Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Correlations Between Fission Fragment and Neutron Anisotropies in Neutron-Induced Fission

Several sources of angular anisotropy for fission fragments and prompt neutrons have been studied in neutron-induced fission reactions. These include kinematic recoils of the target from the incident neutron beam and the fragments from the emission of the prompt neutrons, preferential directions of the emission of the fission fragments with respect to the beam axis due to the population of particular transition states at the fission barrier, and forward-peaked angular distributions of pre-equilibrium neutrons which are emitted before the formation of a compound nucleus. In addition, there are several potential sources of angular anisotropies that are more difficult to disentangle: the angular distributions of prompt neutrons from fully accelerated fragments or from scission neutrons, and the emission of neutrons from fission fragments that are not fully accelerated. Here, we study the effects of the first group of anisotropy sources, particularly exploring the correlations between the fission-fragment anisotropy and the resulting neutron anisotropy. While kinematic effects were already accounted for in our Hauser-Feshbach Monte Carlo code cgmf, anisotropic angular distributions for the fission fragments and pre-equilibrium neutrons resulting from neutron-induced fission on 233,234,235,238 U, 239,241 Pu, and 237 Np have been introduced for the first time. The effects of these sources of anisotropy are examined over a range of incident neutron energies, from thermal to 20 MeV, and compared with experimental data from the Chi-Nu liquid scintillator array. The anisotropy of the fission fragments is reflected in the anisotropy of the prompt neutrons, especially as the outgoing energy of the prompt neutrons increases, allowing for an extraction of the fission-fragment anisotropy to be made from a measurement of the neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

JETSCAPE framework: p+p results

The JETSCAPE framework is a modular and versatile Monte Carlo software package for the simulation of high energy nuclear collisions. In this work we present a new tune of JETSCAPE, called PP19, and validate it by comparison to jet-based measurements in p + p collisions, including inclusive single jet cross sections, jet shape observables, fragmentation functions, charged hadron cross sections, and dijet mass cross sections. These observables in p+p collisions provide the baseline for their counterparts in nuclear collisions. Quantifying the level of agreement of JETSCAPE results with p+p data is thus necessary for meaningful applications of JETSCAPE to A+A collisions. The calculations use the JETSCAPE PP19 tune, defined in this paper, based on version 1.0 of the JETSCAPE framework. For the observables discussed in this work calculations using JETSCAPE PP19 agree with data over a wide range of collision energies at a level comparable to standard Monte Carlo codes. These results demonstrate the physics capabilities of the JETSCAPE framework and provide benchmarks for JETSCAPE users.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and validation of a fission-product source for radioactive beams

A neutron-generator-based source of fission products (nuCARIBU) is being developed to replace the existing source at Argonne National Laboratory. Neutrons generated by reaction are thermalized in a compact polyethylene [(moderator and impinge on a thin 235 U foil to produce fission products. Experiments have been conducted to verify the nuCARIBU concept and simulation results using a 4 MeV, 0.16 µ⁢A proton beam from the ATLAS accelerator irradiating a LiF neutron production target and two different simplified versions of the nuCARIBU (C 2 ⁢H 4 ) n moderator with thicknesses of 3.81 cm and 1.91 cm separating it from the enriched 235 U fission foil. Here, the emitted γ-ray peaks of 1383.93 keV ( 92 Sr), 358.0 keV ( 104 Tc), 565.992 keV ( 134 Te), and 258.411 keV ( 138 Xe) obtained from fission products are used to determine the neutron-induced fission rates in the fission foil. The measured fission rates are in good agreement with those simulated using the PHITS Monte Carlo code with user-defined neutron production cross sections based on well-known cross section data. These experimental results, consistent with the simulations, show that the current 252 Cf source (CARIBU) can be replaced by the neutron induced fission source (nuCARIBU).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Triphoton production at hadron colliders

We present next-to-leading order predictions for the production of triphoton final states at the LHC and the Tevatron. Our results include the effect of photon fragmentation for the first time and we are able to quantify the impact of different isolation prescriptions. We find that calculations accounting for fragmentation effects at leading order, and those employing a smooth cone isolation where no fragmentation contribution is required, are in reasonable agreement with one another. However, larger differences in the predicted rates arise when higher order corrections to the fragmentation functions are included. In addition we present full analytic results for the $\gamma\gamma\gamma$ and $\gamma\gamma+$jet one-loop amplitudes. These amplitudes, which are particularly compact, may be useful to future higher-order calculations. Our results are available in the Monte Carlo code MCFM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of multicomponent relativistic thermalization

Multicomponent relativistic fluids have been studied for decades. However, simulating the dynamics of the particles and fluids in such a mixture has been a challenge due to the fact that such simulations are computationally expensive in three spatial dimensions. Here, we report on the development and application of a multidimensional relativistic Monte Carlo code to explore the thermalization process in a relativistic multicomponent environment in a computationally inexpensive way. As an illustration we simulate the fully relativistic three-dimensional Brownian-motion-like solution to the thermalization of a high-mass particle (proton) in a bath of relativistic low-mass particles (electrons). Here, we follow the thermalization and ultimate equilibrium distribution of the Brownian-like particle as can happen in the cosmic plasma during big-bang nucleosynthesis. We also simulate the thermalization of energetic particles injected into the plasma as can occur, for example, by the decay of massive unstable particles during the big bang.

79 ASTRONOMY AND ASTROPHYSICS↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion beam sputtering of silicon: Energy distributions of sputtered and scattered ions

The properties of sputtered and scattered ions are studied for ion beam sputtering of Si by bombardment with noble gas ions. The energy distributions in dependence on ion beam parameters (ion energy: 0.5-1 keV; ion species: Ne, Ar, Xe) and geometrical parameters (ion incidence angle, polar emission angle, and scattering angle) are measured by means of energy-selective mass spectrometry. The presence of anisotropic effects due to direct sputtering and scattering is discussed and correlated with process parameters. The experimental results are compared to calculations based on a simple elastic binary collision model and to simulations using the Monte-Carlo code SDTRIMSP . The influence of the contribution of implanted primary ions on energy distributions of sputtered and scattered particles is studied in simulations. It is found that a 10% variation of the target composition leads to detectable but small differences in the energy distributions of scattered ions. Comparison with previously reported data for other ion/target configurations confirms the presence of similar trends and anisotropic effects: The number of high-energy sputtered ions increases with increasing energy of incident ions and decreasing scattering angle. The effect of the ion/target mass ratio is additionally investigated. Small differences are observed with the change of the primary ion species: The closer the mass ratio to unity, the higher the average energy of sputtered ions. Finally, the presence of peaks, assigned to different mechanisms of direct scattering, strongly depends on the ion/target mass ratio.

42 ENGINEERING↗

The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields

Purpose: The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Methods: Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a {sup 60}Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes FLUKA and MCNP. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen and Olsen alanine response model. Results: The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. Conclusions: The alanine detector can be used without difficulty in neutron fields. The response has been understood with the model used which includes the relative effectiveness. Results and the corresponding discussion lead to the conclusion that application in neutron fields for medical purpose is limited by its sensitivity but that it is a useful tool as supplement to other detectors and verification of neutron source descriptions.

07 ISOTOPE AND RADIATION SOURCES↗

HDR {sup 192}Ir source speed measurements using a high speed video camera

Purpose: The dose delivered with a HDR {sup 192}Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a {sup 192}Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases.

07 ISOTOPE AND RADIATION SOURCES↗

Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes

Purpose: This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. Methods: Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scattered photons at the maze entrance. The dose of the backscattered photons from a concrete wall was measured for various scattering angles. The dose was also calculated by the FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. Results: It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscattered photons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. Conclusions: This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR {sup 192}Ir source: TLD-100™, Gafchromic{sup ®} EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros™ algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision™, Acuros™, and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. Conclusions: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros™ algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms.

07 ISOTOPE AND RADIATION SOURCES↗

Breast dose in mammography is about 30% lower when realistic heterogeneous glandular distributions are considered

Purpose: Current dosimetry methods in mammography assume that the breast is comprised of a homogeneous mixture of glandular and adipose tissues. Three-dimensional (3D) dedicated breast CT (bCT) data sets were used previously to assess the complex anatomical structure within the breast, characterizing the statistical distribution of glandular tissue in the breast. The purpose of this work was to investigate the effect of bCT-derived heterogeneous glandular distributions on dosimetry in mammography. Methods: bCT-derived breast diameters, volumes, and 3D fibroglandular distributions were used to design realistic compressed breast models comprised of heterogeneous distributions of glandular tissue. The bCT-derived glandular distributions were fit to biGaussian functions and used as probability density maps to assign the density distributions within compressed breast models. The MCNPX 2.6.0 Monte Carlo code was used to estimate monoenergetic normalized mean glandular dose “DgN(E)” values in mammography geometry. The DgN(E) values were then weighted by typical mammography x-ray spectra to determine polyenergetic DgN (pDgN) coefficients for heterogeneous (pDgN{sub hetero}) and homogeneous (pDgN{sub homo}) cases. The dependence of estimated pDgN values on phantom size, volumetric glandular fraction (VGF), x-ray technique factors, and location of the heterogeneous glandular distributions was investigated. Results: The pDgN{sub hetero} coefficients were on average 35.3% (SD, 4.1) and 24.2% (SD, 3.0) lower than the pDgN{sub homo} coefficients for the Mo–Mo and W–Rh x-ray spectra, respectively, across all phantom sizes and VGFs when the glandular distributions were centered within the breast phantom in the coronal plane. At constant breast size, increasing VGF from 7.3% to 19.1% lead to a reduction in pDgN{sub hetero} relative to pDgN{sub homo} of 23.6%–27.4% for a W–Rh spectrum. Displacement of the glandular distribution, at a distance equal to 10% of the compressed breast width in the superior and inferior directions, resulted in a 37.3% and a −26.6% change in the pDgN{sub hetero} coefficient, respectively, relative to the centered distribution for the Mo–Mo spectrum. Lateral displacement of the glandular distribution, at a distance equal to 10% of the compressed breast width, resulted in a 1.5% change in the pDgN{sub hetero} coefficient relative to the centered distribution for the W–Rh spectrum. Conclusions: Introducing bCT-derived heterogeneous glandular distributions into mammography phantom design resulted in decreased glandular dose relative to the widely used homogeneous assumption. A homogeneous distribution overestimates the amount of glandular tissue near the entrant surface of the breast, where dose deposition is exponentially higher. While these findings are based on clinically measured distributions of glandular tissue using a large cohort of women, future work is required to improve the classification of glandular distributions based on breast size and overall glandular fraction.

60 APPLIED LIFE SCIENCES↗

Radiative corrections: from medium to high energy experiments

Abstract Radiative corrections are crucial for modern high-precision physics experiments, and are an area of active research in the experimental and theoretical community. Here we provide an overview of the state of the field of radiative corrections with a focus on several topics: lepton–proton scattering, QED corrections in deep-inelastic scattering, and in radiative light-hadron decays. Particular emphasis is placed on the two-photon exchange, believed to be responsible for the proton form-factor discrepancy, and associated Monte-Carlo codes. We encourage the community to continue developing theoretical techniques to treat radiative corrections, and perform experimental tests of these corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision studies of observables in $p p \rightarrow W \rightarrow l\nu _l$ and $ pp \rightarrow \gamma ,Z \rightarrow l^+ l^-$ processes at the LHC

This report was prepared in the context of the LPCC "Electroweak Precision Measurements at the LHC WG" and summarizes the activity of a subgroup dedicated to the systematic comparison of public Monte Carlo codes, which describe the Drell-Yan processes at hadron colliders, in particular at the CERN Large Hadron Collider (LHC). This work represents an important step towards the definition of an accurate simulation framework necessary for very high-precision measurements of electroweak (EW) observables such as the $W$ boson mass and the weak mixing angle. All the codes considered in this report share at least next-to-leading-order (NLO) accuracy in the prediction of the total cross sections in an expansion either in the strong or in the EW coupling constant. The NLO fixed-order predictions have been scrutinized at the technical level, using exactly the same inputs, setup and perturbative accuracy, in order to quantify the level of agreement of different implementations of the same calculation. A dedicated comparison, again at the technical level, of three codes that reach next-to-next-to-leading-order (NNLO) accuracy in quantum chromodynamics (QCD) for the total cross section has also been performed. These fixed-order results are a well-defined reference that allows a classification of the impact of higher-order sets of radiative corrections. Several examples of higher-order effects due to the strong or the EW interaction are discussed in this common framework. Also the combination of QCD and EW corrections is discussed, together with the ambiguities that affect the final result, due to the choice of a specific combination recipe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Challenges and opportunities in verification and validation of low temperature plasma simulations and experiments

This paper describes the verification and validation (V&V) framework developed for the stochastic Particle-in-Cell, Direct Simulation Monte Carlo code Aleph. An ideal framework for V&V from the viewpoint of the authors is described where a physics problem is defined, and relevant physics models and parameters to the defined problem are assessed and captured in a Phenomena Identification and Ranking Table (PIRT). Furthermore, numerous V&V examples guided by the PIRT for a simple gas discharge are shown to demonstrate the V&V process applied to a real-world simulation tool with the overall goal to demonstrably increase the confidence in the results for the simulation tool and its predictive capability. Although many examples are provided here to demonstrate elements of the framework, the primary goal of this work is to introduce this framework and not to provide a fully complete implementation, which would be a much longer document. Comparisons and contrasts are made to more usual approaches to V&V, and techniques new to the low-temperature plasma community are introduced. Specific challenges relating to the sufficiency of available data (e.g., cross sections), the limits of ad hoc validation approaches, the additional difficulty of utilizing a stochastic simulation tool, and the extreme cost of formal validation are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

NJOY2016

NJOY2016 is used to convert evaluations in the Evaluated Nuclear Data Files (ENDF) format into forms useful for practical applications such as fission and fusion reactor analysis, criticality safety, radiation shielding, nuclear waste management, nuclear medicine procedures, and more. It begins with the generation of pointwise libraries, including reaction and resonance reconstruction, Doppler broadening, radiation heating and damage, thermal scattering data, unresolved resonance data, and gas production. It reviews the production of libraries for the continuous-energy Monte Carlo code MCNP, multigroup neutron, photon, and particle cross sections and matrices, and photon interaction data. Uncertainty information for ENDF data is processed, including the capability for calculating covariances of resonance data, angular distributions, energy distributions, and radioactive nuclide production. NJOY can prepare and process thermal scattering data evaluations into application libraries. It can also plot cross sections, angular distributions and secondary emission spectra.

Kahler III, A. C. (Skip)↗