Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOADING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions

Measurements of ash deposition rates were made between the secondary superheater and reheater sections of a 450 MW cyclone-fired lignite boiler as the operational load varied from 33 to 100%. Significant reductions in deposition rates with a decrease in operational load were observed. To uncover the causative mechanisms behind these observations, operational data from the power plant were used to carry out computational fluid dynamic (CFD) simulations of the boiler. After ascertaining that the gas temperatures and velocities at various sections within the boiler were being represented adequately, decoupled simulations of the ash deposition process on the deposit probe were carried out using a finely resolved boundary layer mesh. Fly ash particle size distribution (PSD) and its concentration for the decoupled calculations were determined from stand-alone cyclone barrel simulations. The ash partitioning (mass %) between the fly ash and slag was found to be ~50:50, which was in line with previous field observations, and it did not vary significantly across different cyclone loads. The predicted PSD of the deposit ash was concentrated in the size range 10–30 microns, which was in agreement with cross-sectional images of the deposit obtained from the measurements. At lower loads, sharp variations in the deposition rates were predicted in the gas temperature range 950–1150 K. The particle kinetic energy—particle viscosity-based capture methodology utilized in this study in conjunction with appropriate ash compositions, ash viscosity models and gas temperature estimates can help estimate slagging propensities at different loads reasonably well in these systems.

Krishnamoorthy, Gautham (ORCID:0000000255205092)↗

Lubrication of optimized-design tapered-roller bearings to 2.4 million DN

The performance of 120.65 mm (4.75 in.) bore high speed design, tapered roller bearings was investigated at shaft speeds to 20,000 rpm (2.4 million DN) under combined thrust and radial load. The test bearing design was computer optimized for high speed operation. Temperature distribution bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rates, and lubricant inlet temperature. The high speed design, tapered roller bearing operated successfully at shaft speeds up to 20,000 rpm under heavy thrust and radial loads. Bearing temperatures and heat generation with the high speed design bearing were significantly less than those of a modified standard bearing tested previously. Cup cooling was effective in decreasing the high cup temperatures to levels equal to the cone temperature.

Parker, R. J.↗

Magnetohydrodynamics (MHD) Aerocapture System for Enabling Faster-Larger Planetary Science & Human Exploration Missions

Since our completing the NIAC Phase I NIAC on this Advanced Aerocapture System, NASA Langley Research Center has funded or supported a number of studies and code enhancements through its Center Innovation Fund (CIF) and NASA’s NSTGRO and Internship Programs to mature the analysis capabilities and quantify the merits of the MHD Aerocapture System technology. These efforts have resulted in a plug and play analysis capability for assessing MHD aerocapture system performance for arrival at many planetary bodies of interest. Our efforts have especially focused on the potential mass savings for improving the capacity for science observations at Neptune and Triton. A re-cent Forbes article published “‘Orbital mechanics is probably going to decide for us whether we go to Uranus or Neptune because we need to flyby Jupiter,’ said Kunio Sayanagi at Hampton University, Virginia, who also worked on the Neptune Odyssey proposal…. Exactly when a mission can be sent to Uranus, or Neptune, depends on the relative position of Jupiter, which can help give a spacecraft a gravitational slingshot. That drastically shortens the cruise phase.” [1] Since shortening the cruise phase is important for these science missions, any mass savings enabled by the MHD Aerocapture System could be reallocated to increasing Thermal Protection System mass to allow faster arrival speeds and/or for onboarding additional payloads such as science instruments, batteries, or propellant for conducting more science for longer durations in the desired orbits. The analysis steps and codes for conducting trades and sizing vehicles for aerocapture are as follows: Step 1 is to conduct aeroheating analysis using LAURA of the selected entry vehicle shape to identify locations on the forebody where ionization and flow velocity are sufficient for producing Lo-rentz forces. LAURA is a multiblock structured grid finite-volume CFD solver developed at the NASA Langley Research Center. [2] LAURA has been used for aerothermal analysis support of the entry, de-scent and landing (EDL) phase of interplanetary missions over the last three decades [3-7]. Step 2 is to port the LAURA results into CFDWARP to calcu-late electrical and thermal conductivities of ionized flow for sizing MHD patch system and calculating Lorentz forces needed for controls analysis. CFDWARP is a CFD code that uses advanced nu-merical methods that enable the simulation of the full coupling between the aerodynamics, the magne-tohydrodynamics, and the non-neutral plasma sheaths. CFDWARP has the unique capability to simulate efficiently the non-neutral sheaths (near the electrodes) in coupled form with the quasi-neutral bulk MHD flow [8-11]. Step 3 is to link re-sults from LAURA and CFDWARP into POST2 for calculating entry trajectories and comparing MHD control results with other aerodynamic control strategies. The Program to Optimize Simulated Tra-jectories II (POST2) is a generalized point mass, discrete parameter targeting and optimization pro-gram. POST2 provides the capability to target and optimize point mass trajectories for multiple pow-ered or un-powered vehicles near an arbitrary rotat-ing, oblate planet [12]. Step 4: TPS sizing was per-formed using the Fully Implicit Ablation and Ther-mal-response code (FIAT) tool which computes the transient one-dimensional thermal response and surface thermochemistry of a multilayer stackup of thermal protection, bonding, and structural materi-als subject to aeroheating on one surface [13]. The sizing and margining methodology used was based on the approach documented by Mahzari and Milos [14] for the dual-layered heatshield for extreme entry environment technology (DL-HEEET) TPS concept. TPS analysis utilizes trajectory information from POST2. Using this step-wise plug and play MHD Aerocapture performance assessment process, our analysis targets a Neptune aerocapture trajectory that will place the spacecraft in an observation orbit for Triton. [15]. Magnetohydrodynamic (MHD) control of a 4.5-meter diameter MSL-style capsule resulted in TPS mass savings of nearly 2000 kg when using an MHD system mass of under 200 kg. The flight path for a vehicle using the MHD control strategy has a much lower heat rate and heat load compared to the conventional aerodynamic aerocapture strategies known as bank angle con-trolled (BAC) and direct force controlled (DFC). Both BAC and DFC have heat rates significantly greater than 1500 W/cm2 typically used as an upper limit for PICA. Thus, DL-HEEET TPS concept was required for the BAC and DFC control strategies. However, considering the more benign environ-ments for the MHD case, additional TPS concepts with improved mass efficiency were also assessed. PICA was considered for the MHD controlled strat-egy since the maximum heat rate was well within the limits (<1500 W/cm2) of PICA. TPS sizing re-sulted in a significant mass reduction. The PICA layer for this sizing case was about 7.8 cm. As a point of reference, the Mars 2020 mission, which used this same PICA concept, had a PICA thickness of 3.18 cm [16]. The trajectories used for the TPS sizing originat-ed from the POST2 simulations. The current, I, to an electromagnet configuration can be manipulated to allow for active control of the vehicle. Manipula-tion of the current, I, changes the magnetic field, B, which affects the Lorentz force and therefore the MHD drag force on the vehicle. Our analysis in-cluded both open-loop and close-loop control. Closed-loop control will enable improved overall performance when taking into account mission level uncertainties, such as interplanetary delivery errors and atmospheric modeling uncertainties. The open-loop and closed-loop MHD control cases do not dip as deep into the atmosphere as the aerodynamic cases. Three types of aerodynamic-only approach-es are investigated: bank angle modulation (BAM), director force control (DFC), and Drag Modulated. BAM and DFC make use of vehicle aerodynamic angles to steer the vehicle. Thus, changing the aer-odynamic forces acting on the vehicle for control, aerodynamic drag modulated case requires a vary-ing drag area to modulate the drag force. The MHD drag modulated case modulates MHD generated drag force that adds to the aerodynamic drag. This higher atmospheric activation of drag forces by the MHD patch results in significantly less heat flux on the vehicle. The MHD technology will enable shorter cruise times and deceleration of larger payloads for increasing the capacity for science at the Ice Giants or for returning astronauts to Earth from cislunar space or from Mars. The purpose of this presentation is to provide more details about this work and to highlight plans for further research and development including a flight demonstration.

R. W. Moses↗

OBSERVATIONS AND IMPLICATIONS OF INTERGRANULAR STRESS CORROSION CRACK GROWTH OF ALLOY 152 WELD METALS IN SIMULATED PWR PRIMARY WATER

Significant intergranular (IG) crack growth during stress corrosion cracking (SCC) tests has been documented during tests in simulated PWR primary water on two alloy 152 specimens cut from a weldment produced by ANL. The cracking morphology was observed to change from transgranular (TG) to mixed mode (up to ~60% IG) during gentle cycling and cycle + hold loading conditions. Measured crack growth rates under these conditions often suggested a moderate degree of environmental enhancement consistent with faster growth on grain boundaries. However, overall SCC propagation rates at constant stress intensity (K) or constant load were very low in all cases. Initial SCC rates up to 6x10-9 mm/s were occasionally measured, but constant K/load growth rates dropped below ~1x10-9 mm/s with time even when significant IG engagement existed. Direct comparisons were made among loading conditions, measured crack growth response and cracking morphology during each test to assess IGSCC susceptibility of the alloy 152 specimens. These results were analyzed with respect to our previous SCC crack growth rate measurements on alloy 152/52 welds.

alloy 152, SCC, stress corrosion cracking, intergr↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Counterflow ignition of n-butanol at atmospheric and elevated pressures

Vital to the development of predictive combustion models is a robust understanding of the coupled effects of chemical kinetics and convective–diffusive transport at both atmospheric and elevated pressures. The current study describes a new variable-pressure non-premixed counterflow ignition experiment designed to address the need for well-characterized reference data to validate such models under conditions sensitive to both chemical and transport processes. A comprehensive characterization of system behavior is provided to demonstrate boundary condition and ignition quality as well as adherence to the assumption of quasi-one-dimensionality, and suggest limitations and best practices for counterflow ignition experiments. This effort reveals that the counterflow ignition experiment requires special attention to ignition location in order to ensure that the assumption of quasi-one-dimensionality is valid, particularly at elevated pressures. This experimental tool is then applied to the investigation of n-butanol for pressures of 1–4 atm, pressure-weighted strain rates of 200–400 s -1 , and fuel mole fractions of 0.05–0.25. Results are simulated using two n-butanol models available in the literature and used to validate and assess model performance. Comparison of experimental and numerical ignition results for n-butanol demonstrates that while existing models largely capture the trends observed with varying pressure, strain rate, and fuel loading, the models universally over-predict experimental ignition temperatures. While several transport coefficients are found to exhibit order-of-magnitude or greater sensitivities relative to reaction rates, variation of transport parameters is not able to account for the large deviations observed between experimental and numerical results. Additional comparison of ignition kernel structure and fuel breakdown pathways between two literature models suggests that an under-prediction in the radical pool growth with respect to temperature variation may be responsible for both the deviation from the experimental results and the discrepancy in ignition temperature results observed between models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Engineering and Cost Analysis for DPC Disposal Solutions. Final Draft

There are currently (as of January, 2019) more than 2,700 dual-purpose canisters (DPCs) loaded with spent nuclear fuel (SNF) across the United States. DPCs continue to be loaded at a rate of more than 200 per year by mid-century there are likely to be more than 8,160 DPCs in service. Options for disposing of SNF loaded in DPCs include repackaging into specialized disposal canisters, directly disposing of the loaded DPCs (with or without modification), or some combination of the two. The main technical challenges for direct disposal of loaded DPCs are thermal management, handling and emplacement operations for the large, heavy packages, and postclosure criticality control. This report focuses on postclosure criticality control which is the most challenging. The challenge lies in determining how to modify DPCs so as to minimize the probability that a criticality event might occur in a repository, or if the DPCs are not modified, to understand the nature and consequences of postclosure criticality events. There are several approaches that could facilitate direct disposal of loaded DPCs with acceptable repository performance. This report describes these approaches and presents comparative analysis of the rough-order-of-magnitude (ROM) costs. Repackaging SNF in DPCs into specialized disposal canisters could be financially and operationally costly with additional radiological, operational safety, and management risks. A disposition approach that would not involve repackaging or modifications to DPCs (future or already loaded) is development of a new licensing strategy that addresses the risk (probability and consequence) from criticality events. A different approach would modify existing loaded DPCs (some or all of them), and change the loading or design of future DPCs, to decrease the probability of a criticality event in a repository below levels of concern. This report investigates the cost to modify existing loaded DPCs, and the cost to modify the loading or design of future DPCs to facilitate direct disposal. It establishes the ROM cost for repackaging SNF that has been loaded into DPCs, into specialized canisters for disposal. It also identifies technical and regulatory challenges associated with the potential design modifications and loading considerations. It is left to future analyses to compare radiological, operational safety, and management risks associated with the available approaches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Efficient Two-Way Coupled Analysis of Steady-State Particle-Laden Hypersonic Flows

A direct solution approach for surface erosion in particle-laden hypersonic flows is extended for use in low-cost two-way coupled solutions of dilute gas-particle flows. The Trajectory Control Volume method, which uses a sparse set of probe particles to predict surface erosion distributions on general vehicles, is reformulated for the solution of source terms by mean trajectory subdivision and computing a flux differencing. The approach is verified successfully against a boundary layer solution and shown to agree well with experimental measurements. A representative Mars entry case, with conditions and geometry based on the ExoMars Schiaparelli capsule, is solved with the approach to study the impact of two-way coupling on surface heating and erosion. Results indicate that for realistic loading conditions, heating is largely unmodified compared to one-way coupled results at peak heating trajectory conditions, and no measureable difference is observed in the surface erosion rate. At exaggerated loading conditions high enough to observe coupling effects, the worst case collisional heating can increase heating by up to 60%.

Particle Laden Flow↗

Durability, Performance, and Emission of Diesel Engines Using Carbon Fiber Piston and Liner

This report summarizes the research conducted by NC State University in investigating the durability, performance and emission of a carbon fiber piston and liner in our single cylinder research Diesel engine. Both the piston and liner were supplied to NC State University by NASA LaRC and manufactured by C-CAT under a separate contract to NASA LaRC. The carbon-carbon material used to manufacture the piston and liner has significantly lower thermal conductivity, coefficient of thermal expansion, and superior strength characteristics at elevated temperatures when compared to conventional piston materials such as aluminum. The results of the carbon-carbon fiber piston testing were compared to a baseline configuration, which used a conventional aluminum piston in a steel liner. The parameters measured were the brake specific fuel consumption, ignition delay, frictional horsepower, volumetric efficiency, and durability characteristics of the two pistons. Testing was performed using a naturally aspirated Labeco Direct Injection single cylinder diesel engine. Two test cases were performed over a range of loads and speeds. The fixed test condition between the aluminum and carbon-carbon piston configurations was the brake mean effective pressure. The measured data was the fuel consumption rate, volumetric efficiency, load, speed, cylinder pressure, needle lift, and exhaust gas temperature. The cylinder pressure, and fuel consumption, exhaust gas temperature, and needle lift were recorded using a National Instruments DAQ board and a PC. All test cases used Diesel no. 2 for fuel.

Afify, E. M.↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model: Preprint

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Numerical analysis of flow and heat transfer in the VAFB LOX storage Dewar tank

The present report describes numerical simulation of three-dimensional transient distributions of velocity and temperature of liquid oxygen (LOX) in the LOX Dewar tank of Vendenberg Air Force Base (VAFB). The present analyses cover the replenish time period only. Four test cases have been considered. For all four cases, the input boundary conditions are comprised of LOX facility heat loads, drain flow rates, recirculation flow rates and dewar heating. All the quantities are prescribed as functions of time. The first two test cases considered sensitivity of results to the computational grid. In Case 3, system heat load was changed, while in Case 4, a lower LOX level was specified. Cases 1 and 2 showed that the temperatures were not sensitive to the grid refinement. This provided a basic check on the numerical model. Cases 3 and 4 showed that the thermal boundary layer motion near the tank surface becomes more significant at the late time, e.g., 5 1/2 hours from replenish start. Comparison between results of Cases 3 and 4 showed, as expected, that the smaller initial LOX volume given in Case 4, results in higher temperature level. All calculated velocity and temperature distributions were found to be plausible.

Tam, L. T.↗

Sustained strain applied at high rates drives dynamic tensioning in epithelial cells

Epithelial cells experience long lasting loads of different magnitudes and rates. How they adapt to these loads strongly impacts tissue health. Yet, much remains unknown about the evolution of cellular stress in response to sustained strain. Here, by subjecting cell pairs to sustained strain, we report a bimodal stress response, where in addition to the typically observed stress relaxation, a subset of cells exhibits a dynamic tensioning process with significant elevation in stress within 100 s, resembling active pulling-back in muscle fibers. Strikingly, the fraction of cells exhibiting tensioning increases with increasing strain rate. The tensioning response is accompanied by actin remodeling, and perturbation to actin abrogates it, supporting cell contractility’s role in the response. Collectively, our data show that epithelial cells adjust their tensional states over short timescales in a strain-rate dependent manner to adapt to sustained strains, demonstrating that the active pulling-back behavior could be a common protective mechanism against environmental stress.

bioinformatics↗

Control system design for maintaining CO{sub 2} capture in IGCC power plants while loading-following

Load-following requirements for future integrated gasification combined cycle (IGCC) power plants with precombustion CO{sub 2} capture are expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. In this work, loadfollowing studies are performed using a comprehensive dynamic model of an IGCC plant with pre-combustion CO{sub 2} capture developed in Aspen Engineering Suite (AES). Considering multiple single-loop controllers for power demand load following, the preferred IGCC control strategy from the perspective of a power producer is gas turbine (GT) lead with gasifier follow. In this strategy, the GT controls the load by manipulating its firing rate while the slurry feed flow to the gasifier is manipulated to control the syngas pressure at the GT inlet. The syngas pressure control is an integrating process with significant time delay mainly because of the large piping and equipment volumes between the gasifier and the GT inlet. A modified proportional–integral–derivative (PID) control is considered for IGCC syngas pressure control. The desired CO{sub 2} capture rate must be maintained while the IGCC plant follows the load. For maintaining the desired CO{sub 2} capture rate, the control performance of PID control is compared with linear model predictive control (LMPC). The results show that the LMPC outperforms PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

20 FOSSIL-FUELED POWER PLANTS↗

Thermal dissipation studies and Pu238/Li source simulation (MCNP) of the K2 containers (COWS)

The six K2 containers (COWS) have been proposed to be shipped to WIPP in the configuration depicted in Figure 1. Currently, the containers reside in the water bath storage and have not been opened since LANL received them. The K2 containers containing the mound scrap material each have their own unique dose rate and thermal loading. 3 The properties of each container are listed below in Table 1. The problem with loading the K2 container into the proposed configuration is the thermal load the package will experience. Each component within the package has a thermal working limit that should not be exceeded. 2 However, the package must also maintain enough shielding to lower the measured dose rate at the surface of the drum to be accepted by WIPP. Testing the current configuration through simulation LANL can prove heat will not compromise any components and dose can be reduced to a safe configuration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and test of a pumped two-phase mounting plate

The design, fabrication, and testing of the full-scale development unit of a pumped two-phase mounting plate (TPMP) used in advanced two-phase spacecraft thermal control systems are described. The mounting plate is tested with R-11 in the evaporator mode for total heat loads of over 3000 watts and local heat fluxes over 4 W/sq cm, and in the condenser mode with condenser loads from 60 to 400 watts and inlet qualities from 8 to 94 percent. The calculated heat-transfer coefficients are between 0.66 and 1.0 W/sq cm/C and are nearly independent of the flow rate and heat load except at very low heat loads. It is shown that the TPMP can be run with inlet conditions down to 22 C subcooling without any significant gradients in the plate and that it performs well with nonuniform heat fluxes.

Grote, M. G.↗

Microstructural characterization of Charpy-impact-tested nanostructured bainite

In this work, a possible cause of the extraordinary low impact toughness of nanostructured bainite has been investigated. The microstructure of nanostructured bainite consisted chiefly of carbide-free bainitic ferrite with retained austenite films. X-ray diffractometry (XRD) measurement indicated that no retained austenite existed in the fractured surface of the Charpy-impact-tested specimens. Fractographs showed that cracks propagated mainly along bainitic ferrite platelet boundaries. The change in microstructure after impact loading was verified by transmission electron microscopy (TEM) observations, confirming that retained austenite was completely transformed to strain-induced martensite during the Charpy impact test. However, the zone affected by strained-induced martensite was found to be extremely shallow, only to a depth of several micrometers from the fracture surface. It is appropriately concluded that upon impact, as the crack forms and propagates, strain-induced martensitic transformation immediately occurs ahead of the advancing crack tip. The successive martensitic transformation profoundly facilitates the crack propagation, resulting in the extremely low impact toughness of nanostructured bainite. Retained austenite, in contrast to its well-known beneficial role, has a deteriorating effect on toughness during the course of Charpy impact. - Highlights: • The microstructure of nanostructured bainite consisted of nano-sized bainitic ferrite subunits with retained austenite films. • Special sample preparations for SEM, XRD and TEM were made, and the strain-affected structures have been explored. • Retained austenite films were found to transform into martensite after impact loading, as evidenced by XRD and TEM results. • The zone of strain-induced martensite was found to extend to only several micrometers from the fracture surface. • The poor Charpy impact toughness is associated with the fracture of martensite at a high strain rate during impact loading.

36 MATERIALS SCIENCE↗

ARC algorithm: A novel approach to forecast and manage daily electrical maximum demand

This paper proposes an innovative algorithm for predicting short-term electrical maximum demand by using historical demand data. The ability to recognize in peak demand pattern for commercial or industrial customers would propose numerous direct and indirect benefits to the customers and utility providers in terms of demand reduction, cost control, and system stability. Prior works in electrical maximum demand forecasting have been mainly focused on seasonal effects, which is not a feasible approach for industrial manufacturing facilities in short-term load forecasting. The proposed algorithm, denoted as the Adaptive Rate of Change (ARC), determines the logarithmic rate-of-change in load profile prior to a peak by postulating the demand curve as a stochastic, mean-reverting process. The rationale behind this analysis, is that the energy efficient program requires not only demand estimation but also to warn the user of imminent maximum peak occurrence. This paper analyzes demand trend data and incorporates stochastic model and mean reverting half-life to develop an electrical maximum demand forecasting algorithm, which is statistically evaluated by cross-table and F-score for three different manufacturing facilities. Lastly, the aggregate results show an overall accuracy of 0.91 and a F-score of 0.43, which indicates that the algorithm is effective predicting peak demand in predicting peak demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗