Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Interoperability of GADU in using heterogeneous Grid resources for bioinformatics applications.

Bioinformatics tools used for efficient and computationally intensive analysis of genetic sequences require large-scale computational resources to accommodate the growing data. Grid computational resources such as the Open Science Grid and TeraGrid have proved useful for scientific discovery. The genome analysis and database update system (GADU) is a high-throughput computational system developed to automate the steps involved in accessing the Grid resources for running bioinformatics applications. This paper describes the requirements for building an automated scalable system such as GADU that can run jobs on different Grids. The paper describes the resource-independent configuration of GADU using the Pegasus-based virtual data system that makes high-throughput computational tools interoperable on heterogeneous Grid resources. The paper also highlights the features implemented to make GADU a gateway to computationally intensive bioinformatics applications on the Grid. The paper will not go into the details of problems involved or the lessons learned in using individual Grid resources as it has already been published in our paper on genome analysis research environment (GNARE) and will focus primarily on the architecture that makes GADU resource independent and interoperable across heterogeneous Grid resources.

59 BASIC BIOLOGICAL SCIENCES↗

Value to the Grid From Managed Charging Based on California's High Renewables Study

Managed charging of electric vehicle (EV) loads has the potential to use renewable energy more effectively, shave peak demand, and fill demand valleys while serving transportation needs. However, the potential value to the grid from managed charging has not been fully quantified. This paper adopts the tools used in the National Renewable Energy Laboratory's California Low Carbon Grid Study to quantify value to the grid from managed charging by using three levels of managed loads for 13 terawatt-hours of annual load from three million EVs in a 2030 California grid scenario. Simulation results show that management of the EV fleet's aggregate load from unmanaged to 100% managed results in savings between 210 million and 660 million annually in generation system costs, depending on grid conditions. The simulation results also suggest that targeted EV supply equipment (EVSE) deployments at workplaces and other mid-day parking locations will be needed to support managed charging in a high-renewables California and enable the identified value to the grid. Although the value of generation to the grid from managed EV load paired with high renewables seems substantial, we estimate that the installed cost of an EVSE must be between 1,000 and 3,000 for a 10-year life to be cost neutral, depending on grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guest Editorial High Performance Computing (HPC) Applications for a More Resilient and Efficient Power Grid

The power grid has been evolving over the last 120 years, but it is seeing more changes in this decade and next than it has seen over the past century. In particular, the widespread deployment of intermittent renewable generation, smart loads and devices, hierarchical and distributed control technologies, phasor measurement units, energy storage, and widespread usage of electric vehicles will require fundamental changes in methods and tools for the operation and planning of the power grid. The resulting new dynamic and stochastic behaviors will demand the inclusion of more complexity in modeling the power grid. Solving such complex models in the traditional computing environment will be a major challenge. Along with the increasing complexity of power system models, the increasing complexity of smart grid data further adds to the prevailing challenges. In this environment, the myriad of smart sensors and meters in the power grid increase by multiple orders of magnitude, so do the volume and speed of the data. The information infrastructure will need to drastically change to support the exchange of enormous amounts of data as smart grid applications will need the capability to collect, assimilate, analyze and process the data, to meet real-time grid functions. High performance computing (HPC) holds the promise to enhance these functions, but it is a great resource that has not been fully explored and adopted for the power grid domain.

Huang, Zhenyu Henry↗

Wide-area situation awareness in electric power grid

Two primary elements of the US energy policy are demand management and efficiency and renewable sources. Major objectives are clean energy transmission and integration, reliable energy transmission, and grid cyber security. Development of the Smart Grid seeks to achieve these goals by lowering energy costs for consumers, achieving energy independence and reducing greenhouse gas emissions. The Smart Grid is expected to enable real time wide-area situation awareness (SA) for operators. Requirements for wide-area SA have been identified among interoperability standards proposed by the Federal Energy Regulatory Commission and the National Institute of Standards and Technology to ensure smart-grid functionality. Wide-area SA and enhanced decision support and visualization tools are key elements in the transformation to the Smart Grid. This paper discusses human factors research to promote SA in the electric power grid and the Smart Grid. Topics that will be discussed include the role of human factors in meeting US energy policy goals, the impact and challenges for Smart Grid development, and cyber security challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Precision grid and hand motion for accurate needle insertion in brachytherapy

Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quoted as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.

60 APPLIED LIFE SCIENCES↗

test-grid-buildouts [SWR-23-112]

Test-grid-buildouts is a set of notebooks for creating buildouts of synthetic transmission grids with various levels of renewable energy. Workflows can be used to augment various test grid with varying levels of wind/solar generation. Aggregated renewable energy time series (actuals and scenarios) at grid buses can then be used for various transmission grid operation problems. Highly customizable workflow consists of parsing of synthetic grid files, setting up SAM & reV simulations, application of exclusion masks, creating of custom renewable generators on the grid, aggregating of power time series, and writing of modified grid description files.

Satkauskas, Ignas↗

Mastering Uncertainty and Risk at Multiple Time Scales in the Future Electrical Grid

Today's electrical grids enjoy a relatively clean separation of spatio-temporal scales yielding a compartmentalization of grid design, optimization, control and risk assessment allowing for the use of conventional mathematical tools within each area. In contrast, the future grid will incorporate time-intermittent renewable generation, operate via faster electrical markets, and tap the latent control capability at finer grid modeling scales; creating a fundamentally new set of couplings across spatiotemporal scales and requiring revolutionary advances in mathematics techniques to bridge these scales. One example is found in decade-scale grid expansion planning in which today's algorithms assume accurate load forecasts and well-controlled generation. Incorporating intermittent renewable generation creates fluctuating network flows at the hourly time scale, inherently linking the ability of a transmission line to deliver electrical power to hourly operational decisions. New operations-based planning algorithms are required, creating new mathematical challenges. Spatio-temporal scales are also crossed when the future grid's minute-scale fluctuations in network flows (due to intermittent generation) create a disordered state upon which second-scale transient grid dynamics propagate effectively invalidating today's on-line dynamic stability analyses. Addressing this challenge requires new on-line algorithms that use large data streams from new grid sensing technologies to physically aggregate across many spatial scales to create responsive, data-driven dynamic models. Here, we sketch the mathematical foundations of these problems and potential solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Grid Demonstration Project (Final Report)

The National Rural Electric Cooperative Association (NRECA) organized the NRECA-U.S. Department of Energy (DOE) Smart Grid Demonstration Project (DE-OE0000222) to install and study a broad range of advanced smart grid technologies in a demonstration that spanned 23 electric cooperatives in 12 states. More than 205,444 pieces of electronic equipment and more than 100,000 minor items (bracket, labels, mounting hardware, fiber optic cable, etc.) were installed to upgrade and enhance the efficiency, reliability, and resiliency of the power networks at the participating co-ops. The objective of this project was to build a path for other electric utilities, and particularly electrical cooperatives, to adopt emerging smart grid technology when it can improve utility operations, thus advancing the co-ops’ familiarity and comfort with such technology. Specifically, the project executed multiple subprojects employing a range of emerging smart grid technologies to test their cost-effectiveness and, where the technology demonstrated value, provided case studies that will enable other electric utilities—particularly electric cooperatives— to use these technologies. NRECA structured the project according to the following three areas: Demonstration of smart grid technology; Advancement of standards to enable the interoperability of components; and Improvement of grid cyber security. We termed these three areas Technology Deployment Study, Interoperability, and Cyber Security. Although the deployment of technology and studying the demonstration projects at coops accounted for the largest portion of the project budget by far, we see our accomplishments in each of the areas as critical to advancing the smart grid. All project deliverables have been published. Technology Deployment Study: The deliverable was a set of 11 single-topic technical reports in areas related to the listed technologies. Each of these reports has already been submitted to DOE, distributed to co-ops, and posted for universal access at www.nreca.coop/smartgrid. This research is available for widespread distribution to both cooperative members and non-members. These reports are listed in Table 1.2. Interoperability: The deliverable in this area was the advancement of the MultiSpeak™ interoperability standard from version 4.0 to version 5.0, and improvement in the MultiSpeak™ documentation to include more than 100 use cases. This deliverable substantially expanded the scope and usability of MultiSpeak™, the most widely deployed utility interoperability standard, now in use by more than 900 utilities. MultiSpeak™ documentation can be accessed only at www.multispeak.org. Cyber Security: NRECA’s starting point was to develop cyber security tools that incorporated succinct guidance on best practices. The deliverables were: cyber security extensions to MultiSpeak™, which allow more security message exchanges; a Guide to Developing a Cyber Security and Risk Mitigation Plan; a Cyber Security Risk Mitigation Checklist; a Cyber Security Plan Template that co-ops can use to create their own cyber security plans; and Security Questions for Smart Grid Vendors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Functional Forms of Grid Disturbances

This report introduces a functional form that may be used to quantitatively predict the impacts of new grid tools and changing system qualities on the likelihoods, durations, and depths of various grid disturbances. Each disturbance scenario is modeled to have three component stages—avoidance, reactance and recovery, which together parametrically estimate one disturbance’s impacts. The modeled scenario is then placed and replicated within an analysis period to represent the likelihood or frequency of the scenario and its consequent impacts. Whereas analysts have struggled to define and apply metrics for grid resilience, the functional form introduced by this report shares units of measurement with accepted grid-status measures (e.g., numbers of customers currently experiencing a service outage). Furthermore, the integrated and averaged functional form over an analysis period provides a meaningful normalized performance metric (e.g., customer outage minutes per year) that is ultimately independent of the duration of the period of. The approach may be applied similarly regardless of the severity or frequency of the disturbances that are being analyzed. Because metrics can be chosen to be identical in both the hypothetical future and the actual historical past, the historical past eventually becomes the test of the future predictions, at least in a statistical sense. The authors originally developed this approach to facilitate analysis of the effects of transactive energy (TE) systems effects on electric power grid resilience. TE systems invite energy suppliers and consumers to actively collaborate toward the discovery of, and their responses to, the locational value of energy. The findings from this process are often embodied as energy prices, the dynamics of which indicate the locational value of energy and can further represent important grid service needs. While some academic papers claim to quantify the value of a specific TE system design toward grid resilience, the answer, in general, has been elusive. Not only do multiple and conflicting definitions of resilience and reliability exist, but countless TE systems are being invented. We conclude the following: (1) The ideal analysis should harmonize rather than differentiate resilience and reliability. Therefore, this report uses the more general term disturbance whenever the overloaded terms resilience and reliability can be avoided. (2) The effectiveness of TE systems must be mapped to underlying qualities of a TE system, thereby avoiding presumptions that every TE design offers similar advantages. The authors seek to evaluate the parametric effects of TE system qualities (e.g., spatial granularity, granularity of time steps, length of future prediction horizon) on avoiding, reacting to, and recovering from grid disturbances. Furthermore, any advantages (or disadvantages) must be fairly compared with the many alternative tools, systems, and strategies that might offer comparable benefits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product Report

Objective analysis (OA) is a method of mapping unstructured data to a structured grid. In the context of scanning radar data, OA is used to interpolate data in antenna coordinates (range, azimuth, and elevation) onto a regularly spaced Cartesian grid (Trapp and Doswell 2000). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product (VAP) uses the Python ARM Radar Toolkit (Py-ART), a data model-driven interactive architecture for working with weather radar data, to map the data to a Cartesian grid (Helmus and Collis 2016). MMCG, with Py-ART built in, has the ability to take radar data in antenna coordinates and map the gates to a Cartesian grid using inverse distance weight functions such as Cressman (square) and Barnes (exponential), but also can filter the data during the interpolation. MMCG also allows arbitrary formulations for the radius of influence, which are matched to particular radar scanning strategies. This creates a complex parameter space for optimizing the retention of storm structure detail while minimizing artifacts. MMCG takes data processed with ARM’s Corrected Precipitation Radar Moments in Antenna Coordinates (CMAC) VAP and maps it to a Cartesian grid as the output product. A variety of fields that have been mapped to the Cartesian grid are then saved to plots to complement each grid file.

54 ENVIRONMENTAL SCIENCES↗

TASTI-GRID: Overview of the State of Oregon’s Resilience and Reliability [Slides]

This report is intended to help your state identify the most effective investments to improve grid resilience and reliability, based on analysis of outage data, weather events, and the current state of the electric grid. The information presented is derived from the best available data. The discussions and recommendations included provide context and valuable insights into potential high returns on investment (ROI). Specifically, the report offers an overview of electric grid resilience in Oregon, covering outage information, reasons for outages, calculated "resilience scores" across the state, and recommendations for both immediate and long-term investments in grid infrastructure. The document provides a concise overview of the analytical capabilities of the TASTI-GRID team. By utilizing additional data and resources, it synthesizes insights from the platform to present a distinct perspective on investing in grid resilience throughout Oregon. This document is not intended to influence or direct state-level decisions related to investments in grid resilience and reliability. TASTI-GRID should not be used for real-time monitoring, supporting the ESF #12 emergency response functions, or predicting the restoration times for outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High performance auxiliary-propulsion ion thruster with ion-machined accelerator grid

An improvement in thruster performance was achieved by reducing the diameter of the accelerator grid holes. The smaller accelerator grid holes resulted in a reduction in neutral mercury atoms escaping the discharge chamber, which in turn enhanced the discharge propellant utilization from approximately 68 percent to 92 percent. The accelerator grids were fabricated by ion machining with an 8-centimeter-diameter thruster, and the screen grid holes individually focused ion beamlets onto the blank accelerator grid. The resulting accelerator grid holes are less than 1.12 millimeters in diameter, while previously used accelerator grids had hole diameters of 1.69 millimeters. The thruster could be operated with the small-hole accelerator grid at neutralizer potential.

Hudson, W. R.↗

Ion beam divergence characteristics of three-grid accelerator systems

A comprehensive experimental investigation of the geometrical and operating conditions which affect most strongly the ion beam divergence of three-grid accelerator systems is presented. Three-grid accelerator systems are shown to offer significant improvements in ion beam focusing over two-grid accelerator systems. These improvements are greatest for low, but limited, net-to-total accelerating voltage ratio ranges and small screen-to-accelerator grid separation ratios (i.e., high perveance grid sets). Ion beam focusing gains are negligible at a net-to-total accelerating voltage ratio near unity. Low decelerator grid impingement currents and low ion beam divergence angles require that the decelerator hole diameter be about twenty five percent larger than the accelerator hole diameter, also that the decelerator grid be spaced as close as is practically possible to the accelerator grid.

Aston, G.↗

An electrostatic analog for generating cascade grids

Accurate and efficient numerical simulation of flows through turbomachinery blade rows depends on the topology of the computational grids. These grids must reflect the periodic nature of turbomachinery blade row geometries and conform to the blade shapes. Three types of grids can be generated that meet these minimal requirements: through-flow grids, O-type grids, and C-type grids. A procedure which can be used to generate all three types of grids is presented. The resulting grids are orthogonal and can be stretched to capture the essential physics of the flow. A discussion is also presented detailing the extension of the generation procedure to three dimensional geometries.

Adamczyk, J. J.↗

Transonic airfoil calculations using solution-adaptive grids

A new algorithm for generating solution-adaptive grids (SAG) about airfoil configurations embedded in transonic flow is presented. The present SAG approach uses only the airfoil surface solution to recluster grid points on the airfoil surface, i.e., the reclustering problem is one dimension smaller than the flow-field calculation problem. Special controls automatically built into the elliptic grid generation procedure are then used to obtain grids with suitable interior behavior. This concept of redistributing grid points greatly simplifies the idea of solution-adaptive grids. Numerical results indicate significant improvements in accuracy for SAG grids relative to standard grids using the same number of points.

Holst, T. L.↗