Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Exploring the feasibility of crack detection in plate weldments through an interposed layer of viscoelastic material.

Development of new approaches in the nondestructive evaluation of welded steel plates for large naval structures continues to be an area of interest for the DoD and the military complex. In this report we will evaluate an elastic-microwave based detection and imaging method using both numerical finite element (3D FEM) and experimental methods. The evaluation was performed on two test articles that were designed to represent critical structural components with flaws of interest. Details of the materials and the mechanical drawings were provided with the test articles. Flaws, cracks and weld defects have been included in the test articles to determine detection sensitivity and accuracy of the proposed method. Our approach uses a microwave interferometer (MI) to record the scattered response of flaws in the steel plated as it is driven by an incident elastic field. The MI can “see” (penetrate) through the viscoelastic coating to the upper surface of the plate. Out-of-plane displacement amplitudes of 10nm in the frequency range (1kHz to 25kHz) are readily observable, with the key feature being, that the surface bond between the coating and the steel plate are undisturbed. The non-contact aspect of the interferometer allows for large surface regions to be accurately and efficiently scanned in space and time. Spatiotemporal data sets of this kind and specialized wavefield processing provide powerful detection and imaging modalities. From these wavefield data sets, a plate thickness mapping capability has been demonstrated that can detect thickness changes on the order of 0.79 mm (1/32”) with spatial resolution on the order of the spatial sampling rate, 15mm (~5/8”). We have also shown that a topological energy analysis of the wavefield data can detect and locate small flaws, on the order of 5-10 mm (0.025-0.40”) in the welded joint of a 1.5” thick T-plate. As before, these results are obtained through a 2” thick viscoelastic coating without altering the integrity of coating or the coating bond. These results show that we are detecting and locating damage (flaws) in the plate that are much smaller than the wavelength of the propagating guided modes. Classical scattering theory places a (λ/2) resolution limit on the detectability of flaws in terms of the incident field [22], however, since the spatial resolution of the scanned region is much smaller, (Δx=Δy=15mm) and the inherent natural focusing of the time reversal operation, we are able to detect smaller flaws on the order of (λ/10). It is important to realize that we are not imaging the flaw but detecting and localizing a difference between a reference (pristine) sample and the measured (damaged) sample, relative to a spatial grid on the surface. The current scan resolution is 15mm x 15mm. At present we cannot expect to resolve individual flaws within a grid space only their cumulative effect. Even with the current limitations, this imaging approach appears to be a promising alternative to current methods where the coating layer is removed.

36 MATERIALS SCIENCE↗

Limit Cycle Oscillating Detonation Wave Behavior Analysis Within a Rotating Detonation Engine

Limit cycle oscillation (LCO) detonation wave behaviors are presented and analyzed for test times exceeding 20 s in a water-cooled rotating detonation engine (RDE). LCO detonation waves exhibit cyclic acceleration and deceleration, resulting in oscillating wave spacing at unique process conditions. In previous RDE studies, similar behaviors have been studied as microsecond-scale instabilities leading to ascending or descending modal transitions. In the current work, however, LCO waves are considered a persistent wave mode, occupying unique portions of the operational envelope adjacent to those of their equally spaced counterparts. These occurrences of LCO waves are repeatable, enduring behaviors. A method to generate shifted contour surfaces specifically intended to extract and analyze wave spacing variation through time, termed limit cycle oscillation visualization (LCOV) surfaces, is presented. LCOV surfaces transform data into the reference frame of a primary traveling wave and are used to analyze quasi-steady, short-timescale, and transitional LCO modes. Results are leveraged to understand the relationship between fill height, wave strength, local wave acceleration, and subsequent LCO wave spacing for individual wave sets. In conclusion, quasi-steady LCO waves display wave spacing oscillations between equal spacing values associated with ±1 wave across runs exceeding 18 s.

33 ADVANCED PROPULSION SYSTEMS↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

Timing of treatment in small-cell lung cancer

Small-cell lung cancer (SCLC) is an aggressive disease with poor survival and rapid doubling time. Current practice is to treat SCLC as soon as possible but evidence on appropriate timing of treatment from diagnosis (TTD) is lacking. This is a retrospective analysis of SCLC patients from the 2012 to 2015 Kentucky Cancer Registry. Data collected included age at diagnosis, stage, gender, race, insurance and treatment. Factors and survival associated with TTD were identified with logistic regression analyses and Cox proportional hazards models. Among the 2992 SCLC patients, 2371 (79%) of SCLC patients were treated with one or more treatment modalities. Among treated patients, 93% received chemotherapy ± radiation with the mean TTD of 18 days. Most patients (80%) have TTD of ≤ 4 weeks with 33% treated within 1 week, 20% 1–2 weeks, and 27% 2–4 weeks from diagnosis. Delay in treatment (TTD > 4 weeks) was less in stage III and IV disease (odds ratio: 0.33 and 0.27 respectively, p < 0.01) but not significantly associated with age, race, gender, and insurance. One and two-year survival of patients with TTD ≤ 4 weeks was significantly worse when compared to > 4 weeks (hazard ratio = 1.43, 95% CI 1.2–1.6, p < 0.01; HR = 1.45, 95% CI 1.3–1.6, p < 0.01 respectively). These results show a trend toward better survival with late treatment of SCLC. Therefore, a general urgency to treat SCLC needs to be re-evaluated with consideration of patients needing more optimization before treatment. Further studies are needed to better clarify the appropriate timing of treatment from diagnosis in SCLC and who will benefit from early versus late treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-C-12A-01: Quantitative Imaging Initiatives: Why, Who, What, and How?

Over the past decade, there has been an increasing focus on quantitative imaging (QI), which, according to one definition, is “the extraction of quantifiable features from medical images for the assessment of normal or the severity, degree of change, or status of a disease, injury, or chronic condition relative to normal” ( www.rsna.org/QIBA ). To achieve the goals of QI requires the development and standardization of data acquisition, data analysis, and data display techniques, as well as appropriate reporting structures. As such, successful implementation of QI relies heavily on expertise from the fields of medical physics, radiology, statistics, and informatics as well as collaboration from vendors of imaging acquisition, analysis, and reporting systems. When successfully implemented, QI techniques will provide image-derived metrics with known bias and variance that can be validated with anatomically and physiologically relevant measures, including treatment response, and the heterogeneity of that response, and outcome. Such non-invasive measures can then be used effectively in clinical and translational research as well as patient care. In addition to modality-specific QI efforts implemented by individual scientific organizations, national and international organizations, including the NCI, RSNA, FDA, and NIST, appreciating the tremendous potential of QI but also understanding the associated challenges, have become increasingly involved. This symposium session will focus on 1) introducing QI and illustrating why it is important, even though challenging, in both research and clinical applications, and 2) providing overviews of QI efforts from national and international organizations, including the RSNA, NCI, FDA, and NIST. Learning Objectives: Understand the importance and potential of QI in research and clinical applications. Understand key challenges of QI and current barriers to implementation. Understand the current QI efforts of several national and international agencies and organizations, including the FDA, NCI, NIST, and RSNA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alloying effects on deformation induced microstructure evolution in copper

In this work, we investigated the effects of alloying elements on plastic deformation and microstructure evolution in polycrystalline copper (Cu) and Cu alloyed with 1 wt. % lead (Cu-1 %Pb). These materials were selected due to the size mismatch between Cu and Pb, with the latter forming precipitates at grain boundaries. Multi-modal characterization techniques, including neutron diffraction, electron backscatter diffraction (EBSD), and transmission electron microscopy (TEM), along with finite element simulations were employed to study the deformation behavior across multiple length scales. While both Cu and Cu-1%Pb exhibited similar macroscale response and final deformation textures, both dislocation line profile analysis and TEM revealed increased dislocation density in deformed Cu-1%Pb specimens. The presence of lead precipitates also significantly affected local plastic deformation during compression, with their influence diminishing with increasing strain. These results demonstrate the complex relationships between alloying elements, plastic deformation, microstructural evolution, and material behavior under load. The insights gained from this multi-scale and multi-technique approach contribute to the fundamental understanding of microstructural evolution in immiscible alloys and are valuable for tailoring the properties of structural materials for specific engineering applications.

36 MATERIALS SCIENCE↗

Properties of different LLM-105 preparations

LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide) has been prepared at several different size quantities (~10–70 Kg) and not subjected to further purification, such as recrystallization. Chemical and physical properties were compared—small-scale safety testing (impact, friction, ESD), thermal (chemical reactivity, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), one-dimensional time-to-explosion (ODTX)), morphological (particle-size distribution (PSD), scanning electron microscopy (SEM), powder x-ray diffraction (PXRD), skeletal density). Each preparation had similar properties to the other preparations except for PSD and PXRD. For PSD, all preparations exhibited a mono-modal distribution with a variation in median values from ~ 40 μm to over 80 μm. All PXRD values indicated the same morphology with minor variations in crystal orientations. Possible polymorphism was also observed in a few cases. SEM images and PXRD indicate all preparations to be diamond-type and X-type crystals with some twinning. Impact, friction, and ESD and thermal sensitivities values are consistent with these type of crystal habits as seen in vast literature studies.

Explosive characterization↗

Categorical Dimensions of Human Odor Descriptor Space Revealed by Non-Negative Matrix Factorization

In contrast to most other sensory modalities, the basic perceptual dimensions of olfaction remain unclear. Here, we use nonnegative matrix factorization (NMF) – a dimensionality reduction technique – to uncover structure in a panel of odor profiles, with each odor defined as a point in multi-dimensional descriptor space. The properties of NMF are favorable for the analysis of such lexical and perceptual data, and lead to a high-dimensional account of odor space. We further provide evidence that odor dimensions apply categorically. That is, odor space is not occupied homogenously, but rather in a discrete and intrinsically clustered manner. We discuss the potential implications of these results for the neural coding of odors, as well as for developing classifiers on larger datasets that may be useful for predicting perceptual qualities from chemical structures.

59 BASIC BIOLOGICAL SCIENCES↗

Quality Control of Involved Field Radiotherapy in Patients With Early-Favorable (HD10) and Early-Unfavorable (HD11) Hodgkin's Lymphoma: An Analysis of the German Hodgkin Study Group

Purpose: The German Hodgkin Study Group (GHSG) set up a radiotherapy (RT) reference center within the Department of Radiation Oncology at University of Cologne to undertake quality assurance of the group's clinical studies. In the HD10 trial (early-favorable stages) and HD11 trial (early-unfavorable stages) all patients received involved field (IF)-RT (30 Gy vs. 20 Gy) within a combined-modality approach. For these patients a central prospective review of all diagnostic imaging was performed by expert radiation oncologists to control disease extension and to define IF treatment volume. Methods and Materials: On the basis of simulation films, verification films, and radiotherapy case report form (CRF) an expert panel evaluated retrospectively the adequacy of irradiated IF treatment portals according to the RT prescription, applied radiation doses, treatment time, and technical parameters. Results: Between 1999 and 2006 a total of 825 of 1370 randomized patients of the HD10 trial (60%) and 954 of 1422 patients of the HD11 trial (67%) were evaluated by the panel. Radiotherapy was rated as suboptimal in 47% of all reviewed cases. Although the participating RT centers received a precise RT prescription, most difficulties occurred in the adequate coverage of the IF (40%), followed by technical faults (12%). Deviations from the prescribed single daily dose (1.8-2 Gy), weekly dose, and total reference dose were rare (1%). Conclusions: As a consequence of these findings, radiation oncologists were trained on the definition of IF-RT at GHSG meetings and at the annual meetings of the German Society for Therapeutic Radiation Oncology. Possible correlations between RT quality and relapse rate will be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-89: Comparative Analysis of MIM and Velocity’s Image Deformation Algorithm Using Simulated KV-CBCT Images for Quality Assurance

Purpose: Deformable image registration (DIR) is used routinely in the clinic without a formalized quality assurance (QA) process. Using simulated deformations to digitally deform images in a known way and comparing to DIR algorithm predictions is a powerful technique for DIR QA. This technique must also simulate realistic image noise and artifacts, especially between modalities. This study developed an algorithm to create simulated daily kV cone-beam computed-tomography (CBCT) images from CT images for DIR QA between these modalities. Methods: A Catphan and physical head-and-neck phantom, with known deformations, were used. CT and kV-CBCT images of the Catphan were utilized to characterize the changes in Hounsfield units, noise, and image cupping that occur between these imaging modalities. The algorithm then imprinted these changes onto a CT image of the deformed head-and-neck phantom, thereby creating a simulated-CBCT image. CT and kV-CBCT images of the undeformed and deformed head-and-neck phantom were also acquired. The Velocity and MIM DIR algorithms were applied between the undeformed CT image and each of the deformed CT, CBCT, and simulated-CBCT images to obtain predicted deformations. The error between the known and predicted deformations was used as a metric to evaluate the quality of the simulated-CBCT image. Ideally, the simulated-CBCT image registration would produce the same accuracy as the deformed CBCT image registration. Results: For Velocity, the mean error was 1.4 mm for the CT-CT registration, 1.7 mm for the CT-CBCT registration, and 1.4 mm for the CT-simulated-CBCT registration. These same numbers were 1.5, 4.5, and 5.9 mm, respectively, for MIM. Conclusion: All cases produced similar accuracy for Velocity. MIM produced similar values of accuracy for CT-CT registration, but was not as accurate for CT-CBCT registrations. The MIM simulated-CBCT registration followed this same trend, but overestimated MIM DIR errors relative to the CT-CBCT registration.

60 APPLIED LIFE SCIENCES↗

Classification and imaging of spent nuclear fuel dry casks using cosmic ray muons - 132

The present work explores alternative approaches for in situ monitoring with near real-time data analysis and imaging of dry casks using muons. Monitoring can provide useful signals about the cask contents in a yes/no decision format faster and with fewer muons than traditional imaging. Imaging can be performed as a second step in this process if specific information about the location of the fuel assemblies is needed. To explore and analyze these two modalities, simulations of muon scattering and displacement were performed for various scenarios, including vertical and horizontal fully loaded dry casks, half-loaded dry casks, dry casks with one row of fuel assemblies missing, dry casks with one fuel assembly missing, and empty dry casks. This work demonstrates monitoring can provide fast and reliable indication about the contents of the cask. For 100,000 muons, a few minutes of measurement time with a 3.6 m{sup 2} detector at a 45 deg. zenith angle, 90% detection probability for missing fuel assemblies can be achieved with a false alarm rate lower than 1%. If a positive signal is detected, then longer measurements can be performed and coupled with muon imaging algorithms to determine the location of missing nuclear material. In these cases, transmission muon radiography can produce images of acceptable resolution for all scenarios. In the horizontal dry cask case, all scenarios can be identified and separated adequately. In the vertical dry cask case, similar conclusions can be drawn, but because of shadowing from other fuel assemblies, the location of a missing fuel assembly cannot be identified in the 2-D transmission map. However, views from different directions may resolve this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A four‐alternative forced choice (4AFC) methodology for evaluating microcalcification detection in clinical full‐field digital mammography (FFDM) and digital breast tomosynthesis (DBT) systems using an inkjet‐printed anthropomorphic phantom

Purpose The advent of three‐dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clinical trials are the gold standard for assessing image quality, phantom‐based studies can provide a simpler and less burdensome approach. In this work, a complete framework is presented for task‐based evaluation of microcalcification (MCs) detection performance for DBT imaging systems. Methods The framework consists of three parts. The first part is a realistic anthropomorphic physical breast phantom created through inkjet printing, with parchment paper and iodine‐doped ink. The second is a method for inserting realistic MCs fabricated from calcium hydroxyapatite. The reproducibility and stability of the phantom materials were investigated through multiple samples of parchment and ink over 6 months. The final part is an analysis using a four‐alternative forced choice (4AFC) reader study. To demonstrate the framework, a task‐based 4AFC study was conducted using a clinical system to compare performance from DBT, synthetic mammography (SM), and full‐field digital mammography (FFDM). Nine human observers read images containing MC clusters imaged with all three modalities and tried to correctly locate the MCs. The proportion correct (PC) was measured as the number of correctly detected clusters out of all trials. Results Overall, readers scored the highest with FFDM, (PC = 0.95 ± 0.03) then DBT (0.85 ± 0.04), and finally SM (0.44 ± 0.06). For the parchment and ink samples, the linear attenuation properties were very stable over 6 months. In addition, little difference was found between the various parchment and ink samples, indicating good reproducibility. Conclusions This framework presents a promising methodology for evaluating diagnostic task performance of clinical breast DBT systems.

Ikejimba, Lynda C.↗

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

X-ray spectroscopic methods↗

An OVERVIEW of MICROPHONICS in CEBAF and CURRENT MODERATION TECHNIQUES

Superconducting RF (SRF) structures are susceptible to frequency detuning from external vibrations and modal mechanical resonances in the structure. These small disturbances, known as microphonics, require additional RF power in CW accelerating structures since the frequency is constantly shifting. In the Jefferson Lab CEBAF accelerator, time and frequency data of this frequency shift have been recorded for many years, allowing a retrospective analysis of different microphonics-mitigation techniques. Some of these techniques are specific to the design of each CEBAF cryomodule, for example implementing BNNT damping material on the cavity string. Other techniques are universal such as affixing vacuum lines and reinforcing waveguide structures.

Powers, Tom↗

2001 New York State NHTS: Travel Patterns of Special Populations

Policymakers rely on transportation statistics, including data on personal travel behavior, to formulate strategic transportation policies, and to improve the safety and efficiency of the U.S. transportation system. Data on personal travel trends are needed to examine the reliability, efficiency, capacity, and flexibility of the Nation's transportation system to meet current demands and accommodate future demands; to assess the feasibility and efficiency of alternative congestion-alleviating technologies (e.g., high-speed rail, magnetically levitated trains, intelligent vehicle and highway systems); to evaluate the merits of alternative transportation investment programs; and to assess the energy-use and air-quality impacts of various policies. To address these data needs, the U.S. Department of Transportation (USDOT) initiated an effort in 1969 to collect detailed data on personal travel. The 1969 survey was the first Nationwide Personal Transportation Survey (NPTS). The survey was conducted again in 1977, 1983, 1990, 1995, and 2001. Data on daily travel were collected in 1969, 1977, 1983, 1990 and 1995. Longer-distance travel was collected in 1977 and 1995. The 2001 National Household Travel Survey (NHTS) collected both daily and longer-distance trips in one survey. The 2001 survey was sponsored by three USDOT agencies: Federal Highway Administration (FHWA), Bureau of Transportation Statistics (BTS), and National Highway Traffic Safety Administration (NHTSA). The primary objective of the survey was to collect trip-based data on the nature and characteristics of personal travel so that the relationships between the characteristics of personal travel and the demographics of the traveler can be established. Commercial and institutional travel was not part of the survey. New York State participated in the 2001 NHTS by procuring additional 12,000 sample households. These additional sample households allowed New York State to address transportation planning issues pertinent to geographic areas that are significantly smaller than what the national NHTS data allowed. The final sample size for New York State was 13,423 usable households. In this report, Oak Ridge National Laboratory (ORNL) identifies and analyzes differences, if any, in travel patterns that are attributable to demographic characteristics (e.g., gender, age, race and ethnicity), household characteristics (e.g., low income households, zero and one car households), modal characteristics and geographic location. Travel patterns of those who work at home are examined and compared to those of conventional workers, as well as those who do not work. Focus is given to trip frequency, travel by time of day, trip purpose, and mode choice. For example, included in this analysis is the mobility of the elderly population in New York State. The American society is undergoing a major demographic transformation that is resulting in a greater percentage of older individuals in the population. In addition to demographic changes, recent travel surveys show that an increasing number of older individuals are licensed to drive and that they drive more than their same age cohort did a decade ago. Cohort differences in driving are particularly apparent - not only are more of today's elderly population licensed to drive than their age cohort two decades ago, they also drive more. Equally important are the increase in immigration and in racial and cultural diversity. This report also discusses vehicle availability, socioeconomic characteristics, travel trends (e.g., miles travelled, distance driven, commute patterns), and the transportation accessibility of these populations. Specifically, this report addresses in detail the travel behavior of the following special populations: (1) the elderly, defined as those who were 65 years old or older, (2) low-income households, (3) ethnic groups and immigrants, and (4) those who worked at home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FRET-Based Quantum Dot Immunoassay for Rapid and Sensitive Detection of Aspergillus amstelodami

In this study, a fluorescence resonance energy transfer (FRET)-based quantum dot (QD) immunoassay for detection and identification of Aspergillus amstelodami was developed. Biosensors were formed by conjugating QDs to IgG antibodies and incubating with quencher-labeled analytes; QD energy was transferred to the quencher species through FRET, resulting in diminished fluorescence from the QD donor. During a detection event, quencher-labeled analytes are displaced by higher affinity target analytes, creating a detectable fluorescence signal increase from the QD donor. Conjugation and the resulting antibody:QD ratios were characterized with UV-Vis spectroscopy and QuantiT protein assay. The sensitivity of initial fluorescence experiments was compromised by inherent autofluorescence of mold spores, which produced low signal-to-noise and inconsistent readings. Therefore, excitation wavelength, QD, and quencher were adjusted to provide optimal signal-to-noise over spore background. Affinities of anti-Aspergillus antibody for different mold species were estimated with sandwich immunoassays, which identified A. fumigatus and A. amstelodami for use as quencher-labeled- and target-analytes, respectively. The optimized displacement immunoassay detected A. amstelodami concentrations as low as 10 3 spores/mL in five minutes or less. Additionally, baseline fluorescence was produced in the presence of 10 5 CFU/mL heat-killed E. coli O157:H7, demonstrating high specificity. This sensing modality may be useful for identification and detection of other biological threat agents, pending identification of suitable antibodies. Overall, these FRET-based QD-antibody biosensors represent a significant advancement in detection capabilities, offering sensitive and reliable detection of targets with applications in areas from biological terrorism defense to clinical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiosensitization by SAHA in Experimental Colorectal Carcinoma Models-In Vivo Effects and Relevance of Histone Acetylation Status

Purpose: Histone deacetylase inhibitors are being evaluated as antitumor agents in ongoing clinical trials, and promising preclinical results, combined with favorable toxicity profiles, have rendered the drugs as interesting candidates for combination with other treatment modalities, such as radiotherapy. The aim of the present study was to evaluate the radiosensitizing properties of suberoylanilide hydroxamic acid (SAHA) and the possible requirement of histone hyperacetylation at radiation exposure. Methods and materials: Radiosensitization by SAHA was assessed in a colorectal carcinoma cell line and in two colorectal xenograft models by analysis of clonogenic survival and tumor growth delay, respectively. Histone acetylation status at radiation exposure was evaluated by Western blot. Results: In vitro, radiosensitization was demonstrated when cells were preincubated with SAHA, and, in the xenografts, tumor growth was delayed when the mice were treated with fractionated radiation combined with daily SAHA injections compared with radiation alone. Surprisingly, the SAHA-dependent growth delay was still present when radiation was delivered at restored baseline acetylation levels compared with maximal histone hyperacetylation. Conclusion: SAHA was an effective radiosensitizer in experimental colorectal carcinoma models, suggesting that histone deacetylase inhibition might constitute a valuable supplement to current multimodal treatment strategies in rectal cancer. The presence of histone hyperacetylation at radiation was not required to obtain an increased radiation response, questioning the validity of using histone hyperacetylation as a molecular marker for radiosensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗