Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

New technology for purging the steam generators of nuclear power plants

A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D{sub y} 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is several times that for the standard method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surface Treatment Strategies for Mitigating Gas Hydrate & Asphaltene Formation, Growth, and Deposition in Flowloops

Abstract Numerous solids including gas hydrates, waxes, and asphaltenes have the potential to form in the production lines of gas and oil fields. This creates a highly non-ideal scenario as the accumulation of said species leads to flow assurance issues, especially with long-term processes like deposition. Since an ever-increasing amount of material is deposited in place at the pipe surface, production stoppage or active mitigation efforts become inevitable. The latter production issues result in increased safety risks and operational expenditures. Therefore, a cost-effective, passive deposition mitigation technology, such as a pipeline coating or surface treatment is especially appealing. The ability to address multiple pipeline flow assurance issues simultaneously without actively disrupting production would represent a dramatic step forward in this area. This study is part of a long-term ongoing effort that evaluates the performance and application of an omniphobic surface treatment for solids deposition prevention in industrially relevant systems. In particular, this specific work concentrates on the efficacy and robustness of the treatment under fully flowing conditions. The apparatuses utilized for this include two flowloops: a lab-scale, high-pressure flowloop for gas hydrate and surface treatment durability studies, and a bench-scale, atmospheric pressure loop for crude oil and asphaltene experiments. Film growth in high-pressure flowloop tests corroborated previous reports of delayed gas hydrate nucleation observed in rocking cells. Without the aid of the memory effect, treated oil-dominated experiments never experienced hydrate formation, spending upwards of a week in the hydrate stability zone (at the subcooled/fluid test conditions). Subsequent tests which utilized the memory effect then revealed that the hydrate formation rate reduced in the presence of the surface treatment compared to a bare stainless-steel surface. This testing was part of a larger set of trials conducted in the flowloop, which lasted about one year. The surface treatment durability under flowing conditions was evaluated during this time. Even after experiencing ∼4000 operating hours and 2 full pressure cycles, no evidence of delamination or damage was detected. Finally, as part of an extension to previous work, corroded surface asphaltene deposition experiments were performed in a bench-top flowloop. Treated experiments displayed an order of magnitude reduction in both total oil (all fractions of crude oil) and asphaltene fraction deposited.

03 NATURAL GAS↗

Physics implications of the diphoton excess from the perspective of renormalization group flow

A very plausible explanation for the recently observed diphoton excess at the 13 TeV LHC is a (pseudo)scalar with mass around 750 GeV, which couples to a gluon pair and to a photon pair through loops involving vector-like quarks (VLQs). To accommodate the observed rate, the required Yukawa couplings tend to be large. A large Yukawa coupling would rapidly run up with the scale and quickly reach the perturbativity bound, indicating that new physics, possibly with a strong dynamics origin, is near by. The case becomes stronger especially if the ATLAS observation of a large width persists. In this paper we study the implication on the scale of new physics from the 750 GeV diphoton excess using the method of renormalization group running with careful treatment of different contributions and perturbativity criterion. Our results suggest that the scale of new physics is generically not much larger than the TeV scale, in particular if the width of the hinted (pseudo)scalar is large. Introducing multiple copies of VLQs, lowing the VLQ masses and enlarging VLQ electric charges help reduce the required Yukawa couplings and can push the cutoff scale to higher values. Nevertheless, if the width of the 750 GeV resonance turns out to be larger than about 1 GeV, it is very hard to increase the cutoff scale beyond a few TeVs. This is a strong hint that new particles in addition to the 750 GeV resonance and the vector-like quarks should be around the TeV scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report - FY2019

This report documents the operations and testing that was performed at the Mechanisms Engineering Test Loop (METL) during FY2019. The METL facility had a very successful initial year of operations having logged over 365 days of operations with molten sodium either flowing or static. FY2019 saw the commissioning, insertion, and extraction of the first test assembly in METL. In addition, METL is being prepared to support a second experiment, a thermal hydraulic experiment, called Thermal Hydraulic Experimental Test Article (THETA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Local Void Fractions on Subcooled Boiling Oscillations in Natural Circulation Boiling Loop

Passive heat removal using natural circulation boiling loops (NCBLs) is well established from the view point of the safety of boiling water reactors (BWRs). Nevertheless, NCBLs suffer from a large number of nonlinear flow oscillations due to low driving force for circulations. The local measurements of void fraction a are essential to clearly understand the mechanism of flow oscillations. In this work, we have measured the impedance from the needle probe using LCR meter and quantified time-averaged local a from the measured impedance under oscillating flow conditions in the NCBL. Impedance probes have been successfully used in estimating void fractions and bubble frequencies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improvement on the plasma performances via application of flowing lithium limiters in EAST tokamak

Three generation of flowing liquid lithium (FLiLi) limiters have been developed and successfully tested in EAST since 2014. It was confirmed that liquid Li could be driven by an innovative in-vessel DC electromagnetic J × B pump to form a recirculating loop. The FLiLi design was continuously upgraded, resulting in improvement of the liquid Li surface coverage (>80%), elimination of surface erosion, and the increase of heat exhaust capability. Promising results are obtained during FLiLi operations, including a reduction of impurities and recycling to improve plasma confinement, and a mitigation of ELM activity in H-mode plasmas. The FLiLi limiter program has shown basic compatibility with H-mode discharges with auxiliary heating power up to 8.3 MW. These efforts will expand to flowing liquid Li PFC in high heat flux zones, e.g. near the divertor strike point in reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systems and methods for expanding flow in a waste heat recovery system

A waste heat recovery system includes a first heat exchanger, a second heat exchanger, and an expander. The first heat exchanger receives working fluid from a first portion of a first loop and provides the working fluid to a second portion of the first loop. The second heat exchanger receives the working fluid from a first portion of a second loop and provides the working fluid to a second portion of the second loop. The expander provides the working fluid to a first portion of a common line. The expander includes a stator. The stator includes a first inlet and a second inlet. The common line provides the working fluid to both the first loop and the second loop upstream of the first portion of the first loop and upstream of the first portion of the second loop.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Selection and characterization of ssDNA aptamers specifically recognizing pathogenic Vibrio alginolyticus

Abstract Vibrio alginolyticus ( V. alginolyticus ) is a major opportunistic pathogen to both marine animals and humans, which has also caused heavy economic losses to mariculture. The aim of this study was to develop highly specific aptamers for V. alginolyticus . Single‐stranded DNA (ssDNA) aptamers with high binding affinity to viable V. alginolyticus were generated by Systematic Evolution of Ligands by Exponential Enrichment (SELEX) and identified by flow cytometric analysis in this study. The selected aptamers showed high specificity for V. alginolyticus and low apparent binding for other bacteria. The aptamers formed distinct stem‐loop structures, which could form the basis of aptamers’ specific binding to the target V. alginolyticus . Aptamer VA2 and VA8 showed particularly high binding affinity constant (K d ) of 14.31 ± 4.26 and 90.00 ± 13.51 nM, respectively. The aptamers produced no cytotoxic effects in vitro and in vivo. ssDNA aptamers were successfully selected against the viable bacteria pathogen V. alginolyticus by SELEX. The aptamers selected in this study could be not only applied as specific chemical molecular probes for studying V. alginolyticus pathogenesis to Trachinotus ovatus , but also developing rapid convenient diagnosis assay for V. alginolyticus infection, even when applied to the complex sample matrix, such as food and environment samples.

Yu, Qing↗

High Temperature Fluoride Salt Test Loop

Effective high-temperature thermal energy exchange and delivery at temperatures over 600°C has the potential of significant impact by reducing both the capital and operating cost of energy conversion and transport systems. It is one of the key technologies necessary for efficient hydrogen production and could potentially enhance efficiencies of high-temperature solar systems. Today, there are no standard commercially available high-performance heat transfer fluids above 600°C. High pressures associated with water and gaseous coolants (such as helium) at elevated temperatures impose limiting design conditions for the materials in most energy systems. Liquid salts offer high-temperature capabilities at low vapor pressures, good heat transport properties, and reasonable costs and are therefore leading candidate fluids for next-generation energy production. Liquid-fluoride-salt-cooled, graphite-moderated reactors, referred to as Fluoride Salt Reactors (FHRs), are specifically designed to exploit the excellent heat transfer properties of liquid fluoride salts while maximizing their thermal efficiency and minimizing cost. The FHR s outstanding heat transfer properties, combined with its fully passive safety, make this reactor the most technologically desirable nuclear power reactor class for next-generation energy production. Multiple FHR designs are presently being considered. These range from the Pebble Bed Advanced High Temperature Reactor (PB-AHTR) [1] design originally developed by UC-Berkeley to the Small Advanced High-Temperature Reactor (SmAHTR) and the large scale FHR both being developed at ORNL [2]. The value of high-temperature, molten-salt-cooled reactors is also recognized internationally, and Czechoslovakia, France, India, and China all have salt-cooled reactor development under way. The liquid salt experiment presently being developed uses the PB-AHTR as its focus. One core design of the PB-AHTR features multiple 20 cm diameter, 3.2 m long fuel channels with 3 cm diameter graphite-based fuel pebbles slowly circulating up through the core. Molten salt coolant (FLiBe) at 700°C flows concurrently (at significantly higher velocity) with the pebbles and is used to remove heat generated in the reactor core (approximately 1280 W/pebble), and supply it to a power conversion system. Refueling equipment continuously sorts spent fuel pebbles and replaces spent or damaged pebbles with fresh fuel. By combining greater or fewer numbers of pebble channel assemblies, multiple reactor designs with varying power levels can be offered. The PB-AHTR design is discussed in detail in Reference [1] and is shown schematically in Fig. 1. Fig. 1. PB-AHTR concept (drawing taken from Peterson et al., Design and Development of the Modular PB-AHTR Proceedings of ICApp 08). Pebble behavior within the core is a key issue in proving the viability of this concept. This includes understanding the behavior of the pebbles thermally, hydraulically, and mechanically (quantifying pebble wear characteristics, flow channel wear, etc). The experiment being developed is an initial step in characterizing the pebble behavior under realistic PB-AHTR operating conditions. It focuses on thermal and hydraulic behavior of a static pebble bed using a convective salt loop to provide prototypic fluid conditions to the bed, and a unique inductive heating technique to provide prototypic heating in the pebbles. The facility design is sufficiently versatile to allow a variety of other experimentation to be performed in the future. The facility can accommodate testing of scaled reactor components or sub-components such as flow diodes, salt-to-salt heat exchangers, and improved pump designs as well as testing of refueling equipment, high temperature instrumentation, and other reactor core designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Closed Loop Geothermal Working Group: GeoCLUSTER App, Subsurface Simulation Results, and Publications

To better understand the heat production, electricity generation performance, and economic viability of closed-loop geothermal systems in hot-dry rock, the Closed-Loop Geothermal Working Group -- a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed-loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and supercritical CO2) while varying seven continuous independent parameters of interest (mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying Python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the techno-economic analysis script are provided. This data submission will contain results from the Closed Loop Geothermal Working Group study that are within the public domain, including publications, simulation results, databases, and computer codes. GeoCLUSTER is a Python-based web application created using Dash, an open-source framework built on top of Flask that streamlines the building of data dashboards. GeoCLUSTER provides users with a collection of interactive methods for streamlining the exploration and visualization of an HDF5 dataset. The GeoCluster app and database are contained in the compressed file geocluster_vx.zip, where the "x" refers to the version number. For example, geocluster_v1.zip is Version 1 of the app. This zip file also contains installation instructions. **To use the GeoCLUSTER app in the cloud, click the link to "GeoCLUSTER on AWS" in the Resources section below. To use the GeoCLUSTER app locally, download the geocluster_vx.zip to your computer and uncompress this file. When uncompressed this file comprises two directories and the geocluster_installation.pdf file. The geo-data app contains the HDF5 database in condensed format, and the GeoCLUSTER directory contains the GeoCLUSTER app in the subdirectory dash_app, as app.py. The geocluster_installation.pdf file provides instructions on installing Python, the needed Python modules, and then executing the app.

15 GEOTHERMAL ENERGY↗

Uncertainty-Aware Machine Learning for Small-Angle X-ray Scattering Analysis in Autonomous Experimentation

Small-angle X-ray scattering (SAXS) is a powerful high-throughput characterization tool for probing nanoscale structure in native sample environments, providing real-time morphological information such as nanoparticle size and shape during synthesis. However, automated SAXS data analysis for extracting meaningful structural parameters is non-trivial and remains a bottleneck in closed-loop experimentation towards autonomous materials discovery, which demands fast, reliable, and uncertainty-aware data analysis. Here, we develop a machine-learning approach for automated SAXS analysis tailored to closed-loop nanoparticle synthesis. A Random Forest (RF) regression model is trained on 100,000 synthetic SAXS curves generated from polydisperse spherical nanoparticles with realistic background contributions. Using normalized one-dimensional SAXS intensity profiles as input, the RF model directly predicts nanoparticle radius, size polydispersity, and background parameters, while the ensemble standard deviation across trees provides built-in uncertainty quantification (UQ). On synthetic data, we show that combining fit-quality metrics (R 2 , MAE) with thresholds on prediction uncertainty reliably identifies accurate parameter estimates without access to ground truth. We then apply the trained model to 365 experimental SAXS profiles of citrate-reduced gold nanoparticles synthesized using an automated droplet-flow microreactor with in situ SAXS at a synchrotron beamline, classifying the results into high- and low-confidence subsets based on UQ metrics. Finally, we integrate RF-based SAXS analysis into a simulated closed-loop optimization campaign using Gaussian process Bayesian optimization to minimize nanoparticle polydispersity, benchmarking against conventional automated Levenberg–Marquardt fitting. The RF-guided campaign exhibits substantially faster convergence and lower relative opportunity cost (∼0.07 vs ∼0.3), demonstrating that uncertainty-aware machine-learning SAXS analysis significantly enhances the efficiency and robustness of autonomous nanomaterials synthesis workflows.

Bayesian optimization↗

Evaluating post-fire watershed response to varying burn severity and precipitation regimes using fully-distributed and integrated hydrologic models

Wildfires can cause significant changes in vegetation and soil, which may lead to increased surface runoff and soil erosion, thereby affecting water cycling within ecosystems. This study uses the Advanced Terrestrial Simulator (ATS), an integrated and fully distributed hydrologic model at the watershed scale, to examine post-fire hydrologic responses in selected watersheds with varying burn severities in the Pacific Northwest region of the United States. The model integrates surface overland flow, subsurface flow, and canopy biophysical processes. We have developed a new fire module in ATS to account for changes in soil hydraulic properties caused by fire in the topsoil layer. Modeling results indicate that, in the year following a high-severity burn, watershed-averaged evapotranspiration decreases by 25%. Additionally, post-fire peak flows increase by 18-29% in watersheds burned with medium to high severity due to changes in soil properties. Conversely, a low-severity burn results in less than a 1% increase in post-fire peak flow. Furthermore, a high-severity fire causes a 38% reduction in the infiltration rate within the affected watershed during the first post-fire wet season. Hypothetical numerical experiments with varying precipitation regimes after a high-severity fire show that post-fire peak flows can increase by 1-29% due to fire-induced changes in soil hydraulic properties. This study highlights the importance of using fully distributed hydrologic models to quantify disturbance-feedback loops, which are essential for understanding the complexities brought about by spatial heterogeneity in post-fire landscapes.

ATS↗

HUBBLE SPACE TELESCOPE OBSERVATIONS OF DUSTY FILAMENTS IN HERCULES A: EVIDENCE FOR ENTRAINMENT

We present U-, V-, and I-band images of the host galaxy of Hercules A (3C 348) obtained with HST/WFC3/UVIS. We find a network of dusty filaments which are more complex and extended than seen in earlier Hubble Space Telescope (HST) observations. The filaments are associated with a faint blue continuum light (possibly from young stars) and faint H{alpha} emission. It seems likely that the cold gas and dust has been stripped from a companion galaxy now seen as a secondary nucleus. There are dusty filaments aligned with the base of the jets on both eastern and western sides of the galaxy. The morphology of the filaments is different on the two sides-the western filaments are fairly straight, while the eastern filaments are mainly in two loop-like structures. We suggest that despite the difference in morphologies, both sets of filaments have been entrained in a slow-moving boundary layer outside the relativistic flow. As suggested by Fabian et al., magnetic fields in the filaments may stabilize them against disruption. We consider a speculative scenario to explain the relation between the radio source and the shock and cavities in the hot intracluster medium seen in the Chandra data. We suggest that the radio source originally ({approx}60 Myr ago) propagated along a position angle of {approx}35 Degree-Sign where it created the shock and cavities. The radio source axis changed to its current orientation ({approx}100 Degree-Sign ) possibly due to a supermassive black hole merger and began its current epoch of activity about 20 Myr ago.

79 ASTRONOMY AND ASTROPHYSICS↗