ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mu2e Solenoid Cold Mass Position Monitor System

The Mu2e experiment at Fermilab is designed to search for charged-lepton flavor violation by looking for muon to electron conversions in the field of the nucleus. The concept of the experiment is to generate a low momentum muon beam, stopping the muons in a target and measuring the momentum of the outgoing electrons. The implementation of this approach utilizes a complex magnetic field composed of graded solenoidal and toroidal fields. The location of the solenoid cold mass relative to external fiducials is needed for alignment as well as monitoring coil movements during cool down and magnet excitation. This study describes a novel design of a Cold Mass Position Monitor System (CMPS) that will be implemented for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

W7-X magnetic diagnostics: Rogowski coil performance for very long pulses

Stellerators can be operated without the need of significant plasma current for generation of poloidal magnetic field components. Wendelstein 7-X (W7-X) is optimized for stiff magnetic configurations by minimizing pressure driven currents, such as bootstrap and Pfirsch-Schlueter currents. In Addition to the largely reduced plasma currents, the HELIAS-type device is a low magnetic shear configuration required for magnetic boundary islands. However, the diverting magnetic field structure is already influenced by small net plasma currents. In particular, the W7-AS divertor results revealed a significant sensitivity of the X-point location with respect to favorable edge plasma states. Thus, a precise X-point control for W7-X is envisaged and, although expected net plasma currents range in the order of 10-100 kA only, stabilization by adaptive controllers is foreseen to an accuracy of about 1 kA. This stabilization should be reliable even after 2000 s of plasma operation. A precondition for achieving this is a reliable current detection. For this purpose, W7-X will be equipped with Rogowski of which the first has now been assembled onto one of the plasma vessel sectors. The integral performance and sensitivity inhomogeneities have been tested by employing the digital integrator of W7-X [A. Werner, Rev. Sci. Instrum. 77, 10E307 (2006)] and a cable energized with 200 A, representing the plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fielding the magnetically applied pressure-shear technique on the Z accelerator (completion report for MRT 4519).

The recently developed Magnetically Applied Pressure-Shear (MAPS) experimental technique to measure material shear strength at high pressures on magneto-hydrodynamic (MHD) drive pulsed power platforms was fielded on August 16, 2013 on shot Z2544 utilizing hardware set A0283A. Several technical and engineering challenges were overcome in the process leading to the attempt to measure the dynamic strength of NNSA Ta at 50 GPa. The MAPS technique relies on the ability to apply an external magnetic field properly aligned and time correlated with the MHD pulse. The load design had to be modified to accommodate the external field coils and additional support was required to manage stresses from the pulsed magnets. Further, this represents the first time transverse velocity interferometry has been applied to diagnose a shot at Z. All subsystems performed well with only minor issues related to the new feed design which can be easily addressed by modifying the current pulse shape. Despite the success of each new component, the experiment failed to measure strength in the samples due to spallation failure, most likely in the diamond anvils. To address this issue, hydrocode simulations are being used to evaluate a modified design using LiF windows to minimize tension in the diamond and prevent spall. Another option to eliminate the diamond material from the experiment is also being investigated.

Alexander, C. Scott↗

Extending the operational boundaries of RMP-ELM suppression with optimized 3D field control

The use of 3D magnetic fields is one of the promising approaches to control edge localized modes (ELMs), and ITER has plans to utilize a flexible 3D coil set for ELM suppression using 3D fields. This study focuses on optimizing the 3D field spectrum to expand the operational window for n = 1 resonant magnetic perturbation (RMP) ELM suppression in KSTAR. The optimized n = 1 RMP effectively suppresses ELMs throughout the entire H-mode discharge, including the first ELM crash, while avoiding the onset of disruptive locked modes in low-density L-mode plasmas. The predicted suppression window aligns well with experimental data, highlighting the challenges and solutions of using n = 1 RMP at low densities. Moreover, the optimization successfully achieved n = 1 RMP ELM suppression for the first time in ITER-relevant q 95 and shaping conditions, including cases with q95 as low as 3.6, as well as other q 95 and shape configurations. This highlights the importance and utility of 3D coil optimization while emphasizing the potential of long-wavelength low-n RMP, which will be valuable for ex-vessel coils designed to avoid complications of nuclear degradation.

3D magnetic field control↗

Megagauss-level magnetic field production in cm-scale auto-magnetizing helical liners pulsed to 500 kA in 125 ns

We present Auto-magnetizing (AutoMag) liners [Slutz et al., Phys. Plasmas 24, 012704 (2017)] are designed to generate up to 100 T of axial magnetic field in the fuel for Magnetized Liner Inertial Fusion [Slutz et al., Phys. Plasmas 17, 056303 (2010)] without the need for external field coils. AutoMag liners (cylindrical tubes) are composed of discrete metallic helical conduction paths separated by electrically insulating material. Initially, helical current in the AutoMag liner produces internal axial magnetic field during a long (100 to 300 ns) current prepulse with an average current rise rate dI/dt=5 kA/ns. After the cold fuel is magnetized, a rapidly rising current (200 kA/ns) generates a calculated electric field of 64 MV/m between the helices. Such field is sufficient to force dielectric breakdown of the insulating material after which liner current is reoriented from helical to predominantly axial which ceases the AutoMag axial magnetic field production mechanism and the z-pinch liner implodes. Proof of concept experiments have been executed on the Mykonos linear transformer driver to measure the axial field produced by a variety of AutoMag liners and to evaluate what physical processes drive dielectric breakdown. Lastly, a range of field strengths have been generated in various cm-scale liners in agreement with magnetic transient simulations including a measured field above 90 T at I = 350 kA. By varying the helical pitch angle, insulator material, and insulator geometry, favorable liner designs have been identified for which breakdown occurs under predictable and reproducible field conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Resonance Imaging Protocol Optimization for Delineation of Gross Tumor Volume in Hypopharyngeal and Laryngeal Tumors

Purpose: To optimize the use of MRI for delineation of gross tumor volume for radiotherapy treatment planning purposes in hypopharyngeal and laryngeal tumors. Methods and Materials: Magnetic resonance images (T1 weighted and T2 weighted) of a healthy volunteer were acquired using a 1.5 T and 3.0 T MR scanner. Various receiver coils were investigated that were compatible with the immobilization mask needed for reliable coregistration with computed tomography data. For the optimal receiver coil, the influence of resolution, slice thickness, and strength of magnetic field on the signal-to-noise ratio (SNR) was studied. Feasibility of the definitive protocol was tested on patients with hypopharyngeal (n = 19) and laryngeal (n = 42) carcinoma. Results: Large differences in SNR were obtained for the various coils. The SNR values obtained using surface coils that were compatible with the immobilization mask were three times higher than those obtained using a standard head-and-neck coil and five times higher than those obtained using a body coil. High-resolution images (0.4 x 0.4 x 4 mm{sup 3}) showed superior anatomic detail and resulted in a 4-min scan time. Image quality at 3.0 T was not significantly better compared with 1.5 T. In 3 patients the MR study could not be performed; for 5 patients images were severely deteriorated by motion artefacts. High-quality MR images were obtained in 53 patients. Conclusions: High-resolution MR images of the hypopharynx and larynx can be obtained in the majority of patients using surface receiver coils in combination with the radiotherapy mask. These MR images can be successfully used for tumor delineation in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical design and analysis of an eight-pole superconducting vector magnet for soft x-ray magnetic dichroism measurements

An eight-pole superconducting magnet is being developed for soft x-ray magnetic dichroism (XMD) experiments at the Advanced Light Source, Lawrence Berkley National Laboratory (LBNL). Eight conical Nb{sub 3}Sn coils with Holmium poles are arranged in octahedral symmetry to form four dipole pairs that provide magnetic fields of up to 5 T in any direction relative to the incoming x-ray beam. The dimensions of the magnet yoke as well as pole taper, diameter, and length were optimized for maximum peak field in the magnet center using the software package TOSCA. The structural analysis of the magnet is performed using ANSYS with the coil properties derived using a numerical homogenization scheme. It is found that the use of orthotropic material properties for the coil has an important influence in the design of the magnet.

42 ENGINEERING↗

Optimizing multi-modal, non-axisymmetric plasma response metrics with additional coil rows on DIII-D

The expansion of the DIII-D tokamak operational space via the addition of new non-axisymmetric coil rows is investigated using the linear MHD plasma response code MARS-F. The plasma response to magnetic perturbations imposed by five distinct low- and high-field side coil geometries is modeled for toroidal mode numbers up to n = 6. A set of linear (~δB^2: resonant, kink mode amplitude) and quadratic (~δB: core and edge integrated NTV torque) plasma metrics are defined and compared directly for the various coil geometries. Coil size is also scanned as a secondary optimization variable. An in-vessel coil located at the low-field side midplane is identified as the most efficient plasma response actuator across all metrics and toroidal mode numbers. The multi-row combination of this new midplane (M) coil with the existing DIII-D non-axisymmetric coil set is considered in numerical optimization studies to quantify the impact of this new coil on modeled plasma response metrics. The addition of the M coil is shown to significantly increase the actuator efficiency in maximizing individual plasma response metrics as well as maximizing multi-modal ratios of response metrics, e.g. maximizing resonant modes or edge NTV torque while minimizing kink modes or core NTV torque. The ex-vessel midplane (C) coil is also observed to have an outsize effect on multi-modal optimization due to its uniquely narrow poloidal spectra, and the expansion of optimization space due to the combined use of the two existing in-vessel coil rows with both the M and C coils is notably larger than either coil's individual contribution even though both share similar poloidal locations. This four-row system is expected to greatly extend abilities to understand and optimize the control of transients and rotation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wall scanning probe for high-field side plasma measurements on Alcator C-Mod

A new, high-field side scanning probe has been added to Alcator C-Mod's complement of edge diagnostics. The wall scanning probe is designed to provide all the benefits of a linear plunge, multielectrode scanning probe while working from the confined space of the inner tokamak wall. The drive mechanism is an embedded coil which produces a torque with the ambient toroidal magnetic field when energized, thus allowing the probe to plunge to different preprogramed depths at different times during a plasma discharge. The probe tip is designed for easy replacement and is presently configured to operate as a modified, high heat-flux ''Gundestrup-type'' probe with four tungsten electrodes. The probe has demonstrated the ability to obtain cross-field profiles for electron temperature, density, floating potential, and plasma flow information (parallel and perpendicular to B) up to a depth of a few millimiters inside the last-closed flux surface in standard C-Mod discharges. The tungsten-tipped probe has proved very robust and shows little or no damage though it routinely handles surface heat fluxes on the order of 100 MW/m{sup 2} at peak insertion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic and Mechanical Analysis of Bi-2212 Rutherford Cable in a Cos-Theta Sub-Scale Dipole Coil

The U.S. Magnet Development Program (US-MDP) explores high-field accelerator magnets compatible with operational conditions beyond the limits of Nb$_3$Sn technology. The ongoing R&D High-Temperature Superconductors (HTS) suggests using Bi$_2$Sr$_2$CaCu$_2$O$_{8-x}$ (Bi-2212) as superconducting element. Bi-2212 Rutherford cables maintain a high critical current (I$_C$) when exposed to a large external magnetic field. However, Bi-2212 exhibits an oversensitive stress-strain response when subject to large Lorentz forces. This paper reports on the magnetic and mechanical analysis of the Bi-2212 cosine-theta insert being developed at Fermilab for a hybrid magnet composed of two external layers of Nb$_3$Sn and two internal layers of Bi-2212. We performed a FEM analysis of the insert to estimate the HTS stress state in the coil's strands under magnetic and mechanical loads.

43 PARTICLE ACCELERATORS↗

MAGSAT: Vector magnetometer absolute sensor alignment determination

A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

Acuna, M. H.↗

A new ductile, tougher resin for impregnation of superconducting magnets

A major remaining challenge for Nb 3 Sn high field magnets is their training due to random temperature variations in the coils. The main objective of our research is to reduce or eliminate it by finding novel impregnation materials in replacement of the epoxies currently used. An organic olefin-based thermosetting dicyclopentadiene resin, C 10 H 12 , commercially available in Japan as TELENE® by RIMTEC, was used to impregnate a short Nb 3 Sn undulator coil developed by ANL and FNAL. This magnet reached short sample limit after only two quenches, compared with ∼100 when CTD-101K® was used. Ductility, i.e. the ability to accept large strains, and toughness were identified as key properties to achieve these results. In addition, we have been investigating whether mixing TELENE with high heat capacity ceramic powders such as Gd 2 O 3 , Gd 2 O 2 S, and HoCu 2 , increases the specific heat (C p ) of impregnated Nb3Sn superconducting magnets. The viscosity, heat capacity, thermal conductivity, and other physical properties of TELENE with high-C p powder fillers were measured in this study as a function of temperature and magnetic field. The TELENE-87 wt%Gd 2 O 2 S had a peak in C p between 4.3 K and 5.3 K at fields between 0 and 8 T. We have also investigated the effect on the mechanical properties of pure and mixed TELENE under 10 MGy of gamma ray irradiation at the Takasaki Advanced Radiation Research Institute in Takasaki, Japan. TELENE-87 wt%Gd 2 O 2 S exhibited exceptional radiation resistance. Impregnating an undulator coil with TELENE mixed with Gd 2 O 2 S powder will verify whether the coils' thermal stability further improves, or whether its low diffusivity will require engineering the material with high-thermal conductivity components. Short magnet training will lead to better magnet reliability, lower magnet margins, lower risk and substantial saving in accelerators' commissioning costs. Part of this study is supported by the U.S.-Japan Science and Technology Cooperation Program in high energy physics operated by MEXT in Japan and DOE in the U.S.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-thermal electron acceleration from magnetically driven reconnection in a laboratory plasma

Magnetic reconnection rapidly converts magnetic energy into some combination of plasma flow energy, thermal energy and non-thermal energetic particles. Various reconnection acceleration mechanisms have been theoretically proposed and numerically studied in different collisionless and low-β environments, where β refers to the plasma-to-magnetic pressure ratio. These mechanisms include Fermi acceleration, betatron acceleration, parallel electric field acceleration along magnetic fields and direct acceleration by the reconnection electric field. However, none of them have been experimentally confirmed, as the direct observation of non-thermal particle acceleration in laboratory experiments has been difficult due to short Debye lengths for in situ measurements and short mean free paths for ex situ measurements. Here we report the direct measurement of accelerated non-thermal electrons from magnetically driven reconnection at low β in experiments using a laser-powered capacitor coil platform. We use kilojoule lasers to drive parallel currents to reconnect megagauss-level magnetic fields in a quasi-axisymmetric geometry. The angular dependence of the measured electron energy spectrum and the resulting accelerated energies, supported by particle-in-cell simulations, indicate that the mechanism of direct electric field acceleration by the out-of-plane reconnection electric field is at work. Scaled energies using this mechanism show direct relevance to astrophysical observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The three-dimensional modeling of plasma edge transport and divertor fluxes during application of resonant magnetic perturbations on ITER

Results from three-dimensional modeling of plasma edge transport and plasma–wall interactions during application of resonant magnetic perturbation (RMP) fields for control of edge-localized modes in the ITER standard 15 MA Q = 10 H-mode are presented. The full 3D plasma fluid and kinetic neutral transport code EMC3-EIRENE is used for the modeling. Four characteristic perturbed magnetic topologies are considered and discussed with reference to the axisymmetric case without RMP fields. Two perturbation field amplitudes at full and half of the ITER ELM control coil current capability using the vacuum approximation are compared to a case including a strongly screening plasma response. In addition, a vacuum field case at high q95 = 4.2 featuring increased magnetic shear has been modeled. Formation of a three-dimensional plasma boundary is seen for all four perturbed magnetic topologies. The resonant field amplitudes and the effective radial magnetic field at the separatrix define the shape and extension of the 3D plasma boundary. Opening of the magnetic field lines from inside the separatrix establishes scrape-off layer-like channels of direct parallel particle and heat flux towards the divertor yielding a reduction of the main plasma thermal and particle confinement. This impact on confinement is most accentuated at full RMP current and is strongly reduced when screened RMP fields are considered, as well as for the reduced coil current cases. The divertor fluxes are redirected into a three-dimensional pattern of helical magnetic footprints on the divertor target tiles. At maximum perturbation strength, these fingers stretch out as far as 60 cm across the divertor targets, yielding heat flux spreading and the reduction of peak heat fluxes by 30%. However, at the same time substantial and highly localized heat fluxes reach divertor areas well outside of the axisymmetric heat flux decay profile. Reduced RMP amplitudes due to screening or reduced RMP coil current yield a reduction of the width of the divertor flux spreading to about 20–25 cm and cause increased peak heat fluxes back to values similar to those in the axisymmetric case. The dependencies of these features on the divertor recycling regime and the perpendicular transport assumptions, as well as toroidal averaged effects mimicking rotation of the RMP field, are discussed in the paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat Treatment Optimizations for Wind-and-React Bi-2212 Racetrack Coils

Lawrence Berkeley National Laboratory (LBNL) is developing Wind-and-React (W&R) Bi2sr2cacu2o8+δ (Bi-2212) accelerator magnet technology for insert coils, to surpass the intrinsic limitations of Nb-based magnets, and eventually develop hybrid systems that can approach 20 T dipole fields. The Bi-2212 technology is being developed in close collaboration with industry, and has been partly supported by the US Very High Field Superconducting Magnet Collaboration (VHFSMC). Steady improvements were made over the last several years, with coil HTS-SC08 reaching 2636 A, or about 85% of its witness sample critical current (Ic). Though this is still a factor 3 to 4 too low to be competitive with Nb-based materials, it is expected that the required Ic can be achieved through further conductor optimizations. Recent developments include the commissioning of infrastructure for the reaction of coils at LBNL. Earlier coils were fabricated and tested at LBNL, but were reacted at the wire manufacturer. We describe in detail the furnace calibrations and heat treatment optimizations that enable coil reactions at temperatures approaching 890 °C with a homogeneity of ± 1 °C in a pure oxygen flow. We reacted two new coils at LBNL, and tested the performance of coil HTS-SC10 at 4.2 K in self-field using a superconducting transformer system. We find that its performance is consistent with witness samples, and comparable to coil HTS-SC08, which is an identical coil that was reacted at Oxford Instruments Superconductor Technology (OST), thereby validating the in-house reaction process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tool Chain for Simulations of Bi-Filar Coil Winding for Fast Quench Protection

The advancement of high-field magnets utilizing high-temperature superconductors (HTS) brings about complex challenges, especially in quench detection and protection. Traditional methods often fall short due to the inherently slow quench propagation in HTS materials. One promising approach to overcome this involves using a bifilar winding configuration, where two conductors are placed side by side. Under normal operation, they function in series, but during a quench event, they switch to an anti-parallel mode. This shift reduces the differential inductance of the coil to near zero, enabling rapid current oscillations through a capacitor discharge. The resulting high-frequency current flow leads to swift, uniform heating, triggering a full-coil quench within microseconds. Moreover, the strong mutual coupling between the two windings significantly reduces electrical noise in voltage measurements. In this work, we explore the viability of this concept by designing, constructing, and testing a REBCO bifilar racetrack coil in liquid nitrogen. We also present a validated simulation model that closely mirrors the coil's dynamic behavior under these conditions, aligning well with experimental observations.

Jayathilaka, Rehan [Northern Illinois U.]↗

Measuring the Magnetic Center Behavior of an ILC Superconducting Quadrupole Prototype

The main linacs of the proposed International Linear Collider (ILC) consist of superconducting cavities operated at 2K. The accelerating cavities are contained in a contiguous series of cryogenic modules that also house the main linac quadrupoles, thus the quadrupoles also need to be superconducting. In an early ILC design, these magnets are about 0.6 m long, have cos (2{theta}) coils, and operate at constant field gradients up to 60 T/m. In order to preserve the small beam emittances in the ILC linacs, the e+ and e- beams need to traverse the quadrupoles near their magnetic centers. A quadrupole shunting technique is used to measure the quadrupole alignment with the beams; this process requires the magnetic centers move by no more than about 5 micrometers when their strength is changed. To determine if such tight stability is achievable in a superconducting quadrupole, we at SLAC measured the magnetic center motions in a prototype ILC quadrupole built at CIEMAT in Spain. A rotating coil technique was used with a better than 0.1 micrometer precision in the relative field center position, and less than a 2 micrometer systematic error over 30 minutes. This paper describes the warm-bore cryomodule that houses the quadrupole in its Helium vessel, the magnetic center measurement system, the measured center data and strength and harmonics magnetic data.