Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Pitfalls of Transparency: Lessons Learned from the Milford Flats Fire

The Community Environmental Monitoring Program (CEMP) consists of a network of 29 radiation and weather monitoring stations located over a 160,000-km2 area of southern Nevada, southwestern Utah, and southeastern California. The program provides stakeholders with a hands-on role in the monitoring for airborne radioactivity that could result from ongoing or past activities on the Nevada Test Site (NTS). The CEMP’s mission includes provisions for the transparency of the monitoring data as well as public accessibility to these data. This is accomplished through direct stakeholder participation, public outreach, and near real-time uploads of monitoring data to a publicly accessible web site located at http://cemp.dri.edu/. In early July 2007, a lightning strike ignited a wildfire just outside the city of Milford in southeastern Utah. This fire, named the Milford Flats Fire, grew rapidly and eventually became the largest wildfire in recorded history in the state, burning approximately 567 square miles. At about the same time, the pressurized ion chamber (PIC) located at the CEMP station in Milford began reporting average exposure rates that ranged from four to seven times normal for the area. Initially, it was believed that elevated readings could be a result of gamma-emitting radon progeny released by the fire and transported in smoke plumes. The U.S. Department of Energy issued a press release offering this as a possible first explanation, and the release received a great amount of attention, particularly in the state of Utah, where concerns were expressed that the fire could be causing re-suspension of radionuclides associated with fallout from past nuclear testing at the NTS. Subsequent analyses of particulate air filter samples obtained from the Milford station, as well as an examination of the data reported by the PIC, the timing of the incident, and diagnostic testing on the PIC, showed that the abnormal gamma readings were a result of instrument malfunction. WM2008 Conference, February 24-28, 2008, Phoenix, AZ This paper will review the data from the PIC and the analytical results of air filter samples collected at Milford, and present lessons learned from the Milford Flats Fire Incident on providing real-time access to monitoring data for the public.

54 ENVIRONMENTAL SCIENCES↗

Modeling the impact of smoke from prescribed fire on road visibility

Prescribed fires are planned to achieve conservation and fuel reduction objectives while minimizing smoke ground concentration to limit health impacts and road visibility impairment. Prescribed burns cannot indeed be conducted if those hazards are not within predefined limits. This paper proposes a new framework to evaluate road visibility that overcomes the limitation of the state of the art model, VSMOKE. The framework leverages the fast-running framework QUIC-Fire/QUIC-SMOKE to capture fire and smoke dynamics, and the timing and duration of hazardous conditions on the road network close to the burn unit (within 50–100 km). The paper presents parametric study using a real burn plot at Fort Stewart (GA, USA), under hypothetical wind conditions to understand the interplay between buoyancy and smoke dilution. Here, results showed that faster winds caused fire escape while slower winds did not achieve a complete burn. Furthermore, faster winds featured brief road visibility reduction below braking distance.

54 ENVIRONMENTAL SCIENCES↗

A Multi-Objective Advanced Design Methodology of Composite Beam-to-Column Joints Subjected to Seismic and Fire Loads

A multi-objective advanced design methodology dealing with seismic actions followed by fire on steel-concrete composite full strength joints with concrete filled tubes is proposed in this paper. The specimens were designed in detail in order to exhibit a suitable fire behaviour after a severe earthquake. The major aspects of the cyclic behaviour of composite joints are presented and commented upon. The data obtained from monotonic and cyclic experimental tests have been used to calibrate a model of the joint in order to perform seismic simulations on several moment resisting frames. A hysteretic law was used to take into account the seismic degradation of the joints. Finally, fire tests were conducted with the objective to evaluate fire resistance of the connection already damaged by an earthquake. The experimental activity together with FE simulation demonstrated the adequacy of the advanced design methodology.

58 GEOSCIENCES↗

Reduction of Fire Hazard in Materials for Irrigators and Water Collectors in Cooling Towers

A way of reducing the fire hazard of PVC film used to make cooling-tower irrigators and water collectors is examined. A new generation of fire retardant, nanostructured magnesium hydroxide, is used to impart fire retardant properties. The fabrication technology is optimized with a roller-calendering manufacturing technique, and the permissible ranges of fire hazard indicators for materials in irrigators and water collectors are determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dry cooling retrofits at existing fossil fuel-fired power plants in a water-stressed region: Tradeoffs in water savings, cost, and capacity shortfalls

This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling fuels and fire effects in 3D: Model description and applications

Scientists and managers critically need ways to assess how fuel treatments alter fire behavior, yet few tools currently exist for this purpose. In this work, we present a spatially-explicit-fuel-modeling system, FuelManager, which models fuels, vegetation growth, fire behavior (using a physics-based model, FIRETEC), and fire effects. FuelManager's flexible approach facilitates modeling fuels across a wide range of detail. Large trees or shrubs with specific coordinates are modeled as individual “Plants”, while understory plants are modeled as collections of plants called “LayerSets”. Both Plants and LayerSets contain various fuel particles (leaves, needles, twigs) with various properties including shape, size and surface area to volume ratio. A wide range of vegetation and treatments can be modeled, analyzed quantitatively and visualized in a 3D viewer. We describe the modeling approach and demonstrate fuel modeling at different levels of detail, fuel treatment and fire effects capabilities. Lastly, detailed model equations are provided in the Appendices.

54 ENVIRONMENTAL SCIENCES↗

QUIC-URB and QUIC-fire extension to complex terrain: Development of a terrain-following coordinate system

Ensemble-based approaches to prescribed fire planning cannot be supported by CFD-based models like FIRETEC and WFDS because they are too computationally expensive and cannot leverage LES approaches like CAWFE and WRF-SFIRE because too coarse of resolution. QUIC-Fire was developed to fill this gap but it cannot currently address complex terrain, typical for instance of the Western United States. In this paper, we describe the extension of the diagnostic wind model QUIC-URB, the wind engine of QUIC-Fire, to a terrain-following coordinate system. In particular, the paper presents the mathematical derivation of the wind solver leading to a linear system of equations that are solved through the successive over-relaxation method. The model is validated against a standard test used in previous works (the Askervein Hill) and against a new dataset from measurements in the Socorro Mountains, New Mexico. The terrain-following implementation captured the correct phenomenology for the isolated Askervein Hill, with a wind speed up at the top of the hill. We report the model agreed well with measurements on the upwind side of the peak, but overestimated speed-up on the downwind side of the hill. This is due to the inability of the model to generate flow separation and wake-eddy dynamics. On a common laptop, the divergence-free wind field was obtained in 6 s, making the solver appealing for coupled fire–atmosphere simulations. The Socorro Mountain was highly complex, with many cliff faces, peaks, and valleys. Although the model captures the magnitude and direction of inlet and outlet areas of the domain, it performs rather poorly in the valley region and in the regions near the steep cliffs. Hence, the model shows good agreement with data in areas of open sloped terrain but lacks in areas where flow separation and thermally driven effects may be present (neither effect was addressed in this work). Results highlight that future work should focus on the implementation of parameterizations of wake-eddies, similar to QUIC-URB’s building parameterizations, and on thermodynamic-driven flow.

54 ENVIRONMENTAL SCIENCES↗

Investigation of a light fixture fire

Metal-halide lamps produce light by discharging an electric arc through a gaseous mixture of vaporized mercury and metal halides. Metal-halide lamps for use in spaces with lower mounting heights can produce excessive visual glare in the normal, higher field-of-view unless they are equipped with prismatic lenses. Should the bulb fail, high internal operating pressure of the arc tube can launch fragments of arc tube at high velocity in all directions, striking the outer bulb of the lamp with enough force to cause the outer bulb to break. This article reports an investigation of a light fixture fire and reviews a case study of a metal-halide lamp fire. We reported on causal analysis of the metal-halide lamp fire uncovered contributing factors that created the environment in which the incident occurred. Latent organizational conditions that created error-likely situations or weakened defenses were identified and controlled. Lastly, effective improvements that reduce the probability or consequence of similar metal-halide lamp fire incidents were implemented.

36 MATERIALS SCIENCE↗

The Latent Dirichlet Allocation model applied to airborne LiDAR data: A case study on mapping forest degradation associated with fragmentation and fire in the Amazon region

1. LiDAR data are being increasingly used to provide a detailed characterization of the vertical profile of forests. This characterization enables the generation of new insights on the influence of environmental drivers and anthropogenic disturbances on forest structure as well as on how forest structure influences important ecosystem functions and services. Unfortunately, extracting information from LiDAR data in a way that enables the spatial visualization of forest structure, as well as its temporal changes, is challenging due to the high dimensionality of these data. 2. In this study, we show how the Latent Dirichlet Allocation model applied to LiDAR data (LidarLDA) can be used to identify forest structural types and how the relative abundance of these forest types changes throughout the landscape. The code to fit this model is made available through the open-source r package LidarLDA in github. We illustrate the use of LidarLDA both with simulated data and data from a large-scale fire experiment in the Brazilian Amazon region. 3. Using simulated data, we demonstrate that LidarLDA accurately identifies the number of forest types as well as their spatial distribution and absorptance probabilities. For the empirical data, we found that LidarLDA detects both landscape-level patterns in forest structure as well as the strong interacting effect of fire and forest fragmentation on forest structure based on the experimental fire plots. More specifically, LidarLDA reveals that proximity to forest edge exacerbates the impact of fires, and that burned forests remain structurally different from unburned areas for at least 7 years, even when burned only once. Importantly, LidarLDA generates insights on the 3D structure of forest that cannot be obtained using more standard approaches that just focus on top-of-the-canopy information (e.g. canopy height models based on LiDAR data). 4. By enabling the mapping of forest structure and its temporal changes, we believe that LidarLDA will be of broad utility to the ecological research community.

54 ENVIRONMENTAL SCIENCES↗

California annual grass phenology and allometry influence ecosystem dynamics and fire regime in a vegetation demography model

Grass-dominated ecosystems cover wide areas of the land surface yet have received far less attention from the Earth System Model (ESM) community. This limits model projections of ecosystem dynamics in response to global change and coupled vegetation–climate dynamics. We used the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), a dynamic vegetation demography model, to determine ecosystem sensitivity to alternate, observed grass allometries and biophysical traits, and evaluated model performance in capturing California C 3 annual grasslands structure and fire regimes. Grass allometry, leaf physiology, plant phenology, and plant mortality all drove the seasonal variation in matter and energy exchange and fire dynamics in California annual grasslands. Allometry influenced grassland structure and function mainly through canopy architecture-mediated space and light competition instead of through carbon partitioning strategy. Regional variation in grassland annual burned area was driven by variation in ecosystem productivity. Our study advances the modeling of grassy ecosystems in ESMs by establishing the importance of grass allometry and plant phenology and mortality in driving C 3 annual grassland seasonal dynamics and fire regime. The calibrated annual grass allometry and biophysical traits presented can be applied in future studies to project climate–vegetation–fire feedbacks in annual grass-dominant ecosystems under global change.

54 ENVIRONMENTAL SCIENCES↗

Medium-Scale Methanol Pool Fire Model Validation

In this work, medium scale (30 cm diameter) methanol pool fires were simulated using the latest fire modeling suite implemented in Sierra/Fuego, a low Mach number multiphysics reacting flow code. The sensitivity of model outputs to various model parameters was studied with the objective of providing model validation. This work also assesses model performance relative to other recently published large eddy simulations (LES) of the same validation case. Two pool surface boundary conditions were simulated. The first was a prescribed fuel mass flux and the second used an algorithm to predict mass flux based on a mass and energy balance at the fuel surface. Gray gas radiation model parameters (absorption coefficients and gas radiation sources) were varied to assess radiant heat losses to the surroundings and pool surface. The radiation model was calibrated by comparing the simulated radiant fraction of the plume to experimental data. The effects of mesh resolution were also quantified starting with a grid resolution representative of engineering type fire calculations and then uniformly refining that mesh in the plume region. Simulation data were compared to experimental data collected at the University of Waterloo and the National Institute of Standards and Technology (NIST). Validation data included plume temperature, radial and axial velocities, velocity temperature turbulent correlations, velocity velocity turbulent correlations, radiant and convective heat fluxes to the pool surface, and plume radiant fraction. Additional analyses were performed in the pool boundary layer to assess simulated flame anchoring and the effect on convective heat fluxes. This work assesses the capability of the latest Fuego physics and chemistry model suite and provides additional insight into pool fire modeling for nonluminous, non-sooting flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic Matter Composition in June 2023 and September 2023 Across the McKenzie Sub-Basin Impacted by the 2020 Holiday Farm Fire

This dataset represents results from a field study aiming to understand the variability in post-fire responses of dissolved organic matter and determine drivers of post-fire responses. Samples were collected at 58 sites within the McKenzie River Watershed (Oregon, USA) that were upstream, within, and downstream of the Holiday Farm Fire burn perimeter. The samples were collected in June 2023 and September 2023 during storm events, approximately 3 years post-fire. Samples were characterized for benezenepolycarboxylic acids (BPCA) and ultra-high resolution mass spectrometry. Dissolved organic carbon and optics (absorbance and fluorescence) data can be found in a separate data packages (https://ir.library.oregonstate.edu/concern/datasets/zc77sz60m, https://ir.library.oregonstate.edu/concern/datasets/mc87q034m). Related data from a subset of sites from 2020-2022 can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1869708 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2478546. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) benzene polycarboxylic acid (BPCA) concentration data; (7) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; (8) folder of high resolution characterization of organic matter via 12 Tesla FTICR-MS data generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Assessment of boreal forest historical C dynamics in Yukon River Basin: relative roles of warming and fire regime change

Carbon (C) dynamics of boreal forest ecosystems have substantial implications for efforts to mitigate the rise of atmospheric CO2 and may be substantially influenced by warming and changing wildfire regimes. In this study we applied a large-scale ecosystem model that included dynamics of organic soil horizons and soil organic matter characteristics of multiple pools to assess forest C stock changes of the Yukon River Basin (YRB) in Alaska, USA, and Canada from 1960 through 2006, a period characterized by substantial climate warming and increases in wildfire. The model was calibrated for major forests with data from long-term research sites and evaluated using a forest inventory database. The regional assessment indicates that forest vegetation C storage increased by 46 Tg C, but that total soil C storage did not change appreciably during this period. However, further analysis suggests that C has been continuously lost from the mineral soil horizon since warming began in the 1970s, but has increased in the amorphous organic soil horizon. Based on a factorial experiment, soil C stocks would have increased by 158 Tg C if the YRB had not undergone warming and changes in fire regime. The analysis also identified that warming and changes in fire regime were approximately equivalent in their effects on soil C storage, and interactions between these two suggests that the loss of organic horizon thickness associated with increases in wildfire made deeper soil C stocks more vulnerable to loss via decomposition. Subbasin analyses indicate that C stock changes were primarily sensitive to the fraction of burned forest area within each subbasin and that boreal forest ecosystems in the YRB are currently transitioning from being sinks to sources at ;0.7% annual area burned. We conclude that it is important for international mitigation efforts focused on controlling atmospheric CO2 to consider how climate warming and changes in fire regime may concurrently affect the CO2 sink strength of boreal forests. It is also important for large-scale biogeochemical and earth system models to include organic soil dynamics in applications to assess regional C dynamics of boreal forests responding to warming and changes in fire regime.

assessment↗

Incidental Reflector Comparison of Containerized Dry Fire Extinguishing Agents

This document addresses the incidental reflector reactivity worth of containerized fire extinguishing agents authorized for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze dry fire extinguishing agent that remains in a container and is not actively being used in a fire emergency. The incidental reflector reactivity worth is determined by comparison to various thicknesses of close fitting water reflection which is commonly used to bound incidental reflectors in criticality safety evaluations. The conclusion is that even in unlimited quantities, when containerized the authorized dry fire extinguishing agents are bound by 0.4 inches of close fitting water.

36 MATERIALS SCIENCE↗

Multi-scale quantification of anthropogenic, fire, and drought-associated forest disturbances across the continental U.S., 2000–2014

Our understanding of broad-scale forest disturbances under climatic extremes remains incomplete. Drought, as a typical extreme event, is a key driver of forest mortality but there have been no reports on continental-scale quantification of its impact on forest mortality or how it compares to other natural or anthropogenic drivers. Thus, our ability to understand and predict broad-scale carbon cycling in response to changing climate and extreme events is limited. In this study, we applied an attribution approach based on different sources of data to quantify the area and potential carbon loss/transfer in continental U.S. (CONUS) from four types of disturbance: (1) anthropogenic (especially timber harvest); (2) fire; (3) drought-associated; and (4) other from 2000 to 2014. Our results showed that anthropogenic disturbances, fire, drought-associated disturbances, and other disturbances accounted for 54.3, 10.7, 12.7, and 22.3% of total canopy area loss, respectively. Anthropogenic disturbance was the most important driver contributing to 58.1% potential carbon loss/transfer in CONUS for 2000–2014. The potential carbon loss/transfer from natural disturbances (fire, drought, and other) for the same study period accounted for approximately 41.9% of the total loss/transfer from all agents, suggesting that natural disturbances also played a very important role in forest carbon turnover. Potential carbon loss/transfer associated with drought accounted for approximately 11.6% of the total loss/transfer in CONUS, which was of similar magnitude to potential carbon loss/transfer from fire (~11.0%). The other natural disturbance accounted for 19.3% of potential carbon loss/transfer. Our results demonstrated the importance of the impacts of various disturbances on forest carbon stocks at the continental scale, and the drought-associated carbon loss/transfer data developed here could be used for evaluating the performance of predictive models of tree mortality under droughts.

54 ENVIRONMENTAL SCIENCES↗

The 1977 tundra fire at Kokolik River, Alaska

During the summer of 1977, fire totaled 44 sq km of tundra vegetation according to measurements using LANDSAT imagery. Based on the experience gained from analysis of this fire using ground observations, satellite imagery, and topographic maps, it appears that natural drainages form effective fire breaks on the subdued relief of the Arctic coastal plain and northern foothills. It is confirmed that the intensity of the fire is related to vegetation type and to the moisture content of the organic rich soils.

Alaska↗

Un-Alerted Smoke and Fire: Checklist Content and Intended Crew Response

An in-flight smoke or fire event is an emergency unlike almost any other. The early cues for un-alerted conditions, such as air conditioning smoke or fire, are often ambiguous and elusive. The checklists crews use for these conditions must help them respond quickly and effectively and must guide their decisions. Ten years ago an industry committee developed a template to guide the content of Part 121 checklists for un-alerted smoke and fire events. This template is based upon a new philosophy about how crews should use the checklists and respond to the events. To determine the degree to which current un-alerted checklists of in-flight smoke or fire comply or are consistent with the guidance outlined in the template, I collected and analysed checklists from North American air carriers.

smoke and fire↗

Landscape Patterns of Burn Severity in the Soberanes Fire of 2016

The Soberanes Fire started on July 22, 2016 in Monterey County on the California Central Coast from an illegal campfire. This fire burned for 10 weeks at a record cost of more than $208 million for protection and control. A progressive analysis of the normalized burn ratio from the Landsat satellite showed that the final high burn severity (HBS) area for the Soberanes Fire comprised 22 percent of the total area burned, whereas final moderate burn severity (MBS) area comprised about 10 percent of the total area burned of approximately 53,470 ha (132,130 acres). The resulting landscape pattern of burn severity classes from the 2016 Soberanes Fire revealed that the majority of HBS area was located in the elevation zone between 500 and 1000 m, in the slope zone between 15 percent and 30 percent, or on south-facing aspects.

Soberanes Fire↗