattice spin models in presence of quenched disorder, finding that the approach can distinguish systems with finite and strong disorder. In the finite disorder case, the method allows one to find with good approximation the critical coupling distribution and the critical exponents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure-composition sensitivity in 'Metallic' Zintl phases: A study of Eu(Ga{sub 1-x}Tt{sub x}){sub 2} (Tt=Si, Ge, 0<=x<=1)

Two isoelectronic series, Eu(Ga{sub 1-x}Tt{sub x}){sub 2} (Tt=Si, Ge, 0<=x<=1), have been synthesized and characterized by powder and single-crystal X-ray diffraction, physical property measurements, and electronic structure calculations. In Eu(Ga{sub 1-x}Si{sub x}){sub 2}, crystal structures vary from the KHg{sub 2}-type to the AlB{sub 2}-type, and, finally, the ThSi{sub 2}-type structure as x increases. The hexagonal AlB{sub 2}-type structure is identified for compositions 0.18(2)<=x<0.70(2) with Ga and Si atoms statistically distributed in the polyanionic 6{sup 3} nets. As smaller Si atoms replace Ga atoms while the number of valence electrons increases, the lattice parameters, unit cell volumes, and Ga-Si distances in this phase region decrease significantly. Although aspects of X-ray diffraction results suggest puckering of the 6{sup 3} nets for the Si-richest example of the AlB{sub 2}-type Eu(Ga{sub 1-x}Si{sub x}){sub 2}, the complete experimental evidence remains inconclusive. On the other hand, in Eu(Ga{sub 1-x}Ge{sub x}){sub 2}, six different structural types were observed as x varies. In addition to EuGa{sub 2} (KHg{sub 2}-type; space group Imma) and EuGe{sub 2} (own structure type, space group P3-barm1), the ternary phases studied show four different structures: the AlB{sub 2}-type for Ga-rich compositions; the YPtAs-type structure for EuGaGe; and two new structures, which are intergrowths of the YPtAs-type EuGaGe and EuGe{sub 2}, for Ge-rich compositions. These two Ge-rich phases include: (1) Eu(Ga{sub 0.45(2)}Ge{sub 0.55(2)}){sub 2} containing two YPtAs-type motifs of EuGaGe plus one EuGe{sub 2} motif; and (2) Eu(Ga{sub 0.40(2)}Ge{sub 0.60(2)}){sub 2} containing one YPtAs-type motif alternating with a split site at x=2/3 ,y=1/3 and z=0.4798(2) with ca. 50% site occupancy by Ga and Ge along the c-axis. Magnetic susceptibilities of three Eu(Ga{sub 1-x}Ge{sub x}){sub 2} compounds display Curie-Weiss behavior above ca. 100 K, and show effective magnetic moments indicative of divalent Eu with a 4f{sup 7} electronic configuration, consistent with. X-ray absorption spectra (XAS). Density of states (DOS) and crystal orbital Hamilton population (COHP) analyses, based on first principles electronic structure calculations, rationalize the observed homogeneity ranges of the AlB{sub 2}-type phases in both systems and the structural variations as a function of Tt content. - Abstract: A study of Eu(Ga{sub 1-x}Si{sub x}){sub 2} and Eu(Ga{sub 1-x}Ge{sub x}){sub 2} shows different compositional ranges for puckering of 6{sup 3} nets and, for the germanides, two new commensurately modulated superstructures. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanism of Lithium Ion Exchange Into Spinel Manganese Oxide

Lithium manganese oxide (LMO) is an effective absorbent for lithium recovery from brines, characterized by its high adsorption capacity, excellent regeneration performance, and selectivity. Here, this study investigates the mechanisms of material degradation during lithium loading and unloading in LMO, employing a combination of time‐resolved Raman spectroscopy, X‐ray diffraction, and X‐ray photoelectron spectroscopy. Key findings reveal that the A 1g vibrational mode wavenumber shifts from 635 cm −1 at the onset of lithium ion exchange to 656 cm −1 after 12 min, indicating local symmetry loss and manganese (Mn) loss during lithium intercalation. The proposed lithium exchange mechanism involves initial occupation of tetrahedral interstitial voids, followed by migration into interstitial sites between Mn octahedral sites. Computational modeling suggests that the loss of symmetry in MnO cubane‐like groups occurs as lithium migrates, significantly affecting the Raman spectra. Importantly, the study demonstrates that after 100 cycles of lithium/hydrogen loading, a 24% loss in Mn is observed, which correlates with decreased structural stability; however, the structural integrity of LMO is enhanced when subjected to multiple cycles without complete loading. Here, these insights contribute to the understanding of LMO's performance in lithium recovery applications and highlight potential strategies to optimize its use in future technologies.

15 GEOTHERMAL ENERGY↗

Nanoquartz in Late Permian C1 coal and the high incidence of female lung cancer in the Pearl River Origin area: a retrospective cohort study

Background: The Pearl River Origin area, Qujing District of Yunnan Province, has one of the highest female lung cancer mortality rates in China. Smoking was excluded as a cause of the lung cancer excess because almost all women were non-smokers. Crystalline silica embedded in the soot emissions from coal combustion was found to be associated with the lung cancer risk in a geographical correlation study. Lung cancer rates tend to be higher in places where the Late Permian C1 coal is produced. Therefore, we have hypothesized the two processes: C1 coal combustion --> nanoquartz in ambient air --> lung cancer excess in non-smoking women. Methods/Design: We propose to conduct a retrospective cohort study to test the hypothesis above. We will search historical records and compile an inventory of the coal mines in operation during 1930–2009. To estimate the study subjects' retrospective exposure, we will reconstruct the historical exposure scenario by burning the coal samples, collected from operating or deserted coal mines by coal geologists, in a traditional firepit of an old house. Indoor air particulate samples will be collected for nanoquartz and polycyclic aromatic hydrocarbons (PAHs) analyses. Bulk quartz content will be quantified by X-ray diffraction analysis. Size distribution of quartz will be examined by electron microscopes and by centrifugation techniques. Lifetime cumulative exposure to nanoquartz will be estimated for each subject. Using the epidemiology data, we will examine whether the use of C1 coal and the cumulative exposure to nanoquartz are associated with an elevated risk of lung cancer. Discussion: The high incidence rate of lung cancer in Xuan Wei, one of the counties in the current study area, was once attributed to high indoor air concentrations of PAHs. The research results have been cited for qualitative and quantitative cancer risk assessment of PAHs by the World Health Organization and other agencies. If nanoquartz is found to be the main underlying cause of the lung cancer epidemic in the study area, cancer potency estimates for PAHs by the international agencies based on the lung cancer data in this study setting should then be updated.

59 BASIC BIOLOGICAL SCIENCES↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

The flexibility gap: Socioeconomic and geographical factors driving residential flexibility

Residential consumers are moving to the center of electricity systems and their flexibility is seen as a key resource to integrate renewable energy sources and support the grid. However, residential flexibility capacities are not homogeneous, as they depend on household appliances, comfort patterns, occupancy, and climate conditions. In this work, we calculate the technical flexibility capacities of 45 consumer types in mainland Spain, organised according to income and regional criteria. We show that flexibility gaps exist at both regional and socioeconomic (income) levels with flexibility differences of up to 10 times more capacity between the household groups from the lowest to the highest capacities. These geographical and socioeconomic gaps in flexibility can lead to distortions in national markets and have the potential to exclude citizens from the provision of flexibility services. Our results show in quantitative terms that a consumer-centered approach without considering correcting measures nor these gaps in drafting energy policies may lead to increasing inequality levels in the residential sector. Under an economic competitive paradigm, households with lower income levels or located in regions with lower flexibility potential may be excluded from the provision of flexibility to the detriment of households with larger potential, raising justice concerns in a flexibility-based energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reconstructing Hanford worker external doses from photons for epidemiology

The accurate reconstruction of external photon doses is essential for credible radiation epidemiology. This article presents the methodology used to derive dose estimates for 37 012 Hanford Site workers included in the Million Person Study. The approach employs historical dose records from the Hanford Radiation Exposure database and a previous epidemiology study. Bias correction factors specific to dosimeter type and period of use were applied and missing annual doses were estimated using a hierarchical nearby method to estimate deep dose equivalent for each worker. For early years with limited detection sensitivity, missed doses were quantified based on expected time-period-specific, low-dose statistical distributions. The revised dose estimates resulted in lower median and mean career doses than unadjusted data, while increasing the number of person-years with nonzero dose. Sensitivity analyses assessed the influence of bias in dosimetry measurements, missed doses and gap years on dose estimates. Differences in cumulative dose estimates between unadjusted and revised annual estimates are most prominent in the early operational years due to the highest bias during that time period.

dose reconstruction↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

Quasi-Fermi level splitting and sub-bandgap absorptivity from semiconductor photoluminescence

A unified model for the direct gap absorption coefficient (band-edge and sub-bandgap) is developed that encompasses the functional forms of the Urbach, Thomas-Fermi, screened Thomas-Fermi, and Franz-Keldysh models of sub-bandgap absorption as specific cases. We combine this model of absorption with an occupation-corrected non-equilibrium Planck law for the spontaneous emission of photons to yield a model of photoluminescence (PL) with broad applicability to band-band photoluminescence from intrinsic, heavily doped, and strongly compensated semiconductors. The utility of the model is that it is amenable to full-spectrum fitting of absolute intensity PL data and yields: (1) the quasi-Fermi level splitting, (2) the local lattice temperature, (3) the direct bandgap, (4) the functional form of the sub-bandgap absorption, and (5) the energy broadening parameter (Urbach energy, magnitude of potential fluctuations, etc.). The accuracy of the model is demonstrated by fitting the room temperature PL spectrum of GaAs. It is then applied to Cu(In,Ga)(S,Se){sub 2} (CIGSSe) and Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe) to reveal the nature of their tail states. For GaAs, the model fit is excellent, and fitted parameters match literature values for the bandgap (1.42 eV), functional form of the sub-bandgap states (purely Urbach in nature), and energy broadening parameter (Urbach energy of 9.4 meV). For CIGSSe and CZTSSe, the model fits yield quasi-Fermi leveling splittings that match well with the open circuit voltages measured on devices made from the same materials and bandgaps that match well with those extracted from EQE measurements on the devices. The power of the exponential decay of the absorption coefficient into the bandgap is found to be in the range of 1.2 to 1.6, suggesting that tunneling in the presence of local electrostatic potential fluctuations is a dominant factor contributing to the sub-bandgap absorption by either purely electrostatic (screened Thomas-Fermi) or a photon-assisted tunneling mechanism (Franz-Keldysh). A Gaussian distribution of bandgaps (local E{sub g} fluctuation) is found to be inconsistent with the data. The sub-bandgap absorption of the CZTSSe absorber is found to be larger than that for CIGSSe for materials that yield roughly equivalent photovoltaic devices (8% efficient). Further, it is shown that fitting only portions of the PL spectrum (e.g., low energy for energy broadening parameter and high energy for quasi-Fermi level splitting) may lead to significant errors for materials with substantial sub-bandgap absorption and emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗