Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Space Launch System Launch Window and Day of Launch Processes

Lunar missions benefit from varying the launch azimuth as a function of launch time to allow longer launch windows with minimum performance impacts. This variable azimuth approach allows the vehicle to track the Moon’s apparent motion due to Earth’s rotation . The Space Launch System (SLS) Block 1 vehicle design requires the mission to launch into an elliptical parking orbit to provide sufficient energy to insert Orion into a trans-lunar trajectory. The primary benefit of varying the launch azimuth, and as a result the parking orbit inclination, allows the SLS Interim Cryogenic Propulsion Stage (ICPS) to perform its Trans-Lunar Injection (TLI) burn closer to perigee and take advantage of performing a burn in a location where the burn will primarily raise apogee.

A. S. Craig↗

Space Launch System Launch Windows and Day of Launch Processes

Lunar missions benefit from varying the launch azimuth as a function of launch time to allow longer launch windows with minimum performance impacts. This variable azimuth approach allows the vehicle to track the Moon’s apparent motion due to Earth’s rotation. The Space Launch System (SLS) Block 1 vehicle design requires the mission to launch into an elliptical parking orbit to provide sufficient energy to insert Orion into a Trans-Lunar Injection (TLI) orbit. The primary benefit of varying the launch azimuth, and as a result the achieved orbit inclination, allows the SLS Interim Cryogenic Propulsion Stage (ICPS) to perform its TLI burn closer to perigee and take advantage of performing a burn in a location where the burn will optimally raise apogee.

launch window↗

Characterizing the GD-1 Stream with DESI DR2 Data: Thin Stream and Hot Cocoon

GD-1 is among the longest, coldest stellar streams in the Milky Way, making it an ideal target for probing dark matter substructure through dynamical heating. We present a catalog of 608 spectroscopically confirmed GD-1 members from the first three years of Dark Energy Spectroscopic Instrument (DESI) observations. This constitutes the largest homogeneous spectroscopic sample of GD-1, doubling the number of members previously available only through heterogeneous compilations combining multiple surveys with different systematics. Using these data, we derive updated stream tracks in sky position, proper motion, and radial velocity that extend over $100^\circ$ of the stream. We apply a Gaussian mixture model to decompose the stream into a dynamically cold thin component ($σ_V = 2.49\pm 0.28$ km s$^{-1}$, width $= 0.23\pm0.01^\circ$) and a kinematically hot cocoon ($σ_V = 6.13\pm0.75$ km s$^{-1}$, width $= 2.18\pm0.17^\circ$). The cocoon contains $\sim30\%$ of members and its velocity dispersion is consistent with $\sim11$ Gyr of heating by cold dark matter subhalos. We also detect a large proper motion dispersion ($41.36\pm4.98$ km s$^{-1}$) along the stream direction in the cocoon component. This feature indicates a significant line-of-sight distance spread in the cocoon, and its origin will be further explored in a forthcoming paper. These measurements demonstrate the power of DESI spectroscopy for characterizing the multi-component phase-space structure of stellar streams and constraining small-scale dark matter substructure.

Jarvis, Emma [Toronto U.] (ORCID:0009000656127336)↗

SU-G-JeP4-12: Real-Time Organ Motion Monitoring Using Ultrasound and KV Fluoroscopy During Lung SBRT Delivery

Purpose: Real-time ultrasound monitoring during SBRT is advantageous in understanding and identifying motion irregularities which may cause geometric misses. In this work, we propose to utilize real-time ultrasound to track the diaphragm in conjunction with periodical kV fluoroscopy to monitor motion of tumor or landmarks during SBRT delivery. Methods: Transabdominal Ultrasound (TAUS) b-mode images were collected from 10 healthy volunteers using the Clarity Autoscan System (Elekta). The autoscan transducer, which has a center frequency of 5 MHz, was utilized for the scans. The acquired images were contoured using the Clarity Automatic Fusion and Contouring workstation software. Monitoring sessions of 5 minute length were observed and recorded. The position correlation between tumor and diaphragm could be established with periodic kV fluoroscopy periodically acquired during treatment with Elekta XVI. We acquired data using a tissue mimicking ultrasound phantom with embedded spheres placed on a motion stand using ultrasound and kV Fluoroscopy. MIM software was utilized for image fusion. Correlation of diaphragm and target motion was also validated using 4D-MRI and 4D-CBCT. Results: The diaphragm was visualized as a hyperechoic region on the TAUS b-mode images. Volunteer set-up can be adjusted such that TAUS probe will not interfere with treatment beams. A segment of the diaphragm was contoured and selected as our tracking structure. Successful monitoring sessions of the diaphragm were recorded. For some volunteers, diaphragm motion over 2 times larger than the initial motion has been observed during tracking. For the phantom study, we were able to register the 2D kV Fluoroscopy with the US images for position comparison. Conclusion: We demonstrated the feasibility of tracking the diaphragm using real-time ultrasound. Real-time tracking can help in identifying such irregularities in the respiratory motion which is correlated to tumor motion. We also showed the feasibility of acquiring 2D KV Fluoroscopy and registering the images with Ultrasound.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting multiple moving objects in crowded environments with coherent motion regions

Coherent motion regions extend in time as well as space, enforcing consistency in detected objects over long time periods and making the algorithm robust to noisy or short point tracks. As a result of enforcing the constraint that selected coherent motion regions contain disjoint sets of tracks defined in a three-dimensional space including a time dimension. An algorithm operates directly on raw, unconditioned low-level feature point tracks, and minimizes a global measure of the coherent motion regions. At least one discrete moving object is identified in a time series of video images based on the trajectory similarity factors, which is a measure of a maximum distance between a pair of feature point tracks.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-182: Reproducibility of Tumor Motion Probability Distribution Function in Stereotactic Body Radiation Therapy of Lung Using Real-Time Tumor-Tracking Radiotherapy System

Purpose: We aim to achieve new four-dimensional radiotherapy (4DRT) using the next generation real-time tumor-tracking (RTRT) system and flattening-filter-free techniques. To achieve new 4DRT, it is necessary to understand the respiratory motion of tumor. The purposes of this study were: 1.To develop the respiratory motion analysis tool using log files. 2.To evaluate the reproducibility of tumor motion probability distribution function (PDF) during stereotactic body RT (SBRT) of lung tumor. Methods: Seven patients having fiducial markers closely implanted to the lung tumor were enrolled in this study. The positions of fiducial markers were measured using the RTRT system (Mitsubishi Electronics Co., JP) and recorded as two types of log files during the course of SBRT. For each patients, tumor motion range and tumor motion PDFs in left-right (LR), anterior-posterior (AP) and superior-inferior (SI) directions were calculated using log files of all beams per fraction (PDFn). Fractional PDF reproducibility (Rn) was calculated as Kullback-Leibler (KL) divergence between PDF1 and PDFn of tumor motion. The mean of Rn (Rm) was calculated for each patient and correlated to the patient’s mean tumor motion range (Am). The change of Rm during the course of SBRT was also evluated. These analyses were performed using in-house developed software. Results: The Rm were 0.19 (0.07–0.30), 0.14 (0.07–0.32) and 0.16 (0.09–0.28) in LR, AP and SI directions, respectively. The Am were 5.11 mm (2.58–9.99 mm), 7.81 mm (2.87–15.57 mm) and 11.26 mm (3.80–21.27 mm) in LR, AP and SI directions, respectively. The PDF reproducibility decreased as the tumor motion range increased in AP and SI direction. That decreased slightly through the course of RT in SI direction. Conclusion: We developed the respiratory motion analysis tool for 4DRT using log files and quantified the range and reproducibility of respiratory motion for lung tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Dose Caffeine Administration During Acute Sleep Deprivation Eliminates Visual Motion Processing Impairment, but Does Not Improve Saccadic Rate

Oculomotor tracking performance changes according to time awake. A constant routine (CR) study demonstrated that increasing time awake 1) reduces the precision of visual motion processing, 2) decreases steady-state closed-loop pursuit performance and 3) decreases peak saccadic velocity. We aimed to determine the contribution of homeostatic sleep pressure on these oculometric changes by administering low-dose caffeine over one night of sleep deprivation. Participants completed two weeks of at-home 8.5 hours sleep per day, followed by an approximately 24-hour laboratory CR in semi-recumbent posture under less than 4 lux of light. The visual tracking task was performed every two hours after waking and hourly overnight. Low-dose caffeine of 0.3 milligrams per kilogram was administered hourly during the biological night. Nine participants (5F) completed the study. Caffeine dosing: 1) prevented the impairment of visual motion processing, 2) reduced by approximately half the impairment of closed-loop pursuit performance (gain, minus 0.47 percent per hour, significance of slope change: p (probability) less than 0.006; proportion smooth, minus 0.35 percent per hour, p less than 0.005), and 3) had an insignificant (p less than 0.39) effect on the impairment of saccadic peak velocity (slope, minus 1.13 percent per hour; intercept, minus 0.62 percent per hour). These results suggest that visual motion processing and some proportion of closed-loop pursuit performance are impaired due to homeostatic mechanisms during sleep deprivation.

Sleep↗

Oculometric Analysis of Saccadic Compensation for Visual Motion Processing Impairment due to Alcohol and Sleep Disruption

The Visuomotor Control Laboratory at Ames Research Center has developed a 5-minute ocular tracking test that computes 21 largely independent metrics of visuomotor performance, reflecting neural signal processing along a number of distinct pathways through cortex, brainstem, and cerebellum. Human sensorimotor performance is resilient to the challenges and stressors of many operational environments, in part, because overall performance is achieved through multiple parallel systems. Our multidimensional oculometrics allow us to examine impacts on these sub-components separately. To illustrate this, we contrasted the effects of two mild neural stressors, acute sleep-deprivation and low-dose alcohol. We have previously shown that, in both cases, oculometric analysis is a highly sensitive indicator of impairment. Here we quantified not only the observed impact on the performance of one sub-system, smooth pursuit, which uses high-level cortical processing of visual motion to track a moving object, but also the observed (partial) compensation by an evolutionarily older mid-brain and brainstem subsystem, saccades, which generates jumps in eye position to catch up with the target when smooth pursuit is inadequate. Specifically, we examined the dose-response (effect size vs. dose size) of the ground lost (pursuit deficit) and the ground recouped (saccadic compensation) across three separate studies – acute low-dose alcohol administration (16 subjects), acute sleep loss (12 subjects), and acute sleep loss with caffeine intervention (9 subjects). We computed the dose-response slopes using linear regression. The figure below shows that, in the case of acute sleep deprivation, the resulting slopes for ground lost and ground recouped (mean ± SE across subjects) were significantly different (paired t-test, t(11) = 5.17, p < 0.001), indicating poor saccadic compensation. However, when sleep loss was coupled with caffeine ingestion, ground lost was decreased and ground recouped increased such that the slopes were no longer different (t(8) = -0.05, p = 0.965). With alcohol, the two slopes were large albeit not significantly different (t(15) = 0.96, p = 0.351), indicating significant pursuit impairment but effective saccadic compensation. Our findings show that sleep deprivation and alcohol affect oculomotor performance differently. Low-dose alcohol effects appear predominantly cortical, with effective brainstem compensation. Sleep loss and circadian disruption however appears to affect both cortical and brainstem pathways with caffeine providing an effective countermeasure to both effects. Beyond the mere detection of impairment, our oculometric assessment allows us to characterize the nature of the deficit, to provide insight into the neural substrate, and to assess the effectiveness of countermeasures.

pursuit↗

Spherical Coordinate Systems for Streamlining Suited Mobility Analysis

Introduction: When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. It has been shown that using a spherical coordinate system allows Anthropometry and Biomechanics Facility (ABF) personnel to increase their ability to transmit important human mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project was to use innovative analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub‐projects, meant to validate and verify a new method before it was implemented in the ABF's data analysis practices. A mechanical test rig was built and tracked in 3D using an optical motion capture system. Its position and orientation were reported in both Euler and spherical reference systems. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder to include the rest of the joints of the body. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. These visualization methods will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development. Results: Initial results demonstrated that a spherical coordinate system is helpful in describing and visualizing the motion of a space suit. The system is particularly useful in describing the motion of the shoulder, where multiple degrees of freedom can lead to very complex motion paths.

Benson, Elizabeth↗

Electromagnetic Real-Time Tumor Position Monitoring and Dynamic Multileaf Collimator Tracking Using a Siemens 160 MLC: Geometric and Dosimetric Accuracy of an Integrated System

Purpose: Dynamic multileaf collimator tracking represents a promising method for high-precision radiotherapy to moving tumors. In the present study, we report on the integration of electromagnetic real-time tumor position monitoring into a multileaf collimator-based tracking system. Methods and Materials: The integrated system was characterized in terms of its geometric and radiologic accuracy. The former was assessed from portal images acquired during radiation delivery to a phantom in tracking mode. The tracking errors were calculated from the positions of the tracking field and of the phantom as extracted from the portal images. Radiologic accuracy was evaluated from film dosimetry performed for conformal and intensity-modulated radiotherapy applied to different phantoms moving on sinusoidal trajectories. A static radiation delivery to the nonmoving target served as a reference for the delivery to the moving phantom with and without tracking applied. Results: Submillimeter tracking accuracy was observed for two-dimensional target motion despite the relatively large system latency of 500 ms. Film dosimetry yielded almost complete recovery of a circular dose distribution with tracking in two dimensions applied: 2%/2 mm gamma-failure rates could be reduced from 59.7% to 3.3%. For single-beam intensity-modulated radiotherapy delivery, accuracy was limited by the finite leaf width. A 2%/2 mm gamma-failure rate of 15.6% remained with tracking applied. Conclusion: The integrated system we have presented marks a major step toward the clinical implementation of high-precision dynamic multileaf collimator tracking. However, several challenges such as irregular motion traces or a thorough quality assurance still need to be addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From following edges to pursuing objects

Primates can generate accurate, smooth eye-movement responses to moving target objects of arbitrary shape and size, even in the presence of complex backgrounds and/or the extraneous motion of non-target objects. Most previous studies of pursuit have simply used a spot moving over a featureless background as the target and have thus neglected critical issues associated with the general problem of recovering object motion. Visual psychophysicists and theoreticians have shown that, for arbitrary objects with multiple features at multiple orientations, object-motion estimation for perception is a complex, multi-staged, time-consuming process. To examine the temporal evolution of the motion signal driving pursuit, we recorded the tracking eye movements of human observers to moving line-figure diamonds. We found that pursuit is initially biased in the direction of the vector average of the motions of the diamond's line segments and gradually converges to the true object-motion direction with a time constant of approximately 90 ms. Furthermore, transient blanking of the target during steady-state pursuit induces a decrease in tracking speed, which, unlike pursuit initiation, is subsequently corrected without an initial direction bias. These results are inconsistent with current models in which pursuit is driven by retinal-slip error correction. They demonstrate that pursuit models must be revised to include a more complete visual afferent pathway, which computes, and to some extent latches on to, an accurate estimate of object direction over the first hundred milliseconds or so of motion.

NASA Discipline Neuroscience↗

SU-E-J-194: Dynamic Tumor Tracking End-To-End Testing Using a 4D Thorax Phantom and EBT3 Films

Purpose: To quantify the Vero linac dosimetric accuracy of the tumor dynamic tracking treatment using EBT3 film embedded in a 4D thorax phantom. Methods: A dynamic thorax phantom with tissue equivalent materials and a film insert were used in this study. The thorax phantom was scanned in 4DCT mode with a viscoil embedded in its film insert composed of lung equivalent material. Dynamic tracking planning was performed using the 50% phase CT set with 5 conformal beams at gantry angles of 330, 15, 60, 105 and 150 degrees. Each field is a 3cm by 3cm square centered at viscoil since there was no solid mass target. Total 3 different 1–2cos4 motion profiles were used with varied motion magnitude and cycle frequency. Before treatment plan irradiation, a 4D motion model of the target was established using a series of acquired fluoroscopic images and infrared markers motion positions. During irradiation, fluoroscopic image monitoring viscoil motion was performed to verify model validity. The irradiated films were scanned and the dose maps were compared to the planned Monte Carlo dose distributions. Gamma analyses using 3%–3mm, 2%–3mm, 3%–2mm, 2%–2mm criteria were performed and presented. Results: For each motion pattern, a 4D motion model was built successfully and the target tracking performance was verified with fluoroscopic monitoring of the viscoil motion and its model predicted locations. The film gamma analysis showed the average pass rates among the 3 motion profiles are 98.14%, 96.2%, 91.3% and 85.61% for 3%–3mm, 2%–3mm, 3%–2mm, 2%–2mm criteria. Conclusion: Target dynamic tracking was performed using patient-like breathing patterns in a 4D thorax phantom with EBT3 film insert and a viscoil. There was excellent agreement between acquired and planned dose distributions for all three target motion patterns. This study performed end-to-end testing and verified the treatment accuracy of tumor dynamic tracking.

60 APPLIED LIFE SCIENCES↗

Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method

The authors present a segment-based convolution method to account for the interplay effect between intrafraction organ motion and the multileaf collimator position for each particular segment in intensity modulated radiation therapy (IMRT) delivered in a step-and-shoot manner. In this method, the static dose distribution attributed to each segment is convolved with the probability density function (PDF) of motion during delivery of the segment, whereas in the conventional convolution method (''average-based convolution''), the static dose distribution is convolved with the PDF averaged over an entire fraction, an entire treatment course, or even an entire patient population. In the case of IMRT delivered in a step-and-shoot manner, the average-based convolution method assumes that in each segment the target volume experiences the same motion pattern (PDF) as that of population. In the segment-based convolution method, the dose during each segment is calculated by convolving the static dose with the motion PDF specific to that segment, allowing both intrafraction motion and the interplay effect to be accounted for in the dose calculation. Intrafraction prostate motion data from a population of 35 patients tracked using the Calypso system (Calypso Medical Technologies, Inc., Seattle, WA) was used to generate motion PDFs. These were then convolved with dose distributions from clinical prostate IMRT plans. For a single segment with a small number of monitor units, the interplay effect introduced errors of up to 25.9% in the mean CTV dose compared against the planned dose evaluated by using the PDF of the entire fraction. In contrast, the interplay effect reduced the minimum CTV dose by 4.4%, and the CTV generalized equivalent uniform dose by 1.3%, in single fraction plans. For entire treatment courses delivered in either a hypofractionated (five fractions) or conventional (>30 fractions) regimen, the discrepancy in total dose due to interplay effect was negligible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visual/motion cue mismatch during a coordinated roll maneuver

The effect of a performance mismatch between the simulator visual and motion display systems on pilot performance while engaged in a compensatory tracking task, and the effect of a reduction in simulator motion scaling while maintaining constant visual scaling on pilot performance for this same task were investigated. A jet transport aircraft with motion in the roll and lateral simulator axes was used as a test vehicle for a computer simulation. The aircraft was disturbed by moderate levels of turbulence which resulted in flight path deviations in the roll and lateral axes. The task of the pilot was to maintain flight formation behind the aircraft in front of him as displayed by a video monitor located in the simulator cockpit. Experimental data consisting of pilot describing functions and pilot performance scores are presented and discussed as they relate to experimental evidence.

Shirachi, D. K.↗

Optimal detumbling of a large manned spacecraft using an internal moving mass

The use of a movable mass control system to stabilize an arbitrarily tumbling asymmetric vehicle about the maximum inertia axis is considered. A first-order gradient optimization technique is used to minimize angular velocity components along the intermediate and minimum inertia axes. This method permits a wide range of initial guesses for mass position history. Motion of the control mass is along a linear track fixed in the vehicle. The control variable is taken as mass acceleration with respect to body coordinates. Motion is limited to defined quantities and a penalty function is used to insure a given range of positions. Numerical solutions of the optimization equations verify that minimum time detumbling is achieved with the largest permissible movable mass, length of linear track, and positions of the mass on the two coordinates perpendicular to the linear motion.

Kunciw, B. G.↗

Optimal detumbling of a large manned spacecraft using an internal moving mass

This investigation deals with the use of a movable mass control system to stabilize a tumbling asymmetric spacecraft about the maximum inertia axis. A first-order gradient optimization technique is used to minimize angular velocity components along the intermediate and minimum inertia axes, thus, permitting a wide range of initial guesses for mass position history. Motion of the control mass is along a linear track fixed in the vehicle. The control variable is taken as mass acceleration with respect to body coordinates. Motion is limited to defined quantities and a penalty function is used to insure a given range of positions. Numerical solutions of the optimization equations verify that minimum time detumbling is achieved with the largest permissible movable mass, length of linear track, and positions of the mass on the two coordinates perpendicular to the linear motion. The optimal method permits detumbling in about one-fourth the time when compared to a force control law formulation available in the literature.

Kunciw, B. G.↗

3D tracking of particles in a dusty plasma by laser sheet tomography

The collective behavior of levitated particles in a weakly ionized plasma (dusty plasma) has raised significant scientific interest. This is due to the complex array of forces acting on the particles and their potential to act as in situ diagnostics of the plasma environment. Ideally, the three-dimensional (3D) motion of many particles should be tracked for long periods of time. Typically, stereoscopic imaging using multiple cameras combined with particle image velocimetry is used to obtain a velocity field of many particles, yet this method is limited by its sample volume and short time scales. Here, we demonstrate a different, high-speed tomographic imaging method capable of tracking individual particles. We use a scanning laser sheet coupled to a single high-speed camera. We are able to identify and track tens of individual particles over centimeter length scales for several minutes, corresponding to more than 10 000 frames.

Physics↗

Spinning Rocket Simulator Turntable Design

Contained herein is the research and data acquired from the Turntable Design portion of the Spinning Rocket Simulator (SRS) project. The SRS Project studies and eliminates the effect of coning on thrust-propelled spacecraft. This design and construction of the turntable adds a structural support for the SRS model and two degrees of freedom. The two degrees of freedom, radial and circumferential, will help develop a simulated thrust force perpendicular to the plane of the spacecraft model while undergoing an unstable coning motion. The Turntable consists of a ten-foot linear track mounted to a sprocket and press-fit to a thrust bearing. A two-inch high column grounded by a Triangular Baseplate supports this bearing and houses the slip rings and pressurized, air-line swivel. The thrust bearing allows the entire system to rotate under the moment applied through the chain-driven sprocket producing a circumferential degree of freedom. The radial degree of freedom is given to the model through the helically threaded linear track. This track allows the Model Support and Counter Balance to simultaneously reposition according to the coning motion of the Model. Two design factors that hinder the linear track are bending and twist due to torsion. A Standard Aluminum "C" channel significantly reduces these two deflections. Safety considerations dictate the design of all the components involved in this project.

Miles, Robert W.↗