Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A Deposited Magnetic Thermometer for Temperatures Below 0.1 Kelvin

Magnetic thermometers are less sensitive to self-heating due to rf noise than are traditional resistive thermometers. This makes them appealing at temperatures well below 0.1 Kelvin in the operating range of many space-flight detectors. We have built and tested a magnetic thermometer which is deposited directly onto a substrate. This device, which uses the temperature dependence of iron-doped palladium s magnetic susceptibility, includes self-shielding deposited coils surrounding a sputtered palladium layer. It is read out using a SQUID to achieve high resolution. Its small size and very good heat-sinking should eventually make it useful for the temperature control of space flight detector arrays, in particular those already using SQUID readouts. The design and test results for this device are discussed.

Tuttle, J. G.↗

Artemis III Neutron Surface Science

This paper highlights lunar neutron science that can be performed in support of the Artemis 2024 mission within 6 degrees of the lunar south pole. There are two primary science goals: the characterization of the radiation environment, and secondly, inference of regolith composition including the presence of water. Characterizing the surface radiation environment is important for risk identification and mitigation during crewed lunar missions. The lunar surface radiation environment includes a unique neutron contribution. The relative contribution from neutrons is higher outside the shielding effects of Earth’s magnetic field, which the Moon experiences ~25% of its orbit. To evaluate the radiation risk to astronauts at the lunar surface, fast neutron measurements are needed. Neutrons are generated when galactic cosmic rays (GCR) collide with the lunar regolith and provide valuable elemental composition information about the near surface (< 1m). For the characterization of regolith composition, a low energy neutron spectrometer or counter can determine surface composition. This provides ground truth for orbital neutron data from the Lunar Reconnaissance Orbiter and Lunar Prospector missions.

Lunar science, Moon, geology, geophysics, neutron ↗

Neutron measurements at the Lunar surface with PRISM

Neutron measurements at the lunar surface are performed with two goals: characterization of the radiation environment and inference of regolith composition. This submission is focused on quantifying the surface radiation environment to inform mission design and risk mitigation prior to crewed lunar missions. The lunar surface radiation environment includes a unique neutron contribution. MSFC’s Advanced Neutron Spectrometer for Lunar Surface Measurements instrument covers the most biologically significant energies from thermal to ~20 MeV. The ANSLSM is based on heritage from the Fast Neutron Spectrometer that has measured the ISS crew neutron exposure for the past 3 years, and revealed the significant neutron contribution to total exposure. The relative contribution from neutrons will increase outside the shielding effects of Earth’s magnetic field. To evaluate the radiation risk to astronauts at the lunar surface, precursor fast neutron measurements are needed.

Lunar science, Moon, geology, geophysics, neutron ↗

Magnetohydrodynamic simulations preliminarily predict the habitability and radio emission of TRAPPIST-1e

TRAPPIST-1e, an Earth-sized exoplanet in the habitable zone of the nearby M dwarf TRAPPIST-1, may experience magnetospheric responses that vary with stellar space weather, which could potentially influence both its habitability and radio emissions. Our objective is to investigate how different Earth-like magnetospheric configurations of TRAPPIST-1e – specifically variations in dipolar magnetic field strength and axial tilt – respond to diverse stellar space weather conditions, including events analogous to coronal mass ejections (CMEs), and to assess their implications for potential habitability and expected radio emissions. We conducted 3D magnetohydrodynamic simulations of the TRAPPIST-1e system using the PLUTO code in spherical coordinates. The planetary magnetic field was modelled as dipolar, with equatorial strengths from Earth-like to several times stronger. The dipole axis spans a representative range of axial tilts. We investigate four stellar wind environments, from sub-Alfvénic flow to CME-like disturbances. Planetary shielding was quantified based on the magnetopause standoff distance, and radio powers were estimated via empirical scaling laws. Our simulations show that both shielding and radio power depend strongly on the magnetic configuration. Stronger fields increase protection, while larger tilts reduce it. Radio power increases with both field strength and tilt across all wind regimes. An Earth-like magnetic field can provide effective shielding even under intense CMEs, whereas high tilts require stronger fields. Predicted radio powers reach ~10 20 erg s −1 during CMEs, making bursts from close-in, magnetised planets more detectable. However, for TRAPPIST-1e, the maximum cyclotron frequency lies below the Earth’s ionospheric cutoff (~10 MHz), making ground-based detection currently infeasible.

Sun: magnetic fields↗

Radiation Shielding Calculations for E1039 Seaquest Experiment

The E1039 Seaquest experiment is designed to study results of interactions of the 120 GeV proton beam, delivered from Main Injector, with transversely polarized hydrogen target in the form of liquid ammonia (NH3). The E1039 experiment is re-using the Neutrino-Muon beamline, spectrometer magnet (FMAG), KMAG, and other hardware from its predecessor—the E906 experiment. Only the central 2 Tesla magnetic field was modeled in the FMAG magnet which also serves also as a beam absorber. Various updates were performed to the beamline and shielding around the magnet compared to E906 including relocation of the target 3 meters upstream of the front face of FMAG. Further, several updates were performed on the MARS15 model developed previously [1-2] in order to better describe important surrounding areas, in particular the counting room. Several optimization iterations of the shielding design were done and only the final configuration is discussed in this document. The model includes realistically stacked concrete shielding blocks along with airgaps required for piping, ductwork and detectors. The main features of the shielding update can be summarized as follows: (i) additional concrete shielding was added above the magnet to degrade the energy of neutrons to thermal levels; (ii) a new target alcove with the target cryostat inside. These updates are intended to provide increased protection for both normal operation and accident conditions upstream of the target. The Figures 1 thru 3 below describe the MARS15 model in detail as well as an excerpt of the 3D CAD model design which was used to build the MARS15 model.

43 PARTICLE ACCELERATORS↗

Detector Background at Muon Colliders

Physics goals of a Muon Collider (MC) can only be reached with appropriate design of the ring, interaction region (IR), high-field superconducting magnets, machine-detector interface (MDI) and detector. Results of the most recent realistic simulation studies are presented for a 1.5-TeV MC. It is shown that appropriately designed IR and MDI with sophisticated shielding in the detector have a potential to substantially suppress the background rates in the MC detector. The main characteristics of backgrounds are studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DNA fragmentation induced by Fe ions in human cells: shielding influence on spatially correlated damage

Outside the magnetic field of the Earth, high energy heavy ions constitute a relevant part of the biologically significant dose to astronauts during the very long travels through space. The typical pattern of energy deposition in the matter by heavy ions on the microscopic scale is believed to produce spatially correlated damage in the DNA which is critical for radiobiological effects. We have investigated the influence of a lucite shielding on the initial production of very small DNA fragments in human fibroblasts irradiated with 1 GeV/u iron (Fe) ions. We also used gamma rays as reference radiation. Our results show: (1) a lower effect per incident ion when the shielding is used; (2) an higher DNA Double Strand Breaks (DSB) induction by Fe ions than by gamma rays in the size range 1-23 kbp; (3) a non-random DNA DSB induction by Fe ions. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Discipline Radiation Health↗

Changes made on a 2.7-m long superconducting solenoid magnet cryogenic system that allowed the magnet to be kept cold using 4 K pulse tube coolers

Two 2.7-m long solenoid magnets with a cold mass of 1400 kg were fabricated in between 2007 and 2010. The magnet cryostat outside diameter is ∼1.4 meters and the cryostat length is ∼2.73 meters. The magnet warm bore is 0.4 meters. The magnet was designed to be cooled using three 1.5 W two-stage coolers. In both magnets, three coolers could not keep the cryostat filled with liquid helium. The temperatures of the shield and the tops of the HTS leads were too warm. A 140 W single stage cooler was added to magnet 2 to cool the HTS leads, the shield and the cold mass support intercepts. When the magnet 2 was retested in 2010, the net cooling at 4.2 K was −1.5 W with first-stage temperatures of the four coolers at ∼42 K. The tops of the HTS leads were <50 K, but the shield and cold mass support intercepts remained too warm. The solenoid cryostat and shield were modified during 2011 and 2012 to reduce the 4.2 K heat load and increase the cooling. This magnet was tested in 2012, with five 1.5 W two-stage coolers and the single stage cooler. The changes made in the magnet are described in this report. As a result of the cryostat and shield changes, and adding 3.0 W of cooling at 4.2 K, the net 4.2 K cooling changed from −1.6 W to +5.0 W. About half of the change in net cooling to this magnet was due changes that reduced the shield temperature. This report demonstrates the importance of running the shield cold (∼40 K) and reducing the heat loads from all sources on both the shield and the cold mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma torque and nonambipolar transport

Poloidal symmetry breaking in toroidal plasmas causes a damping of poloidal rotation and toroidal symmetry breaking a damping of toroidal rotation. These torques are transmitted by the magnetic field to the outside world. An upper limit exists on the torque that can be transmitted by magnetic asymmetries. This limit is enforced by shielding asymmetries from the plasma, which can be an important effect for toroidal asymmetries. The torque interaction of plasmas with magnetic fields can be either through an anisotropic pressure or by the drive for magnetic islands. The physics of both types of interactions are considered and paradoxical effects are clarified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of Lightning Induced Effects in a Graphite Composite Fairing Structure

Defining the electromagnetic environment inside a graphite composite fairing due to lightning is of interest to spacecraft developers. This paper is the first in a two part series and studies the shielding effectiveness of a graphite composite model fairing using derived equivalent properties. A frequency domain Method of Moments (MoM) model is developed and comparisons are made with shielding test results obtained using a vehicle-like composite fairing. The comparison results show that the analytical models can adequately predict the test results. Both measured and model data indicate that graphite composite fairings provide significant attenuation to magnetic fields as frequency increases. Diffusion effects are also discussed. Part 2 examines the time domain based effects through the development of a loop based induced field testing and a Transmission-Line-Matrix (TLM) model is developed in the time domain to study how the composite fairing affects lightning induced magnetic fields. Comparisons are made with shielding test results obtained using a vehicle-like composite fairing in the time domain. The comparison results show that the analytical models can adequately predict the test and industry results.

Trout, Dawn H.↗

Modeling a ring magnet in ALEGRA

We show here that Sandia's ALEGRA software can be used to model a permanent magnet in 2D and 3D, with accuracy matching that of the open-source commercial software FEMM. This is done by conducting simulations and experimental measurements for a commercial-grade N42 neodymium alloy ring magnet with a measured magnetic field strength of approximately 0.4 T in its immediate vicinity. Transient simulations using ALEGRA and static simulations using FEMM are conducted. Comparisons are made between simulations and measurements, and amongst the simulations, for sample locations in the steady-state magnetic field. The comparisons show that all models capture the data to within 7%. The FEMM and ALEGRA results agree to within approximately 2%. The most accurate solutions in ALEGRA are obtained using quadrilateral or hexahedral elements. In the case where iron shielding disks are included in the magnetized space, ALEGRA simulations are considerably more expensive because of the increased magnetic diffusion time, but FEMM and ALEGRA results are still in agreement. The magnetic field data are portable to other software interfaces using the Exodus file format.

36 MATERIALS SCIENCE↗

Design of 3x3 Focusing Array for Heavy Ion Driver Final Report on CRADA TC-02082-04

This memo presents a design of a 3x3 quadrupole array for HIF. It contains 3 D magnetic field computations of the array build with racetrack coils with and without different shields. It is shown that it is possible to have a low error magnetic field in the cells and shield the stray fields to acceptable levels. The array design seems to be a practical solution to any size array for future multi-beam heavy ion fusion drivers.

42 ENGINEERING↗

A Review of Tungsten Heavy Alloy Utilization in Isotope Transport Containers - 13380

A common requirement for radioisotope transport containers is that they provide both durable and efficient shielding of penetrating gamma radiation. This is the case for transport of both spent nuclear fuel as well as intentionally created radioisotopes for medical or other uses. Tungsten heavy alloy (WHA) provides a unique engineering property set for such shielding - easily surpassing more commonly used lead alloys in both strength and attenuation. This family of alloys contains typically 90-98 wt.% W in combination with transition metals such as Ni and Fe. WHA is manufactured in near net shape blanks by liquid phase sintering of compacted powder shapes to full metallurgical density parts. This powder metallurgy approach is described in its ability to provide excellent material utilization and affords efficient manufacturing of various shapes required for gamma shields or collimators. WHAs offer very high density (approaching 19 g/cc) in combination with relatively high thermal conductivity, low thermal expansion, ambient corrosion resistance, and can be provided with mechanical properties comparable to many medium carbon steels. As such, they can be machined to complex, damage resistant geometries using common metal cutting tools and methods. WHA additionally provides a lower toxicity alternative to Pb- or U-based gamma shielding. Given the specialty nature of WHA, specific metallurgical characteristics are reviewed to assist shielding designers who may otherwise encounter difficulties locating important alloy selection and fabrication details. Contained within this materials and applications overview are guidelines for WHA component design, alloy selection, and practical machining, finishing, and assembly considerations. The microstructure of WHA is that of a metal matrix composite. This factor has specific implications in the design of components for stress service as well as their protection in the presence of electrolytes. WHA is also discussed in the broader context of materials compatibility, as it is rarely used in isolated monolithic shapes. Alloy selection for new applications is often made primarily on the basis of density. An alternative strategy to this selection approach is presented which proposes that mechanical requirements for a given shielding use be the primary selection criterion over density. Standard commercial grades of WHA for radiation shielding are defined by specifications such as AMS-T-21014 and ASTM B777. These specifications define 4 density classes of as-sintered WHA. Compositional options, as well as post-sinter processing of WHA, are discussed for shielding components that must exhibit higher levels of ductility or very low magnetic permeability. In addition to the mechanical advantages over Pb-based shielding, the higher linear attenuation of energetic photons for various grades of WHA (as calculated by the NIST XCOM routine) are presented for selected photon energies of interest to illustrate the shield volume reduction generally possible through the use of tungsten-based shielding. While W provides inefficient attenuation of neutrons in a mixed radiation environment, its secondary role in shielding gamma radiation produced as a result of neutron capture is also described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Studies of single-photoelectron response and of performance in magnetic field of a H8500C-03 photomultiplier tube

We studied the single-photoelectron detection capabilities of a multianode photomultiplier tube H8500C-03 and its performance in high magnetic field. Our results show that the device can readily resolve signals at the single photoelectron level making it suitable for photon detection in both threshold and ring imaging Cherenkov detectors. We also found that a large longitudinal magnetic field, up to 300 Gauss, induces a change in the relative output of at most 55% for an edge pixel, and of at most 15% for a central pixel. The H8500C-03 signal loss in transverse magnetic fields it is significantly more pronounced than for the longitudinal case. Our studies of single photoelectron reduction in magnetic fields point to the field induced misfocusing of the photoelectron extracted from the photocathode as primary cause of signal loss. With appropriate shielding this PMT could function in high magnetic field environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(abstract) Electromagnetic Compatability Program to Accommodate a Spacecraft Magnetic Search Coil Experiment

A search coil is a very sensitive instrument that measures low frequency magnetic field radiation. In order for the search coil to achieve its objectives, an electromagnetic clean environment must be provided. On a spacecraft, there are many potential sources of low frequency magnetic field emitter. Consequently, a very stringent program is needed to control the emission from these sources. This paper describes the details of such a program.

systems electric motors enclosures shielding↗

The vertical filamentary structures of quiescent prominences

The thin vertical filaments making up the quiescent prominence plasma, as revealed by fine spatial resolution H-alpha photographs, are characterized by a magnetostatic theory in which a horizontal row of long vertical filaments whose weights are supported by bowed magnetic field lines is described by a class of exact equilibrium solutions. The Kippenhahn-Schlueter (1957) solution for a long sheet without filamentary structures is a member of this class of solutions. In illustrating the role of the magnetic field in supporting and thermally shielding the filament plasma, it is found that the filament can have a sharp transition perpendicular to the local field, while the transition in the direction of the local field is diffuse. A consequence of the filamentary structure is that its support by the Lorentz force requires the electric current to have a component along the magnetic field.

Low, B. C.↗

A linearly controlled direct-current power source for high-current inductive loads in a magnetic suspension wind tunnel

The NASA Langley 6 inch magnetic suspension and balance system (MSBS) requires an independently controlled bidirectional DC power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance coupled thyratron controlled rectifiers as well as AC to DC motor generator converters, is obsolete, inefficient, and unreliable. A replacement six phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full load efficiency is 80 percent compared to 25 percent for the resistance coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20 kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

Tripp, John S.↗

A solid-state controllable power supply for a magnetic suspension wind tunnel

The NASA Langley 6-inch Magnetic Suspension and Balance System (6-in. MSBS) requires an independently controlled bidirectional dc power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance-coupled thyratron-controlled rectifiers as well as ac to dc motor-generator converters, is obsolete, inefficient, and unreliable. A replacement six-phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full-load efficiency is 80 percent compared with 25 percent for the resistance-coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20-kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

Daniels, Taumi S.↗