Apparatus for measuring high-flux heat transfer in radiatively heated compact exchangers

An apparatus is described which can deliver uniform heat flux densities of up to 80 W/sq cm over an area 7.8 cm x 15.2 cm for use in measuring the heat transfer and pressure drop in thin (6 mm or less), compact heat exchangers. Helium gas at flow rates of 0 to 40 kg/h and pressures to 6.9 MPa (1000 psi) is the working fluid. The instrumentation used in the apparatus and the methods for analyzing the data is described. The apparatus will be used initially to test the performance of prototype cooling jackets for the engine struts of the National Aerospace Plane (NASP).

Olson, Douglas A.↗

Heat Transfer to Fuel Sprays Injected into Heated Gases

This report presents the results of a study made of the influence of several variables on the pressure decrease accompanying injection of a relatively cool liquid into a heated compressed gas. Indirectly, this pressure decrease and the time rate of change of it are indicative of the total heat transferred as well as the rate of heat transfer between the gas and the injected liquid. Air, nitrogen, and carbon dioxide were used as ambient gases; diesel fuel and benzene were the injected liquids. The gas densities and gas-fuel ratios covered approximately the range used in compression-ignition engines. The gas temperatures ranged from 150 degrees c. to 350 degrees c.

Selden, Robert F↗

High heat flux loop heat pipes

Loop heat pipes (LHPs) can transport very large thermal power loads over long distances, through flexible, small diameter tubes against gravitational heads. In order to overcome the evaporator limit of LHPs, which is of about 0.07 MW/sq m, work was carried out to improve the efficiency by threefold to tenfold. The vapor passage geometry for the high heat flux conditions is shown. A bidisperse wick material within the circumferential vapor passages was used. Along with heat flux enhancement, several underlying issues were demonstrated, including the fabrication of bidisperse powder with controlled properties and the fabrication of a device geometry capable of replacing vapor passages with bidisperse powder.

North, Mark T.↗

Heat-Transfer and Pressure Measurements from a Flight Test of the Third 1/18-Scale Model of the Titan Intercontinental Ballistic Missile up to a Mach Number of 3.86 and Reynolds Number per Foot of 23.5 x 10(exp 6) and a Comparison with Heat Transfer

Heat-transfer and pressure measurements were obtained from a flight test of a 1/18-scale model of the Titan intercontinental ballistic missile up to a Mach number of 3.86 and Reynolds number per foot of 23.5 x 10(exp 6) and are compared with the data of two previously tested 1/18-scale models. Boundary-layer transition was observed on the nose of the model. Van Driest's theory predicted heat-transfer coefficients reasonably well for the fully laminar flow but predictions made by Van Driest's theory for turbulent flow were considerably higher than the measurements when the skin was being heated. Comparison with the flight test of two similar models shows fair repeatability of the measurements for fully laminar or turbulent flow.

Graham, John B., Jr.↗

A New Determination of Io's Heat Flow Using Diurnal Heat Balance Constraints

We use heat balance arguments to obtain a new estimate of Io's heat flow that does not depend on assumptions about the temperatures of its thermal anomalies. Our estimated heat flow is somewhat less than 2.2 +/- 0.9 W/sq m. Additional information is contained in the original extended abstract.

Spencer, J. R.↗

Heat Transfer in the Turbulent Incompressible Boundary Layer: Effect of Location of Transition and Prediction of Heat Transfer in a Known Transition Region - IV

The effect of the location of transition on the heat transfer to the turbulent incompressible boundary layer is analyzed. The analysis indicates that considerably higher heat-transfer rates may occur for some distance downstream if the transition is very late. The results of a limited experimental investigation are in substantial agreement with the results of the analysis. If the extent of the transition region is known, the analysis also allows adequate prediction of heat-transfer coefficients within the transition region. The nature of this analysis is such that it should predict local shear coefficients in the transition region equally well.

Reynolds, W. C.↗

High Temperature Heat Rejection System for Large Heat Loads; Architecture and Trade Study Results

To investigate space nuclear reactor technologies, NASA has awarded several contracts under Project Prometheus, the Nuclear Systems Program. The effort described in this paper was performed under one of those contracts (the Brayton NRA) . Like all power conversion systems, nuclear power conversion systems operate at efficiencies less than 100% resulting in the need to reject waste heat to space. Several different HRSs (Heat Rejection Systems) potential designs have been identified for rejecting NEP (Nuclear Electric Power) waste heat and several of them for a CBC (Closed Brayton Cycle) power conversion system are described herein and the results of their initial analyses presented. The analyses presented were performed as part of an initial trade study to recommend a promising HRS for advancement of its TRL.

Nilitkin, Michael N.↗

Heat Transfer from High-Temperature Surfaces to Fluids III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperatures up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R.

Sams, Eldon W.↗

Using a Cold Radiometer to Measure Heat Loads and Survey Heat Leaks

We have developed an inexpensive cold radiometer for use in thermal/vacuum chambers to measure heat loads, characterize emissivity and specularity of surfaces and to survey areas to evaluate stray heat loads. We report here the results of two such tests for the James Webb Space Telescope to measure heat loads and effective emissivities of 2 major pieces of optical ground support equipment that will be used in upcoming thermal vacuum testing of the Telescope.

Radiometer↗

Using a Cold Radiometer to Measure Heat Loads and Survey Heat Leaks

We have developed an inexpensive cold radiometer for use in thermal/vacuum chambers to measure heat loads, characterize emissivity and specularity of surfaces and to survey areas to evaluate stray heat loads. We report here the results of two such tests for the James Webb Space Telescope to measure heat loads and effective emissivities of2 major pieces of optical ground support equipment that will be used in upcoming thermal vacuum testing of the Telescope.

DiPirro, M.↗

Hyper-cooling Limit, Heat of Fusion, and Temperature-Dependent Specific Heat of Fe-Cr-Ni Melts

Thermophysical properties of Fe-Cr-Ni melts are studied using electrostatic levitation and rapid solidification techniques. Six hypoeutectic Fe(sub 0.72)Cr(sub w)Ni(sub(0.28−w)) alloys with a Cr/Ni ratio of around 0.8 were melted and solidified at different degrees of undercooling. From the observed relationship between the undercooling and thermal plateau time, the hyper-cooling limit and heat of fusion of Fe(sub 0.72)Cr(sub w)Ni(sub(0.28−w)) melts are determined as a function of Cr mass fraction. A ratio of specific heat and total hemispherical emissivity of the Fe-Cr-Ni melts is calculated using the time-temperature profiles. A new method is presented to evaluate the temperature dependence of specific heat for undercooled melts and applied to this alloy family.

Sangho Jeon↗

Molten salt as a heat transfer fluid for heating a subsurface formation

A heating system for a subsurface formation includes a conduit located in an opening in the subsurface formation. An insulated conductor is located in the conduit. A material is in the conduit between a portion of the insulated conductor and a portion of the conduit. The material may be a salt. The material is a fluid at operating temperature of the heating system. Heat transfers from the insulated conductor to the fluid, from the fluid to the conduit, and from the conduit to the subsurface formation.

Nguyen, Scott Vinh↗

HEAT INPUT AND POST WELD HEAT TREATMENT EFFECTS ON REDUCED-ACTIVATION FERRITIC/MARTENSITIC STEEL FRICTION STIR WELDS

Reduced-activation ferritic/martensitic (RAFM) steels are an important class of structural materials for fusion reactor internals developed in recent years because of their improved irradiation resistance. However, they can suffer from welding induced property degradations. In this paper, a solid phase joining technology friction stir welding (FSW) was adopted to join a RAFM steel Eurofer 97 and different FSW parameters/heat input were chosen to produce welds. FSW response parameters, joint microstructures and microhardness were investigated to reveal relationships among welding heat input, weld structure characterization and mechanical properties. In general, FSW heat input results in high hardness inside the stir zone mostly due to a martensitic transformation. It is possible to produce friction stir welds similar to but not with exactly the same base metal hardness when using low power input because of other hardening mechanisms. Further, post weld heat treatment (PWHT) is a very effective way to reduce FSW stir zone hardness values.

Tang, Wei↗

Thermoelectric Heat Pump Clothes Dryer using Secondary Loop Heat Exchangers: Experimental Evaluation

Past work has shown that thermoelectric clothes dryers are capable of much higher efficiency than electric resistance clothes dryers. In an effort to improve performance and reduce material utilization, this work explores a new secondary loop system configuration. In this configuration, heat is transferred between air and the thermoelectric heat pumps via two water loops and two water-to-air fin-tube type heat exchangers. In this work, performance is investigated and analyzed using experimental data.

Patel, Viral K.↗

An Analysis on Cost Reduction Potential of Vertical Bore Ground Heat Exchangers Used for Ground Source Heat Pump Systems

The cost for installing ground heat exchangers (GHXs) used for ground source heat pump (GSHP) systems usually accounts for more than 30% of the total cost of a GSHP system and it is the biggest contributor to the cost premium of GSHPs compared with conventional HVAC systems. This study evaluates the cost reduction potential of several possible improvements in borehole heat transfer and bore field layout. A detailed cost model for GHX installation was updated and new features were added to account for various GHX designs, geological conditions, and drilling technologies. Coupled with a well-established GHX sizing program, a systematic study was conducted to assess the impacts of these improvements on the needed total drilling length and resulting cost under various geological and loading conditions. Finally, improvements with significant potential to reduce GHX installation cost are recommended.

Liu, Xiaobing↗

Hydrocarbons as natural refrigerants for heat pump water heating applications

Growing awareness of the potential environmental impacts of conventional refrigerants (CFCs and HFCs) has led to efforts to identify suitable refrigerants for various heat pump applications with minimum environmental impact. This study is focused on the performance evaluation of pure propane and isobutane as drop-in-replacement for R134a for heat pump water heating (HPWH). A component-based model is used to predict the performance. Key performance parameters such as unified energy factor, first hour rating and thermal stratification in the water tank are investigated. Appropriate experiments are conducted to validate the finding from model. Simulation and experimental findings suggest that both alternative refrigerants could provide comparable system performance to that of the baseline system containing R134a. System refrigerant charge and the condenser discharge temperature are established to investigate the potential of hydrocarbon refrigerants to substitute R134a without significant system modifications.

Nawaz, Kashif↗

Heat sink for luminaire and luminaire arrangements having a heat sink

A heat sink for a luminaire includes a central portion having a top surface and a bottom surface. The bottom surface is adapted to receive a lighting arrangement. The heat sink further includes a plurality of arms configured to dissipate heat generated by the lighting arrangement. The plurality of arms extend radially outward from the central portion. Each one of the plurality of arms is substantially arcuate between a proximal end and a distal end.

Trublowski, John↗