Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Nearby Sites Show Similar Upwind Sources and Differing Semivolatile Concentrations in Coastal Aerosol Particles

The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) characterized aerosol composition using measurements at two sites within 3 km (Scripps Pier and Mt. Soledad) from 15 February 2023 to 14 February 2024. Comparing the two sites shows the strong influence of upwind sources that results in similar monthly compositions at both sites. The seasonal changes in chemical mass concentrations were largely driven by the upwind source regions, with coastal northwesterly back-trajectories occurring 63−65% of the year and bringing submicrometer mass concentrations that were lower than the EPCAPE average for all trajectories at each site. In contrast, refractory black carbon (rBC) and nonrefractory (NR)-organics and nitrate mass concentrations exceeded EPCAPE average concentrations for back-trajectories from urban areas such as Los Angeles-Long Beach. For hourly measurements, NR-organics and non-sea-salt (NSS)-sulfate mass concentrations at Mt. Soledad were correlated strongly (r = 0.73−0.82) to those measured at Scripps Pier, but NR-nitrate was correlated only moderately (r = 0.63). The explanation for the lower correlation of NR-nitrate is both emissions between the sites and semivolatility, with semivolatility accounting for site-to-site changes in daily averages of +0.01 μg m −3 per percentage site-to-site difference in relative humidity and −0.07 μg m −3 per degree Celsius site-to-site difference in temperature. On average, comparing Scripps Pier to Mt. Soledad, NR-nitrate was higher by 29% because of relative humidity and lower by −26% because of temperature. NR-nitrate and rBC mass concentrations at Scripps Pier for nighttime were 13−15% higher than those for daytime because land breezes brought higher inland concentrations. Concentrations of rBC were 52% higher at Mt. Soledad than those measured at Scripps Pier, accompanied by increases in tracers for brake wear because of traffic on the steep roads within 10 m of that site. The implications are that these nearby sites had comparable monthly concentrations of measured components due to their similar backtrajectories, but hourly and daily concentration differences supported quantification of the meteorological effects from relative humidity and temperature on semivolatile NR-nitrate as well as minor differences from land−sea breezes and local emissions.

Aerosols↗

Changes in Convective Available Potential Energy and Convective Inhibition under Global Warming

Atmospheric convective available potential energy (CAPE) is expected to increase under greenhouse gas–induced global warming, but a recent regional study also suggests enhanced convective inhibition (CIN) over land although its cause is not well understood. In this study, a global climate model is first evaluated by comparing its CAPE and CIN with reanalysis data, and then their future changes and the underlying causes are examined. The climate model reasonably captures the present-day CAPE and CIN patterns seen in the reanalysis, and projects increased CAPE almost everywhere and stronger CIN over most land under global warming. Over land, the cases or times with medium to strong CAPE or CIN would increase while cases with weak CAPE or CIN would decrease, leading to an overall strengthening in their mean values. These projected changes are confirmed by convection-permitting 4-km model simulations over the United States. The CAPE increase results mainly from increased low-level specific humidity, which leads to more latent heating and buoyancy for a lifted parcel above the level of free convection (LFC) and also a higher level of neutral buoyancy. The enhanced CIN over most land results mainly from reduced low-level relative humidity (RH), which leads to a higher lifting condensation level and a higher LFC and thus more negative buoyancy. Over tropical oceans, the near-surface RH increases slightly, leading to slight weakening of CIN. Over the subtropical eastern Pacific and Atlantic Ocean, the impact of reduced low-level atmospheric lapse rates overshadows the effect of increased specific humidity, leading to decreased CAPE.

54 ENVIRONMENTAL SCIENCES↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Empirical prediction of saline water atomization pressure loss and spray phase change using local flow pressure analysis

A pressure analysis technique was developed to obtain spray spatial evaporation profile in a thermal desalination process. The technique can replace temperature-based evaporation measurement methods that are challenged by liquid-phase interference. It also provides an alternative to optical methods with high cost and complexity. Fundamental analysis was developed to determine local humidity ratios from changes in local static and dynamic pressures. The analysis was applied to data obtained from an external mixing air-assist atomizer. An empirical model was developed for the pressure loss in atomization process and was used in the analysis of humidity ratio. The results were used to develop empirical correlations for local humidity ratio in spray mediums using inlet conditions. Utilizing inlet conditions to predict evaporation profiles is an important contribution as it eliminates the need to take local spray measurements. Obtaining local data is often difficult and expensive; Our method and correlation circumvent the need for that. Finally, the correlations presented in this paper apply to saline water sprays with total dissolved salt of 0-10 wt%. The salinity-specific correlations are accurate to within ±10% of experimental data. The individual models were aggregated into a unified correlation for salinities within 0-10 wt%. The unified correlation is accurate to within ±18% of experimental data.

42 ENGINEERING↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Hygroscopic growth of UO 2 F 2 nanoparticles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 nanoparticle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Although the largest size of UO 2 F 2 nanoparticles was 80 nm, monodisperse aerosol with a mobility diameter of up to approximately 500 nm can be investigated using the HTDMA. Anhydrous UO 2 F 2 nanoparticles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter from 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. Here, these results demonstrate the hygroscopic properties of UO 2 F 2 nanoparticles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 nanoparticles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 nanoparticles in the atmosphere.

Hygroscopicity↗

Supported ionic liquid membranes (SILMs) with exceptional selectivity and permeability for dilute CO 2 separations

Supported ionic liquid membranes (SILMs), containing phosphonium ionic liquids with aprotic N-heterocyclic anions (AHA ILs) in an inert inorganic support, were tested under both dry and humidified (40 % RH) mixed-gas conditions down to 420 ppm CO 2 in N 2 at 35 °C. In the dry case, the best performing IL, triethyl(octyl)phosphonium 4-bromopyrazolide ([P 2228 ][4-BrPyra]) exhibited mixed-gas CO 2 permeabilities and CO 2 /N 2 permeability selectivities as high as 26,800 barrer and 7,000, respectively. In the presence of humidity, the CO 2 permeability and CO 2 /N 2 selectivity increased to 49,100 barrer and 13,200, respectively, and these are the highest reported combination in the literature. Humidity amplifies CO 2 permeabilities and CO 2 /N 2 permeability selectivities through increases in CO 2 capacity due to bicarbonate formation and through faster mobility of the mobile carrier from decreased viscosity. Furthermore, N 2 permeability stayed roughly invariant in the presence of humidity, likely from competing effects of viscosity reduction and lower N 2 solubility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced ZIF-8-enabled colorimetric CO 2 sensing through dye-precursor synthesis

The accumulation of carbon dioxide (CO 2 ) within enclosed spaces, along with volatile organic compounds, under certain humidity, temperature, and ventilation conditions is associated with detrimental human health symptoms such as fatigue. Color-based chemical sensing is a promising approach to detect CO 2 levels relevant to indoor air quality through producing fast, quantifiable output visible to the naked eye. In a prior work, a colorimetric gas sensor was fabricated through synthesizing the metal-organic framework, ZIF-8, as the adsorbent, followed by post-synthetic mixing with a dye, phenol red (PSP), and primary amine, ethylenediamine (ED). While this sensor (termed PSP-ED/ZIF-8) maintained its structural integrity in atmospheric conditions and exhibited an increasing fuchsia-to-yellow color change with increasing CO 2 levels in dry environment, the colorimetric response greatly suffered in the presence of humid CO 2 . Here in this work, a significantly improved colorimetric CO 2 sensor (referred to as ED/PSP:ZIF-8) is accomplished through directly incorporating phenol red in the ZIF-8 metal and linker precursor solutions and then blending with ethylenediamine. MATLAB-generated color distributions and in-situ ultraviolet-visible (UV-Vis) spectroscopic studies quantitatively demonstrate an enhanced colorimetric gas response of ED/PSP:ZIF-8 compared to that of PSP-ED/ZIF-8 across an important range of CO 2 for indoor air quality monitoring (500 – 3500 ppm) and across a range of humidity. The new sensor also exhibits high selectivity to CO 2 compared to select volatile organic compounds, such as acetone and ethanol, which contribute to human health symptoms experienced indoors. The enhanced performance is attributed to the proposed incorporation of phenol red within ZIF-8, while maintaining the chemical stability of the MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contrasting effects of lake breeze and urbanization on heat stress in Chicago metropolitan area

This study used the latest Weather Research and Forecasting (WRF) model coupled with multi -layer urban canopy models to investigate contrasting effects from urbanization and lake breeze on summer heat stress over the Chicago metropolitan area (CMA). Comparisons between the model and in situ observations show that this coupled modeling system better captures urban locations' diurnal pattern of surface air temperature, skin temperature and relative humidity, with root mean square error reduced from 1.58 to 1.80 degrees C to 1.14-1.31 degrees C, 3.11-3.55 degrees C to 1.81-2.21 degrees C, and 10.73-11.35% to 7.84-8.60%, respectively, compared to WRF without coupling the urban canopy models. Two sensitivity experiments were conducted to isolate the influence of lake breeze and urbanization: one replaced the urban land use with cropland over the CMA, and the other filled all of Lake Michigan with cropland. Three different heat stress indices were computed to assess the uncertainties of heat stress response to changes in air temperature, relative humidity, and wind conditions. Results show that, when the lake has the largest cooling effect on air temperature, it also increases the relative humidity the most, and vice versa for urban warming and drying effects. Urbanization intensifies heat stress at night, and extends the heat caution period by up to 4 h over inland urban grids; the lake breeze relieves heat stress during afternoon (when the heat stress is the worst), and shortens the heat caution period by 1-3 h over inland urban grids and 3-4 h over coastal urban grids. In conclusion, the intensification of heat stress over the CMA due to urbanization is more than four times greater than the reduction from the lake breeze in the late afternoon and evening.

54 ENVIRONMENTAL SCIENCES↗

Multilayer Chitin–Chitosan–Cellulose Barrier Coatings on Poly(ethylene terephthalate)

Currently, effective barrier properties over a wide range of humidity are achieved by layering multiple plastics, resulting in structures that are nearly impossible to recycle through current systems. There is strong interest in developing barriers that are recyclable, biodegradable, or compostable. Chitin and cellulose nanomaterials are promising alternatives because of their high crystallinity, renewable sourcing, strong electrostatic interactions, and potential for biodegradation or composting. In this paper, we explore the potential to create multilayer materials with effective oxygen and water vapor barrier properties at elevated humidity by combining recyclable poly(ethylene terephthalate) (PET) films with single-layer and bilayer coatings of chitin nanowhiskers (ChNWs), chitosan (CS), and cellulose nanocrystals (CNCs). The addition of CS to the ChNW suspension improved the gas barrier properties of ChNW coatings, likely by filling voids, and short ChNWs (SChNW, 114 nm) performed better than long ChNWs (LChNW, 230 nm). At the optimal mass ratio of 1:1 SChNW/CS, the oxygen permeability (OP) of SChNW/CS-coated PET films was 5.1 cm 3 μm m –2 day –1 kPa –1 versus 15.9 cm 3 μm m –2 day –1 kPa –1 for neat PET. To take advantage of electrostatic attraction and hydrogen bonding, CNC was first coated on the PET, followed by coating with ChNW/CS, resulting in an OP as low as 3.6 cm 3 μm m –2 day –1 kPa –1 at 50% relative humidity (RH), and 6.4 cm 3 μm m –2 day –1 kPa –1 at 80% RH. Furthermore, after thermal treatment (120 °C, 2.5 h), the OP dropped to 2.2 cm 3 μm m –2 day –1 kPa –1 (50% RH) and 4.8 cm 3 μm m –2 day –1 kPa –1 (80% RH). The ChNW/CS and CNC coating can be efficiently removed with alkali treatment enabling possible recycling of the coated PET films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can N95 Respirators Be Reused after Disinfection? How Many Times?

The coronavirus disease 2019 (COVID-19) pandemic has led to a major shortage of N95 respirators, which are essential for protecting healthcare professionals and the general public who may come into contact with the virus. Thus, it is essential to determine how we can reuse respirators and other personal protective equipment in these urgent times. We investigated multiple commonly used disinfection schemes on media with particle filtration efficiency of 95%. Heating was recently found to inactivate the virus in solution within 5 min at 70 °C and is among the most scalable, user-friendly methods for viral disinfection. We found that heat (≤85 °C) under various humidities (≤100% relative humidity, RH) was the most promising, nondestructive method for the preservation of filtration properties in meltblown fabrics as well as N95-grade respirators. At 85 °C, 30% RH, we were able to perform 50 cycles of heat treatment without significant changes in the filtration efficiency. At low humidity or dry conditions, temperatures up to 100 °C were not found to alter the filtration efficiency significantly within 20 cycles of treatment. Ultraviolet (UV) irradiation was a secondary choice, which was able to withstand 10 cycles of treatment and showed small degradation by 20 cycles. However, UV can potentially impact the material strength and subsequent sealing of respirators. Finally, treatments involving liquids and vapors require caution, as steam, alcohol, and household bleach all may lead to degradation of the filtration efficiency, leaving the user vulnerable to the viral aerosols.

60 APPLIED LIFE SCIENCES↗

A New Approach for Simultaneous Estimation of Entrainment and Detrainment Rates in Non- Precipitating Shallow Cumulus

A new approach is developed for estimating entrainment and detrainment rates in cumulus clouds based on aircraft observations. Equations relating entrainment and detrainment rates to gross entrainment and detrainment are derived. This approach is applied to the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems field campaign, supported by the U.S. Department of Energy's Atmospheric Radiation Measurement program. The results show that both entrainment and detrainment rates decrease with increasing height. Sensitivity tests with different detrained air assumptions yield similar results. The entrainment and detrainment rates can reproduce the cloud thermodynamic variables. Partial correlation analysis indicates that entrainment rate is positively correlated with environmental relative humidity (RH), and detrainment rate is negatively correlated with environmental RH and positively correlated with entrainment rate. This new approach can be applied to other cloud observations to obtain a data set of entrainment and detrainment rates in cumulus clouds.

Zhu, Lei↗

Factors Affecting Entrainment Rate in Deep Convective Clouds and Parameterizations

The parameterization of cloud entrainment rates has been problematic for many years, hindering the accurate representation of convective processes in large-scale models. Here, we extend our previous work on individual shallow convection to ensemble deep convection. Entrainment rates are estimated based on three-dimensional convective clouds from August 19-20 of 1999, during the Kwajalein Experiment, simulated using a high-resolution cloud-resolving model. They are found to be negatively correlated with both vertical velocity and buoyancy, and positively correlated with the vertical divergence of the vertical velocity and with the reciprocal of cloud radii. The physical mechanisms underlying these relationships are interpreted. It is found that the parameterizations with multiple properties perform better than those with a single property. Entrainment rates and relative humidity of entrained air are positively correlated at temperature higher than 0°C, but negatively correlated at temperature lower than 0°C. Relative humidity is also included in the parameterization of entrainment rates, which differs from our previous work on shallow cumulus clouds and other studies. Finally, two forms of parameterization for entrainment rate are recommended. The first treats the entrainment rate as a function of the vertical velocity and buoyancy for temperature higher than 0°C, but as a function of relative humidity and buoyancy for temperature lower than 0°C. The second involves an equation that relates entrainment rates to vertical velocity and buoyancy regardless of temperature.

54 ENVIRONMENTAL SCIENCES↗

Experimental Determination of the Relationship Between Organic Aerosol Viscosity and Ice Nucleation at Upper Free Tropospheric Conditions

Abstract This work presents measurements of the ice nucleating ability of secondary organic material recorded between −40 and −70°C and relative humidity with respect to ice (RH ice ) between 150% and 220%. For a subset of systems, temperature and humidity dependence of particle viscosity as well as dry glass transition temperature were characterized using the dual tandem differential mobility analyzer method. Eleven unique monoterpene, sesquiterpene and aromatic precursors were used to generate secondary organic material (SOM) using either an oxidation flow reactor (OFR) or an environmental chamber (EC). For the SOM for which viscosity was measured, the particle glass transition temperatures varied between 6 and 23°C ( n = 8). Measurements were performed to verify that increased relative humidity did not plasticize the particles below −10°C at residence times similar to those in the ice nucleation instrument. No heterogeneous ice nucleation was observed at the ∼0.5% onset threshold for any of the materials generated. The ice nucleation occurs by the freezing of SOM solution droplets consistent with homogeneous freezing indicating that they form an aqueous solution, or the SOM particles required water saturation to freeze, indicating that they were hydrophobic. Experiments exploring the influence of functional groups and mass loading did not reveal any obvious influence of particle chemistry or generation conditions on the results. Close structural matches between known organic ice nucleating particles as precursor or formed products did not yield materials that promoted freezing. These experiments suggest that heterogeneous ice formation of glassy secondary organic materials is likely uncommon under upper free tropospheric conditions.

54 ENVIRONMENTAL SCIENCES↗