Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Characterization and Quantification of Intact 26S Proteasome Proteins by Real-Time Measurement of Intrinsic Fluorescence Prior to Top-down Mass Spectrometry

Quantification of gas-phase intact protein ions by mass spectrometry (MS) is impeded by highly-variable ionization, ion transmission, and ion detection efficiencies. Therefore, quantification of proteins using MS-associated techniques is almost exclusively done after proteolysis where peptides serve as proxies for estimating protein abundance. Advances in instrumentation, protein separations, and informatics have made large-scale sequencing of intact proteins using top-down proteomics accessible to the proteomics community; yet quantification of proteins using a top-down workflow has largely been unaddressed. Here we describe a label-free approach to determine the abundance of intact proteins separated by nanoflow liquid chromatography prior to MS analysis by using solution-phase measurements of ultraviolet light-induced intrinsic fluorescence (UV-IF). UV-IF is measured directly at the electrospray interface just prior to the capillary exit where proteins containing at least one tryptophan residue are readily detected. UV-IF quantification was demonstrated using commercially available protein standards and provided more accurate and precise protein quantification than MS ion current. We evaluated the parallel use of UV-IF and top-down tandem MS for quantification and identification of protein subunits and associated proteins from an affinity-purified 26 S proteasome sample from Arabidopsis thaliana. We identified 26 unique proteins and quantified 13 tryptophan-containing species. Our analyses discovered previously unidentified N-terminal processing of the β6 (PBF1) and β7 (PBG1) subunit - such processing of PBG1 may generate a heretofore unknown additional protease active site upon cleavage. In addition, our approach permitted the unambiguous identification and quantification both isoforms of the proteasome-associated protein DSS1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cold cathode ionization gage has rigid metal housing

Cold cathode ionization gage in a stainless steel housing accurately measures high pressures. The penning effect is used with a high voltage discharge in the presence of a magnetic field for an ion current proportional to the gas pressure in the gage.

Herzog, R.↗

Surface ionization hysteresis phenomena

Temperature field influence on hysteresis in Cs surface ionization on metal surfaces, observing adsorption phase fine structure and ion current density increase

Wilson, R. G.↗

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

The Bennett ion-mass spectrometer on Atmosphere Explorer-C and -E.

The Bennett spectrometer to be flown on Atmosphere Explorer-C and -E (AE-C and AE-E) is designed to measure, throughout the 120 to 4000-km orbit, the concentrations of all thermal positive ions in the mass range 1 to 72 amu and number density range 5 to 5,000,000 ions per cu cm. To reduce the buildup of ram pressure and facilitate measurements at low altitude, the analyzer is vented, and a multigrid ion-current collector is employed. An extensive command capability permits optimization of instrument parameters for particular measurement objectives; commandable functions include mass-scan range and period, the sensitivity-resolution characteristic of the analyzer, orifice potential, and in-flight calibration.

Brinton, H. C.↗

High-temperature mass spectrometry - Vaporization of group 4-B metal carbides

The high temperature vaporization of the metal-carbon systems TiC, ZrC, HfC, and ThC was studied by the Knudsen effusion - mass spectrometric method. For each system the metal dicarbide and tetracarbide molecular species were identified in the gas phase. Relative ion currents of the carbides and metals were measured as a function of temperature. Second- and third-law methods were used to determine enthalpies. Maximum values were established for the dissociation energies of the metal monocarbide molecules TiC, ZrC, HfC, and ThC. Thermodynamic functions used in the calculations are discussed in terms of assumed molecular structures and electronic contributions to the partition functions. The trends shown by the dissociation energies of the carbides of Group 4B are compared with those of neighboring groups and discussed in relation to the corresponding oxides and chemical bonding. The high temperature molecular beam inlet system and double focusing mass spectrometer are described.

Stearns, C. A.↗

Laboratory simulation of the structure of disturbed zones around bodies in space

Description of laboratory studies of certain aspects of the spacecraft/space plasma interaction regarding, in particular, the near and intermediate wake regions. The plasma wind tunnel facilities and the diagnostic techniques employed in these tests are described. Results are obtained which concern the variation of the normalized ion flux with normalized distance along the wake axis downstream from a conducting spherical body, the variation of the normalized width of the disturbed region with normalized distance downstream from the body center, and the location of the point of maximum ion current enhancement as a function of body potential.

Stone, N. H.↗

Parametric study of near-wake structure of spherical and cylindrical bodies in the laboratory

Some aspects of the interaction between metal bodies and streaming rarefied plasmas were studied in a newly constructed plasma wind tunnel as part of an attempt to investigate (via simulation) phenomena relevant to the spacecraft/space plasma interaction. Detailed near-wake ion current profiles for both spherical and cylindrical bodies at different body potentials and at different plasma flow parameters are presented. Various features of the profiles can be correlated, at least qualitatively, with both plasma and body characteristics. The general importance of body geometry is qualitatively demonstrated. In addition, a discussion of the relevance of the above studies to previous in situ data obtained from the Ariel I and Gemini/Agena missions is given.

Oran, W. A.↗

OGO-5 observations of the magnetopause

OGO-5 observations show not only that the average position of the magnetopause boundary moves in response to changes in dynamic pressure, but also that it moves in response to changes in the north-south component of the interplanetary field. Further, the boundary often oscillates about its average position as waves propagate along the boundary away from the nose region. The variation of the magnetic field through the boundary at times can be a simple rotation with no change in magnitude, and at other times can resemble a simple tangential discontinuity. However, it often displays complex patterns such as field enhancements on the magnetospheric side of the boundary or apparently uncorrelated field strength and direction changes. One particularly simple boundary crossing has been studied in detail with both positive ion data and magnetic field data. In this case, the electron and ion currents could be separately deduced and the structure agreed with that expected for a Chapman-Ferraro boundary with almost complete neutralization.

Russell, C. T.↗

Geometry and properties of the plasma in a quadrupole ion pump

The diameter of the plasma in a quadrupole ionization gauge and quadrupole ion pump has been measured as a function of pressure. The radio-frequency quadrupole systems are tuned in such a way that electrons remain on stable trajectories in the center of the tube. Being emitted at one end, the electrons encounter an inverted field at the other end so that they travel on spiral paths back and forth until they collide with the rest gas molecules, producing ions which are collected as an ion current at a cylinder surrounding the four hyperbolically shaped quadrupole electrodes.

Schwarz, H.↗