Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Streaming in a Nuclear Grade Sandwich Composite for Microreactor Shielding

The NGSC is a new approach to develop a shield structure for microreactors which combines the biological shielding with the reactor pressure vessel. Six layers of SS316 skins and core materials are present in the NGSC, where the core materials are reduce the neutron and gamma dose. Previous work has examined how a simplified NGSC can be optimized for cost, dose, and weight. This work explored the inclusion of SS36 ribs, which helps maintain the structural integrity of the NGSC, affects the transportation of radiation through the NGSC. For B$_4$C layers, the addition of ribs reduces neutron absorption but increase photon absorption. For WB$_4$-cermet layers, the addition of ribs reduces neutron absorption and reduces photon absorption.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The IRAS radiation environment

Orbital flux integration for three selected mission altitudes and geographic instantaneous flux-mapping for nominal flight-path altitude were used to determine the external charged particle radiation predicted for the Infrared Astronomy Satellite. A current field model was used for magnetic field definitions for three nominal circular trajectories and for the geographic mapping positions. Innovative analysis features introduced include (1) positional fluxes as a function of time and energy for the most severe pass through the South Atlantic Anomaly; (2) total positional doses as a function of time and shield thickness; (3) comparison mapping fluxes for ratios of positional intensities to orbit integrated averages; and (4) statistical exposure-time history of a trajectory as a function of energy indicating, in percent of total mission duration, the time intervals over which the instantaneous fluxes would exceed the orbit integrated averages. Results are presented in tables and graphs.

Stassinopoulos, E. G.↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Outcomes of Diffusion Tensor Tractography-Integrated Stereotactic Radiosurgery

Purpose: To analyze the effect of use of tractography of the critical brain white matter fibers created from diffusion tensor magnetic resonance imaging on reduction of morbidity associated with radiosurgery. Methods and Materials: Tractography of the pyramidal tract has been integrated since February 2004 if lesions are adjacent to it, the optic radiation since May 2006, and the arcuate fasciculus since October 2007. By visually confirming the precise location of these fibers, the dose to these fiber tracts was optimized. One hundred forty-four consecutive patients with cerebral arteriovenous malformations who underwent radiosurgery with this technique between February 2004 and December 2009 were analyzed. Results: Tractography was prospectively integrated in 71 of 155 treatments for 144 patients. The pyramidal tract was visualized in 45, the optic radiation in 22, and the arcuate fasciculus in 13 (two tracts in 9). During the follow-up period of 3 to 72 months (median, 23 months) after the procedure, 1 patient showed permanent worsening of pre-existing dysesthesia, and another patient exhibited mild transient hemiparesis 12 months later but fully recovered after oral administration of corticosteroid agents. Two patients had transient speech disturbance before starting integration of the arcuate fasciculus tractography, but no patient thereafter. Conclusion: Integrating tractography helped prevent morbidity of radiosurgery in patients with brain arteriovenous malformations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered on PMOS transistors of different widths, W{sub NARROW} = 0.24 μm and W{sub WIDE} = 10 μm. The devices are irradiated using 10 keV X-rays at several total dose steps up to 3 MGy. On the one hand, negative threshold voltage shifts of more than 3.3 V are extracted after 3 MGy on narrow transistors. Even very high, this voltage shift is consistent with RINCE in narrow open layout transistors. On the other hand, voltage shifts greater than 2.5 V are extracted on wide transistors. Obviously, this result should not be associated neither to positive charge trapping in the thin gate oxide nor to any RINCE in this very wide transistor geometry. NMOS and PMOS transistors exhibit a clear asymmetrical behaviour. But contrary to what is commonly observed at 'low' TID range, the PMOS transistor is here more impacted than the NMOS one. The final paper will thus provide an extensive study of these phenomena using other device designs and geometries tested with dedicated TID experiments to discuss whether or not this effect revealed at very high TID, i.e. several MGy, may be attributed to an enhanced high-TID induced charge trapping mechanism in thin gate oxides. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medical Data Architecture Project Capabilities and Design

Mission constraints will challenge the delivery of medical care on a long-term, deep space exploration mission. This type of mission will be restricted in the availability of medical knowledge, skills, procedures and resources to prevent, diagnose, and treat in-flight medical events. Challenges to providing medical care are anticipated, including resource and resupply constraints, delayed communications and no ability for medical evacuation. The Medical Data Architecture (MDA) project will enable medical care capability in this constrained environment. The first version of the system, called "Test Bed 1," includes capabilities for automated data collection, data storage and data retrieval to provide information to the Crew Medical Officer (CMO). Test Bed 1 seeks to establish a data architecture foundation and develop a scalable data management system through modular design and standardized interfaces. In addition, it will demonstrate to stakeholders the potential for an improved, automated, flow of data to and from the medical system over the current methods employed on the International Space Station (ISS). It integrates a set of external devices, software and processes, and a Subjective, Objective, Assessment, and Plan (SOAP) note commonly used by clinicians. Medical data like electrocardiogram plots, heart rate, skin temperature, respiration rate, medications taken, and more are collected from devices and stored in the Electronic Medical Records (EMR) system, and reported to crew and clinician. Devices integrated include the Astroskin biosensor vest and IMED CARDIAX electrocardiogram (ECG) device with INEED MD ECG Glove, and the NASA-developed Medical Dose Tracker application. The system is designed to be operated as a standalone system, and can be deployed in a variety of environments, from a laptop to a data center. The system is primarily composed of open-source software tools, and is designed to be modular, so new capabilities can be added. The software components and integration methods will be discussed.

Data architecture↗

Reactor cell neutron dose for the molten salt breeder reactor conceptual design

The private sector’s interest in the active development of molten salt reactors has led to the need to develop and test advanced modeling and simulation tools to analyze various advanced reactor types under numerous conditions. This paper discusses the effort undertaken to model the Oak Ridge National Laboratory (ORNL) Molten Salt Breeder Reactor (MSBR) design using ORNL’s Shift Monte Carlo code. The MSBR model integrates a Monte Carlo N-Particle (MCNP) MSBR core model with an MCNP model that was generated from a CAD model of the external components and the reactor building, which was subsequently run in Shift. This paper focuses on development of the fully integrated model and its use in performing neutron transport calculations in the reactor cell area. This model is intended to aid in understanding radiological dose conditions during operation, as well as the iron dpa rates in the reactor vessel. The neutron biological dose rates and flux calculated in the reactor cell are much higher in the MSBR than in typical light-water reactors. The implications of these results and future work are also discussed in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Regulatory Considerations for Domestic Reprocessing Facility Physical Security

U.S. advanced non-light-water reactor vendors may pursue collocated on-site reprocessing activities. Therefore, these facilities are likely to possess formula quantities, or Category I quantities, of special nuclear material (SNM) during normal operations. The U.S. Nuclear Regulatory Commission (U.S. NRC) has yet to formally establish a regulatory framework for commercial reprocessing. While Category I requirements would explicitly not apply in this circumstance under current regulatory requirements, regulatory certainty does not exist. A novel framework should be developed to ensure public health and safety while also risk-informing the physical security requirements. This report reviews the relevant background of related rulemaking activities and proposes risk-informed physical protection requirements to satisfy these objectives. Insights from NRC security-related rulemaking activities provide a substantial technical basis to approach potential establishment of physical security requirements for reprocessing facilities. If a licensee can provide justification that the material satisfies a sufficient self-protecting radiation dose threshold, the material may not be subject to theft or diversion requirements and only potential sabotage requirements would apply. Furthermore, if the material can be justified to be moderately dilute, a set of risk-informed requirements could provide adequate protection of public health and safety. A revised performance objective for prevention of theft of moderately dilute Category I SNM may be detection to allow prompt recovery by a local law enforcement agency. However, a significant caveat to the proposed categorization scheme is the unknown integration of radiological sabotage with requirements for the protection against theft. Future licensees should consult with the NRC regarding treatment of this regulatory topic. Additionally, the self-protecting radiation dose threshold (either the existing or a proposed future threshold) would need to be considered. An integrated approach may apply graded potential requirements for protection against the design basis threat of radiological sabotage currently applicable to commercial nuclear power plants and Category I SNM facilities defined within 10 CFR 73.1(a).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The development of remote wireless radiation dose monitoring system

Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-CD-209-08: Quantification of the Interplay Effect in Proton Pencil Beam Scanning Treatment of Lung

Purpose: To quantify the dose degradation caused by the interplay effect based on a beam specific motion analysis in proton pencil beam scanning (PBS) treatment of lung tumors Methods: PBS plans were optimized on average CT using a beam-specific PTV method for 10 consecutive patients with locally advanced non-small-cell-lung-cancer (NSCLC) treated with proton therapy to 6660/180 cGy. End inhalation (CT0) and end exhalation (CT50) were selected as the two extreme scenarios to acquire the relative stopping power ratio difference (Δrsp) for a respiration cycle. The water equivalent difference (ΔWET) per radiological path was calculated from the surface of patient to the iCTV by integrating the Δrsp of each voxel. The motion magnitude of each voxel within the target follows a quasi-Gaussian distribution. A motion index (MI (>5mm WET)), defined as the percentage of target voxels with an absolute integral ΔWET larger than 5 mm, was adopted as a metric to characterize interplay. To simulate the treatment process, 4D dose was calculated by accumulating the spot dose on the corresponding respiration phase to the reference phase CT50 by deformable image registration based on spot timing and patient breathing phase. Results: The study indicated that the magnitude of target underdose in a single fraction plan is proportional to the MI (p<0.001), with larger motion equating to greater dose degradation and standard deviations. The target homogeneity, minimum, maximum and mean dose in the 4D dose accumulations of 37 fractions varied as a function of MI. Conclusion: The MI quantification metric can predict the level of dose degradation in PBS lung cancer treatment, which potentially serves as a clinical decision tool to assess whether patients are suitable to receive PBS treatment.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-05: Dosimetric and Radiobiological Validation of Respiratory Gating in Conventional and Hypofractionated Radiotherapy of the Lung: Effect of Dose, Dose Rate, Gating Window and Breathing Pattern

Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240 cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.

60 APPLIED LIFE SCIENCES↗

A study of the radiation environment on board the space shuttle flight STS-57

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Badhwar, G. D.↗

Microstructural evolution of type 304 and 316 stainless steels under neutron irradiation at LWR relevant conditions

Extension of light water reactors' useful life will expose austenitic internal core components to irradiation damage levels beyond 100 displacements per atom (dpa), which will lead to profound microstructural evolution and consequent degradation of macroscopic properties. Microstructural evolution, including Frank loops, cavities, precipitates, and segregation at boundaries and the resultant radiation hardening in type 304 and 316 stainless steel (SS) variants, were studied in this work via experimental characterization and multiple simulation methods. Experimental data for up to 40 heats of type 304SS and 316SS variants irradiated in different reactors to 0.6–120 dpa at 275–375°C were either generated from this work or collected from literature reports. These experimental data were then combined with models of Frank loop and cavity evolution, computational thermodynamics and precipitation, and ab initio and rate theory integrated radiation-induced segregation models to provide insights into microstructural evolution and degradation at higher radiation doses.

36 MATERIALS SCIENCE↗

Lithium chloride protects retinal neurocytes from nutrient deprivation by promoting DNA non-homologous end-joining

Lithium chloride is a therapeutic agent for treatment of bipolar affective disorders. Increasing numbers of studies have indicated that lithium has neuroprotective effects. However, the molecular mechanisms underlying the actions of lithium have not been fully elucidated. This study aimed to investigate whether lithium chloride produces neuroprotective function by improving DNA repair pathway in retinal neurocyte. In vitro, the primary cultured retinal neurocytes (85.7% are MAP-2 positive cells) were treated with lithium chloride, then cultured with serum-free media to simulate the nutrient deprived state resulting from ischemic insult. The neurite outgrowth of the cultured cells increased significantly in a dose-dependent manner when exposed to different levels of lithium chloride. Genomic DNA electrophoresis demonstrated greater DNA integrity of retinal neurocytes when treated with lithium chloride as compared to the control. Moreover, mRNA and protein levels of Ligase IV (involved in DNA non-homologous end-joining (NHEJ) pathway) in retinal neurocytes increased with lithium chloride. The end joining activity assay was performed to determine the role of lithium on NHEJ in the presence of extract from retinal neurocytes. The rejoining levels in retinal neurocytes treated with lithium were significantly increased as compared to the control. Furthermore, XRCC4, the Ligase IV partner, and the transcriptional factor, CREB and CTCF, were up-regulated in retinal cells after treating with 1.0 mM lithium chloride. Therefore, our data suggest that lithium chloride protects the retinal neural cells from nutrient deprivation in vitro, which may be similar to the mechanism of cell death in glaucoma. The improvement in DNA repair pathway involving in Ligase IV might have an important role in lithium neuroprotection. This study provides new insights into the neural protective mechanisms of lithium chloride.

60 APPLIED LIFE SCIENCES↗

Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters

Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiation (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.

disinfection↗

Radiation damage effects in chlorite investigated using microfocus synchrotron techniques

A detailed understanding of the mechanisms and effects of radiation damage in phyllosilicate minerals is a necessary component of the evaluation of the safety case for a deep geological disposal facility (GDF) for radioactive waste. Structural and chemical changes induced by a-particle damage will affect these mineral’s performance as a reactive barrier material (both in the near and far-field) over timescales relevant to GDF integrity. In this study, two examples of chlorite group minerals have been irradiated at a-particle doses comparable to those predicted to be experienced by the clay buffer material surrounding high level radioactive waste canisters. Crystallographic aberrations induced by the focused 4He2+ ion beam are revealed via high-resolution, microfocus X-ray diffraction mapping. Interlayer collapse by up to 0.5 Å is prevalent across both macro- and micro-crystalline samples, with the macro-crystalline specimen displaying a breakdown of the phyllosilicate structure into loosely-connected, multi-oriented crystallites displaying variable lattice parameters. The damaged lattice parameters suggest a localised breakdown and collapse of the OH- rich, ‘brucite-like’ interlayer. Microfocus Fe K-edge X-ray absorption spectroscopy illustrates this defect accumulation, manifest as a severe damping of the X-ray absorption edge. Subtle Fe2+/Fe3+ speciation changes are apparent across the damaged structures. A trend towards Fe reduction is evident at depth in the damaged structures at certain doses (8.76 x 1015 alpha particles/ cm2). Interestingly, this reductive trend does not increase with radiation dose, indeed at the maximum dose (1.26 x 1016 alpha particles/ cm2) administered in this study, there is evidence for a slight increase in Fe binding energy, suggesting the development of a depth-dependant redox gradient concurrent with light ion damage. At the doses examined here, these damaged structures are likely highly reactive, as sorption capacity will, to an extent, be largely enhanced by lattice disruption and an increase in available ‘edge’ sites.

Bower, William R.↗

Compact modeling of total ionizing dose and aging effects in MOS technologies

This paper presents a physics-based compact modeling approach that incorporates the impact of total ionizing dose (TID) and stress-induced defects into simulations of metal-oxide-semiconductor (MOS) devices and integrated circuits (ICs). This approach utilizes calculations of surface potential (ψs) to capture the charge contribution from oxide trapped charge and interface traps and to describe their impact on MOS electrostatics and device operating characteristics as a function of ionizing radiation exposure and aging effects. The modeling approach is demonstrated for bulk and silicon-on-insulator (SOI) MOS device. The formulation is verified using TCAD simulations and through the comparison of model calculations and experimental I-V characteristics from irradiated devices. The presented approach is suitable for modeling TID and aging effects in advanced MOS devices and ICs.

36 MATERIALS SCIENCE↗

Estimate of Undulator Magnet Damage Due to Beam Finder Wire Measurements

Beam Finder Wire (BFW) devices will be installed at each break in the Undulator magnet line. These devices will scan small wires across the beam causing some electrons to lose energy through bremsstrahlung. The degraded electrons are subsequently detected downstream of a set of vertical dipole magnets after they pass through the vacuum chamber. This signal can then be used to accurately determine the beam position with respect to the BFW wire. The choice of the wire diameter, scan speed, and operating parameters, depends on the trade-off between the signal size and the radiation damage to the undulator magnets. In this note I estimate the rate of undulator magnet damage that results from scanning as a function of, wire size, scan speed, and average beam current. A separate analysis of the signal size was carried out by Wu. The damage estimate is primarily based on two sources: the first, Fasso, is used to estimate the amount of radiation generated and then absorbed by the magnets; the second, Alderman et. al., is used to estimate the amount of damage the magnet undergoes as a result of the absorbed radiation. Fasso performed a detailed calculation of the radiation, including neutron fluence, that results from a the electron beam passing through a 100 micron diamond foil inserted just in front of the undulator line. Fasso discussed the signficance of various types of radiation and stated that photoneutrons probably play a major role. The estimate in this paper assumes the neutron fluence is the only significant cause of radiation-induced demagnetization. The specific results I use from Fasso's paper are reproduced here in Figure 1, which shows the radial distribution of the integrated neutron fluence per day in the undulator magnets, and Figure 2, which shows the absorbed radiation dose all along the undulator line. In the longitudinal dimension, Fasso's calculation, (see Figure 2), shows that the radiation dose is widely distributed all along the undulator line, but is highest around 70 m from the front of the undulator line where the foil is. At the 70 m point, for the purpose of calculating the demagnetization, I chose a conservative estimate for the effective neutron flux of 1.0 x 10{sup 13} n/cm{sup 2}/day. As can be seen in Figure 1, this choice is representative of the flux nearest the beam where it is the highest. A less conservative estimate, but perhaps more accurate, estimate of the effective flux, would be the average flux in the magnet block, which is roughly one half as much.

43 PARTICLE ACCELERATORS↗