Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FUNCTION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Towards Ultra-high-resolution E3SM Land Modeling on Exascale Computers

Here we present an ultra-high-resolution E3SM land model (uELM) for high-fidelity land simulations targeting new Exascale computers. After considering modeling infrastructure compatibility and ELM software features, we designed a parallel model for the uELM development targeting hybrid architectures of new US Exascale computers. We also described a function unit test framework to expedite the piece-wise code porting (with compiler directives), verification, and global variable management. Furthermore, in this study, we report an early uELM model development using OpenACC within a function unit test framework on a pre-Exascale computer, demonstrate the performance of a uLEM submodel with a 3.0-time speedup, and summarize the code porting experience regarding global variable handling, deepcopy, memory reduction, and parallel loop reconstruction.

97 MATHEMATICS AND COMPUTING↗

Evaluating The Relationships Between Supine Propriorception Assessments with Upright Functional Mobility and Balance Tests

INTRODUCTION Upon return to Earth, spaceflight sensorimotor adaptations can result in impaired posture and locomotion [1], [2], and current exercise countermeasures in the International Space Station are not sufficient to maintain sensorimotor function. In-flight countermeasures and assessment tools for sensorimotor function are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to 0.38 G on Mars. One proposed countermeasure for proprioceptive deconditioning includes training on a tilt board device [3], which will be tested in an upcoming bed rest study. In preparation for the said study, the objective of this pilot study is to compare performance in supine proprioceptive assessments to performance in functional upright activities. The results are intended to guide the selection of supine assessment tools for the upcoming bedrest study and the development of future inflight proprioceptive training and assessment tools for exploration missions. METHODS Seventeen healthy participants (8 males and 9 females, 27.9 ± 8.5 years) provided informed consent as approved by the Institutional Review Board (IRB) at NASA. A horizontal air-bearing sled was used to provide a proprioceptive challenge in a supine body orientation, allowing for mediolateral motion with minimal friction during supine stance [4]. Participants were loaded axially (30 to 60% body weight) with their feet on a vertically oriented tilt board and instructed to perform supine assessment activities using custom software that displays a cursor controlled by tilting the tilt board. In a single-leg static activity on the tilt board (TB-St), performance was measured as the percent time spent on a center target during a 30-second trial. During a two-feet dynamic activity on the tilt board (TB-Dy), performance was measured as the number of targets captured in 30 seconds. These supine tasks were compared to performance during two upright activities used to represent upright performance: completion time for a functional mobility task (FMT) [2],[5] and a performance score from force plate sway data during 30-second single-leg upright standing (USL). RESULTS AND DISCUSSION A Spearman's rank-order correlation was run to assess the relationship between upright and supine assessments. There were statistically significant, strong correlations between scores for the FMT and each TB activity, including TB-St, rs(17) = 0.50, p<0.05, TB-Dy3, rs(17) = 0.73, p<0.001, and TB-Dy9, rs(15) = 0.53, p<0.05. There were no statistically significant correlations between USL and each TB activity. Despite a lack of correlation with upright single-leg balance, the ability of the TB to indicate upright performance in the FMT is promising, as this task is a standard post-flight measure designed to characterize locomotor dysfunction [2], [5]. CONCLUSION These efforts will inform the selection of an appropriate sensorimotor assessment method for the upcoming bed rest study and similar future studies. While current work uses a bed rest analog to develop these technologies, future work aims to prepare capabilities for future in-flight sensorimotor training and assessment to mitigate the risks of proprioception impairment after spaceflight. ACKNOWLEDGEMENTS This work was supported by the University Space Research Association Internship Program. REFERENCES [1] Mulavara A.P. et al (2018) Med Sci Sports Exerc, 50(9), 1961-1980. [2] Mulavara A.P. et al (2010) Exp Brain Res, 202(3), 649-659. [3] Macaulay T.R. et al (2021) Front. Syst. Neurosci., 15, 658-985. [4] Goel R. et al (2017) Front. Syst. Neurosci, 11. [5] Koppelmans V. et al (2013) BMC Neurology, 12.

R Bellisle↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

Short Exploration Extravehicular Mobility Unit Testing Setup: Evaluation Under Realistic Pressure and Thermal Conditions

The purpose of Short Exploration Extravehicular Mobility Unit (SxEMU) thermal vacuum testing was to verify the functionality of the Design Verification Testing (DVT) prototype xEMU (SxEMU for this test) at vacuum pressures and extreme space and lunar surface temperature conditions. The SxEMU Thermal Vacuum Test was the culmination of the DVT xEMU project. This paper’s focus is on the pre-Extravehicular Activity (EVA) test setup, and general performance of the SxEMU Portable Life Support Subsystem (xPLSS), with focus on the performance of the Primary Oxygen Assembly (POA) and Secondary Oxygen Assembly (SOA), including Secondary Oxygen Regulator (SOR) takeover and the POA and SOA low-setpoint change inhibit. The initial pre-EVA test preparation included recharging the batteries and replenishing consumables, including test-system water, oxygen assemblies (with gaseous nitrogen), and the integrated thermal loops, including the Feedwater Supply Assemblies. xPLSS functionality testing included carbon dioxide (CO2) removal via the Rapid Cycle Amine swingbed system, thermal loop temperature control, and monitoring of suit ventilation loop pressure, temperature, and CO2 percentages. Testing evaluated automatic takeover of suit pressure control by the SOR after the primary oxygen supply is depleted. The Primary Oxygen Regulator and SOR low-setpoint change inhibit function prevents the crewmember from inadvertently setting the primary regulator to a low pressure setpoint during an EVA.

xPLSS↗

Fermilab's Horizontal Test Stand Upgrade Overview and Commissioning

Cryo-assemblies with the Nb 3 Sn MQXFA low-beta quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab's magnet test facility. A total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational for more than a decade. In order to restore the test stand functions and meet the design and test requirements for the HL-LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded horizontal test stand was completed during the first cryo-assembly test in 2023. These tests verified the major cryo-mechanical installations, as well as the basic test stand operations, including controlled cooldown and operation at 1.9 K, magnet protection and process controls. Here, in this paper, overview of the Fermilab's horizontal test facility upgrade and commissioning of these upgrades are presented.

43 PARTICLE ACCELERATORS↗

Verification of the DIF3D Software to Support Fast Reactor Analysis

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the polynomial order used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification of the DIF3D Software to Support Fast Reactor Analysis

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. As some additional changes have been made to the ARC software since this point all versions between release 3012 and 3266 can be considered verified as version 3253 was used for all updates in this revision. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the methodology used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative noting that DIF3D will properly notify the user when the peaking values it is providing are potentially incorrect.

97 MATHEMATICS AND COMPUTING↗

Verification of the DIF3D Software to Support Fast Reactor Analysis (Rev. 3)

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. As some additional changes have been made to the ARC software since this point all versions between release 3012 and 3266 can be considered verified as version 3253 was used for all updates in this revision. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the methodology used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative noting that DIF3D will properly notify the user when the peaking values it is providing are potentially incorrect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fermilab’s horizontal test stand upgrade overview and commissioning

Cryo-assemblies with the low-beta Nb3Sn quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab’s magnet test facility. Total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational more than a decade. In order to restore the test stand functions and meet the design and test requirements for the high luminosity LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded test stand was completed during the first cryo-assembly test in 2023. These tests verified all the cryo-mechanical installations, as well as the test stand operations, including controlled cooldown and operation at 1.9 K, the helium recovery capabilities, magnet protection and process controls.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solar-electric propulsion breadboard thrust subsystem

A solar-electric propulsion breadboard thrust subsystem has been designed, built, and tested. A 1500-h test was performed to demonstrate the functional capabilities of the subsystem. Described are the subsystem functions and testing process. The results show that the ground work has been established for development of an engineering model of the thrust subsystem.

Masek, T. D.↗

An antenna pointing mechanism for large reflector antennas

An antenna pointing mechanism for large reflector antennas on direct broadcasting communication satellites was built and tested. After listing the requirements and constraints for this equipment the model is described, and performance figures are given. Futhermore, results of the qualification level tests, including functional, vibrational, thermovacuum, and accelerated life tests are reported. These tests were completed successfully.

Heimerdinger, H.↗

Characterization of elastomeric materials with application to design

Redesign of the Space Shuttle Solid Booster has necessitated re-evaluation of the material used in the field joint O-ring seals. The viscoelastic characteristics of five candidate materials were determined. The five materials are: two fluorocarbon compounds, two nitrile compounds, and a silicon compound. The materials were tested in a uniaxial compression test to determine the characteristic relaxation functions. These tests were performed at five different temperatures. A master material curve was developed for each material from the experimental data. The results are compared to tensile relaxation tests. Application of these results to the design analysis is discussed in detail.

Bower, Mark V.↗

Viscoelastic properties of elastomeric materials for O-ring applications

Redesign of the Space Shuttle Solid Rocket Booster necessitated re-evaluation of the material used in the field joint O-ring seals. This research project was established to determine the viscoelastic characteristics of five candidate materials. The five materials are: two fluorocarbon compounds, two nitrile compounds, and a silicon compound. The materials were tested in a uniaxial compression test to determine the characteristic relaxation functions. These tests were performed at five different temperatures. A master material curve was developed for each material from the experimental data. The results of this study are compared to tensile relaxation tests. Application of these results to the design analysis is discussed in detail.

Bower, Mark V.↗

Efficient Evaluation and Optimization of Structural Reliability

Use of approximations for calculating the structural failure probability under uncertainties is a necessary aspect. But efficient use of suitable approximations at different stages of reliability prediction and design makes this valuable tool practical for many large scale structures. This research addresses the modern approximation concepts and their utility in structural reliability estimation. Emphasis is placed on building higher order approximations using intervening variables to closely represent the nonlinear limit state functions. Several test problems with highly nonlinear performance functions are used to demonstrate the accuracy of the proposed method. Many of the structural problems are modeled and simulated using the finite element methods (FEM) for obtaining a detailed structural response. FEM is a computationally intensive numerical procedure with a large number of degrees of freedom. With an increase in the complexity of the structural model and the multidisciplinary nature of analyses, the number of limit states and their computation increases very significantly. The requirement of frequent repetitive analysis of the structure hinders the utility of any tool and discourages that approach from being used. One particular tool which faces this difficulty is the computation of the structural reliability under parametric uncertainties.

Grandhi, Ramana V.↗

Evaluating the Relationships Between Supine Propriorception Assessments With Upright Functional Mobility and Balance Tests

- Sensorimotor adaptations during spaceflight can result in impaired posture and locomotion upon return to Earth. - In-flight sensorimotor countermeasures and assessment tools are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to Mars. - The tilt board (Fig. 1) is proposed as an inflight proprioceptive countermeasure and will be tested in an upcoming bed rest study. - Proprioceptive assessments on the tilt board may also help predict post-flight and post-bedrest functional task performance.

Rachel F. Bellisle↗

Deep Bed Adsorption Testing using Silver-Functionalized Aerogel

Nuclear fission results in the production of fission products and activation products, some of which tend to be volatile during used fuel reprocessing and evolve in gaseous species into the reprocessing facility off-gas systems. Analyses have shown that I129, due to its radioactivity, high potential mobility in the environment, and high longevity (half life of 15.7 million years), can require control efficiencies of up to 1,000x or higher to meet regulatory emission limits. Two Aerogel sorption tests that have been performed this fiscal year. The maximum iodine decontamination factor (DF) was measured to be over 10,000, above the 1,000-10,000 target DF range. The mass transfer zone may be as short as 0.5 inches under the sorption conditions of the first test. Only a small fraction of the iodine sorbed on Bed 1 was desorbed during the purge periods. The silver-functionalized Aerogel appears to have potential to be a very effective and efficient iodine sorbent.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anharmonic Rovibrational Partition Functions at High Temperatures: Tests of Reduced-Dimensional Models for Systems with up to Three Fluxional Modes

In this work, curvilinear coordinate Monte Carlo phase space integration and a series of full-dimensional fitted potential energy surfaces are used to study the effectiveness of reduced-dimensional models for predicting rovibrational anharmonicity at high temperatures. Fully coupled and fully anharmonic, but classical, rovibrational partition functions Q are computed for 14 species with two or three fluxional modes (inversions or torsions) and as many as 30 degrees of freedom. These results are converted to semiclassical anharmonicity correction factors f and are analyzed alongside results obtained previously for 22 species with up to two fluxional modes. As expected, fluxional species show considerable variation in f at high temperatures; f is as small as 0.2 for acetone and is as large as 9 for methylene glycol at 2500 K. This set of full-dimensional results is used to test the accuracy of reduced-dimensional models where fluxional modes are treated as coupled to one another but as separable from the remaining nonfluxional modes. For most systems, we find that such an approximation is accurate at high temperatures, with average errors in Q of just similar to 25%. For some systems, however, larger errors are found, and these are attributed to strong coupling of the fluxional modes to one or more nonfluxional modes. In particular, we identify strong coupling to low-frequency bends for some systems, and we show that by comparing curvilinear and rectilinear harmonic frequencies for the fluxional modes, we can estimate the effect of this coupling on rovibrational anharmonicity. We also quantify the accuracy of the more severe but common assumption of treating fluxional modes as separable from one another, that is, as sets of uncoupled one-dimensional inversions and torsions. This approach can work well for methyl and alkyl rotors, but it is shown to have errors as large as a factor of 7 at high temperatures for more complex systems. Lastly, we note that while the present analysis focuses on the treatment of fluxional modes, the collective anharmonicity correction associated with the more numerous nonfluxional modes, although simpler to describe, comprises a significant fraction of the overall anharmonicity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗