Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Independent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Resource-Efficient Measurement-Device-Independent Entanglement Witness

Imperfections in experimental measurement schemes can lead to falsely identifying, or over estimating, entanglement in a quantum system. A recent solution to this is to define schemes that are robust to measurement imperfections—measurement-device-independent entanglement witness (MDI-EW). This approach can be adapted to witness all entangled qubit states for a wide range of physical systems and does not depend on detection efficiencies or classical communication between devices. In this paper, we extend the theory to remove the necessity of prior knowledge about the two-qubit states to be witnessed. Moreover, we tested this model via a novel experimental implementation for MDI-EW that significantly reduces the experimental complexity. Finally, by applying it to a bipartite Werner state, we demonstrate the robustness of this approach against noise by witnessing entanglement down to an entangled state fraction close to 0.4.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model-Independent Evidence for J / ψ p Contributions to Λ b 0 → J / ψ p K – Decays

The data sample of Λ 0 b → J/ψpK - decays acquired with the LHCb detector from 7 and 8 TeV pp collisions, corresponding to an integrated luminosity of 3 fb -1 , is inspected for the presence of J/ψp or J/ψK - contributions with minimal assumptions about K - p contributions. It is demonstrated at more than nine standard deviations that Λ 0 b → J/ψpK - decays cannot be described with K - p contributions alone, and that J/ψp contributions play a dominant role in this incompatibility. These model-independent results support the previously obtained model-dependent evidence for P + c → J/ψp charmonium-pentaquark states in the same data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature-Independent Nuclear Quantum Effects on the Structure of Water

Nuclear quantum effects (NQEs) have a significant influence on the hydrogen bonds in water and aqueous solutions and have thus been the topic of extensive studies. However, the microscopic origin and the corresponding temperature dependence of NQEs have been elusive and still remain the subject of ongoing discussion. Previous x-ray scattering investigations indicate that NQEs on the structure of water exhibit significant temperature dependence. Here, by performing wide-angle x-ray scattering of H 2 O and D 2 O droplets at temperatures from 275 K down to 240 K, we determine the temperature dependence of NQEs on the structure of water down to the deeply supercooled regime. The data reveal that the magnitude of NQEs on the structure of water is temperature independent, as the structure factor of D 2 O is similar to H 2 O if the temperature is shifted by a constant 5 K, valid from ambient conditions to the deeply supercooled regime. Analysis of the accelerated growth of tetrahedral structures in supercooled H 2 O and D 2 O also shows similar behavior with a clear 5 K shift. The results indicate a constant compensation between NQEs delocalizing the proton in the librational motion away from the bond and in the OH stretch vibrational modes along the bond. In conclusion, this is consistent with the fact that only the vibrational ground state is populated at ambient and supercooled conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of Model-Independent Control of the Longitudinal Phase Space of Electron Beams in the Linac-Coherent Light Source with Femtosecond Resolution

The dynamics of intense electron bunches in free electron lasers and plasma wakefield accelerators are dominated by complex collective effects such as wakefields, space charge, coherent synchrotron radiation, and drift unpredictably with time, making it difficult to control and tune beam properties using model-based approaches. Here in this paper we report on a first of its kind combination of automatic, model-independent feedback with a neural network for control of the longitudinal phase space of relativistic electron beams with femtosecond resolution based only on transverse deflecting cavity measurements.

43 PARTICLE ACCELERATORS↗

Evidence for Rigid Triaxial Deformation in Ge 76 from a Model-Independent Analysis

An extensive, model-independent analysis of the nature of triaxial deformation in 76 Ge, a candidate for neutrinoless double-beta (0νββ) decay, was carried out following multistep Coulomb excitation. Shape parameters deduced on the basis of a rotational-invariant sum-rule analysis provided considerable insight into the underlying collectivity of the ground-state and γ bands. Both sequences were determined to be characterized by the same β and γ deformation parameter values. In addition, compelling evidence for low-spin, rigid triaxial deformation in 76 Ge was obtained for the first time from the analysis of the statistical fluctuations of the quadrupole asymmetry deduced from the measured E 2 matrix elements. Furthermore, these newly determined shape parameters are important input and constraints for calculations aimed at providing, with suitable accuracy, the nuclear matrix elements relevant to 0νββ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration of Machine Learning-Based Model-Independent Stabilization of Source Properties in Synchrotron Light Sources

Synchrotron light sources, arguably among the most powerful tools of modern scientific discovery, are presently undergoing a major transformation to provide orders of magnitude higher brightness and transverse coherence enabling the most demanding experiments. In these experiments, overall source stability will soon be limited by achievable levels of electron beam size stability, presently on the order of several microns, which is still 1–2 orders of magnitude larger than already demonstrated stability of source position and current. Until now source size stabilization has been achieved through corrections based on a combination of static predetermined physics models and lengthy calibration measurements, periodically repeated to counteract drift in the accelerator and instrumentation. In this paper, we now demonstrate for the first time how the application of machine learning allows for a physics- and model-independent stabilization of source size relying only on previously existing instrumentation. Such feed-forward correction based on a neural network that can be continuously online retrained achieves source size stability as low as 0.2 μm (0.4%) rms, which results in overall source stability approaching the subpercent noise floor of the most sensitive experiments.

43 PARTICLE ACCELERATORS↗

Model-Independent Study of Structure in B + → D + D - K + Decays

The only anticipated resonant contributions to B + → D + D - K + decays are charmonium states in the D + D - channel. A model-independent analysis, using LHCb proton-proton collision data taken at center of-mass energies of $\sqrt{s}$ = 7, 8, and 13 TeV, corresponding to a total integrated luminosity of 9 fb -1 , is carried out to test this hypothesis. The description of the data assuming that resonances only manifest in decays to the D + D - pair is shown to be incomplete. This constitutes evidence for a new contribution to the decay, potentially one or more new charm-strange resonances in the D + K - channel with masses around 2.9 GeV/c 2

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model-Independent Determination of Nuclear Weak Form Factors and Implications for Standard Model Precision Tests

We analyze the recoil corrections in superallowed beta decays of T = 1, J P = 0 + nuclei by fixing the mean square charged weak radius model independently using the data of multiple charge radii across the nuclear isotriplet. By comparing to model estimations, we argue that the existing theory uncertainty in the statistical rate function f might have been substantially underestimated. Here, we discuss the implications of our proposed strategy for precision tests of the standard model, including a potential alleviation of the first-row CKM unitarity deficit, and motivate new experiments for charge radii measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SIMBAD : a sequence-independent molecular-replacement pipeline

The conventional approach to finding structurally similar search models for use in molecular replacement (MR) is to use the sequence of the target to search against those of a set of known structures. Sequence similarity often correlates with structure similarity. Given sufficient similarity, a known structure correctly positioned in the target cell by the MR process can provide an approximation to the unknown phases of the target. An alternative approach to identifying homologous structures suitable for MR is to exploit the measured data directly, comparing the lattice parameters or the experimentally derived structure-factor amplitudes with those of known structures. Here, SIMBAD , a new sequence-independent MR pipeline which implements these approaches, is presented. SIMBAD can identify cases of contaminant crystallization and other mishaps such as mistaken identity (swapped crystallization trays), as well as solving unsequenced targets and providing a brute-force approach where sequence-dependent search-model identification may be nontrivial, for example because of conformational diversity among identifiable homologues. The program implements a three-step pipeline to efficiently identify a suitable search model in a database of known structures. The first step performs a lattice-parameter search against the entire Protein Data Bank (PDB), rapidly determining whether or not a homologue exists in the same crystal form. The second step is designed to screen the target data for the presence of a crystallized contaminant, a not uncommon occurrence in macromolecular crystallography. Solving structures with MR in such cases can remain problematic for many years, since the search models, which are assumed to be similar to the structure of interest, are not necessarily related to the structures that have actually crystallized. To cater for this eventuality, SIMBAD rapidly screens the data against a database of known contaminant structures. Where the first two steps fail to yield a solution, a final step in SIMBAD can be invoked to perform a brute-force search of a nonredundant PDB database provided by the MoRDa MR software. Through early-access usage of SIMBAD , this approach has solved novel cases that have otherwise proved difficult to solve.

59 BASIC BIOLOGICAL SCIENCES↗

Synchronous I/O Scheduling of Independent Write Caches for an Array of SSDs

Solid-state drives (SSD) offer a significant performance improvement over the hard disk drives (HDD), however, it can exhibit a significant variance in latency and throughput due to internal garbage collection (GC) process on the SSD. When the SSDs are configured in a RAID, the performance variance of individual SSDs could significantly degrade the overall performance of the RAID of SSDs. The internal cache on the RAID controller can help mitigate the performance variability issues of SSDs in the array; however, the state-of-the-art cache algorithm of the RAID controller does not consider the characteristics of SSDs. In this paper, we examine the most recent write cache algorithm for the array of disks, and propose a synchronous independent write cache (SIW) algorithm. We also present a pre-parity-computation technique for the RAID of SSDs with parity computations, which calculates parities of blocks in advance before they are stored in the write cache. With this new technique, we propose a complete paradigm shift in the design of write cache. In our evaluation study, large write requests dominant workloads show up to about 50 and 20 percent improvements in average response times on RAID-0 and RAID-5 respectively as compared to the state-of-the-art write cache algorithm.

97 MATHEMATICS AND COMPUTING↗

A Device-Independent Screening Technique for Rapidly Identifying Next Generation OPV Materials

In this paper, we introduce a methodology that enables rapid down selection of promising new OPV polymers, based on a device-independent screening metric that takes into account intrinsic charge generation and transport, as well as charge carrier lifetimes. As a demonstration of our method, we present a case study using a set of well-known high performance polymers based on the benzodithiophene (BDT) moiety: PTB7, PTB7-Th, PBDTTT-CT, and PBDTTPD. Compared to current device-optimization based methods, we are able to identify the champion material in less time, taking only hours rather than months and may even be able to identify promising candidate materials that have been abandoned for device optimization.

14 SOLAR ENERGY↗

Efficient Probabilistic Visualization of Local Divergence of 2D Vector Fields with Independent Gaussian Uncertainty

This work focuses on visualizing uncertainty of local divergence of two-dimensional vector fields. Divergence is one of the fundamental attributes of fluid flows, as it can help domain scientists analyze potential positions of sources (positive divergence) and sinks (negative divergence) in the flow. However, uncertainty inherent in vector field data can lead to erroneous divergence computations, adversely impacting downstream analysis. While Monte Carlo (MC) sampling is a classical approach for estimating divergence uncertainty, it suffers from slow convergence and poor scalability with increasing data size and sample counts. Thus, we present a two-fold contribution that tackles the challenges of slow convergence and limited scalability of the MC approach. (1) We derive a closed-form approach for highly efficient and accurate uncertainty visualization of local divergence, assuming independently Gaussian-distributed vector uncertainties. (2) We further integrate our approach into Viskores, a platform-portable parallel library, to accelerate uncertainty visualization. In our results, we demonstrate significantly enhanced efficiency and accuracy of our serial analytical (speed-up up to 1946×) and parallel Viskores (speed-up up to 19698×) algorithms over the classical serial MC approach. We also demonstrate qualitative improvements of our probabilistic divergence visualizations over traditional mean-field visualization, which disregards uncertainty. We validate the accuracy and efficiency of our methods on wind forecast and ocean simulation datasets.

Ouermi, Timbwaoga [University of Utah]↗

Spread of an introduced parasite across the Hawaiian archipelago independent of its introduced host

1. Co-introductions of non-native parasites with non-native hosts can be a major driver of disease emergence in native species, but the conditions that promote the establishment and spread of nonnative parasites remain poorly understood. Here, we characterise the infection of a native host species by a non-native parasite relative to the distribution and density of the original non-native host species and a suite of organismal and environmental factors that have been associated with parasitism, but not commonly considered within a single system. 2. We examined the native Hawaiian goby Awaous stamineus across 23 catchments on five islands for infection by the non-native nematode parasite Camallanus cotti . We used model selection to test whether parasite infection was associated with the genetic diversity, size and population density of native hosts, the distribution and density of non-native hosts, land use and water quality. 3. We found that the distribution of non-native C. cotti parasites has become decoupled from the non-native hosts that were primary vectors of introduction to the Hawaiian Islands. Although no single intrinsic or extrinsic factor was identified that best explains parasitism of A. stamineus by C. cotti , native host size, population density and water quality were consistently identified as influencing parasite intensity and prevalence. 4. The introduction of non-native species can indirectly influence native species through infection of co-introduced parasites. Here, we show that the effects of enemy addition can extend beyond the range of non-native hosts through the independent spread of non-native parasites. This suggests that control of non-native hosts is not sufficient to halt the spread of introduced parasites. Furthermore, designing importation regulations to prevent host parasite co-introductions can promote native species conservation, even in remote areas that may not seem susceptible to human influence.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of Mass-Independent Perturbations of Cadmium in Nuclear Debris Samples

The isotopic composition of cadmium in nuclear debris was measured by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). Mass-independent perturbations due to fission product decay on the isotopes of Cd were observed. Relative fission yields for masses 111, 112, 114 and 116 were determined in each sample of nuclear debris and compared with reported values found in irradiated plutonium and uranium fuels. Mass spectrometry measurements of the valley fission product endpoints are extremely challenging due to the low cumulative fission yields and small amounts of each isotope that are produced. To overcome these challenges, a new purification method for Cd was developed and validated by examination of a number of geological reference materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: Results from independently conducted FROC/ROC studies in mammography

Purpose: From independently conducted free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) experiments, to study fixed-reader associations between three estimators: the area under the alternative FROC (AFROC) curve computed from FROC data, the area under the ROC curve computed from FROC highest rating data, and the area under the ROC curve computed from confidence-of-disease ratings. Methods: Two hundred mammograms, 100 of which were abnormal, were processed by two image-processing algorithms and interpreted by four radiologists under the FROC paradigm. From the FROC data, inferred-ROC data were derived, using the highest rating assumption. Eighteen months afterwards, the images were interpreted by the same radiologists under the conventional ROC paradigm; conventional-ROC data (in contrast to inferred-ROC data) were obtained. FROC and ROC (inferred, conventional) data were analyzed using the nonparametric area-under-the-curve (AUC), (AFROC and ROC curve, respectively). Pearson correlation was used to quantify the degree of association between the modality-specific AUC indices and standard errors were computed using the bootstrap-after-bootstrap method. The magnitude of the correlations was assessed by comparison with computed Obuchowski-Rockette fixed reader correlations. Results: Average Pearson correlations (with 95% confidence intervals in square brackets) were: Corr(FROC, inferred ROC) = 0.76[0.64, 0.84] > Corr(inferred ROC, conventional ROC) = 0.40[0.18, 0.58] > Corr (FROC, conventional ROC) = 0.32[0.16, 0.46]. Conclusions: Correlation between FROC and inferred-ROC data AUC estimates was high. Correlation between inferred- and conventional-ROC AUC was similar to the correlation between two modalities for a single reader using one estimation method, suggesting that the highest rating assumption might be questionable.

60 APPLIED LIFE SCIENCES↗

A method for online verification of adapted fields using an independent dose monitor

Purpose: Clinical implementation of online adaptive radiotherapy requires generation of modified fields and a method of dosimetric verification in a short time. We present a method of treatment field modification to account for patient setup error, and an online method of verification using an independent monitoring system.Methods: The fields are modified by translating each multileaf collimator (MLC) defined aperture in the direction of the patient setup error, and magnifying to account for distance variation to the marked isocentre. A modified version of a previously reported online beam monitoring system, the integral quality monitoring (IQM) system, was investigated for validation of adapted fields. The system consists of a large area ion-chamber with a spatial gradient in electrode separation to provide a spatially sensitive signal for each beam segment, mounted below the MLC, and a calculation algorithm to predict the signal. IMRT plans of ten prostate patients have been modified in response to six randomly chosen setup errors in three orthogonal directions.Results: A total of approximately 49 beams for the modified fields were verified by the IQM system, of which 97% of measured IQM signal agree with the predicted value to within 2%.Conclusions: The modified IQM system was found to be suitable for online verification of adapted treatment fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation and commissioning of an integrated micro-CT/RT system with computerized independent jaw collimation

Purpose: To design, construct, and commission a set of computer-controlled motorized jaws for a micro-CT/RT system to perform conformal image-guided small animal radiotherapy.Methods: The authors designed and evaluated a system of custom-built motorized orthogonal jaws, which allows the delivery of off-axis rectangular fields on a GE eXplore CT 120 preclinical imaging system. The jaws in the x direction are independently driven, while the y-direction jaws are symmetric. All motors have backup encoders, verifying jaw positions. Mechanical performance of the jaws was characterized. Square beam profiles ranging from 2 × 2 to 60 × 60 mm{sup 2} were measured using EBT2 film in the center of a 70 × 70 × 22 mm{sup 3} solid water block. Similarly, absolute depth dose was measured in a solid water and EBT2 film stack 50 × 50 × 50 mm{sup 3}. A calibrated Farmer ion chamber in a 70 × 70 × 20 mm{sup 3} solid water block was used to measure the output of three field sizes: 50 × 50, 40 × 40, and 30 × 30 mm{sup 2}. Elliptical target plans were delivered to films to assess overall system performance. Respiratory-gated treatment was implemented on the system and initially proved using a simple sinusoidal motion phantom. All films were scanned on a flatbed scanner (Epson 1000XL) and converted to dose using a fitted calibration curve. A Monte Carlo beam model of the micro-CT with the jaws has been created using BEAMnrc for comparison with the measurements. An example image-guided partial lung irradiation in a rat is demonstrated.Results: The averaged random error of positioning each jaw is less than 0.1 mm. Relative output factors measured with the ion chamber agree with Monte Carlo simulations within 2%. Beam profiles and absolute depth dose curves measured from the films agree with simulations within measurement uncertainty. Respiratory-gated treatments applied to a phantom moving with a peak-to-peak amplitude of 5 mm showed improved beam penumbra (80%–20%) from 3.9 to 0.8 mm.Conclusions: A set of computer-controlled motorized jaws for a micro-CT/RT system were constructed with position reliably better than a tenth of a millimeter. The hardware system is ready for image-guided conformal radiotherapy for small animals with capability of respiratory-gated delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fraction frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗