Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume↗

Height-resolved emission spectroscopy and high-speed imaging of the TiAl6V4 vapor plume under laser powder bed fusion conditions

Optical emission spectroscopy is increasingly used as an in situ monitoring technique during laser powder bed fusion (LPBF) because plume emission holds elemental information not found in other in situ sensing techniques. This work explores the shape, stability, and temperature of the emission plume above the melt pool of Ti6Al4 V undergoing laser scans under LPBF-like processing conditions, using high-speed video and height-resolved spectroscopy to study the details of plume dynamics. Optical emission spectroscopy is conducted in the 480 nm to 525 nm region, where Ti emission is strong, with 0.3 mm vertical resolution above the baseplate. The Boltzmann plot method is used to determine temperature at each probed elevation, which indicates that the hottest location of the plume is occasionally elevated 0.3 mm to 0.6 mm above the scanning surface. The results show that the plume shape, stability, temperature, and spectra are highly dependent on the processing conditions. We highlight some of the complexities of optical emission spectroscopy and discuss potential challenges for implementing optical emission spectroscopy across an entire build.

36 MATERIALS SCIENCE↗

Autonomous Synthesis of Thin Film Materials with Pulsed Laser Deposition Enabled by In Situ Spectroscopy and Automation

Autonomous systems that combine synthesis, characterization, and artificial intelligence can greatly accelerate the discovery and optimization of materials, however platforms for growth of macroscale thin films by physical vapor deposition techniques have lagged far behind others. Here this study demonstrates autonomous synthesis by pulsed laser deposition (PLD), a highly versatile synthesis technique, in the growth of ultrathin WSe 2 films. Further, by combing the automation of PLD synthesis and in situ diagnostic feedback with a high-throughput methodology, this study demonstrates a workflow and platform which uses Gaussian process regression and Bayesian optimization to autonomously identify growth regimes for WSe 2 films based on Raman spectral criteria by efficiently sampling 0.25% of the chosen 4D parameter space. With throughputs at least 10x faster than traditional PLD workflows, this platform and workflow enables the accelerated discovery and autonomous optimization of the vast number of materials that can be synthesized by PLD.

36 MATERIALS SCIENCE↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Tandem LA-ICP-MS & LIBS; A New Micro-Analytical Technique for the Measurement of Every Element in the Periodic Table

Laser Ablation ICP-MS (LA-ICP-MS) has been widely accepted as a microanalytical technique for in-situ trace (ppb) elemental analysis on the micron scale in a variety of geologic materials. LA-ICP-MS (single or multi-collector) provides both elemental and isotopic measurements critical for a wide range of geological research by generating a fine grained aerosol (nm scale) during the laser ablation event and delivering that aerosol to the ICP ion source of the mass spectrometer via an inert carrier gas. LA-ICP-MS, however, suffers from limitations in analyzing high ionization potential elements as well as elements subject to atmospheric and argon based interferences. LA-ICP-MS also has limitations in analyzing major elements due to detector saturation. An alternative laser ablation technique, Laser Induced Breakdown Spectroscopy (LIBS), employs an optical spectrometer integrated into the laser ablation system that analyzes the laser induced plasma at the sample surface across the entire optical spectrum for emission lines of every element in the periodic table. Elements that are difficult or impossible to measure with LA-ICP-MS are now possible to analyze with LIBS down to low ppm levels with CCD and/or ICCD detection. We introduce a new laser based technique, “Tandem LA-LIBS”, that combines LA for ICP-MS and LIBS into one integrated laser ablation system. This system has the effect of expanding the elemental coverage and the dynamic range of the laser ablation experiment as measurements from ppb to % level matrix elements can now be analyzed in a single ablation experiment. We present both femtosecond and nanosecond Tandem LA-LIBS quantitative and qualitative data on wide range of geological materials for those elements that are difficult or impossible by traditional LA-ICP-MS techniques such as F, H, O, N, C, S, halogens, etc. We also demonstrate that the simultaneous measurement of trace, minor and major elements are now possible in a single laser ablation experiment with Tandem LA-LIBS technology.

LA-ICP-MS↗

Laser-Induced Plasma as a Method for the Metallic Materials Hardness Estimation: An Alternative Approach

The application of an alternative laser-induced breakdown spectroscopy (LIBS) method based on transversely excited atmospheric (TEA) CO2 laser was investigated for the first time for estimating the hardness of metallic materials. The human eye-safe (TEA) CO2 laser, operating at 10.6 µm, was used for plasma generation. The LIBS spectra were recorded by employing a cost-effective CCD camera for the time-integrated and spatial resolved measurements. The cast iron and aluminum alloys samples with different hardness have been tested. The ratio between the magnesium ionic and neutral lines in LIBS spectra was applied for estimating the material hardness. In addition, the hardness of all samples included in this study was determined using the conventional method for material hardness determination, i.e. Vickers hardness test. The linear dependence of magnesium lines intensity ratio on the sample’s hardness was obtained for both kinds of materials. Profilometric measurements were used to verify that the newly-introduced method is almost nondestructive for the investigated metals. The results obtained in the present work confirmed the potential of using this original LIBS system not only for the fast elemental analysis but also for the direct estimation of the hardness of metals and alloys. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.

36 MATERIALS SCIENCE↗

Volume Measurements of Laser-generated Pits for In Situ Geochronology using KArLE (Potassium-Argon Laser Experiment)

The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.

French, R. A.↗

Effect of initial γ -irradiation on infrared laser ablation of poly(vinyl alcohol) studied by infrared spectroscopy

We report the effect of initial γ-irradiation of poly(vinyl alcohol) (PVA) on the kinetics of polymer ablation under CO 2 laser irradiation was studied using infra-red spectroscopy. The rate of laser ablation rapidly decreases with increasing time of laser ablation up to 10 s. Initial γ-irradiation of a dose up to 100 kGy reduces the rate of the laser ablation, just like the effect of laser exposure. The number of OH and CH groups decrease in PVA both with laser irradiation and with γ-irradiation. The number of OH groups decreases more under laser irradiation. Unsaturated bonds are formed in γ–irradiated PVA on the surface of the crater formed by laser ablation of the polymer that has undergone radiolysis. Increasing the dose of initial γ-irradiation from 100 to 2300 kGy leads to an increase in the intensity of the IR bands of the unsaturated bonds. The number of IR bands in the spectra of the laser ablation crater of PVA does not change with the dose of initial γ-irradiation. A dose of radiolysis of 3500 kGy significantly changes the IR spectra of both the ablation crater and the coating formed from the ablation products. Many bands characteristic for PVA are no longer present and the intensities of bands corresponding to unsaturated bonds are increased. A computational model for loss of water and ketone formation was developed for PVA and PVA including a diol using G3(MP2). The highest activation energy barrier step in the decomposition reaction was formation of the enol species and water was shown to catalyze all decomposition steps.

36 MATERIALS SCIENCE↗

Single photon infrared emission spectroscopy: a study of IR emission from UV laser excited PAHs between 3 and 15 micrometers

Single-photon infrared emission spectroscopy (SPIRES) has been used to measure emission spectra from polycyclic aromatic hydrocarbons (PAHs). A supersonic free-jet expansion has been used to provide emission spectra of rotationally cold and vibrationally excited naphthalene and benzene. Under these conditions, the observed width of the 3.3-micrometers (C-H stretch) band resembles the bandwidths observed in experiments in which emission is observed from naphthalene with higher rotational energy. To obtain complete coverage of IR wavelengths relevant to the unidentified infrared bands (UIRs), UV laser-induced desorption was used to generate gas-phase highly excited PAHs. Lorentzian band shapes were convoluted with the monochromator-slit function in order to determine the widths of PAH emission bands under astrophysically relevant conditions. Bandwidths were also extracted from bands consisting of multiple normal modes blended together. These parameters are grouped according to the functional groups mostly involved in the vibration, and mean bandwidths are obtained. These bandwidths are larger than the widths of the corresponding UIR bands. However, when the comparison is limited to the largest PAHs studied, the bandwidths are slightly smaller than the corresponding UIR bands. These parameters can be used to model emission spectra from PAH cations and cations of larger PAHs, which are better candidate carriers of the UIRs.

Non-NASA Center↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Laer-induced Breakdown Spectroscopy Instrument for Element Analysis of Planetary Surfaces

One of the most fundamental pieces of information about any planetary body is the elemental and mineralogical composition of its surface materials. We are developing an instrument to obtain such data at ranges of up to several hundreds of meters using the technique of Laser-Induced Breakdown Spectroscopy (LIBS). We envision our instrument being used from a spacecraft in close rendezvous with small bodies such as comets and asteroids, or deployed on surface-rover vehicles on large bodies such as Mars and the Moon. The elemental analysis is based on atomic emission spectroscopy of a laser-induced plasma or spark. A pulsed, diode pumped Nd:YAG laser of several hundred millijoules optical energy is used to vaporize and electronically excite the constituent elements of a rock surface remotely located from the laser. Light emitted from the excited plasma is collected and introduced to the entrance slit of a small grating spectrometer. The spectrally dispersed spark light is detected with either a linear photo diode array or area CCD array. When the latter detector is used, the optical and spectrometer components of the LIBS instrument can also be used in a passive imaging mode to collect and integrate reflected sunlight from the same rock surface. Absorption spectral analysis of this reflected light gives mineralogical information that provides a remote geochemical characterization of the rock surface. We performed laboratory calibrations in air and in vacuum on standard rock powders to quantify the LIBS analysis. We performed preliminary field tests using commercially available components to demonstrate remote LIBS analysis of terrestrial rock surfaces at ranges of over 25 m, and we have demonstrated compatibility with a six-wheeled Russian robotic rover vehicle. Based on these results, we believe that all major and most minor elements expected on planetary surfaces can be measured with absolute accuracy of 10-15 percent and much higher relative accuracy. We have performed preliminary systems analysis of a LIBS instrument to evaluate probable mass and power requirements; results of this analysis are summarized.

Blacic, J.↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Lessons from combined experimental and theoretical examination of the FTIR and 2D-IR spectroelectrochemistry of the amide I region of cytochrome c</em

Amide I difference spectroscopy is widely used to investigate protein function and structure changes. In this article, we show that the common approach of assigning features in amide I difference signals to distinct secondary structure elements in many cases may not be justified. Evidence comes from Fourier transform infrared (FTIR) and 2D-IR spectroelectrochemistry of the protein cytochrome c in the amide I range, in combination with computational spectroscopy based on molecular dynamics (MD) simulations. This combination reveals that each secondary structure unit, such as an alpha-helix or a beta-sheet, exhibits broad overlapping contributions, usually spanning a large part of the amide I region, which in the case of difference absorption experiments (such as in FTIR spectroelectrochemistry) may lead to intensity-compensating and even sign-changing contributions. We use cytochrome c as the test case, as this small electron-transferring redox-active protein contains different kinds of secondary structure units. Upon switching its redox-state, the protein exhibits a different charge distribution while largely retaining its structural scaffold. Our theoretical analysis suggests that the change in charge distribution contributes to the spectral changes and that structural changes are small. However, in order to confidently interpret FTIR amide I difference signals in cytochrome c and proteins in general, MD simulations in combination with additional experimental approaches such as isotope labeling, the insertion of infrared labels to selectively probe local structural elements will be required. In case these data are not available, a critical assessment of previous interpretations of protein amide I 1D- and 2D-IR difference spectroscopy data is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution infrared spectroscopy of planetary molecules using diode lasers and Fourier transform spectrometers

Modern observations of infrared molecular lines in planets are performed at spectral resolutions which are as high as those available in the laboratory. Analysis of such data requires laboratory measurements at the highest possible resolution, which also yield accurate line positions and intensities. For planetary purposes the spectrometer must be coupled to sample cells which can be reduced in temperature and varied in pressure. An approach which produces the full range of required molecular line parameters uses a combination of tunable diode lasers and Fourier transform spectrometers (FTS). The FTS provides board spectral coverage and good calibration accuracy, while the diode laser can be used to study those regions which are not resolved by the FTS.

Jennings, Donald E.↗

Elemental mass spectroscopy of remote surfaces from laser-induced plasmas

The elemental mass analysis of laser-produced ions from Al, Cu, Ge, Ag, and a lunar simulant target when irradiated by a 400-mJ, 8-ns, Nd: YAG laser at 1 x 10(exp 9) W/cm(exp 2), is reported. Ions traveled down a 11.1-m evacuated tube to an ion-trap 1-m time-of-flight (TOF) mass spectrometer where an elemental mass spectrum was recorded. The amount of target material removed per laser pulse and the ionization fraction were measured. The ion spatial distribution was measured at 11.1-m distance and found to be near a fourth-power cosine distribution. These results indicate the ability to mass analyze a surface over a distance of many kilometers for lunar and asteroid surface elemental mass analysis by a remote satellite or lunar rover.

Situ, W.↗

Room-Temperature Operation of Index-Coupled Distributed-Feedback 4.75 Micron Quantum Cascade Lasers Fabricated Without Epitaxial Regrowth

The Mars Science Laboratory (MSL) was spin-stabilized during its cruise to Mars. We discuss the effects of spin on the radiometric data and how the orbit determination team dealt with them. Additionally, we will discuss the unplanned benefits of detailed spin modeling including attitude estimation and spacecraft clock correlation.

quantum cascade lasers↗

Using the Potassium-Argon Laser Experiment (KArLE) to Date Ancient, Low-K Chondritic Meteorites

Several laboratories have been investigating the feasibility of in situ K-Ar dating for use in future landing planetary missions. One drawback of these laboratory demonstrations is the insufficient analogy of the analyzed analog samples with expected future targets. We present the results obtained using the K-Ar laser experiment (KArLE) on two old and K-poor chondritic samples, Pułtusk and Hvittis, as better lunar analogs. The KArLE instrument uses laser ablation to vaporize rock samples and quantifies K content by laser-induced breakdown spectroscopy (LIBS), Ar by quadrupole mass spectrometry (QMS), and ablated mass by laser profilometry. We performed 64 laser ablations on the chondrites to measure spots with a range of K 2 O and Ar content and used the data to construct isochrons to determine the chondrite formation age. The KArLE isochron ages on Pułtusk and Hvittis are 5059 ± 892 Ma and 4721 ± 793 Ma, respectively, which is within the uncertainty of published reference ages, and interpreted as the age of their formation. The uncertainty (2σ) on the KArLE ages obtained in this study is better than 20% (18% for Pułtusk and 17% for Hvittis). The precision, which compares our obtained ages to the reference ages, is also better than 20% (11% for Pułtusk and 4% for Hvittis). These results are encouraging for understanding the limits of this technique to measure ancient planetary samples and for guiding future improvements to the instrument.

Fanny Cattani↗