Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A rack-mounted precision waveguide-below-cutoff attenuator with an absolute electronic readout

A coaxial precision waveguide-below-cutoff attenuator is described which uses an absolute (unambiguous) electronic digital readout of displacement in inches in addition to the usual gear driven mechanical counter-dial readout in decibels. The attenuator is rack-mountable and has the input and output RF connectors in a fixed position. The attenuation rate for 55, 50, and 30 MHz operation is given along with a discussion of sources of errors. In addition, information is included to aid the user in making adjustments on the attenuator should it be damaged or disassembled for any reason.

Cook, C. C.↗

Analysis of Skylab/Apollo Telescope Mount S-056 observations based on a force-free magnetic field model

Data obtained from the S-056 X-ray experiment on Skylab/ATM have been analyzed based on the assumption that the magnetic fields in the chromosphere and lower corona are force-free. Underlying the analysis is the hypothesis that the observed X-ray filaments coincide with magnetic field lines. The photographic recording of the filaments can then be compared with the projection along the line of sight of the computed magnetic field lines of the model. Ground-based observations of the longitudinal magnetic field component complement the X-ray data and are used in the theoretical interpretation.

Meyer, R. X.↗

Solar prominences in the extreme ultraviolet as observed from the Apollo Telescope Mount

Observations of quiescent solar prominences with the Harvard College Observatory spectrometer aboard Skylab show that prominence material is optically thick in the Lyman alpha line and the Lyman continuum. The color temperature of the Lyman continuum has a mean of 6600 K and an upward gradient toward the top of the prominence. The departure coefficient of the ground state of hydrogen is found to be of the order of unity, as expected from theory. The optical depth of the C III sheath region is determined directly from the observation of the limb through the prominence and is used to infer the mean electron density and the temperature gradient of the sheath. The result implies that the sheath density is about 0.4, and the temperature gradient about 1.4 times the respective value in the C III transition zone of the quiet sun. The C III triplet-singlet ratio for the prominence is found to give a density compatible, within the uncertainty of the atomic parameters, with the density obtained from the optical depth.

Schmahl, E. J.↗

Radiation from a homogeneous sphere mounted on a waveguide aperture

The results of an experimental and theoretical study of the effects of placing a dielectric sphere over the aperture of a circular waveguide are presented. A dielectric sphere excited by a Huygens' source is used as the theoretical model to interpret the experimental results. Calculations based on this model show good overall agreement with experimental patterns and directivity measurements. It is concluded that dielectric loaded antennas such as the dielectric sphere excited by a waveguide can produce directivities in excess of that obtained by a uniformly illuminated aperture of the same cross section, particularly for dielectric objects with dimensions of two wavelengths or less. Measurements of the coupling between these antennas show that they, in general, are not as closely coupled as plain apertures without dielectric object loading.

Croswell, W. F.↗

Surface mounted flat-conductor cable

Report presents drawbacks and advantages of FCC for home wiring. Two types of surface-wiring schemes are considered: snap-on baseboard and extendable baseboard. Both types lower installation cost and time.

Hankins, J. D.↗

Application of rotor mounted pressure transducers to analysis of inlet turbulence

Miniature pressure transducers installed near the leading edge of a fan blade were used to diagnose the non-uniform flow entering a subsonic tip speed turbofan on a static test stand. The pressure response of the blade to the inlet flow variations was plotted in a form which shows the space-time history of disturbances ingested by the rotor. Also, periodically sampled data values were auto- and cross-correlated as if they had been acquired from fixed hot wire anemometers at 150 equally spaced angles around the inlet. With a clean inlet and low wind, evidence of long, narrow turbulence eddies was easily found both in the boundary layer of the fan duct and outside the boundary layer. The role of the boundary layer was to follow and amplify disturbances in the outer flow. These eddies frequently moved around the inlet with a corkscrew motion as they passed through.

Hanson, D. B.↗

A design approach and selected wind tunnel results at high subsonic speeds for wing-tip mounted winglets

Winglets, which are small, nearly vertical, winglike surfaces, substantially reduce drag coefficients at lifting conditions. The primary winglet surfaces are rearward above the wing tips; secondary surfaces are forward below the wing tips. This report presents a discussion of the considerations involved in the design of the winglets; measured effects of these surfaces on the aerodynamic forces, moments, and loads for a representative first generation, narrow body jet transport wing; and a comparison of these effects with those for a wing tip extension which results in approximately the same increase in bending moment at the wing-fuselage juncture as did the addition of the winglets.

Whitcomb, R. T.↗

Flush-mounted hot-wire gage for skin friction and separation detection measurements

A heated-element skin-friction gage employing a very low thermal-conductivity support is described. It is shown that the effective dimension of the gage in the stream direction is only 0.06 mm, including the effects of heat conduction in the supporting material. Because of its small size, the calibration of the gage is independent of the kind of boundary-layer flow (whether laminar or turbulent) and is insensitive to pressure gradients. Construction tolerances can be maintained so that a single universal calibration can be applied. Multiple gages, sufficiently closely spaced so as to interfere with each other, are shown to provide accurate determinations of the location of the points of boundary-layer separation and reattachment.

Rubesin, M. W.↗

Window-mounted auxiliary solar heater

System uses hot-air collectors, no thermal storage, and fan with thermostat switches. At cost of heating efficiency, unit could be manufactured and sold at price allowing immediate entry to market as auxiliary heating system. Its simplicity allows homeowner installation, and maintenance is minimal.

Anthony, K. G.↗

Vacuum mounting for piezoelectric transducers

Special housing couples piezoelectric transducers to nonporous surfaces for ultrasonic or acoustic-emission testing. Device, while providing sound isolation on flat or nonflat surfaces, can be attached and detached quickly. Vacuum sealing mechanism eliminates need for permanent or semipermanent bonds, viscous coupling liquids, weights, magnets, tape, or springs ordinarily used.

Tiede, D. A.↗

The Mount Wilson solar magnetograph - Scanning and data system

The paper describes a computer-operated image-scanning and data-collection system for the magnetograph at the Mt. Wilson 150-foot Tower telescope. The system is based on a minicomputer with a 32K word core memory and a generalized interface unit for controlling image motion, a keyboard, and an associated television screen. Operation of the solar image guider and the data-collection assembly is outlined along with the observation and data-reduction procedures. Advantages of the system include the ability to move the image in almost any conceivable fashion, a wide choice of integration times, and increased accuracy in magnetic and Doppler calibrations as well as in setting of the magnetic zero level.

Howard, R.↗

Extreme UV spectroheliometer on the Apollo Telescope Mount

The extreme UV spectroheliometer flown on ATM observed within the 280-1340 A spectral range at seven wavelengths simultaneously, with a spatial resolution element 5 x 5 sq arcsec field of view in 5.5 min. The instrument could also obtain spectral scans over the same wavelength range with a spectral resolution of 1.6 A in 3.8 min. The instrument is described in detail with attention given to the telescope, the spectrometer, and the detection system.

Reeves, E. M.↗

Optical contamination - Its prevention in the XUV spectrographs flown by the U.S. Naval Research Laboratory in the Apollo Telescope Mount

During construction and testing of the XUV spectrographs flown in the ATM by the Naval Research Laboratory, many problems associated with optical contamination were encountered. Solving these problems required setting up a contamination prevention program to select the materials used in constructing the instruments and to delineate procedures in assembling, testing, and storing the instruments. A brief description is given of methods of assessing the effects of contamination and of the procedures used to prevent contamination.

Hunter, W. R.↗

Reliability analysis of forty-five strain-gage systems mounted on the first fan stage of a YF-100 engine

The reliability of 45 state-of-the-art strain gage systems under full scale engine testing was investigated. The flame spray process was used to install 23 systems on the first fan rotor of a YF-100 engine; the others were epoxy cemented. A total of 56 percent of the systems failed in 11 hours of engine operation. Flame spray system failures were primarily due to high gage resistance, probably caused by high stress levels. Epoxy system failures were principally erosion failures, but only on the concave side of the blade. Lead-wire failures between the blade-to-disk jump and the control room could not be analyzed.

Holanda, R.↗

Stiffness and damping of elastomeric O-ring bearing mounts

A test rig to measure the dynamic stiffness and damping of elastomer O rings was described. Test results for stiffness and loss coefficient in the frequency range from 50 Hz to 1000 Hz are presented. Results are given for three different materials, for five temperatures, for three amplitudes, for five values of squeeze for three values of stretch for three values of cross-section diameter and for three values of groove width. All test data points were plotted. In addition, trend summary plots were presented which compare the effect of material, temperature, amplitude, squeeze, stretch, cross-section diameter, and groove width. O ring deflections under a static load for different material were presented; and effective static stiffness values were compared with dynamic values.

Smalley, A. J.↗