Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Connected”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Generic Multi-Frequency Modelling of Converter-Connected Renewable Energy Generators Considering Frequency and Sequence Couplings

Frequency and sequence couplings can compromise the trustworthiness of multi-frequency models for converter-based systems. There have been effective attempts to address the couplings mainly by linearized averaged models. Only a few studies have been conducted on practical optimization of such models with enormous matrices and experimental results. This paper provides a generic theory for coupling patterns and proposes a multi-frequency modelling method to detect and address only the main couplings in the sequence domain for converter-connected renewable energy generators. The proposed generic model is based on empirical tests using small-signal perturbations and adopting Fourier transform on the switching converter response. The proposed theory and modelling methodology are verified using a 7MVA grid emulator for voltage perturbation tests on a 2MVA photo-voltaic converter. Accordingly, the couplings can exist in more generic forms, including multiples of perturbation and fundamental frequencies. To the best of our knowledge, the patterns with the multiples of the perturbation frequency have been overlooked in the literature. Furthermore, the mirror frequency concept is valid for all coupling patterns and is included in the proposed model. Besides, the proposed patterns and the environment noise levels have been practical criteria for selecting the main couplings.

frequency and sequence couplings↗

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

14 SOLAR ENERGY↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Grid-Forming Medium-Voltage Power Electronics Hub in a Microgrid Setting: Preprint

This paper presents the application of a new design of a multiport, modular, medium-voltage power electronics hub (M3PE-HUB) in a microgrid setting. The M3PE-HUB system was modeled in a digital real-time simulator (DRTS) and integrated into the Banshee microgrid test system. This paper presents the preliminary DRTS simulation-based results of the M3PE- HUB system connected in a test microgrid system. Verification and validation of the M3PE-HUB architecture and controls in the test microgrid setting are the primary contributions of this work. The results of the operation during the islanding and resynchronization process indicate the feasibility of the proposed architecture in a microgrid setting. This paper also presents results for a system reconfiguration use case where the M3PE- HUB was used to reconfigure the system under a fault condition.

grid forming↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multilevel well modeling in aggregation-based nonlinear multigrid for multiphase flow in porous media

A full approximation scheme (FAS) nonlinear multigrid solver for two-phase flow and transport problems driven by wells with multiple perforations is developed here. It is an extension to our previous work on FAS solvers for diffusion and transport problems. The solver is applicable to discrete problems defined on unstructured grids as the coarsening algorithm is aggregation-based and algebraic. To construct coarse basis that can better capture the radial flow near wells, coarse grids in which perforated well cells are not near the coarse-element interface are desired. This is achieved by an aggregation algorithm proposed in this paper that makes use of the location of well cells in the cell-connectivity graph. Numerical examples in which the FAS solver is compared against Newton's method on benchmark problems are given. In particular, for a refined version of the SAIGUP model, the FAS solver is at least 35% faster than Newton's method for time steps with a CFL number greater than 10.

58 GEOSCIENCES↗

Use of Grid-Forming Medium-Voltage Power Electronics Hub in a Microgrid Setting

This paper presents the application of a new design of a multiport, modular, medium-voltage power electronics hub (M3PE-HUB) in a microgrid setting. The M3PE-HUB system was modeled in a digital real-time simulator (DRTS) and integrated into the Banshee microgrid test system. This paper presents the preliminary DRTS simulation-based results of the M3PE-HUB system connected in a test microgrid system. Verification and validation of the M3PE-HUB architecture and controls in the test microgrid setting are the primary contributions of this work. The results of the operation during the islanding and resynchronization process indicate the feasibility of the proposed architecture in a microgrid setting. This paper also presents results for a system reconfiguration use case where the M3PE-HUB was used to reconfigure the system under a fault condition.

grid forming↗

Connected Communities: A Multi-Building Energy Management Approach

Connected Communities (CCs) are collections of buildings and distributed energy resources (DERs) that incorporate integrated energy management strategies at the multi-building scale. Based on the research conducted for this report, RMI and NREL have identified examples of CCs that are enabling increasingly integrated solutions, sharing resources among buildings, and providing services back to the grid. As demonstrated by these examples, CCs can provide real and scalable solutions to mitigate energy costs, enable more flexibility in grid operations, and offer choices in meeting greenhouse gas (GHG) emissions goals. Nationwide examples of these solutions are included in the appendix of this report. In order to understand the most promising practices for the design, operation, and business models associated with CCs, a search was performed to create a nationwide inventory of CCs and multiple stakeholder interviews were conducted. Based on that research, this paper explores the many factors that influence the development and operation of CCs and evaluates their potential value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blackstart of Power Grids with Inverter-Based Resources

This paper presents the findings of our investigation into inverter-based resource-(IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

A two-stage service restoration method for electric power distribution systems

Improving the reliability of power distribution systems is critically important for both utilities and customers. This calls for an efficient service restoration module within a distribution management system to support the implementation of self-healing smart grid networks. Although the emerging smart grid technologies, including distributed generators (DGs) and remote-controlled switches, enhance the self-healing capability and allow faster recovery, they still pose additional complexity to the service restoration problem, especially under cold load pickup (CLPU) conditions. Herein, a novel two-stage restoration framework is proposed to generate a restoration solutions with a sequence of control actions. The first stage generates a restoration plan that supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islanding methods. The second stage generates an optimal sequence of switching operations to bring the outaged system quickly to the final restored configuration. The problem is formulated as a mixed-integer linear program that incorporates system connectivity, operating constraints, and the CLPU models. It is demonstrated that on using a multi-feeder test case, the proposed framework is effective in utilizing all available resources to quickly restore the service and generate an optimal sequence of switching actions to be used by the operator to reach the desired optimal configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Movement of Cracked Silicon Solar Cells During Module Temperature Changes

Cracks in crystalline silicon solar cells can lead to substantial power loss. While the cells' metal contacts can initially bridge these cracks and maintain electrical connections, the bridges are damaged by mechanical loads, including those due to temperature changes. We investigated the metallization bridges that form over cracks in encapsulated silicon solar cells. Microscopic characterization showed that the crack in the silicon can immediately propagate through the metal grid, but the grid can maintain electrical contact once the load is removed. We also quantified the movement of the cell fragments separated by a crack as a function of temperature. Cell fragments are free to move diagonally and to rotate, so the change in gap across the crack during a temperature change varies along the length of the crack. In one sample, we showed that a 10 degrees C temperature change, causing a 2 um increase in the separation of cell fragments, was sufficient to cause a reversible electrical disconnection of metallization bridging a crack.

14 SOLAR ENERGY↗

An Effective Current Balancing Method for Inverters With Paralleled Silicon Carbide Power Modules

Silicon carbide (SiC) MOSFET has many superior characteristics in high power applications. Paralleling the SiC devices is an effective approach to increase the current capacity of the system, which also leads to current sharing issues. In this article, both transient and steady-state current sharing issues are studied for the high-power grid-tied inverters with paralleled SiC modules with an effective current balancing strategy proposed to address both issues simultaneously. The steady-state imbalance current due to the parameter mismatch is suppressed by the self-inductance of power cables used for paralleling connection. With the elimination of steady-state imbalance current, the transient imbalance current sensing is much simplified and can be realized by using low-cost current sensors. With the sensed imbalance current, a closed-loop control approach is proposed to adjust the modulation reference signal for each module to mitigate the remaining transient imbalance current. Furthermore, the proposed method is straightforward to implement with enhanced compatibility and flexibility compared to existing methods. Experimental studies are performed using inverters with 2 and 4 power modules paralleled in each phase to demonstrate the effectiveness of the proposed method.

42 ENGINEERING↗

Distributed-Memory Parallel JointNMF

Joint Nonnegative Matrix Factorization (JointNMF) is a hybrid method for mining information from datasets that contain both feature and connection information. We propose distributed-memory parallelizations of three algorithms for solving the JointNMF problem based on Alternating Nonnegative Least Squares, Projected Gradient Descent, and Projected Gauss-Newton. We extend well-known communication-avoiding algorithms using a single processor grid case to our coupled case on two processor grids. We demonstrate the scalability of the algorithms on up to 960 cores (40 nodes) with 60% parallel efficiency. The more sophisticated Alternating Nonnegative Least Squares (ANLS) and Gauss-Newton variants outperform the first-order gradient descent method in reducing the objective on large-scale problems. We perform a topic modelling task on a large corpus of academic papers that consists of over 37 million paper abstracts and nearly a billion citation relationships, demonstrating the utility and scalability of the methods.

Eswar, Srinivas↗

Optimal resource allocation for flexible-grid entanglement distribution networks

We use a genetic algorithm (GA) as a design aid for determining the optimal provisioning of entangled photon spectrum in flex-grid quantum networks with arbitrary numbers of channels and users. After introducing a general model for entanglement distribution based on frequency-polarization hyperentangled biphotons, we derive upper bounds on fidelity and entangled bit rate for networks comprising one-to-one user connections. Simple conditions based on user detector quality and link efficiencies are found that determine whether entanglement is possible. We successfully apply a GA to find optimal resource allocations in four different representative network scenarios and validate features of our model experimentally in a quantum local area network in deployed fiber. Our results show promise for the rapid design of large-scale entanglement distribution networks.

97 MATHEMATICS AND COMPUTING↗