Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Structural, electrochemical and magnetic characterization of the layered-type PrBa{sub 0.5}Sr{sub 0.5}Co{sub 2}O{sub 5+δ} perovskite

Structural, electrical and magnetic properties of the layered cobaltite PrBa{sub 0.5}Sr{sub 0.5}Co{sub 2}O{sub 5+δ} have been investigated by means of neutron diffraction, electron diffraction, thermogravimetric analysis and SQUID magnetometry. Rietveld analysis of neutron diffraction data shows the ordered distribution of oxygen vacancies in [PrO{sub δ}] planes which doubles the lattice parameters from the simple perovskite cell parameter as a≈2a{sub p} and c≈2a{sub p} (a{sub p} is the cell parameter of the simple Perovskite) yielding tetragonal symmetry in the P4/mmm space group. On heating, above 573 K in air, structural rearrangement takes place and the structure can be defined as a≈a{sub p} and c≈2a{sub p} in the same space group. Oxygen occupancies have been determined as a function of temperature from neutron diffraction results. Initially (≥373 K), oxygen occupancy was increased and then decreased with increasing temperature. It was found that at 973 K the total oxygen loss is calculated about 0.265 oxygen/formula unit. Oxygen vacancy ordering was observed below 573 K, and the oxygen occupancy decreases as cell volume increases with increasing temperature. Area specific resistance (ASR) measurements show a resistance of 0.153 Ωcm{sup 2} and 0.286 Ωcm{sup 2} at 973 K and 923 K, respectively. On cooling, paramagnetic to ferromagnetic and an incomplete ferromagnetic to antiferromagnetic transition takes place. Different behaviours in field cooled and zero-field-cooled measurements leads to a coexistence of ferromagnetic and antiferromagnetic order. - Graphical abstract: Structural phase changes in PrBa{sub 0.5}Sr{sub 0.5}Co{sub 2}O{sub 5+δ} at elevated temperatures determined by neutron powder diffraction. Depending on oxygen occupancy it form different phases at different temperatures. This pictures show the schematic 3D diagram of PrBa{sub 0.5}Sr{sub 0.5}Co{sub 2}O{sub 5+δ} at 295 K (a), 373 K (b) and 573 K (c). Co atoms are inside the octahedra/pyramid. Ba and Sr occupy the same site. Oxygens are in the corner of polyhedra. - Highlights: • Structural phase changes at high temperatures. • Ordered distribution of oxygen vacancies below 573 K. • Double Perovskite type structure below 373 K in the P4/mmm space group. • Structural changes have direct correlation with conductivity. • Low area specific resistance at 973 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-Principles Study of Spinel MgTiS 2 as a Cathode Material

Spinel intercalation hosts are well known to to facilitate high rate capability and high voltage Li-ion batteries. A recent experimental study has shown that Mg can reversibly intercalate in spinel TiS 2 , demonstrating the viability of Li intercalation host crystal structures for Mg-ion batteries. We report on a first-principles statistical mechanics study of Mg insertion into spinel TiS 2 , accounting for occupancy on both octahedrally and tetrahedrally coordinated interstitial sites. In contrast to Li-containing spinels, we predict mixed octahedral and tetrahedral site occupancy at nondilute Mg concentrations consistent with the recent experimental study of Sun et al. The onset of mixed occupancy is correlated with an increase in the spinel volume upon Mg insertion, which is more pronounced in MgxTiS 2 than in its Li counterpart. Lastly, the results in this study suggest that the degree of mixed occupancy could be controlled through the volume of the host with addition of electrochemically inactive species.

25 ENERGY STORAGE↗

Principles of regulatory information conservation between mouse and human

To broaden our understanding of the evolution of gene regulation mechanisms, we generated occupancy profiles for 34 orthologous transcription factors (TFs) in human–mouse erythroid progenitor, lymphoblast and embryonic stem-cell lines. By combining the genome-wide transcription factor occupancy repertoires, associated epigenetic signals, and co-association patterns, here we deduce several evolutionary principles of gene regulatory features operating since the mouse and human lineages diverged. The genomic distribution profiles, primary binding motifs, chromatin states, and DNA methylation preferences are well conserved for TF-occupied sequences. However, the extent to which orthologous DNA segments are bound by orthologous TFs varies both among TFs and with genomic location: binding at promoters is more highly conserved than binding at distal elements. Notably, occupancy-conserved TF-occupied sequences tend to be pleiotropic; they function in several tissues and also co-associate with many TFs. Lastly, single nucleotide variants at sites with potential regulatory functions are enriched in occupancy-conserved TF-occupied sequences.

60 APPLIED LIFE SCIENCES↗

Surface triggered stabilization of metastable charge-ordered phase in SrTiO 3

Charge ordering (CO), characterized by a periodic modulation of electron density and lattice distortion, has been a fundamental topic in condensed matter physics, serving as a potential platform for inducing novel functional properties. The charge-ordered phase is known to occur in a doped system with high d-electron occupancy, rather than low occupancy. Here, we report the realization of the charge-ordered phase in electron-doped (100) SrTiO 3 epitaxial thin films that have the lowest d-electron occupancy i.e., d 1 -d 0 . Theoretical calculation predicts the presence of a metastable CO state in the bulk state of electron-doped SrTiO 3 . Atomic scale analysis reveals that (100) surface distortion favors electron-lattice coupling for the charge-ordered state, and triggering the stabilization of the CO phase from a correlated metal state. This stabilization extends up to six unit cells from the top surface to the interior. Our approach offers an insight into the means of stabilizing a new phase of matter, extending CO phase to the lowest electron occupancy and encompassing a wide range of 3d transition metal oxides.

36 MATERIALS SCIENCE↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The cosmic web of X-ray active galactic nuclei seen through the eROSITA Final Equatorial Depth Survey (eFEDS)

Which galaxies in the general population turn into active galactic nuclei (AGNs) is a keystone of galaxy formation and evolution. Thanks to SRG/eROSITA’s contiguous 140 square degree pilot survey field, we constructed a large, complete, and unbiased soft X-ray flux-limited (FX > 6.5 × 10 -15 erg s -1 cm -2 ) AGN sample at low redshift, 0.05 < z < 0.55. Two summary statistics, the clustering using spectra from SDSS-V and galaxy-galaxy lensing with imaging from HSC, are measured and interpreted with halo occupation distribution and abundance matching models. Both models successfully account for the observations. We obtain an exceptionally complete view of the AGN halo occupation distribution. The population of AGNs is broadly distributed among halos with a mean mass of 3.9 -2.4 +2.0 × 10 12 M ⊙ . This corresponds to a large-scale halo bias of b(z = 0.34) = 0.99 -0.10 +0.08 . The central occupation has a large transition parameter, σ log 10 (M) = 1.28 ± 0.2. The satellite occupation distribution is characterized by a shallow slope, α sat = 0.73 ± 0.38. We find that AGNs in satellites are rare, with f sat < 20%. Most soft X-ray-selected AGNs are hosted by central galaxies in their dark matter halo. A weak correlation between soft X-ray luminosity and large-scale halo bias is confirmed (3.3σ). We discuss the implications of environmental-dependent AGN triggering. This study paves the way toward fully charting, in the coming decade, the coevolution of X-ray AGNs, their host galaxies, and dark matter halos by combining eROSITA with SDSS-V, 4MOST, DESI, LSST, and Euclid data.

79 ASTRONOMY AND ASTROPHYSICS↗

Roughness effects in uncompensated antiferromagnets

Monte Carlo simulations show that roughness in uncompensated antiferromagnets decreases not just the surface magnetization but also the net magnetization and particularly strongly affects the temperature dependence. In films with step-type roughness, each step creates a new compensation front that decreases the global net magnetization. The saturation magnetization decreases non-monotonically with increasing roughness and does not scale with the surface area. Roughness in the form of surface vacancies changes the temperature-dependence of the magnetization; when only one surface has vacancies, the saturation magnetization will decrease linearly with surface occupancy, whereas when both surfaces have vacancies, the magnetization is negative and exhibits a compensation point at finite temperature, which can be tuned by controlling the occupancy. Roughness also affects the spin-texture of the surfaces due to long-range dipolar interactions and generates non-collinear spin configurations that could be used in devices to produce locally modified exchange bias. These results explain the strongly reduced magnetization found in magnetometry experiments and furthers our understanding of the temperature-dependence of exchange bias.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

How to optimally constrain galaxy assembly bias: supplement projected correlation functions with count-in-cells statistics

Most models for the statistical connection between galaxies and their haloes ignore the possibility that galaxy properties may be correlated with halo properties other than halo mass, a phenomenon known as galaxy assembly bias. And yet, it is known that such correlations can lead to systematic errors in the interpretation of survey data that are analysed using traditional halo occupation models. At present, the degree to which galaxy assembly bias may be present in the real Universe, and the best strategies for constraining it remain uncertain. We study the ability of several observables to constrain galaxy assembly bias from redshift survey data using the decorated halo occupation distribution (dHOD), an empirical model of the galaxy-halo connection that incorporates assembly bias. We cover an expansive set of observables, including the projected two-point correlation function w p ( r p ), the galaxy-galaxy lensing signal &Delta;Σ( r p ), the void probability function VPF( r ), the distributions of counts-in-cylinders P(NCIC), and counts-in-annuli P(NCIA), and the distribution of the ratio of counts in cylinders of different sizes P ( N 2 /N 5 ). We find that despite the frequent use of the combination w p ( r p ) + &Delta;Σ( r p ) in interpreting galaxy data, the count statistics, P ( N CIC ) and P ( N CIA ), are generally more efficient in constraining galaxy assembly bias when combined with w p ( r p ). Constraints based upon w p ( r p ) and &Delta;Σ(rp) share common degeneracy directions in the parameter space, while combinations of r p w p ( r p ) with the count statistics are more complementary. Therefore, we strongly suggest that count statistics should be used to complement the canonical observables in future studies of the galaxy-halo connection.

galaxies: evolution↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Incorporating Residential Smart Electric Vehicle Charging in Home Energy Management Systems

Electric vehicles (EVs) are expected to drastically increase residential electricity consumption and could provide a significant source of flexible demand. Aggregating smart EV charge controllers with other smart home devices through a home energy management system can lead to more optimal outcomes that benefit homeowners, utilities, and grid operators. Control strategies should consider occupant convenience by accounting for the need for fully charged EVs near the EV departure time. In this paper, we develop an EV charging framework that accounts for occupant convenience using OCHRE, a residential energy model, and foresee, a home energy management system. We simulate a community with high EV penetration and show that integrated, smart EV charging reduces peak demand and smooths night-time energy consumption. Simulation results show that the proposed control strategy nearly eliminates peak period EV charging and reduces the daily peak demand from EVs by 23%.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Fuzzy Linguistic Knowledge Based Behavior Extraction for Building Energy Management Systems

Significant portion of world energy production is consumed by building Heating, Ventilation and Air Conditioning (HVAC) units. Thus along with occupant comfort, energy efficiency is also an important factor in HVAC control. Modern buildings use advanced Multiple Input Multiple Output (MIMO) control schemes to realize these goals. However, since the performance of HVAC units is dependent on many criteria including uncertainties in weather, number of occupants, and thermal state, the performance of current state of the art systems are sub-optimal. Furthermore, because of the large number of sensors in buildings, and the high frequency of data collection, large amount of information is available. Therefore, important behavior of buildings that compromise energy efficiency or occupant comfort is difficult to identify. This paper presents an easy to use and understandable framework for identifying such behavior. The presented framework uses human understandable knowledge-base to extract important behavior of buildings and present it to users via a graphical user interface. The presented framework was tested on a building in the Pacific Northwest and was shown to be able to identify important behavior that relates to energy efficiency and occupant comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An over-approximation of entropy for elemental multiconfigurational ground state electronic structures

The ability to predict the chemical and physical properties of a material is directly related to the structure and interactions of its electrons. For materials comprised of f-block elements (the lanthanides and actinides found in the last two rows of the periodic table), the complexity of electronic structure has presented great difficulty in understanding, modeling, and predicting material properties. The complexity of multiconfigurational ground state electronic structures is illustrated herein by the combinatorics of electron permutations within individual and cumulative occupancy configurations. A non-integer orbital occupancy representation of multiconfigurational ground states is described for superposition mixing between multiple near-energy degenerate occupancy configurations and generalized in such a way that established ground states are returned by approximation for elements with less-complex electronic structures. By considering the occupancy configurations as statistical mechanics macrostates, and the permutations of electrons as statistical mechanics microstates within those macrostates, an over-approximation of entropy for multiconfigurational elemental ground state electronic structures has been calculated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concentrations and Sources of Airborne Particles in a Neonatal Intensive Care Unit

Premature infants in neonatal intensive care units (NICUs) have underdeveloped immune systems, making them susceptible to adverse health consequences from air pollutant exposure. Little is known about the sources of indoor airborne particles that contribute to the exposure of premature infants in the NICU environment. In this study, we monitored the spatial and temporal variations of airborne particulate matter concentrations along with other indoor environmental parameters and human occupancy. The experiments were conducted over one year in a private-style NICU. The NICU was served by a central heating, ventilation and air-conditioning (HVAC) system equipped with an economizer and a high-efficiency particle filtration system. The following parameters were measured continuously during weekdays with 1-min resolution: particles larger than 0.3 μm resolved into 6 size groups, CO 2 level, dry-bulb temperature and relative humidity, and presence or absence of occupants. Altogether, over sixteen periods of a few weeks each, measurements were conducted in rooms occupied with premature infants. In parallel, a second monitoring station was operated in a nearby hallway or at the local nurses’ station. The monitoring data suggest a strong link between indoor particle concentrations and human occupancy. Detected particle peaks from occupancy were clearly discernible among larger particles and imperceptible for submicron (0.3–1 μm) particles. The mean indoor particle mass concentrations averaged across the size range 0.3–10 μm during occupied periods was 1.9 μg/m 3 , approximately 2.5 times the concentration during unoccupied periods (0.8 μg/m 3 ). Contributions of within-room emissions to total PM10 mass in the baby rooms averaged 37–81%. Near-room indoor emissions and outdoor sources contributed 18–59% and 1–5%, respectively. Airborne particle levels in the size range 1–10 μm showed strong dependence on human activities, indicating the importance of indoor-generated particles for infant’s exposure to airborne particulate matter in the NICU.

60 APPLIED LIFE SCIENCES↗

Pollutant Exposures from Natural Gas Cooking Burners: A Simulation-Based Assessment for Southern California

Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants and they are typically used without venting. The objective of this study is to quantify pollutant concentrations and occupant exposures resulting from NGCB use in California homes. A mass balance model was applied to estimate time-dependent pollutant concentrations throughout homes and the "exposure concentrations" experienced by individual occupants. The model was applied to estimate nitrogen dioxide (NO{sub 2}), carbon monoxide (CO), and formaldehyde (HCHO) concentrations for one week each in summer and winter for a representative sample of Southern California homes. The model simulated pollutant emissions from NGCBs, NO{sub 2} and CO entry from outdoors, dilution throughout the home, and removal by ventilation and deposition. Residence characteristics and outdoor concentrations of CO and NO{sub 2} were obtained from available databases. Ventilation rates, occupancy patterns, and burner use were inferred from household characteristics. Proximity to the burner(s) and the benefits of using venting range hoods were also explored. Replicate model executions using independently generated sets of stochastic variable values yielded estimated pollutant concentration distributions with geometric means varying less than 10%. The simulation model estimates that in homes using NGCBs without coincident use of venting range hoods, 62%, 9%, and 53% of occupants are routinely exposed to NO{sub 2}, CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3000, and 20 ppb for NO{sub 2}, CO, and HCHO, respectively. Reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

03 NATURAL GAS↗