Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Tension fatigue of glass/epoxy and graphite/epoxy tapered laminates

Symmetric tapered laminates with internally dropped plies were tested with two different layups and two materials, S2/SP250 glass/epoxy and IM6/1827I graphite/epoxy. The specimens were loaded in cyclic tension until they delaminated unstably. Each combination of material and layup had a unique failure mode. Calculated values of strain energy release rate, G, from a finite element analysis model of delamination along the taper, and for delamination from a matrix ply crack, were used with mode I fatigue characterization data from tests of the tested materials to calculate expected delamination onset loads. Calculated values were compared to the experimental results. The comparison showed that when the calculated G was chosen according to the observed delamination failures, the agreement between the calculated and measured delamination onset loads was reasonable for each combination of layup and material.

Murri, Gretchen B.↗

Tension fatigue of glass/epoxy and graphite/epoxy tapered laminates

Symmetric tapered laminates with internally dropped plies were tested with two different layups and two materials, S2/SP250 glass/epoxy and IM6/18271 graphite/epoxy. The specimens were loaded in cyclic tension until they delaminated unstably. Each combination of material and layup had a unique failure mode. Calculated values of strain energy release rate, G, from a finite element analysis model of delamination along the taper, and for delamination from a matrix ply crack, were used with mode I fatigue characterization data from tests of the tested materials to calculate expected delamination onset loads. Calculated values were compared to the experimental results. The comparison showed that when the calculated G was chosen according to the observed delamination failures, the agreement between the calculated and measured delamination onset loads was reasonable for each combination of layup and material.

Murri, Gretchen B.↗

Temperature effects on high strain rate properties of graphite/epoxy composites

A unidirectional graphite epoxy material (AS4/3501-6) was characterized at strain rates ranging from 5 x 10(exp 6) s(exp -1) to 5(exp -1), at room temperature and at 128 C. Results are presented in the form of stress-strain curves to failure. The longitudinal properties remain nearly unchanged with strain rate and temperature. The transverse modulus increases with strain rate but decreases with temperature. The transverse strength and transverse ultimate tensile strain have a positive rate sensitivity at low rates, which changes to negative at intermediate rates and returns to positive rate sensitivity at the highest rates tested. A temperature-time equivalence principle was applied and master curves were obtained for the transverse mechanical properties. The in-plane shear modulus and in-plane shear strength have a positive rate sensitivity. The ultimate intralaminar shear strain has a positive rate sensitivity at low rates, which changes to negative at high rates. At the elevated temperature of 128 C, the ultimate shear strain is 25 to 30 percent higher than the room temperature value, but its strain rate dependence is moderate.

Yaniv, G.↗

Dynamic fracture processes in hydrogen embrittled iron

Mechanistic understanding of hydrogen embrittlement is critical to the transport and storage of hydrogen as a sustainable fuel. Experimental observation of dynamic fracture processes in hydrogen environments has been challenging. Here, in-situ transmission X-ray microscopy is used to image polycrystalline iron foils that are concurrently strained and electrochemically charged with hydrogen. Using this technique, voids and microcracks down to ∼30 nm in size are identified at or near the crack tip and tracked as strain is increased. We observe both hydrogen-induced transgranular failure and hydrogen-induced intergranular failure with distinct fracture processes. We find that transgranular fracture occurs through the formation of sharp branched structures at the main crack tip that are reminiscent of slip band formation. This is followed by void growth and coalescence, and interaction with secondary cracks that lead to propagation of the main crack. Intergranular fracture is found to occur through void coalescence along grain boundaries, along with significant secondary cracking near the crack tip. The crack growth rate is greater for void-mediated intergranular failure than for slip-mediated transgranular failure. Additionally, the removal of hydrogen results in recovered ductility for a crack initially propagated under hydrogen charging.

36 MATERIALS SCIENCE↗

A demonstration of the value of general purpose, on-board satellite computers

Failure of the solar panels to erect and spin stabilize the TRANSIT Improvement Program (TIP) satellites is discussed, with emphasis on how the flight computer was reprogrammed to perform various control functions in order to achieve a partial mission success. These functions include: (1) power management to avoid troublesome spacecraft blackouts; (2) achieve enough spin stability to fire the OATS thruster; (3) raise the parking orbit to a workable altitude; (4) remove a high tumble rate which was the indirect result of the failure; and (5) deploy the gravity-gradient boom successfully on TIP-3.

Jenkins, R. E.↗

Acoustic emission from composite-reinforced metals

Acoustic-emission (AE) count rates are presented for tensile loading of unidirectional boron-epoxy and for aluminum sheets reinforced with unidirectional boron-epoxy. It is shown that different prepreg materials have different characteristic AE patterns. Results from composite-reinforced metal specimens show that early failures are accompanied by a sharp increase in AE count rate at the knee of the bilinear stress-strain diagram. It is further shown that the count rates are a function of specimen fabrication and that higher total counts do not necessarily correspond to early failures.

Henneke, E. G., II↗

Elevated-Temperature "Ultra" Fast Fracture Strength of Advanced Ceramics: An Approach to Elevated-Temperature "Inert" Strength

The determination of "ultra" fast fracture strengths of five silicon nitride ceramics at elevated temperatures has been made by using constant stress-rate ("dynamic fatigue") testing with a series of "ultra" fast test rates. The test material included four monolithic and one SiC whisker-reinforced composite silicon nitrides. Of the five test materials, four silicon nitrides exhibited the elevated -temperature strengths that approaches their respective room-temperature strengths at an "ultra" fast test rate of 3.3 x 10(exp 4) MPa/s. This implies that slow cracks growth responsible for elevated-temperature failure can be eliminated or minimized by using the "ultra" fast test rate. These ongoing experimental results have shed light on laying a theoretical and practical foundation on the concept and definition of elevated-temperature "inert" strength behavior of advanced ceramics.

Choi, S. R.↗

Failure Criterion For Isotropic Time Dependent Materials Which Accounts for Multi-Axial Loading

The Space Shuttle's Reusable Solid Rocket Motor (RSRM) nozzle program has recently conducted testing to characterize the effects of multi-axial loading, temperature and time on the failure characteristics of TIGA321, EA913NA, EA946 (three filled epoxy adhesives). From the test data a "Multi-Axial, Temperature, and Time Dependent" or MATT failure criterion was developed. It is shown that this criterion simplifies, for constant load and constant load rate conditions, into a form that can be easily used for stress analysis. Failure for TIGA321 and EA913NA are characterized below their glass transition temperature. Failure for EA946 is characterized for conditions that pass through its glass transition. The MATT failure criterion is shown to be accurate for a wide range of conditions for these adhesives.

Richardson, D. E.↗

High strain-rate compression behavior of polymeric rod and plate Kelvin lattice structures

The compressive high strain-rate behavior of polymeric Kelvin lattice structures with rod-based or plate-based unit cells was investigated through experimental techniques and finite element simulations. Polymeric lattice structures with 5x5x5 unit cell geometries were manufactured on the millimeter scale using vat polymerization additive manufacturing and tested at low (0.001/s) and high (1000/s) strain-rates. High strain-rate experiments were performed and validated for a viscoelastic split-Hopkinson (Kolsky) pressure bar system (SHPB) coupled with high-speed imaging and digital image correlation (DIC). Experimental results at both low and high strain-rates show the formation of a localized deformation band which was more prevalent in low relative density specimens and low strain-rate experiments. Strain-rate effects of lattice specimens strongly correlate with effects of the base polymer material; both bulk polymer and lattice specimen demonstrated strain-rate hardening, strain-rate stiffening, and decreased fracture strain under dynamic loading. Results show mechanical failure properties and energy absorption depended strongly on the relative density of the lattice specimen and exhibited distinct scaling between relative density and geometry type (rod, plate) and loading rate. High relative density plate-lattices demonstrated inferior mechanical properties to rod-lattices; however, there exists a critical relative density for a given mechanical property (17%- 28%) below which plate-lattices outperform rod-lattices of similar mass. As a result, high strain-rate explicit finite element simulations were performed and showed good agreement with the mechanical failure trends and deformation modes observed in the experiments.

36 MATERIALS SCIENCE↗

A continuum damage approach to spallation and the role of microinertia

Spall failure is of interest due to its prevalence in high strain rate problems in which the spallation is driven by the interaction of release waves. In this article, a porosity-based damage model that includes microinertial effects is used to examine spall failure. The model is successfully calibrated to plate impact-driven experiments and then used to evaluate experimental conditions producing more extreme strain rate conditions, such as those in laser-driven experiments. The incorporation of microinertia allows us to better understand the increase in apparent macroscopic spall strength seen at high strain rates. Correspondingly, we conclude that the incorporation of microinertial effects improves the model’s predictive capabilities. Microinertial effects result in more severe local tensile stresses that affect the damage evolution, and microinertia can play a significant role in the approach to the material’s ideal strength at extreme loading rates. Additionally, a preliminary parametric study is also carried out to investigate the role of microstructural aspects such as nucleation volume fraction and initial pore radius. One counter-intuitive result from the microinertial effects is that, for a given nucleation site volume fraction, having larger initial pore nucleation sites can lead to an improved macroscopic spall strength.

36 MATERIALS SCIENCE↗

Further observations of SCC in alpha-beta brass Considerations regarding the appearance of crack arrest markings during SCC

A series of constant displacement and constant extension rate stress corrosion cracking (SCC) tests was performed on an alpha-beta brass alloy in 1 N Na2SO4 solutions. The chosen mechanical and electrochemical conditions resulted in predominantly transgranular, cleavage-like failure at high (about 8 to 50 microns/s) average crack propagation rates. Crack arrest markings were observed on selected transgranular facets, which almost exclusively bordered regions of ductile overload failure. It is proposed that the observed crack velocities and the specific nature of the arrest mark appearance are most consistent with a cracking mechanism involving adsorption or some other interaction with a damaging environmental species.

Hintz, M. B.↗

The number of catalytic cycles in an enzyme’s lifetime and why it matters to metabolic engineering

Metabolic engineering uses enzymes as parts to build biosystems for specified tasks. Although a part’s working life and failure modes are key engineering performance indicators, this is not yet so in metabolic engineering because it is not known how long enzymes remain functional in vivo or whether cumulative deterioration (wear-out), sudden random failure, or other causes drive replacement. Consequently, enzymes cannot be engineered to extend life and cut the high energy costs of replacement. Guided by catalyst engineering, we adopted catalytic cycles until replacement (CCR) as a metric for enzyme functional life span in vivo. CCR is the number of catalytic cycles that an enzyme mediates in vivo before failure or replacement, i.e., metabolic flux rate/protein turnover rate. We used estimated fluxes and measured protein turnover rates to calculate CCRs for ~100–200 enzymes each from Lactococcus lactis, yeast, and Arabidopsis. CCRs in these organisms had similar ranges (<10 3 to >10 7 ) but different median values (3–4 × 10 4 in L. lactis and yeast versus 4 × 10 5 in Arabidopsis). In all organisms, enzymes whose substrates, products, or mechanisms can attack reactive amino acid residues had significantly lower median CCR values than other enzymes. Taken with literature on mechanism-based inactivation, the latter finding supports the proposal that 1) random active-site damage by reaction chemistry is an important cause of enzyme failure, and 2) reactive noncatalytic residues in the active-site region are likely contributors to damage susceptibility. Enzyme engineering to raise CCRs and lower replacement costs may thus be both beneficial and feasible.

54 ENVIRONMENTAL SCIENCES↗

Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

Long, Edward R., Jr.↗

Tensile properties of an ultrahigh-strength graphite fiber in an epoxy matrix

The fiber performance and reinforcement potential for fiber composites of a special PAN-based graphite fiber were evaluated by testing the fiber's tensile properties in an epoxy matrix. Representative strand samples were taken from 30 spools of single-end, 1500-filament fiber to make over 5000 fiber/epoxy strand specimens using the filament-winding process. Characteristics studied were fiber uniformity, strength and modulus distributions at room and liquid-nitrogen temperatures, stress-strain behavior, the effect of strain rate on fiber strength, and acoustic emission during tensile loading to failure. The fiber was found to have a 3570-MPa failure stress, a 1.7% failure strain, a 206-GPa modulus, and a density of 1.77 Mg/cu m at 23 C. Liquid-nitrogen temperature and various strain rates had no significant effect on fiber tensile properties.

Chiao, T. T.↗

Investigation of Mechanisms of Blade Failure of Forged Hastalloy B and Cast Stellite 21 Turbine Blades in Turbojet Engine

An investigation was conducted to study the mechanisms of blade failure of forged Hastelloy B and cast Stellite 21. The blades were mounted in a 16-25-6 alloy rotor and subjected to 20-minute cycles consisting of 15 minutes at rated speed and approximately 5 minutes at idle. The first failures of the Hastelloy B and Stellite 21 blades were probably the result of excessive vibratory stresses and occurred after 14.25 and 16.75 hours, respectively. After 28.75 hours of operation, all but 3 of the original 25 Hastelloy B blades had either failed or contained stress-rupture-type cracks and four of the original 27 Stellite 21 blades contained stress-rupture-type cracks.

ENGINES, TURBO-JET↗

Reliability Evaluation of Base-Metal-Electrode Multilayer Ceramic Capacitors for Potential Space Applications

Base-metal-electrode (BME) ceramic capacitors are being investigated for possible use in high-reliability spacelevel applications. This paper focuses on how BME capacitors construction and microstructure affects their lifetime and reliability. Examination of the construction and microstructure of commercial off-the-shelf (COTS) BME capacitors reveals great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and 0.5 m, which is much less than that of most PME capacitors. BME capacitors can be fabricated with more internal electrode layers and thinner dielectric layers than PME capacitors because they have a fine-grained microstructure and do not shrink much during ceramic sintering. This makes it possible for BME capacitors to achieve a very high capacitance volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT). Most BME capacitors were found to fail with an early avalanche breakdown, followed by a regular dielectric wearout failure during the HALT test. When most of the early failures, characterized with avalanche breakdown, were removed, BME capacitors exhibited a minimum mean time-to-failure (MTTF) of more than 105 years at room temperature and rated voltage. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically around 12 for a number of BME capacitors with a rated voltage of 25V. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. The leakage current characterization and the failure analysis results suggest that most of these early avalanche failures are due to the extrinsic minor construction defects introduced during fabrication of BME capacitors. The concentration of the extrinsic defects must be reduced if the BME capacitors are considered for high reliability applications. There are two approaches that can reduce or prevent the occurrence of early failure in BME capacitors: (1) to reduce the defect concentration with improved processing control; (2) to prevent the use of BME capacitors under harsh external stress levels so that the extrinsic defects will never be triggered for a failure. In order to do so appropriate dielectric layer thickness must be determined for a given rated voltage.

Liu, David (Donhang)↗

NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test as of 736 kg of Propellant Throughput

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar-electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced mission capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to qualify the thruster propellant throughput capability. The thruster has set electric propulsion records for the longest operating duration, highest propellant throughput, and most total impulse demonstrated. At the time of this publication, the NEXT LDT has surpassed 42,100 h of operation, processed more than 736 kg of xenon propellant, and demonstrated greater than 28.1 MN s total impulse. Thruster performance has been steady with negligible degradation. The NEXT thruster design has mitigated several lifetime limiting mechanisms encountered in the NSTAR design, including the NSTAR first failure mode, thereby drastically improving thruster capabilities. Component erosion rates and the progression of the predicted life-limiting erosion mechanism for the thruster compare favorably to pretest predictions based upon semi-empirical ion thruster models used in the thruster service life assessment. Service life model validation has been accomplished by the NEXT LDT. Assuming full-power operation until test article failure, the models and extrapolated erosion data predict penetration of the accelerator grid grooves after more than 45,000 hours of operation while processing over 800 kg of xenon propellant. Thruster failure due to degradation of the accelerator grid structural integrity is expected after

Shastry, Rohit↗

NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test as of 736 kg of Propellant Throughput

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar-electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced mission capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to qualify the thruster propellant throughput capability. The thruster has set electric propulsion records for the longest operating duration, highest propellant throughput, and most total impulse demonstrated. At the time of this publication, the NEXT LDT has surpassed 42,100 h of operation, processed more than 736 kg of xenon propellant, and demonstrated greater than 28.1 MN s total impulse. Thruster performance has been steady with negligible degradation. The NEXT thruster design has mitigated several lifetime limiting mechanisms encountered in the NSTAR design, including the NSTAR first failure mode, thereby drastically improving thruster capabilities. Component erosion rates and the progression of the predicted life-limiting erosion mechanism for the thruster compare favorably to pretest predictions based upon semi-empirical ion thruster models used in the thruster service life assessment. Service life model validation has been accomplished by the NEXT LDT. Assuming full-power operation until test article failure, the models and extrapolated erosion data predict penetration of the accelerator grid grooves after more than 45,000 hours of operation while processing over 800 kg of xenon propellant. Thruster failure due to degradation of the accelerator grid structural integrity is expected after groove penetration.

Shastry, Rohit↗