Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Influence of exciting frequency on gas and ion rotational temperatures of nitrogen capacitively coupled plasma

By using optical emission spectroscopy, the nitrogen gas and ion rotational temperatures in capacitively coupled plasma discharges with different exciting frequencies are investigated. The rotational temperatures are acquired by comparing the measured and calculated spectra of selected transitions with a least-square procedure. It is found that N{sub 2} gas rotational temperature minimum around 13 MHz is the combined effect of ion-dominated heating and electron-dominated heating in the plasma. The influence of exciting frequency on N{sub 2}{sup +} rotational temperature is much more than that of the N{sub 2} molecule, the lower frequency, the higher N{sub 2}{sup +} rotational temperature. Also, N{sub 2}{sup +} rotational temperature is much higher than the corresponding N{sub 2} gas rotational temperature in the plasma driven by low frequencies. These experimental phenomena may be attributed to the effective ion heating and/or possible resonant heating in the bulk plasma under the low-frequency field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced High Harmonic Generation from Multiply Ionized Argon above 500 eV through Laser Pulse Self-Compression

By combining laser pulse self-compression and high harmonic generation within a single waveguide, we demonstrate high harmonic emission from multiply charged ions for the first time. This approach enhances the laser intensity and counteracts ionization-induced defocusing, extending the cutoff photon energy in argon above 500 eV for the first time, with higher spectral intensity and cutoff energy than He for the same input laser parameters. This Letter demonstrates a pathway for extending high harmonic emission to very high photon energies using large, multiply charged, ions with high ionization potentials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoluminescence properties of Tb-Eu-Mn-codoped fluoroborate glasses under γ-irradiation

We report here an energy transfer from Tb{sup 3+} to Eu{sup 3+}, Mn{sup 2+} and Eu{sup 2+} to Tb{sup 3+} and Mn{sup 2+} for an un-irradiated and γ-irradiated B{sub 2}O{sub 3}-Al{sub 2}O{sub 3}-Na{sub 2}O-SrF{sub 2} glass samples, respectively. The blue emission from Eu{sup 2+} ions as well as green and red emission from Tb{sup 3+}, Eu{sup 3+}, and Mn{sup 2+} ions will contribute to the generation of white light while excited at 339 nm using a xenon lamp. Furthermore, the chromaticity color coordinates, correlated color temperature, and quantum efficiency parameters are calculated for all the glass samples, and their relative variations with respect to γ-irradiation dose are presented.

36 MATERIALS SCIENCE↗

Plasma emission spectroscopy for operating and developing the Spallation Neutron Source (SNS) H{sup −} ion sources

A RF-driven, Cs-enhanced H{sup −} ion source feeds the SNS accelerator with a high current (typically >50 mA), ∼1.0 ms pulsed beam at 60 Hz. To achieve the persistent high current beam for several weeks long service cycles, each newly installed ion source undergoes a rigorous conditioning and cesiation processes. Plasma conditioning outgases the system and sputter-cleans the ion conversion surfaces. A cesiation process immediately following the plasma conditioning releases Cs to provide coverage on the ion conversion surfaces. The effectiveness of the ion source conditioning and cesiation is monitored with plasma emission spectroscopy using a high-sensitivity optical spectrometer. Plasma emission spectroscopy is also used to provide a means for diagnosing and confirming a failure of the insulating coating of the ion source RF antenna which is immersed in the plasma. Emissions of composition elements of the antenna coating material, Na emission being the most significant, drastically elevate to signal a failure when it happens. Plasma spectra of the developmental ion source with an AlN (aluminum nitrite) chamber and an external RF antenna are also briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rare-earth plasma extreme ultraviolet sources at 6.5-6.7 nm

We have demonstrated a laser-produced plasma extreme ultraviolet source operating in the 6.5-6.7 nm region based on rare-earth targets of Gd and Tb coupled with a Mo/B{sub 4}C multilayer mirror. Multiply charged ions produce strong resonance emission lines, which combine to yield an intense unresolved transition array. The spectra of these resonant lines around 6.7 nm (in-band: 6.7 nm {+-}1%) suggest that the in-band emission increases with increased plasma volume by suppressing the plasma hydrodynamic expansion loss at an electron temperature of about 50 eV, resulting in maximized emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma emission spectroscopy for operating and developing the Spallation Neutron Source (SNS) H- ion sources

An RF-driven, Cs-enhanced H- ion source feeds the SNS accelerator with a high current (typically >50 mA), ~1.0 ms pulsed beam at 60 Hz. To achieve the persistent high current beam for several weeks long service cycles, each newly installed ion source undergoes a rigorous conditioning and cesiation processes. Plasma conditioning outgases the system and sputter-cleans the ion conversion surfaces. A cesiation process immediately following the plasma conditioning releases Cs to provide coverage on the ion conversion surfaces. The effectiveness of the ion source conditioning and cesiation is monitored with plasma emission spectroscopy using a high-sensitivity optical spectrometer. Plasma emission spectroscopy is also used to provide a mean for diagnosing and confirming a failure of the insulating coating of the ion source RF antenna which is immersed in the plasma. Emissions of composition elements of the antenna coating material, Na emission being the most significant, drastically elevate to signal a failure when it happens. Plasma spectra of the developmental ion source with an AlN chamber and an external RF antenna are also briefly discussed.

Han, Baoxi↗

On the origin of 4640-4650 A emission in X-ray stars

The origin is investigated for a prominent and rapidly variable emission feature near the 4640-A line which has been observed in the optical counterparts of Sco X-1, Cyg X-2, Her X-1, Cen X-3, 3U 0900-40, and 3U 1700-37. It is suggested that the emission is generated in the vicinity of a compact X-ray source by the interaction of X-rays with nearby gaseous matter and that three likely sources of the emission are the ions C III, N III, and O II. Results are presented for a detailed mathematical model of an X-ray source surrounded by a uniform distribution of matter and are used to evaluate possible emission mechanisms. It is concluded that selective emission of N III (4634 to 4641 A) in the Bowen fluorescence process may be the responsible mechanism.

Mcclintock, J. E.↗

Final Report of B548129: Spectral Analysis of Soft X-Ray Data from NSTX

We present a summary of work performed under subcontract B548129 'Spectral Analysis of Soft X-Ray Data from NSTX'. This summary is comprised of papers and poster presentations prepared under this subcontract. The X-ray and Extreme Ultraviolet Spectrometer (XEUS) has been used to monitor the line emission from various impurity ions on NSTX, in particular the K-shell emission of helium-like and hydrogen-like B, C, N, and O. While C VI typically dominates the spectrum, unusually strong emission from N VII has been observed in multiple discharges during the past run campaign. In this case, the nitrogen concentration can exceed that of carbon by an order of magnitude. Time-dependent measurements show that the nitrogen concentration builds up over the course of the discharge and coincides with a build up of boron. In a few cases we observed several unknown lines. These are clearly lines from heavy impurities, possibly molybdenum. Some of these lines can be explained by the emission from Ti XIII.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Apparent electrostatic ion cyclotron waves in the diffuse aurora

Emissions that have properties consistent with electrostatic ion cyclotron (EIC) waves have been observed at low altitude in the diffuse aurora by a sounding rocket payload. Peaks were observed in the power spectrum of the electric field near the hydrogen and oxygen ion cyclotron frequencies. Doppler shift and polarization analyses have been performed using EIC wave parameters derived from linear theory. Both analyses indicated that these emissions had properties consistent with those expected for H(+) and O(+) EIC waves. The two analyses indicated that both emission bands were due to waves propagating eastward parallel to the poleward boundary of the diffuse aurora. The large local cold plasma density and resulting Landau damping require that the source be local. Magnetometer data indicated the presence of a downward parallel current density of 5 microamps/sq m. Sufficient free energy for the waves was available from this current, although the waves were observed frequently at altitudes where the ion-neutral collision frequency exceeded the oxygen cyclotron frequency.

Bering, E. A.↗

HST-COS OBSERVATIONS OF AGNs. III. SPECTRAL CONSTRAINTS IN THE LYMAN CONTINUUM FROM COMPOSITE COS/G140L DATA

The rest-frame ultraviolet (UV) spectra of active galactic nuclei (AGNs) are important diagnostics of both accretion disk physics and their contribution to the metagalactic ionizing UV background. Though the mean AGN spectrum is well characterized with composite spectra at wavelengths greater than 912 Å, the shorter-wavelength extreme-UV (EUV) remains poorly studied. In this third paper in a series on the spectra of AGNs, we combine 11 new spectra taken with the Cosmic Origins Spectrograph on the Hubble Space Telescope with archival spectra to characterize the typical EUV spectral slope of AGNs from λ{sub rest} ∼ 850 Å down to λ{sub rest} ∼ 425 Å. Parameterizing this slope as a power law, we obtain F{sub ν} ∝ ν{sup −0.72±0.26}, but we also discuss the limitations and systematic uncertainties of this model. We identify broad emission features in this spectral region, including emission due to ions of O, Ne, Mg, and other species, and we limit the intrinsic He i 504 Å photoelectric absorption edge opacity to τ{sub He} {sub i} < 0.047.

79 ASTRONOMY AND ASTROPHYSICS↗

Line integration effects on ion temperatures in tokamak plasmas measured with neutron emission spectroscopy

The line integrated line emission measured by neutron spectrometers at JET along sight lines in the vertical and horizontal planes has been simulated in Monte Carlo calculations to determine the relationship between the measured (effective) ion temperature (T{sub eff}) relative to the peak value of the profile (T{sub 0}). The general sight line dependence of (T{sub eff}) was expressed analytically for circular plasmas which was used to explain the simulated results for the actual JET sight lines. The analytical model with parametrization of sight lines and plasma profiles is described and the results are used to discuss dual sight line measurements that can be tested at JET and its forward implications for study burning (nearly thermal) plasmas of ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observations of E and F region Mg(+) from Spacelab 1

Images of airglow at 2800 A were taken on the Spacelab 1 Shuttle mission and have been interpreted to be solar resonant emission of magnesium ions. On two orbital passes, observations were made near the magnetic equator while observing in the 2800-A channel. The observations were made near the sunset terminator (approximately 1800 LT), in winter (1983, day 335). Three separate emission clouds were observed, all of which extended well into the F region. The location of the clouds in horizontal space is shown. The processed images have been pseudocolored to highlight the intensity distribution in the clouds. Observations included clouds with apparent magnetic-field aligned striations. Bright emissions were observed at the magnetic equator, at 12-deg north magnetic latitude, and at 12-deg south magnentic latitude. Cloud-center brightnesses varied between 680 rayleighs and 1700 rayleighs.

Mende, S. B.↗

The High-Excitation Planetary Nebula NCG 246: Optical and Near-Ultraviolet Observations and Two-dimensional Numerical Models

We have imaged the planetary nebula (PN) NGC 246 in the near-ultraviolet wavelengths [Ne v] 342.6 nm, the Bowen fluorescence line of 0 111 at 344.4 nm, and a nearby line-free region centered on 338.6 nm, as well as H(alpha), [O III] 500.7 nm, and [S II] 673.0 and 671.5 nm. Imaging in the 344.4 nm line is necessary to deconvolve contamination of the [Ne v] images by O III 342.9 nm. The emission from the shell and inner parts of the nebula is detected in [Ne v]. The radial profiles of the [Ne v] brightness decrease with radius from the exciting star, indicating that the bulk of the emission from this ion is due to the hard UV stellar radiation field, with a (probably) marginal contribution from collisional ionization in a shock between the PN shell and the interstellar medium (ISM). In contrast, the radial profiles of the emission in H(alpha), [0 III] 500.7 nm, and [S II] are flatter and peak at the location of the shell. The emission of [S II] probably traces the interaction of the PN with the ambient ISM. We also present two-dimensional numerical simulations for this PN-ISM interaction. The simulations consider the stellar motion with respect to the ambient ISM, with a velocity of 85 km/s , and include the time evolution of the wind parameters and UV radiation field from the progenitor star.

Szentgyorgyi, Andrew↗

Role of Transition Metals in Metal–Organic Frameworks as Nanoporous Ion Emitters for Thermal Ionization Mass Spectrometry

Thermal ionization mass spectroscopy (TIMS) is a powerful analytical technique that allows for precise determination of isotopic ratios. Analysis on low abundance samples, however, can be limited by the ionization efficiency. Following an investigation into a new type of metal-organic hybrid material devised to promote the emission of analyte ions (nano-PIES) and reduce traditional sample loading problems, this work probes the impact that changing the metal in the material has on the ionization of Uranium-238. Being derived from metal-organic frameworks (MOFs), nano-PIEs inherit the tunability of the parent MOFs; the MOF-74 series has been well studied for probing the impact various framework metals (i.e., Mg, Mn, Co, Ni, Cu, Zn, and Cd) have on material properties, and thus, a series of nano-PIEs with different metals were derived from an isoreticular MOF-74 series. In conclusion, trends in ionization efficiency were studied as a function of ionization potential, volatility, and work function of the framework metals as well as the mechanism of ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EARLY CHROMOSPHERIC RESPONSE DURING A SOLAR MICROFLARE OBSERVED WITH SOHO's CDS AND RHESSI

We observed a solar microflare with RHESSI and SOHO's Coronal Diagnostic Spectrometer (CDS) on 2009 July 5. With CDS we obtained rapid cadence (7 s) stare spectra within a narrow field of view toward the center of AR 11024. The spectra contain emission lines from ions that cover a wide range of temperature, including He I (<0.025 MK), O V (0.25 MK), Si XII (2 MK), and Fe XIX (8 MK). The start of a precursor burst of He I and O V line emission preceded the steady increase of Fe XIX line emission by about 1 minute and the emergence of 3-12 keV X-ray emission by about 4 minutes. Thus, the onset of the microflare was observed in upper chromospheric (He I) and transition region (O V) line emission before it was detected in high-temperature flare plasma emission. Redshifted O V emission during the precursor suggests explosive chromospheric evaporation, but no corresponding blueshifts were found with either Fe XIX (which was very weak) or Si XII. Similarly, in subsequent microflare brightenings the O V and He I intensities increased (between 49 s and almost 2 minutes) before emissions from the hot flare plasma. Although these time differences likely indicate heating by a nonthermal particle beam, the RHESSI spectra provide no additional evidence for such a beam. In intervals lasting up to about 3 minutes during several bursts, the He I and O V emission line profiles showed secondary, highly blueshifted ({approx}-200 km s{sup -1}) components; during intervals lasting nearly 1 minute the velocities of the primary and secondary components were oppositely directed. Combined with no corresponding blueshifts in either Fe XIX or Si XII, this indicates that explosive chromospheric evaporation occurred predominantly at either comparatively cool temperatures (<2 MK) or within a hot temperature range to which our observations were not sensitive (e.g., between 2 and 8 MK).

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Early Chromospheric Response During a Solar Microflare Observed with SOHO's CDS and RHESSI

We observed a solar microflare with RHESSI and SOHO's Coronal Diagnostic Spectrometer (CDS) on 2009 July 5. With CDS we obtained rapid cadence (7 s) stare spectra within a narrow field of view toward the center of AR 11024. The spectra contain emission lines from ions that cover a wide range of temperature, including He I (< 0.025 MK), O V (0.25 MK), Si XII (2 MK), and Fe XIX (8 MK). The start of a precursor burst of He I and O V line emission preceded the steady increase of Fe XIX line emission by about 1 minute, and the emergence of 3-12 keV X-ray emission by about 4 minutes. Thus the onset of the microflare was observed in upper chromospheric (He I) and transition region (O V) line emission before it was detected in high temperature flare plasma emission. Redshifted O V emission during the precursor suggests explosive chromospheric evaporation, but no corresponding blueshifts were found with either Fe XIX (which was very weak) or Si XII. Similarly, in subsequent microflare brightenings the O V and He I intensities increased (between 49 s and almost 2 minutes) before emissions from the hot flare plasma. Although these time differences likely indicate heating by a nonthermal particle beam, the RHESSI spectra provide no additional evidence for such a beam. In intervals lasting up to about 3 minutes during several bursts, the He I and O V emission line profiles showed secondary, highly blueshifted ( approximately 200 km/s) components; during intervals lasting nearly 1 minute the velocities of the primary and secondary components were oppositely directed. Combined with no corresponding blueshifts in either Fe XIX or Si XII, this indicates that explosive chromospheric evaporation occurred predominantly at either comparatively cool temperatures (< 2 MK) or within a hot temperature range to which our observations were not sensitive (e.g., between 2 and 8 MK).

Brosius, Jeffrey W.↗

Surface plasma source with anode layer plasma accelerator

Proposed plasma generation system can be used for high current negative ion beam production and for directed deposition by flux of sputtered neutrals and negative ions. The main mechanism of negative ion formation in surface plasma sources is the secondary emission from low work function surface bombarded by a flux of positive ion or neutrals. The emission of negative ions is enhanced significantly by introducing a small amount of cesium or other substance with low ionization potential. In the proposed source are used positive ions generated by Hall drift plasma accelerator (anode layer plasma accelerator or plasma accelerator with insulated channel, with cylindrical or race track configuration of emission slit). The target-emitter is bombarded by the ion beam accelerated in crossed ExB fields. Negative ions are extracted from the target surface with geometrical focusing and are accelerated by negative voltage applied between emitter and plasma, contacting with the plasma accelerator. Hall drift ion source has a special design with a space for passing of the emitted negative ions and sputtered particles through the positive ion source.

36 MATERIALS SCIENCE↗

High-resolution Laboratory Measurements of Coronal Lines near the Fe ix Line at 171 Å

In this work, we present high-resolution laboratory measurements in the spectral region between 165 and 175 Å that focus on the emission from various ions of C, O, F, Ne, S, Ar, Fe, and Ni. This wavelength region is centered on the λ171 Fe ix channel of the Atmospheric Imaging Assembly on the Solar Dynamics Observatory, and we place special emphasis on the weaker emission lines of Fe ix predicted in this region. In general, our measurements show a multitude of weak lines missing in the current databases, where the emission lines of Ni are probably most in need of further identification and reclassification. We also find that the wavelengths of some of the known lines need updating. Using the multi-reference Møller–Plesset method for wavelength predictions and collisional-radiative modeling of the line intensities, we have made tentative assignments of more than a dozen lines to the spectrum of Fe ix, some of which have formerly been identified as Fe vii, Fe xiv, or Fe xvi lines. Several Fe features remain unassigned, although they appear to be either Fe vii or Fe x lines. Further work will be needed to complete and correct the spectral line lists in this wavelength region.

74 ATOMIC AND MOLECULAR PHYSICS↗