Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Capturing the Future: Direct and Indirect Probes of Neutron Capture

This report documents aspects of direct and indirect neutron capture. The importance of neutron capture rates and methods to determine them are presented. The following conclusions are drawn: direct neutron capture measurements remain a backbone of experimental study; work is being done to take increased advantage of indirect methods for neutron capture; both instrumentation and facilities are making new measurements possible; more work is needed on the nuclear theory side to understand what is needed furthest from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AGS vertical beta function measurements for Run 15

One key parameter for running the AGS efficiently is by maintaining a low emittance. To measure emittance, one needs to measure the beta function throughout the cycle. This can be done by measuring the beta function at the ionization profile monitors (IPM) in the AGS. This tech note delves into the motivation, the measurement, and some strides that were made throughout Run15.

43 PARTICLE ACCELERATORS↗

Surrogate Measurements of Actinide (n,2n) Cross Sections with NeutronSTARS

Directly measuring (n,2n) cross sections on short-lived actinides presents a number of experimental challenges. The surrogate reaction technique is an experimental method for measuring cross sections on short-­lived isotopes, and it provides a unique solution for measuring (n,2n) cross sections. This technique involves measuring a charged-­particle reaction cross section, where the reaction populates the same compound nucleus as the reaction of interest. To perform these surrogate (n,2n) cross section measurements, a silicon telescope array has been placed along a beam line at the Texas A&M University Cyclotron Institute, which is surrounded by a large tank of gadolinium-doped liquid scintillator, which acts as a neutron detector. The combination of the charge-particle and neutron-detector arrays is referred to as NeutronSTARS. In the analysis procedure for calculating the (n,2n) cross section, the neutron detection efficiency and time structure plays an important role. Due to the lack of availability of isotropic, mono-energetic neutron sources, modeling is an important component in establishing this efficiency and time structure. This report describes the NeutronSTARS array, which was designed and commissioned during this project. It also describes the surrogate reaction technique, specifically referencing a 235 U(n,2n) commissioning measurement that was fielded during the past year. Advanced multiplicity analysis techniques have been developed for this work, which should allow for efficient analysis of 241 Pu(n,2n) and 239 Pu(n,2n) cross section measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How to measure energy of LEReC electron beam with magnetic spectrometer

For successful cooling the energies of RHIC ion beam and LEReC electron beam must be matched with 10 -4 accuracy. While the energy of ions will be known with required accuracy, e-beam energy can have as large initial offset as 5%. The final setting of e-beam energy will be performed by observing either Schottky spectrum or recombination signal from debunched ions co-traveling with the e-beam. Yet, to start observing such signals one has to set absolute energy of electron beam with accuracy better than 10 -2 , preferably better than 5∙10 -3 . The aim of this exercise is to determine whether and how such accuracy can be reached by utilizing LEReC 180° bend as a spectrometer.

43 PARTICLE ACCELERATORS↗

Experimental Design for Evaluating Selected Nondestructive Measurement Technologies - Advanced Reactor Technology Milestone: M3AT-16PN2301043

The harsh environments in advanced reactors (AdvRx) increase the possibility of degradation of safety-critical passive components, and therefore pose a particular challenge for deployment and extended operation of these concepts. Nondestructive evaluation technologies are an essential element for obtaining information on passive component condition in AdvRx, with the development of sensor technologies for nondestructively inspecting AdvRx passive components identified as a key need. Given the challenges posed by AdvRx environments and the potential needs for reducing the burden posed by periodic in-service inspection of hard-to-access and hard-to-replace components, a viable solution may be provided by online condition monitoring of components. This report identifies the key challenges that will need to be overcome for sensor development in this context, and documents an experimental plan for sensor development, test, and evaluation. The focus of initial research and development is on sodium fast reactors, with the eventual goal of the research being developing the necessary sensor technology, quantifying sensor survivability and long-term measurement reliability for nondestructively inspecting critical components. Materials for sensor development that are likely to withstand the harsh environments are described, along with a status on the fabrication of reference specimens, and the planned approach for design and evaluation of the sensor and measurement technology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Turbine Inflow Characterization at the National Wind Technology Center

Utility-scale wind turbines operate in dynamic flows that can vary significantly over timescales from less than a second to several years. To better understand the inflow to utility-scale turbines, two inflow towers were installed and commissioned at the National Renewable Energy Laboratory's (NREL) National Wind Technology Center near Boulder, Colorado, in 2011. These towers are 135 m tall and instrumented with a combination of sonic anemometers, cup anemometers, wind vanes, and temperature measurements to characterize the inflow wind speed and direction, turbulence, stability and thermal stratification to two utility-scale turbines. Herein, we present variations in mean and turbulent wind parameters with height, atmospheric stability, and as a function of wind direction that could be important for turbine operation as well as persistence of turbine wakes. Wind speed, turbulence intensity, and dissipation are all factors that affect turbine performance. Our results show that these all vary with height across the rotor disk, demonstrating the importance of measuring atmospheric conditions that influence wind turbine performance at multiple heights in the rotor disk, rather than relying on extrapolation from lower levels.

17 WIND ENERGY↗

Measuring System for Use in Radar-System Development

A new system for the analysis and monitoring of radar equipment at the development stage is described. In the verification of radar systems, it is of particular interest to check the reliability of programs that permit the identification of flight test data. In practice, that improves the interpretation of flight data. Practical results are presented.

42 ENGINEERING↗

Production Unit for Fusible Metal Powders

A pilot production unit for fusible metal powders is considered. The formation of liquid metal particles in a melt generator based on the chamber of a low-thrust rocket engine is described. The systems employed in the proposed unit are itemized, including supply systems for the fuel components and initial powder material; the system for flow-rate measurement; the system for collection of the solidifying metal particles; and the system for automated collection and preliminary analysis of the experimental data.

42 ENGINEERING↗

Measurement of the black hole mass in NGC 1332 from ALMA observations at 0.044 arcsecond resolution

We present Atacama Large Millimeter/submillimeter Array (ALMA) Cycle 3 observations of CO(2–1) emission from the circumnuclear disk in the E/S0 galaxy NGC 1332 at 0.″044 resolution. The disk exhibits regular rotational kinematics and central high-velocity emission (±500 km s{sup −1}) consistent with the presence of a compact central mass. We construct models for a thin, dynamically cold disk in the gravitational potential of the host galaxy and black hole and fit the beam-smeared model line profiles directly to the ALMA data cube. Model fits successfully reproduce the disk kinematics out to r = 200 pc. Fitting models just to spatial pixels within projected r = 50 pc of the nucleus (two times larger than the black hole’s gravitational radius of influence), we find M{sub BH}=(6.64{sub −0.63}{sup +0.65})×10{sup 8} M{sub ⊙}. This observation demonstrates ALMA’s powerful capability to determine the masses of supermassive black holes by resolving gas kinematics on small angular scales in galaxy nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

The Braking Index of Millisecond Magnetars

We make the first measurement of the braking index n of two putative millisecond magnetars born in short gamma-ray bursts. We measure n=2.9±0.1 and n=2.6±0.1 for millisecond magnetars born in GRB 130603B and GRB 140903A, respectively. The neutron star born in GRB 130603B has the only known a braking index consistent with the fiducial n = 3 value. This value is ruled out with 99.95% confidence for GRB 140903A. We discuss possible causes of n<3 braking indices in millisecond magnetars, showing that several models can account for the measurement of the braking index in GRB 140903A, while it is more difficult to account for a braking index consistent with n = 3.

79 ASTRONOMY AND ASTROPHYSICS↗

Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

42 ENGINEERING↗

ELECTROMAGNETIC FIELD MEASUREMENT OF FUNDAMENTAL AND HIGHER-ORDER MODES FOR 7-CELL CAVITY OF PETRA-II

The booster synchrotron for NSLS-II will include a 7-cell PETRA cavity, which was manufactured for the PETRA-II project at DESY. The cavity fundamental frequency operates at 500 MHz. In order to verify the impedances of the fundamental and higher-order modes (HOM), which were calculated by computer code, we measured the magnitude of the electromagnetic field of the fundamental acceleration mode and HOM using the bead-pull method. To keep the cavity body temperature constant, we used a chiller system to supply cooling water at 20 degrees C. The bead-pull measurement was automated with a computer. We encountered some issues during the measurement process due to the difficulty in measuring the electromagnetic field magnitude in a multi-cell cavity. We describe the method and apparatus for the field measurement, and the obtained results.

43 PARTICLE ACCELERATORS↗

Uncertainty Analysis on the Design of Thermal Conductivity Measurement by a Guarded Cut-Bar Technique

A technique adapted from the guarded-comparative-longitudinal heat flow method was selected for the measurement of the thermal conductivity of a nuclear fuel compact over a temperature range characteristic of its usage. This technique fulfills the requirement for non-destructive measurement of the composite compact. Although numerous measurement systems have been created based on the guarded comparative method, comprehensive systematic (bias) and measurement (precision) uncertainty associated with this technique have not been fully analyzed. Using finite element modeling, this paper presents the study of two types of error sources in the thermal conductivity measurement process: sample and system geometries and working conditions. The results and conclusions provide valuable reference for designing and operating an experimental measurement system using this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interference Terms for Xenon-135

Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Residence Time Distribution Measurement and Analysis of Pilot-Scale Pretreatment Reactors for Biofuels Production: Preprint

Measurement and analysis of residence time distribution (RTD) data is the focus of this study where data collection methods were developed specifically for the pretreatment reactor environment. Augmented physical sampling and automated online detection methods were developed and applied. Both the measurement techniques themselves and the produced RTD data are presented and discussed.

09 BIOMASS FUELS↗