Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Post maximum light and late time optical imaging polarimetry of type I superluminous supernova 2020znr

ABSTRACT Optical imaging polarimetry was conducted on the hydrogen poor superluminous supernova 2020znr during three phases after maximum light (≈ +34 d, +288 d, and +289 d). After instrumental and interstellar polarization correction, all measurements are consistent with null-polarization detection. Modelling the light curve with a magnetar spin-down model shows that SN2020znr has similar magnetar and ejecta parameters to other SLSNe. A comparison of the best-fitting values discussed in the literature on SN 2017egm and SN 2015bn, two hydrogen poor SLSNe showing an increase of polarization after maximum light, suggests that SN 2020znr has higher mass ejecta that may prevent access to the geometry of the inner ejecta with optical polarimetry. The combined information provided by spectroscopy and light-curve analysis of type I SLSNe may be an interesting avenue to categorize the polarization properties of this class of transients. This approach would require to expand the sample of SLSNe polarimetry data currently available with early and late time epochs new measurements.

2015bn↗

Synthetic light-cone catalogues of modern redshift and weak lensing surveys with abacussummit

ABSTRACT The joint analysis of different cosmological probes, such as galaxy clustering and weak lensing, can potentially yield invaluable insights into the nature of the primordial Universe, dark energy, and dark matter. However, the development of high-fidelity theoretical models is a necessary stepping stone. Here, we present public high-resolution weak lensing maps on the light-cone, generated using the N-body simulation suite abacussummit, and accompanying weak lensing mock catalogues, tuned to the Early Data Release small-scale clustering measurements of the Dark Energy Spectroscopic Instrument. Available in this release are maps of the cosmic shear, deflection angle, and convergence fields at source redshifts ranging from z = 0.15 to 2.45 as well as cosmic microwave background convergence maps for each of the 25 base-resolution simulations ($L_{\rm box} = 2000\, h^{-1}\, {\rm Mpc}$ and Npart = 69123) as well as for the two huge simulations ($L_{\rm box} = 7500\, h^{-1}\, {\rm Mpc}$ and Npart = 86403) at the fiducial abacussummit cosmology. The pixel resolution of each map is 0.21 arcmin, corresponding to a healpix Nside of 16 384. The sky coverage of the base simulations is an octant until z ≈ 0.8 (decreasing to about 1800 deg2 at z ≈ 2.4), whereas the huge simulations offer full-sky coverage until z ≈ 2.2. Mock lensing source catalogues are sampled matching the ensemble properties of the Kilo-Degree Survey, Dark Energy Survey, and Hyper Suprime-Cam data sets. The mock catalogues are validated against theoretical predictions for various clustering and lensing statistics, such as correlation multipoles, galaxy–shear, and shear–shear, showing excellent agreement. All products can be downloaded via a Globus endpoint (see Data Availability section).

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the Cosmological Lyman-𝛼 Forest at the Field Level

The distribution of absorption lines in the spectra of distant quasars, called the Lyman-𝛼 (Ly-𝛼) forest, is a unique probe of cosmology and the intergalactic medium at high redshifts and small scales. The statistical power of ongoing redshift surveys demands precise theoretical tools to model the Ly-𝛼 forest. We address this challenge by developing an analytic, perturbative forward model to predict the Ly-𝛼 forest at the field level for a given set of cosmological initial conditions. Our model shows a remarkable performance when compared with the Sherwood hydrodynamic simulations: it reproduces the Ly-𝛼 forest flux power spectrum, its cross-correlation with dark matter halos, and the one-point probability distribution function of both fields at the percent level down to scales of a few Mpc. Our work provides crucial tools that bridge analytic modeling on large scales with simulations on small scales, enabling field-level inference from Ly-𝛼 forest data and simulation-based priors for cosmological analyses. Furthermore, this is especially timely for realizing the full scientific potential of the Ly-𝛼 forest measurements by the dark energy spectroscopic instrument.

Cosmological parameters↗

Nonuniform Absorption and Scattered Light in Direct-Drive Implosions Driven by Polarization Smoothing

Laser-direct-drive symmetric implosions on OMEGA illuminate a target with 60 laser beams and are designed to produce spherical implosions. Each beam is smoothed using orthogonal polarizations obtained by passing through distributed polarization rotators (DPR’s). Observations of the scattered light from OMEGA implosions do not show the expected symmetry and have much larger variation than standard predictions. For the first time, we have quantified the scattered-light nonuniformity from individual beams and identified the DPR’s as the source of the enhanced nonuniformity. An instrument was invented that isolated and measured the variation in the intensity and polarization of the light scattered from each OMEGA beam. The asymmetric intensity and polarization measurements are explained when the on-target offsets between the two orthogonal polarizations produced by the DPR’s are modeled using a 3-D cross-beam energy transfer (CBET) code that tracks the polarizations of each beam. The time-integrated nonuniformity in laser absorption and scattered light due to CBET and the DPR polarization offsets during high-performance OMEGA implosions is predicted to be significant and dominated by low spherical harmonic mode numbers. Further, the nonuniformity is predicted to be greatly reduced by replacing the DPR’s with new optics that create smaller offsets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on neutrino physics from DESI DR2 BAO and DR1 full shape

The Dark Energy Spectroscopic Instrument (DESI) Collaboration has obtained robust measurements of baryon acoustic oscillations in the redshift range 0.1 < 𝑧 < 4.2, based on the Lyman-𝛼 forest and galaxies from data release 2. We combine these measurements with cosmic microwave background (CMB) data from Planck and the Atacama Cosmology Telescope to place our tightest constraints yet on the sum of neutrino masses. Assuming the cosmological Λ⁢ CDM model and three degenerate neutrino states, we find ∑𝑚 𝜈 < 0.0642 eV (95%) with a marginalized error of 𝜎⁡(∑𝑚 𝜈 ) = 0.020 eV. We also constrain the effective number of neutrino species, finding 𝑁 eff = 3.2⁢3$^{+0.35}_{−0.34}$ (95%), in line with the Standard Model prediction. When accounting for neutrino oscillation constraints, we find a preference for the normal mass ordering and an upper limit on the lightest neutrino mass of 𝑚 𝑙 < 0.023 eV (95%). However, we determine using frequentist and Bayesian methods that our constraints are in tension with the lower limits derived from neutrino oscillations. Correcting for the physical boundary at zero mass, we report a 95% Feldman-Cousins upper limit of ∑𝑚 𝜈 < 0.053 eV, breaching the lower limit from neutrino oscillations. Considering a more general Bayesian analysis with an effective cosmological neutrino mass parameter, ∑𝑚 𝜈,eff , that allows for negative energy densities and removes unsatisfactory prior weight effects, we derive constraints that are in 3⁢𝜎 tension with the same oscillation limit, while the error rises to 𝜎⁡(∑𝑚 𝜈,eff ) = 0.053 eV. In the absence of unknown systematics, this finding could be interpreted as a hint of new physics not necessarily related to neutrinos. The preference of DESI and CMB data for an evolving dark energy model offers one possible solution. In the 𝑤 0 ⁢𝑤 𝑎 ⁢CDM model, we find ∑𝑚 𝜈 < 0.163 eV (95%), relaxing the neutrino tension. These constraints all rely on the effects of neutrinos on the cosmic expansion history. Using full-shape power spectrum measurements of data release 1 galaxies, we place complementary constraints that rely on neutrino free streaming. Our strongest such limit in Λ ⁢CDM, using selected CMB priors, is ∑𝑚 𝜈 < 0.193 eV (95%).

79 ASTRONOMY AND ASTROPHYSICS↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

A round-robin approach provides a detailed assessment of biomolecular small-angle scattering data reproducibility and yields consensus curves for benchmarking

Through an expansive international effort that involved data collection on 12 small-angle X-ray scattering (SAXS) and four small-angle neutron scattering (SANS) instruments, 171 SAXS and 76 SANS measurements for five proteins (ribonuclease A, lysozyme, xylanase, urate oxidase and xylose isomerase) were acquired. From these data, the solvent-subtracted protein scattering profiles were shown to be reproducible, with the caveat that an additive constant adjustment was required to account for small errors in solvent subtraction. Further, the major features of the obtained consensus SAXS data over the q measurement range 0–1 Å −1 are consistent with theoretical prediction. The inherently lower statistical precision for SANS limited the reliably measured q -range to <0.5 Å −1 , but within the limits of experimental uncertainties the major features of the consensus SANS data were also consistent with prediction for all five proteins measured in H 2 O and in D 2 O. Thus, a foundation set of consensus SAS profiles has been obtained for benchmarking scattering-profile prediction from atomic coordinates. Additionally, two sets of SAXS data measured at different facilities to q > 2.2 Å −1 showed good mutual agreement, affirming that this region has interpretable features for structural modelling. SAS measurements with inline size-exclusion chromatography (SEC) proved to be generally superior for eliminating sample heterogeneity, but with unavoidable sample dilution during column elution, while batch SAS data collected at higher concentrations and for longer times provided superior statistical precision. Careful merging of data measured using inline SEC and batch modes, or low- and high-concentration data from batch measurements, was successful in eliminating small amounts of aggregate or interparticle interference from the scattering while providing improved statistical precision overall for the benchmarking data set.

59 BASIC BIOLOGICAL SCIENCES↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

$\gamma$-ray angular correlations, distributions and linear polarization in tracking arrays

With $\gamma $-ray tracking arrays, the angular correlation and, especially, the linear polarization of $\gamma $ rays can be measured with high precision. However, because of the complexity of these spectrometers, measuring angular distributions is more involved. The techniques and associated formalisms were developed and established in the 1950s. The experimental setups of that era were relatively simple when compared to the advanced $\gamma $-ray tracking arrays available today. This paper aims to review and refine these techniques, unify the nomenclatures and, specifically, adapt them for use with the newest tracking arrays. In addition, new methods for producing the required response functions for these arrays are introduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The XLZD Design Book: towards the next-generation liquid xenon observatory for dark matter and neutrino physics

This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chamber technology used in current-generation experiments, LZ and XENONnT. The report discusses the baseline design and opportunities for further optimization of the individual detector components. The experiment envisaged here has the capability to explore parameter space for Weakly Interacting Massive Particle (WIMP) dark matter down to the neutrino fog, with a 3σ evidence potential for WIMP-nucleon cross sections as low as 3 x 10 –49 cm 2 (at 40 GeV/c 2 WIMP mass). The observatory will also have leading sensitivity to a wide range of alternative dark matter models. It is projected to have a 3σ observation potential of neutrinoless double beta decay of 136 Xe at a half-life of up to 5.7 x 10 27 years. Additionally, it is sensitive to astrophysical neutrinos from the sun and galactic supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gap-filled methane and carbon dioxide fluxes across two ecosystem states at the US-OWC AmeriFlux site (2015−2016, 2020−2022)

This dataset contains gap-filled measurements of methane flux (FCH4), net ecosystem CO2 exchange (NEE) partitioned into gross primary productivity (GPP) and ecosystem respiration (RE), as well as latent heat flux (LE) from a Great Lakes coastal freshwater wetland at the US-OWC AmeriFlux site. The dataset covers the peak growing seasons (June−September) of 2015−2016, dominated by Typha spp., and 2020−2022, characterized by floating-leaved species (lotus and water lily). These data were generated to investigate how rising water levels and vegetation shifts influence CH4 and CO2 fluxes across two distinct ecosystem states in this wetland. The dataset, provided in CSV format, includes half-hourly gap-filled flux data from June to September for 2015, 2016, 2020, 2021, and 2022. The gap-filled data refers to measurements where missing values due to instrument issues or quality control were filled using artificial neural networks (ANNs).

54 ENVIRONMENTAL SCIENCES↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

IER 268 CED-3b Report

The goal of IER 268 was to collect information from the operation of the Godiva IV super-prompt critical assembly to support multi-physics modeling efforts. There were two types of systems deployed. One was a Photo-Doppler Velocimetry (PDV) system which used the reflection of laser light on the surface of the Godiva IV core. The other consisted of an MHD 240 detector with two other detectors (an MHD-241 and an Eljen EJ-325A) used for reference as the MHD-240 detector was moved. The collection is referred to as the MHD Detector in the narrative log. There were two types of Godiva operations performed to gather data. A series of super-prompt critical bursts were performed and data collected on both systems, tied to a common trigger. Separately, a series of delayed critical operations at various power levels was performed for a combination of MHD detector distances from Godiva and the presence and absence of a shield in the line of sight between Godiva and the MHD detector. This data was collected to determine the contribution of room return during the burst measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of potential causes of production limiting fouling within SWPF due to mercury solids formation during pH swings within the SWPF process

The Salt Waste Processing Facility (SWPF) goal to investigate the use a high sodium Salt Batch 5 Qualification sample as the radioactive salt solution for mixing tests meant to evaluate the propensity for solids formation between the 5.6 M sodium clarified salt solution (CSS) and scrub solutions (0.05 M HNO 3 and 0.025 M NaOH solutions) during pH changes has been completed at SRNL. The key results and conclusions from this investigation to evaluate the propensity for solids formation between CSS and scrub solutions because of pH fluctuations include the following: None of the 8 test matrices, involving the mixing/titrating of scrub solution with CSS and vice versa, showed any visible evidence for the formation of solids with pH changes. The average turbidity measurements for these 8 tests, excluding test 7, was 21.6 ± 0.4 NTU. This average turbidity value is within 2 sigma of the baseline turbidity value of 20.5 NTU for the CSS only without added scrub solutions. However, only in test 7, which involved the titrating of CSS into dilute nitric acid scrub solution (0.05 M HNO 3 solution), was a small measurable change in the turbidity of the mixture observed at 31.9 ºC. On the other hand, the equivalent test (instantaneous addition of CSS into 0.05 M HNO 3 ) gave an average turbidity measurement value of 21.6 ± 0.6 NTU at a temperature of 24.0 ºC. This difference in turbidity measurement has been attributed to either instrument performance errors or the effect of temperature. It is recommended that these CSS and scrub solution mixing tests be performed with corresponding simulant solutions in a non-radioactive environment. A simulant environment will aid in the full integration of a pH and turbidity meter equipment with the experimental set up. A new detection method, preferable a laser-based method, may be needed in detecting and confirming the precipitation of fine particulates at the right blending times and pH fluctuations in the solution mixtures. On the other hand, the differing free OH concentrations (~2 M in CSS), H + concentrations (0.05 M HNO 3 ) for the titrants and the bulk solutions, may make it almost impossible to observe a neutral pH or a pH in the range of 7-9, where the potential for solids formation is maximized and leads to possible precipitation of minerals like aluminum hydroxides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MOSAiC Radar b1 Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) user facility deployed many instruments on board a German ice breaker, the Research Vessel (RV) Polarstern, for one year from October 2019 to October 2020. The purpose of the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign was to study the decline in the sea-ice pack around the North Pole, and what factors may be at play. After the campaign ended, efforts were undertaken to provide a calibrated radar data set for future studies. MOSAiC presented new challenges to this process, as existing methodologies often were not applicable for the frozen environment with little to no ground clutter, and concurrent engineering updates or calibrations could not be accomplished once the ship set off. Like the previous Cloud, Aerosol, and Complex Terrain Interactions (CACTI) and Cold-air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) documentation (Hardin et al. 2020, Matthews et al. 2023), the data correction and calibration process is known in ARM as creating a “b1” datastream. This means that the radar datastreams have been well characterized to the best possible quality. This report will detail the status of the raw “a1” level data sets during the MOSAiC campaign, the corrections that were applied to create the “b1” data files, and the details of the applied methods.

54 ENVIRONMENTAL SCIENCES↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

Plant Disease Detection Technology Assessment

Visual inspections by US Customs and Border Protection agriculture specialists have identified approximately 20,000 regulated, quarantined pests each year in agricultural products entering the United States. Most of these pests identified in the Agriculture Quarantine and Inspection (AQI) program are insects. Many pathogens are difficult to detect in agricultural products, particularly in early stages of infection. New technologies can help to detect plant pathogens and the diseases that they cause. This technology assessment was performed for the US Department of Homeland Security Science and Technology Directorate (DHS S&T) through the Food, Agriculture, and Veterinary Defense (FAV-D) program to identify emerging technologies that could address this hard problem. These emerging technologies differ in their diagnostic sensitivities and specificities, as well as in their measurement time and training requirements. New instruments that detect volatile organic compounds characteristic of plant disease or pathogens could provide a less invasive inspection method. Dogs, which can successfully detect many concealed agricultural products, have also been trained to detect some plant pests and pathogens. Simple immunological tests offer sensitive and specific detection of many pathogens at the point of use. Advanced imaging methods that use AI to sort fruits and vegetables and recognize anomalies at high speeds could be used in cooperation with exporters to improve food quality and reduce pests. Advances in nucleic acid–based detection methods that have become gold standards for confirmatory diagnostics are now making those methods available for faster, point-of-use detection. These new methods should be developed in the context of AQI operational requirements, which apply risk-based sampling protocols to protect agriculture and facilitate commerce and passenger transit.

59 BASIC BIOLOGICAL SCIENCES↗

Polymer Additive Manufacturing for Marine Renewable Energy Applications: Best Practices, Research Trends, and Current Challenges

Additive manufacturing (AM) is a rapidly growing technology space, not only for prototyping, but is also becoming more feasible at larger scales and increasing component quantities. There are a large variety of AM processes and materials available to users and effectively applying those processes and materials to a specific use case can be challenging. One specific area where AM could be particularly beneficial is marine renewable energy (MRE). Not only is MRE a relatively nascent industry with a near-term need for rapid deployments and prototype testing, but developers could also see long-term benefits from the broad variety of environmentally resistant materials available and the ability to manufacture complex geometries that AM technologies offer. Over the past 4 years, AM materials have played an increasing role in the Advanced Materials project; a multi-year, multi-laboratory research project funded by the U.S. Department of Energy's Water Power Technologies Office, with the main goal of reducing barriers to the adoption of complex materials in the MRE industry. The primary focus of this project is to develop test methods and generate datasets to understand the long-term performance of advanced materials in marine environmental and address specific material challenges as they arise. This report provides an extensive overview of the research that has been performed specific to AM polymers as part of the Advanced Materials project. The intention of this document is to provide recommendations of best practices with regards to material selection, mechanical test method development, and design practices, lessons learned along the way, current research trends, and ongoing challenges with regards to AM polymers in marine environments. In particular, this report focuses on several key aspects: Material and process selection, Environmental conditioning and subsequent degradation quantification through mechanical characterization, Composite reinforcements on AM polymer substrates, Adhesion of instrumentation for mechanical characterization and loads measurements, Protective coatings for preventing biofouling and water ingress, Other MRE case studies where AM has proved particularly useful. Ultimately, we hope that the test methods that have been developed, data generated, and lessons learned from this research will be valuable to the MRE community (researchers and developers alike), as well as other industries, and can be used as a reference point as the respective MRE and AM industries continue to grow and mature.

16 TIDAL AND WAVE POWER↗