Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

F-8 refueling boom ground vibration test

A ground vibration test was conducted on a simulated refueling boom mounted on an F-8 airplane. The ground vibration test was conducted to determine if the refueling boom modal frequencies were close to the airplane frequencies. The data presented in this report include modal frequencies, mode shape data, and structural damping coefficients.

Kahoe, M. W.↗

Comparison of Predicted and Measured Attenuation of Turbine Noise from a Static Engine Test

Aircraft noise has become an increasing concern for commercial airlines. Worldwide demand for quieter aircraft is increasing, making the prediction of engine noise suppression one of the most important fields of research. The Low-Pressure Turbine (LPT) can be an important noise source during the approach condition for commercial aircraft. The National Aeronautics and Space Administration (NASA), Pratt & Whitney (P&W), and Goodrich Aerostructures (Goodrich) conducted a joint program to validate a method for predicting turbine noise attenuation. The method includes noise-source estimation, acoustic treatment impedance prediction, and in-duct noise propagation analysis. Two noise propagation prediction codes, Eversman Finite Element Method (FEM) code [1] and the CDUCT-LaRC [2] code, were used in this study to compare the predicted and the measured turbine noise attenuation from a static engine test. In this paper, the test setup, test configurations and test results are detailed in Section II. A description of the input parameters, including estimated noise modal content (in terms of acoustic potential), and acoustic treatment impedance values are provided in Section III. The prediction-to-test correlation study results are illustrated and discussed in Section IV and V for the FEM and the CDUCT-LaRC codes, respectively, and a summary of the results is presented in Section VI.

Chien, Eugene W.↗

Room Temperature Tensile Behavior and Damage Accumulation of Hi-Nicalon Reinforced SiC Matrix Composites

Composites consisting of woven Hi-Nicalon fibers, BN interphases, and different SiC matrices were studied in tension at room temperature. Composites with SiC matrices processed by CVI and melt infiltration were compared. Monotonic and load/unload/reload tensile hysteresis experiments were performed. A modal acoustic emission (AE) analyzer was used to monitor damage accumulation during the tensile test. Post test polishing of the tensile gage sections was performed to determine the extent of cracking. The occurrence and location of cracking could easily be determined using modal AE. The loss of modulus could also effectively be determined from the change in the velocity of sound across the sample. Finally, the stresses where cracks appear to intersect the load-bearing fibers correspond with high temperature low cycle fatigue run out stresses for these materials.

Morscher, G. N.↗

Pulmonary Ventilation Imaging Based on 4-Dimensional Computed Tomography: Comparison With Pulmonary Function Tests and SPECT Ventilation Images

Purpose: 4-dimensional computed tomography (4D-CT)-based pulmonary ventilation imaging is an emerging functional imaging modality. The purpose of this study was to investigate the physiological significance of 4D-CT ventilation imaging by comparison with pulmonary function test (PFT) measurements and single-photon emission CT (SPECT) ventilation images, which are the clinical references for global and regional lung function, respectively. Methods and Materials: In an institutional review board–approved prospective clinical trial, 4D-CT imaging and PFT and/or SPECT ventilation imaging were performed in thoracic cancer patients. Regional ventilation (V{sub 4DCT}) was calculated by deformable image registration of 4D-CT images and quantitative analysis for regional volume change. V{sub 4DCT} defect parameters were compared with the PFT measurements (forced expiratory volume in 1 second (FEV{sub 1}; % predicted) and FEV{sub 1}/forced vital capacity (FVC; %). V{sub 4DCT} was also compared with SPECT ventilation (V{sub SPECT}) to (1) test whether V{sub 4DCT} in V{sub SPECT} defect regions is significantly lower than in nondefect regions by using the 2-tailed t test; (2) to quantify the spatial overlap between V{sub 4DCT} and V{sub SPECT} defect regions with Dice similarity coefficient (DSC); and (3) to test ventral-to-dorsal gradients by using the 2-tailed t test. Results: Of 21 patients enrolled in the study, 18 patients for whom 4D-CT and either PFT or SPECT were acquired were included in the analysis. V{sub 4DCT} defect parameters were found to have significant, moderate correlations with PFT measurements. For example, V{sub 4DCT}{sup HU} defect volume increased significantly with decreasing FEV{sub 1}/FVC (R=−0.65, P<.01). V{sub 4DCT} in V{sub SPECT} defect regions was significantly lower than in nondefect regions (mean V{sub 4DCT}{sup HU} 0.049 vs 0.076, P<.01). The average DSCs for the spatial overlap with SPECT ventilation defect regions were only moderate (V{sub 4DCT}{sup HU}0.39 ± 0.11). Furthermore, ventral-to-dorsal gradients of V{sub 4DCT} were strong (V{sub 4DCT}{sup HU} R{sup 2} = 0.69, P=.08), which was similar to V{sub SPECT} (R{sup 2} = 0.96, P<.01). Conclusions: An 18-patient study demonstrated significant correlations between 4D-CT ventilation and PFT measurements as well as SPECT ventilation, providing evidence toward the validation of 4D-CT ventilation imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suppression of fiber modal noise induced radial velocity errors for bright emission-line calibration sources

Modal noise in optical fibers imposes limits on the signal-to-noise ratio (S/N) and velocity precision achievable with the next generation of astronomical spectrographs. This is an increasingly pressing problem for precision radial velocity spectrographs in the near-infrared (NIR) and optical that require both high stability of the observed line profiles and high S/N. Many of these spectrographs plan to use highly coherent emission-line calibration sources like laser frequency combs and Fabry-Perot etalons to achieve precision sufficient to detect terrestrial-mass planets. These high-precision calibration sources often use single-mode fibers or highly coherent sources. Coupling light from single-mode fibers to multi-mode fibers leads to only a very low number of modes being excited, thereby exacerbating the modal noise measured by the spectrograph. We present a commercial off-the-shelf solution that significantly mitigates modal noise at all optical and NIR wavelengths, and which can be applied to spectrograph calibration systems. Our solution uses an integrating sphere in conjunction with a diffuser that is moved rapidly using electrostrictive polymers, and is generally superior to most tested forms of mechanical fiber agitation. We demonstrate a high level of modal noise reduction with a narrow bandwidth 1550 nm laser. Our relatively inexpensive solution immediately enables spectrographs to take advantage of the innate precision of bright state-of-the art calibration sources by removing a major source of systematic noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Intermodal transfer in temporal discrimination

This study determined if training for accuracy in temporal discrimination would transfer across sensory modalities. A fractionation method was used in which subjects bisected the durations of acoustic and visual signals at three standard intervals (6, 12, and 18 sec). Absolute error was the performance index. Half of the subjects were trained with acoustic stimuli and then tested in vision; the remainder were trained in vision and tested in audition. Similar negatively accelerated acquisition functions were noted for both modalities. Positive intermodal transfer, characterized by symmetry across modalities, was obtained at all standard durations. The results were considered to provide support for the notion that a common mechanism underlies temporal discriminations in different sensory systems.

Warm, J. S.↗

Correlation of Electrical Resistance to CMC Stress-Strain and Fracture Behavior Under High Heat-Flux Thermal and Stress Gradients

Because SiCSiC ceramic matrix composites (CMCs) are under consideration for use as turbine engine hot-section components in extreme environments, it becomes necessary to investigate their performance and damage morphologies under complex loading and environmental conditions. Monitoring of electrical resistance (ER) has been shown as an effective tool for detecting damage accumulation of woven melt-infiltrated SiCSiC CMCs. However, ER change under complicated thermo-mechanical loading is not well understood. In this study a systematic approach is taken to determine the capabilities of ER as a relevant non-destructive evaluation technique for high heat-flux testing, including thermal gradients and localized stress concentrations. Room temperature and high temperature, laser-based tensile tests were conducted in which stress-dependent damage locations were determined using modal acoustic emission (AE) monitoring and compared to full-field strain mapping using digital image correlation (DIC). This information is then compared with the results of in-situ ER monitoring, post-test ER inspection and fractography in order to correlate ER response to convoluted loading conditions and damage evolution.

electrical resistance↗

Vibration Test Force Limits Derived From Frequency Shift Method

The two-degree-of-freedom system (TDFS) method used to derive force specifications for force limited vibration tests at JPL is reviewed and some of the limitations of the method and of the simple TDFS model are discussed. A new improved frequency shift force prediction method is developed and applied to a more complex model where the load and source have both residual and modal masses.

force↗

Experiences in using modal synthesis within project requirements

Modal synthesis methods were developed for use by engineers for cost-effective solutions of large structural dynamics problems. Different methods were proposed by various investigators based upon comparative solutions of relatively simple structures using different forms of displacement functions. The application of modal synthesis methods to a large complex structure in a project environment is described. The considerations include analysis, hardware interfaces, schedules, tests, resources, and other project requirements. Good technical results were obtained through the use of an integrated analysis/test modal synthesis on both substructures and systems.

Garba, J. A.↗

DGEN Aeropropulsion Research Turbofan Core/Combustor-Noise Measurements-Experiment and Modal Structure at Core-Nozzle Exit

Data from a recent core/combustor-noise source-diagnostic test utilizing a small turbo-fan engine are analyzed. The campaign continued the exploration begun in a baseline test, but with more extensive acoustic instrumentation. Both tests were aimed at developing a better understanding of propulsion-noise sources and their impact on the farfield noise signature, in order to enable improved turbofan noise-prediction methods and noise-mitigation techniques. Simultaneous high-data-rate acoustic measurements (93 channels in total) were obtained using a circumferential sensor array at the core-nozzle exit in conjunction with sideline and farfield microphone arrays for several relevant engine operational points. Measurements were repeated for different circumferential and sideline array configurations, as well as for redundancy. The unsteady pressure field at the core-nozzle exit is documented in detail. Previous work suggested that the±1azimuthal duct mode could be cut-on at this location, which would have implications for combustor-noise modeling and prediction. The modal decomposition of the combustor noise at the core-nozzle exit verifies this observation. Select farfield sound-pressure-level spectra are also presented.

Aeroacoustics↗

Validation of a Numerical Method for Determining Liner Impedance

This paper reports the initial results of a test series to evaluate a method for determining the normal incidence impedance of a locally reacting acoustically absorbing liner, located on the lower wall of a duct in a grazing incidence, multi-modal, non-progressive acoustic wave environment without flow. This initial evaluation is accomplished by testing the methods' ability to converge to the known normal incidence impedance of a solid steel plate, and to the normal incidence impedance of an absorbing test specimen whose impedance was measured in a conventional normal incidence tube. The method is shown to converge to the normal incident impedance values and thus to be an adequate tool for determining the impedance of specimens in a grazing incidence, multi-modal, nonprogressive acoustic wave environment for a broad range of source frequencies.

Watson, Willie R.↗

SU-E-T-01: (In)dependence of Plan Quality On Treatment Modalities and Target-To-Critical Structure Geometry for Brain Tumor

Purpose: To evaluate and test the hypothesis that plan quality may be systematically affected by treatment delivery techniques and target-tocritical structure geometric relationship in radiotherapy for brain tumor. Methods: Thirty-four consecutive brain tumor patients treated between 2011–2014 were analyzed. Among this cohort, 10 were planned with 3DCRT, 11 with RadipArc, and 13 with helical IMRT on TomoTherapy. The selected dosimetric endpoints (i.e., PTV V100, maximum brainstem/chiasm/ optic nerve doses) were considered as a vector in a highdimensional space. A Pareto analysis was performed to identify the subset of Pareto-efficient plans.The geometric relationships, specifically the overlapping volume and centroid-of-mass distance between each critical structure to the PTV were extracted as potential geometric features. The classification-tree analyses were repeated using these geometric features with and without the treatment modality as an additional categorical predictor. In both scenarios, the dominant features to prognosticate the Pareto membership were identified and the tree structures to provide optimal inference were recorded. The classification performance was further analyzed to determine the role of treatment modality in affecting plan quality. Results: Seven Pareto-efficient plans were identified based on dosimetric endpoints (3 from 3DCRT, 3 from RapicArc, 1 from Tomo), which implies that the evaluated treatment modality may have a minor influence on plan quality. Classification trees with/without the treatment modality as a predictor both achieved accuracy of 88.2%: with 100% sensitivity and 87.1% specificity for the former, and 66.7% sensitivity and 96.0% specificity for the latter. The coincidence of accuracy from both analyses further indicates no-to-weak dependence of plan quality on treatment modality. Both analyses have identified the brainstem to PTV distance as the primary predictive feature for Pareto-efficiency. Conclusion: Pareto evaluation and classification-tree analyses have indicated that plan quality depends strongly on geometry for brain tumor, specifically PTV-tobrain-stem-distance but minimally on treatment modality.

60 APPLIED LIFE SCIENCES↗

Test–retest repeatability of myocardial oxidative metabolism and efficiency using standalone dynamic {sup 11}C-acetate PET and multimodality approaches in healthy controls

Background: Myocardial efficiency measured by {sup 11}C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. Methods and Results: Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using {sup 11}C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEE{sub CMR}, MEE{sub Echo}, and MEE{sub PET} values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P < .001. WMI{sub CMR}, WMI{sub Echo}, and WMI{sub PET} values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m{sup 2} × 10{sup 6}, respectively, P = .45. Repeatability for MEE{sub CMR} was superior compared with MEE{sub Echo} but did not differ significantly compared with MEE{sub PET} (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMI{sub CMR}, WMI{sub Echo}, and WMI{sub PET} were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). Conclusions: Non-invasive measurements of MEE using {sup 11}C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modal identification using single-mode projection filters and comparison with ERA and MLE results

The Single-Mode Projection Filter (SPF) is a newly developed algorithm for eigensystem parameter identification from both analytical results and test data. The SPF is formulated with a single mode only and practical for parallel processing implementation. Explicit formulations of SPF are derived for the multi-input multi-output (MIMO) system by using the orthogonal matrices of the controllability and observability matrices in the general sense. The modal parameters of SPF are initially obtained from an analytical model in modal space. The experimental data are then processed through SPF to update its modal parameters and to minimize a cost function defined by the norm of an error matrix. The updated modal parameters represent the characteristics of the test data. A two-dimensional global minimum optimization algorithm is developed and applied for the filter update by using the interval analysis method. The SPF is developed based on a single-mode subsystem and identifies only one modal frequency and one modal damping within a specified region. For an n-modes structure, n SPF can be implemented for parallel processing to reduce the computational burden. The SPF is applied to analyze the simulated data for the MAST beam structure. The estimated modal parameters are comparable to those from the Eigensystem Realization Algorithm (ERA) and repeated modal frequencies are identified. The modal analysis of the Spacecraft Control Laboratory Experiment (SCOLE) data is also performed by using the ERA and the Maximum Likelihood Estimate (MLE). The result shows that the first five modal frequencies are very close from ERA and MLE. However, there are slight disparities in the damping rates and the computational burdens are quite different among these two algorithms.

Huang, Jen-Kuang↗

Experimental and analytical investigations of fuselage modal characteristics and structural-acoustic coupling

Measurements conducted on a DC-9 aircraft test section to define the shell and cavity modes of the fuselage, understand its structural-acoustic coupling characteristics, and measure its response to different types of acoustic and vibration excitations are reported. The data were processed to generate spatial plots and wavenumber maps of the shell acceleration and cabin acoustic pressure field. Analysis and interpretation of the spatial plots and wavenumber maps showed that the only structural-acoustic coupling occurred at 105 Hz between the N=2 circumferential structural mode and the (n=2, p=0) circumferential cavity mode. The fuselage response to vibration excitation was found to be dominated by modes whose order increases with frequency.

Simpson, Myles A.↗

Free-decay time-domain modal identification for large space structures

Concept definition studies for the Modal Identification Experiment (MIE), a proposed space flight experiment for the Space Station Freedom (SSF), have demonstrated advantages and compatibility of free-decay time-domain modal identification techniques with the on-orbit operational constraints of large space structures. Since practical experience with modal identification using actual free-decay responses of large space structures is very limited, several numerical and test data reduction studies were conducted. Major issues and solutions were addressed, including closely-spaced modes, wide frequency range of interest, data acquisition errors, sampling delay, excitation limitations, nonlinearities, and unknown disturbances during free-decay data acquisition. The data processing strategies developed in these studies were applied to numerical simulations of the MIE, test data from a deployable truss, and launch vehicle flight data. Results of these studies indicate free-decay time-domain modal identification methods can provide accurate modal parameters necessary to characterize the structural dynamics of large space structures.

Kim, Hyoung M.↗

Analysis and testing of large space structures

Considerations and approaches to the ground testing of large space structures are discussed. The large size combined with the loading due to gravity makes testing of the complete structure difficult. Gravitational stiffening, suspension effects, virtual air mass, preloads, and air damping alter the dynamic characteristics. Low resonant frequencies and high modal densities within the frequency range of interest combine with small motions and accelerations to make testing difficult. Mechanism complexities and nonlinearities associated with space-erected/assembled structures cause structural complexity regardless of other considerations. Ground test approaches include scale models, element and substructure tests, and structural linearization. Analytical approaches are also discussed.

Stahle, C. V.↗

AFRL Additive Manufacturing Modeling Series: Challenge 4, In Situ Mechanical Test of an IN625 Sample with Concurrent High-Energy Diffraction Microscopy Characterization

In this work, we describe 3D characterization of an additively manufactured Inconel 625 nickel-base superalloy specimen conducted during a uniaxial tension test using a suite of nondestructive x-ray techniques. High-energy diffraction microscopy in both near- and far-field modalities are employed in situ to track evolution of the material orientation and stress–strain fields at six points during the mechanical test, and these data streams are registered with micro-computed tomography reconstructions which probe the material density. This data volume was matched to a multi-modal serial sectioning characterization of the specimen taken after loading, described in this article’s companion. Twenty-eight grains which were monitored throughout the experiment were selected to form the basis for AFRL AM Modeling Series Challenge 4, Microscale Structure-to-Properties.

36 MATERIALS SCIENCE↗