Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

High Frequency Design Considerations for the Large Detector Number and Small Form Factor Dual Electron Spectrometer of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

Each half of the Dual Electron Spectrometer (DES) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission utilizes a microchannel plate Chevron stack feeding 16 separate detection channels each with a dedicated anode and amplifier/discriminator chip. The desire to detect events on a single channel with a temporal spacing of 100 ns and a fixed dead-time drove our decision to use an amplifier/discriminator with a very fast (GHz class) front end. Since the inherent frequency response of each pulse in the output of the DES microchannel plate system also has frequency components above a GHz, this produced a number of design constraints not normally expected in electronic systems operating at peak speeds of 10 MHz. Additional constraints are imposed by the geometry of the instrument requiring all 16 channels along with each anode and amplifier/discriminator to be packaged in a relatively small space. We developed an electrical model for board level interactions between the detector channels to allow us to design a board topology which gave us the best detection sensitivity and lowest channel to channel crosstalk. The amplifier/discriminator output was designed to prevent the outputs from one channel from producing triggers on the inputs of other channels. A number of Radio Frequency design techniques were then applied to prevent signals from other subsystems (e.g. the high voltage power supply, command and data handling board, and Ultraviolet stimulation for the MCP) from generating false events. These techniques enabled us to operate the board at its highest sensitivity when operated in isolation and at very high sensitivity when placed into the overall system.

Microchannel plates high frequency performance↗

Ultra-High-Frequency Capacitive Displacement Sensor

Improved class of compact, high-resolution capacitive displacement sensors operates at excitation frequency of 915 MHz and measures about 7.5 by 4 by 2 centimeters. Contains commercially available 915-MHz oscillator and transmission-line resonator. Resonator contains stripline inductor in addition to variable capacitor. Ultrahigh excitation frequency offers advantages of resolution and frequency response. Not deleteriously affected by mechanical overdriving, or contact between electrodes.

Vanzandt, Thomas R.↗

High frequency electromagnetic properties of interstitial-atom-modified Ce{sub 2}Fe{sub 17}N{sub X} and its composites

The magnetic and microwave absorption properties of the interstitial atom modified intermetallic compound Ce{sub 2}Fe{sub 17}N{sub X} have been investigated. The Ce{sub 2}Fe{sub 17}N{sub X} compound shows a planar anisotropy with saturation magnetization of 1088 kA/m at room temperature. The Ce{sub 2}Fe{sub 17}N{sub X} paraffin composite with a mass ratio of 1:1 exhibits a permeability of μ′ = 2.7 at low frequency, together with a reflection loss of −26 dB at 6.9 GHz with a thickness of 1.5 mm and −60 dB at 2.2 GHz with a thickness of 4.0 mm. It was found that this composite increases the Snoek limit and exhibits both high working frequency and permeability due to its high saturation magnetization and high ratio of the c-axis anisotropy field to the basal plane anisotropy field. Hence, it is possible that this composite can be used as a high-performance thin layer microwave absorber.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrasonic degradation of GenX (HFPO-DA) – Performance comparison to PFOA and PFOS at high frequencies

Sonolytic degradation kinetics of hexafluoropropylene oxide-dimer acid (HFPO-DA or GenX) were studied for the first time at four high ultrasonic frequencies (375, 580, 860 and 1,140kHz) and three power densities (200, 300 and 400W/L), and compared to the degradation of previously studied perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS). The frequency of 580kHz displayed the highest degradation of all three PFAS tested. Within each frequency, the degradation performance increased consistently with increasing power density. Degradation rates were highest for GenX over PFOA to PFOS (k GenX = 0.0501 min -1 , k PFOA = 0.0444 min -1 , k PFOS 0.0153 min -1 ), which is in direct agreement with their reported thermal stability (PFOS > PFOA > GenX). No known by-product formation as expected from the literature on truncation mechanism was detected in the samples (i.e. shorter chain carboxylic acid PFAS). Further, fluorine mass balance experiments at 580kHz and 400W/ L confirmed that GenX defluorinated fastest among the three tested PFAS and had lowest loss of fluorine in the mass balance. Degradation experiments with a mixture of all three PFAS displayed lower degradation rates than the individual experiments, where PFOA exhibited the largest reduction in degradation rate (by 31%), followed by GenX (by 19%), and finally by PFOS (by 17%). Overall, our study demonstrates that ultrasound can provide effective destruction of different PFAS (70-90% fluorine from mitigated PFAS was detected as inorganic fluoride) with a similar energy demand to alternative PFAS treatment methods reported in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High‐Frequency Intermittency in Observed and Model‐Simulated Precipitation

Abstract A newly reprocessed, bias‐corrected version of hourly satellite observations that provides global coverage of precipitation at high space‐time resolution is evaluated and compared with climate model simulations. Irregular subdaily fluctuations are the dominant component around the world, greater than variance of daily mean precipitation, and much greater than variance associated with the mean diurnal cycle of precipitation. Irregular subdaily fluctuations of precipitation are severely underestimated by models, even after taking into account the observational “error bars” implied by different space‐time resolutions. Variance of daily mean precipitation is less severely underestimated. Although mean diurnal cycle amplitudes vary among the models, this component is but a small part of total precipitation variance. Therefore, the total precipitation variance is significantly underestimated by models in general. Further exploration of model‐data discrepancies in precipitation at high‐time frequency may lead to new and useful climate model diagnostics.

54 ENVIRONMENTAL SCIENCES↗

Disc tearing leads to low and high frequency quasi-periodic oscillations in a GRMHD simulation of a thin accretion disc

Black hole X-ray binaries (BHXRBs) display a wide range of variability phenomena, from long duration spectral state changes to short-term broad-band variability and quasi-periodic oscillations (QPOs). A particularly puzzling aspect is the production of QPOs, which – if properly understood – could be used as a powerful diagnostic tool of black hole accretion and evolution. In this work, we analyse a high-resolution 3D general relativistic magnetohydrodynamic simulation of a geometrically thin accretion disc, which is tilted by 65° with respect to the black hole spin axis. We find that the Lense–Thirring torque from the rapidly spinning 10 M ⊙ black hole causes several sub-discs to tear off within ~10–20 gravitational radii. Tearing occurs in cycles on time-scales of seconds. During each tearing cycle, the inner sub-disc precesses for 1–5 periods before it falls into the black hole. We find a precession frequency of ~3 Hz, consistent with observed low-frequency QPOs. In addition, we find a high frequency QPO (HFQPO) with centroid frequency of ~55 Hz in the power spectra of the mass-weighted radius of the inner disc and the radial mass flux. This signal is caused by radial epicyclic oscillations of a dense ring of gas at the tearing radius, which suggests a corresponding modulation of the X-ray light curve and may thus explain some of the observed HFQPOs.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic softness and high-frequency characteristics of Fe{sub 65}Co{sub 35}-O alloy films

The effects of oxygen concentration and film thickness were studied on the microstructural, electrical, and magnetic properties of Fe{sub 65}Co{sub 35}-O alloy films prepared by dc magnetron sputtering at room temperature. The films showed the best magnetic softness with a large saturation magnetization of 21.5 kG, low coercivities of 2.8 and 2.1 Oe in easy and hard axes, respectively, and a high resistivity of 2215 muOMEGA cm at an optimized condition of an oxygen gas flow ratio of 1.0% and a film thickness of 105 nm. Such an excellent magnetic softness can be attributed to grain refinement caused by the addition of very low dose of oxygen, which basically did not lead to the full formation of Fe and/or Co oxide phases with low saturation magnetizations. The microwave permeability measurement indicated that the addition of very low dose of oxygen could improve the response of real permeability to frequency. A high real permeability of 525 at frequency up to 1.2 GHz was obtained for the Fe{sub 65}Co{sub 35}-O films deposited at the optimized condition above.

36 MATERIALS SCIENCE↗

HIGH-RESOLUTION RADIO OBSERVATIONS OF THE REMNANT OF SN 1987A AT HIGH FREQUENCIES

We present new imaging observations of the remnant of Supernova (SN) 1987A at 44 GHz, performed in 2011 with the Australia Telescope Compact Array (ATCA). The 0.''35 Multiplication-Sign 0.''23 resolution of the diffraction-limited image is the highest achieved to date in high-dynamic range. We also present a new ATCA image at 18 GHz derived from 2011 observations, which is super-resolved to 0.''25. The flux density is 40 {+-} 2 mJy at 44 GHz and 81 {+-} 6 mJy at 18 GHz. At both frequencies, the remnant exhibits a ring-like emission with two prominent lobes, and an east-west brightness asymmetry that peaks on the eastern lobe. A central feature of fainter emission appears at 44 GHz. A comparison with previous ATCA observations at 18 and 36 GHz highlights higher expansion velocities of the remnant's eastern side. The 18-44 GHz spectral index is {alpha} = -0.80 (S{sub {nu}}{proportional_to}{nu}{sup {alpha}}). The spectral index map suggests slightly steeper values at the brightest sites on the eastern lobe, whereas flatter values are associated with the inner regions. The remnant morphology at 44 GHz generally matches the structure seen with contemporaneous X-ray and H{alpha} observations. Unlike the H{alpha} emission, both the radio and X-ray emission peaks on the eastern lobe. The regions of flatter spectral index align and partially overlap with the optically visible ejecta. Simple free-free absorption models suggest that emission from a pulsar wind nebula or a compact source inside the remnant may now be detectable at high frequencies or at low frequencies if there are holes in the ionized component of the ejecta.

79 ASTRONOMY AND ASTROPHYSICS↗