Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Static and dynamic topological defects in the domain textures in the helical antiferromagnet Ni 2 ⁢CoTeO 6

Real-space Bragg coherent x-ray-diffractive imaging unveils the formation of bubble and stripe antiferromagnetic (AFM) phase domains on the surface of Ni 2 ⁢CoTeO 6 single crystal. The stripe domains exhibit dislocation-type topological defects. The defects typically form as defect-antidefect pairs and can be created or annihilated by temperature changes and local heating. Thermal fluctuations of the AFM domain walls are observed near the Néel temperature. Topological defect pairs dynamically form and disappear in the fluctuating state. These observations provide a real-space perspective on the dynamics of the AFM phase transition in a helical antiferromagnet. Finally, the remarkable tunability of AFM domain walls in a helical antiferromagnet underscores their potential for AFM spintronics applications.

36 MATERIALS SCIENCE↗

EuCo 2 P 2 : A Model Molecular-Field Helical Heisenberg Antiferromagnet

The metallic compound EuCo 2 P 2 with the body-centered tetragonal ThCr 2 Si 2 structure containing Eu spins-7/2 was previously shown from single-crystal neutron diffraction measurements to exhibit a helical antiferromagnetic (AFM) structure below T N =66.5 K with the helix axis along the c axis and with the ordered moments aligned within the ab plane. Here we report crystallography, electrical resistivity, heat capacity, magnetization, and magnetic susceptibility measurements on single crystals of this compound. We demonstrate that EuCo 2 P 2 is a model molecular-field helical Heisenberg antiferromagnet from comparisons of the anisotropic magnetic susceptibility χ, high-field magnetization, and magnetic heat capacity of EuCo 2 P 2 single crystals at temperature T≤TN with the predictions of our recent formulation of molecular-field theory. Values of the Heisenberg exchange interactions between the Eu spins are derived from the data. The low-T magnetic heat capacity ~T 3 arising from spin-wave excitations with no anisotropy gap is calculated and found to be comparable to the lattice heat capacity. The density of states at the Fermi energy of EuCo 2 P 2 and the related compound BaCo 2 P 2 are found from the heat capacity data to be large, 10 and 16 states/eV per formula unit for EuCo 2 P 2 and BaCo 2 P 2 , respectively. These values are enhanced by a factor of ~2.5 above those found from DFT electronic structure calculations for the two compounds. Additionally, the calculations also find ferromagnetic Eu–Eu exchange interactions within the ab plane and AFM interactions between Eu spins in nearest- and next-nearest planes, in agreement with the MFT analysis of χ ab (T≤TN).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of double-helicity asymmetries in inclusive J / ψ production in longitudinally polarized p + p collisions at s = 510 GeV

We report the double-helicity asymmetry, A J/ψ LL , in inclusive J/ψ production at forward rapidity as a function of transverse momentum p T and rapidity |y|. The data analyzed were taken during √s = 510 GeV longitudinally polarized p + p collisions at the Relativistic Heavy Ion Collider in the 2013 run using the PHENIX detector. At this collision energy, J/ψ particles are predominantly produced through gluon-gluon scatterings, thus A J/ψ LL is sensitive to the gluon polarization inside the proton. We measured A J/ψ LL by detecting the decay daughter muon pairs μ + μ – within the PHENIX muon spectrometers in the rapidity range 1.2 < |y| < 2.2. In this kinematic range, we measured the A J/ψ LL to be 0.012 ± 0.010 (stat) ±0.003 (syst). The A J/ψ LL can be expressed to be proportional to the product of the gluon polarization distributions at two distinct ranges of Bjorken x: one at moderate range x ≈ 5 × 10 –2 where recent data of jet and π 0 double helicity spin asymmetries have shown evidence for significant gluon polarization, and the other one covering the poorly known small-x region x ≈ 2 × 10 –3 . Furthermore, our new results could be used to further constrain the gluon polarization for x < 5 × 10 –2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Helicity evolution at small x : Flavor singlet and nonsinglet observables

We extend our earlier results for the quark helicity evolution at small x to derive the small-x asymptotics of the flavor singlet and flavor nonsinglet quark helicity TMDs and PDFs and of the g 1 structure function. In the flavor singlet case we rederive the evolution equations obtained in our previous paper on the subject, performing additional cross-checks of our results. In the flavor nonsinglet case we construct new small-x evolution equations by employing the large-N c limit. Here, all evolution equations resum double-logarithmic powers of α s ln 2 (1/x) in the polarization-dependent evolution along with the single-logarithmic powers of α s ln(1/x) in the unpolarized evolution which includes saturation effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved measurements of two-photon widths of the χ c J states and helicity analysis for χ c 2 → γ γ

Based on 448.1 x 10 6 ψ(3686) events collected with the BESIII detector, the decays ψ(3686) → γχ cJ ,χ cJ → γγ(J = 0,1,2) are studied in this paper. The decay branching fractions of χ c0,2 → γγ are measured to be β(χ c0 → γγ) = (1.93 ± 0.08 ± 0.05 ± 0.05) x 10 -4 and β(χ c2 → γγ) = (3.10 ± 0.09 ± 0.07 ± 0.11) x 10 -4 , which correspond to two-photon decay widths of Γ γγ (χ c0 ) = 2.03 ± 0.08 ± 0.06 ± 0.13 keV and Γ γγ (χ c2 ) = 0.60 ± 0.02 ± 0.01 ± 0.04 keV with a ratio of R = Γ γγ (χ c2 )/Γ γγ (χ c0 ) = 0.295 ± 0.014 ± 0.007 ± 0.027, where the uncertainties are statistical, systematic and associated with the uncertainties of β(ψ(3686) → γχ c0,2 ) and the total widths Γ(χ c0,2 ), respectively. For the forbidden decay of χ c1 → γγ, no signal is observed, and an upper limit on the two-photon width is obtained to be Γ γγ (χ c1 ) < 5.3 eV at the 90% confidence level. Finally, the ratio of the two-photon widths between helicity-zero and helicity-two components in the decay χ c2 → γγ is also measured to be f 0/2 = Γ λ=0 γγ (χ c2 )/Γ λ=2 γγ (χ c2 ) = (0.0 ± 0.6 ± 1.2) x 10 -2 , where the uncertainties are statistical and systematic, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tokamak Magnetohydrodynamic Equilibrium States with Axisymmetric Boundary and a 3D Helical Core

Magnetohydrodynamic (MHD) equilibrium states with imposed axisymmetric boundary are computed in which a spontaneous bifurcation develops to produce an internal three-dimensional (3D) configuration with a helical structure in addition to the standard axisymmetric system. Equilibrium states with similar MHD energy levels are shown to develop very different geometric structures. The helical equilibrium states resemble saturated internal kink mode structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small- x asymptotics of the quark helicity distribution

We construct a numerical solution of the small-x evolution equations derived in our recent work for the (anti)quark transverse momentum dependent helicity TMDs and parton distribution functions (PDFs) as well as the g 1 structure function. We focus on the case of large N c , where one finds a closed set of equations. Employing the extracted intercept, we are able to predict directly from theory the behavior of the quark helicity PDFs at small x, which should have important phenomenological consequences. Finally, we also give an estimate of how much of the proton’s spin carried by the quarks may be at small x and what impact this has on the spin puzzle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interplay of Chiral and Helical States in a Quantum Spin Hall Insulator Lateral Junction

Here, we study the electronic transport across an electrostatically-gated lateral junction in a HgTe quantum well, a canonical 2D topological insulator, with and without applied magnetic field. We control carrier density inside and outside a junction region independently and hence tune the number and nature of 1D edge modes propagating in each of those regions. Outside the 2D gap, magnetic field drives the system to the quantum Hall regime, and chiral states propagate at the edge. In this regime, we observe fractional plateaus which reflect the equilibration between 1D chiral modes across the junction. As carrier density approaches zero in the central region and at moderate fields, we observe oscillations in resistance that we attribute to Fabry-Perot interference in the helical states, enabled by the broken time reversal symmetry. At higher fields, those oscillations disappear, in agreement with the expected absence of helical states when band inversion is lifted.

36 MATERIALS SCIENCE↗

Crystalline-Symmetry-Protected Helical Majorana Modes in the Iron Pnictides

We propose that propagating one-dimensional Majorana fermions will develop in the vortex cores of certain iron-based superconductors, most notably Li(Fe 1–x Co x ) As. A key ingredient of this proposal is the 3D Dirac cones recently observed in photoemission experiments. Using an effective Hamiltonian around the Γ–Z line we demonstrate the development of gapless one-dimensional helical Majorana modes, protected by C 4 symmetry. A topological index is derived which links the helical Majorana modes to the presence of monopoles in the Berry curvature of the normal state. Finally, we present various experimental consequences of this theory and discuss its possible connections with cosmic strings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Helical Shear-Flow Stabilization of an Astrophysically Relevant Laboratory Plasma Jet

Astrophysical jets are collimated, high-speed outflows observed to be natural features of celestial objects that spin and accrete matter. From protoplanetary nebula and young stellar objects to active galactic nuclei, common features suggest that universal mechanisms may lead to the remarkable straightness observed in many jets. Here we report observations from a new astrophysically relevant laboratory plasma jet experiment demonstrating the formation of long-lived, collimated, high aspect-ratio jets. The magnetized jets have strong helical shear flows and remain stable to instabilities over many growth times. These observations corroborate theoretical predictions that strong helical shear flows can stabilize current-driven instabilities in magnetically confined plasmas, solar prominences, and magnetically driven astrophysical jets in nature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helical versus collinear antiferromagnetic order tuned by magnetic anisotropy in polar and chiral (Ni,Mn) 3 TeO 6

In this work, polar and chiral Ni 3 TeO 6 was found to exhibit a colossal magnetoelectric (ME) effect associated with collinear antiferromagnetic order. We have investigated the evolution of its magnetic state with the substitution of the Ni 2+ spins by isotropic Mn 2+ spins, namely (Ni, Mn) 3 TeO 6 (NMTO). The ground state of NMTO maintains an Ising nature, but a new phase with XY-type magnetic anisotropy is discovered at an intermediate temperature range. Neutron powder diffraction experiments reveal that (1) Mn ions tend to occupy a specific transition-metal site, consistent with the first-principle calculation, and (2) the intermediate phase is an incommensurate (IC) helical magnetic state propagating along the $\textit{c}$ axis with $\vec q_{\text{IC}}$ = (0, 0, 1.5 ± δ). We also found that the balance between these two magnetic states can be readily manipulated with magnetic fields, which results in significant ME effects. This selective site occupancy of NMTO allows for a unique competition between collinear and helical magnetic structures with minimal chemical disorder. Thus, NMTO serves as a model system to study site-specific chemical control of noncollinear magnetism and ME coupling.

36 MATERIALS SCIENCE↗

Stripe helical magnetism and two regimes of anomalous Hall effect in NdAlGe

Here, we report the magnetic and electronic transport properties of the inversion and time-reversal symmetry breaking Weyl semimetal NdAlGe. This material is analogous to NdAlSi, whose helical magnetism presents a rare example of a Weyl-mediated collective phenomenon, but with a larger spin-orbit coupling. Our neutron diffraction experiments revealed that NdAlGe, similar to NdAlSi, supports an incommensurate spin density wave (T inc =6.8 K) whose spins are predominantly pointing along the out-of-plane direction and have a small helical spin canting of 3°. The spin density wave has a long wavelength of ≈35 nm and transitions to a commensurate ferrimagnetic state below T com =5.1K. Using small-angle neutron scattering, we showed that the zero-field cooled ferrimagnetic domains form stripes in real space with characteristic length scales of 18 and 72 nm parallel and perpendicular to the [110] direction, respectively. Interestingly, for the transport properties, NdAlSi does not exhibit an anomalous Hall effect (AHE) that is commonly observed in magnetic Weyl semimetals. In contrast to NdAlSi, we identify two different AHE regimes in NdAlGe that are, respectively, governed by intrinsic Berry curvature and extrinsic disorders/spin fluctuations. Our paper suggests that Weyl-mediated magnetism prevails in this group of noncentrosymmetric magnetic Weyl semimetals NdAlX, but transport properties including AHE are affected by material-specific extrinsic effects such as disorders, despite the presence of prominent Berry curvature.

36 MATERIALS SCIENCE↗

Lattice QCD Benchmark of Proton Helicity and Flavor-Dependent Unpolarized Transverse Momentum-Dependent Parton Distribution Functions at Physical Quark Masses

We present the first lattice QCD calculations of the isovector helicity transverse momentum-dependent parton distribution function (TMDPDF) and the flavor-dependent unpolarized TMDPDFs for up and down quarks in the proton. Our computations utilize domain-wall fermion discretization with physical quark masses. Employing Coulomb-gauge-fixed quark correlation functions within the large-momentum effective theory framework, we access nonperturbative transverse quark separations 𝑏 𝑇 up to approximately 1 fm, corresponding to transverse momenta as low as 200 MeV. Based on the quasi-TMD factorization theorem, we construct renormalization-group–invariant ratios that are equal to the corresponding light-cone TMDPDF ratios. At moderate 𝑥, our results reveal that the isovector helicity and unpolarized TMDPDFs exhibit nearly identical transverse structure up to a normalization factor, and the unpolarized distributions display only mild flavor dependence. These findings not only support key trends observed in recent global analyses but also provide robust, nonperturbative constraints that can distinguish between different parameterizations. This Letter establishes a first-principles benchmark for TMDPDFs, offering valuable input for ongoing and future experimental efforts to map the proton’s three-dimensional structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dosimetric verification of helical tomotherapy for total scalp irradiation

Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for a helical tomotherapy total scalp irradiation have been measured on an anthropomorphic phantom using radiochromic and radiographic film as well as a new skin dosimeter, the MOSkin. The superficial dose was found to be accurately calculated by the TomoTherapy planning system. This is in contrast to recent reports, probably due to a combination of the smaller dose grid resolution used in planning and this particular treatment primarily consisting of beamlets tangential to the scalp. The superficial dose was found to increase from 33.6 to 41.2 Gy and 36.0 to 42.0 Gy over the first 2 mm depth in the phantom in selected regions of the PTV, measured with radiochromic film. The prescription dose was 40 Gy. The superficial dose was at the prescription dose or higher in some regions due to the bolus effect of the thermoplastic head mask and the head rest used to aid treatment setup. It is suggested that to achieve the prescription dose at the surface ({<=}2 mm depth) bolus or a custom thermoplastic helmet is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reducing radiation dose to selected organs by selecting the tube start angle in MDCT helical scans: A Monte Carlo based study

Purpose: Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of ''hot'' spots or ''cold'' spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans. Methods: Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCT scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene. Dose to fetus was also estimated using four pregnant female models based on CT images of the pregnant patients. Whole-body scans were simulated using 120 kVp, 300 mAs, both 28.8 and 40 mm nominal collimations, and pitch values of 1.5, 1.0, and 0.75 under a wide range of start angles (0 deg. - 340 deg. in 20 deg. increments). The relationship between tube start angle and organ dose was examined for each organ, and the potential dose reduction was calculated. Results: Some organs exhibit a strong dose variation, depending on the tube start angle. For small peripheral organs (e.g., the eye lenses of the Baby phantom at pitch 1.5 with 40 mm collimation), the minimum dose can be 41% lower than the maximum dose, depending on the tube start angle. In general, larger dose reductions occur for smaller peripheral organs in smaller patients when wider collimation is used. Pitch 1.5 and pitch 0.75 have different mechanisms of dose reduction. For pitch 1.5 scans, the dose is usually lowest when the tube start angle is such that the x-ray tube is posterior to the patient when it passes the longitudinal location of the organ. For pitch 0.75 scans, the dose is lowest when the tube start angle is such that the x-ray tube is anterior to the patient when it passes the longitudinal location of the organ. Conclusions: Helical MDCT scanning at pitch 1.5 and pitch 0.75 results in ''cold spots'' and ''hot spots'' that are created both at surface and in-depth locations within patients. For organs that have a relatively small longitudinal extent, dose can vary considerably with different start angles. While current MDCT systems do not provide the user with the ability to control the tube start angle, these results indicate that in these specific situations (pitch 1.5 or pitch 0.75, small organs and especially small patients), there could be significant dose savings to organs if that functionality would be provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beam commissioning and measurements validating the beam model in a new TPS that converts helical tomotherapy plans to step-and-shoot IMRT plans

Purpose: A new type of treatment planning system called SHAREPLAN has been studied, which enables the transfer of treatment plans generated for helical tomotherapy delivery to plans that can be delivered on C-arm linacs. The purpose is to ensure continuous patient treatment during periods of unscheduled downtime for the TomoTherapy unit, particularly in clinics without a backup unit. The purpose of this work was to verify that the plans generated in this novel planning system are deliverable and accurate. The work consists primarily of beam commissioning, verification of the beam model, and measurements verifying that generated plans are deliverable with sufficient accuracy. Methods: The beam commissioning process involves input of general geometric properties of the modeled linac, profiles and depth dose curves for a specific photon nominal energy (6 MV), and the automated modeling of other beam properties. Some manual tuning of the beam model is required. To evaluate its accuracy, the confidence limit concept [J. Venselaar et al., ''Tolerances for the accuracy of photon beam dose calculations of treatment planning systems,'' Radiother. Oncol. 60, 191-201 (2001)] was used, which is a method supported by ESTRO. Measurements were conducted with a 2D diode array at the commissioned linac as a final check of the beam model and to evaluate whether the generated plans were deliverable and accurate. Results: The comparison and evaluation of calculated data points and measured data according to the method applied confirmed the accuracy of the beam model. The profiles had a confidence limit of 1.1% and the depth dose curves had a confidence limit of 1.7%, both of which were well below the tolerance limit of 2%. Plan specific QC measurements and evaluation verified that different plans generated in the TPS were deliverable with sufficient accuracy at the commissioned linac, as none of the 160 beams for the 20 different plans evaluated had a fraction of approved data points below 90%, the local clinical approval criterion for delivery QA measurements. Conclusions: This study is a validation of the new TPS as it verifies that the generated plans are deliverable at a commissioned linac with adequate accuracy. A thorough investigation of the treatment plan quality will require a separate study. The TPS is proving to be a useful and time-saving complement, especially for clinics having a single unit for helical delivery among its conventional linacs.

43 PARTICLE ACCELERATORS↗

Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc

Purpose: The commercial release of volumetric modulated arc therapy techniques using a conventional linear accelerator and the growing number of helical tomotherapy users have triggered renewed interest in dose verification methods, and also in tools for exploring the impact of machine tolerance and patient motion on dose distributions without the need to approximate time-varying parameters such as gantry position, MLC leaf motion, or patient motion. To this end we have developed a Monte Carlo-based calculation method capable of simulating a wide variety of treatment techniques without the need to resort to discretization approximations. Methods: The ability to perform complete position-probability-sampled Monte Carlo dose calculations was implemented in the BEAMnrc/DOSXZYnrc user codes of EGSnrc. The method includes full accelerator head simulations of our tomotherapy and Elekta linacs, and a realistic representation of continous motion via the sampling of a time variable. The functionality of this algorithm was tested via comparisons with both measurements and treatment planning dose distributions for four types of treatment techniques: 3D conformal, step-shoot intensity modulated radiation therapy, helical tomotherapy, and volumetric modulated arc therapy. Results: For static fields, the absolute dose agreement between the EGSnrc Monte Carlo calculations and measurements is within 2%/1 mm. Absolute dose agreement between Monte Carlo calculations and treatment planning system for the four different treatment techniques is within 3%/3 mm. Discrepancies with the tomotherapy TPS on the order of 10%/5 mm were observed for the extreme example of a small target located 15 cm off-axis and planned with a low modulation factor. The increase in simulation time associated with using position-probability sampling, as opposed to the discretization approach, was less than 2% in most cases. Conclusions: A single Monte Carlo simulation method can be used to calculate patient dose distribution for various types of treatment techniques delivered with either tomotherapy or a conventional linac. The method simplifies the simulation process, improves dose calculation accuracy, and involves an acceptably small change in computation time.

60 APPLIED LIFE SCIENCES↗