System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam G.↗

Controllable Grid Interface for Testing Ancillary Service Controls and Fault Performance of Utility-Scale Wind Power Generation: Preprint

The rapid expansion of wind power has led many transmission system operators to demand modern wind power plants to comply with strict interconnection requirements. Such requirements involve various aspects of wind power plant operation, including fault ride-through and power quality performance as well as the provision of ancillary services to enhance grid reliability. During recent years, the National Renewable Energy Laboratory (NREL) of the U.S. Department of Energy has developed a new, groundbreaking testing apparatus and methodology to test and demonstrate many existing and future advanced controls for wind generation (and other renewable generation technologies) on the multimegawatt scale and medium-voltage levels. This paper describes the capabilities and control features of NREL's 7-MVA power electronic grid simulator (also called a controllable grid interface, or CGI) that enables testing many active and reactive power control features of modern wind turbine generators -- including inertial response, primary and secondary frequency responses, and voltage regulation -- under a controlled, medium-voltage grid environment. In particular, this paper focuses on the specifics of testing the balanced and unbalanced fault ride-through characteristics of wind turbine generators under simulated strong and weak medium-voltage grid conditions. In addition, this paper provides insights on the power hardware-in-the-loop feature implemented in the CGI to emulate (in real time) the conditions that might exist in various types of electric power systems under normal operations and/or contingency scenarios. Using actual test examples and simulation results, this paper describes the value of CGI as an ultimate modeling validation tool for all types of 'grid-friendly' controls by wind generation.

17 WIND ENERGY↗

Analysis methods for wind turbine control and electrical system dynamics

The integration of new energy technologies into electric power systems requires methods which recognize the full range of dynamic events in both the new generating unit and the power system. Since new energy technologies are initially perceived as small contributors to large systems, little attention is generally paid to system integration, i.e. dynamic events in the power system are ignored. As a result, most new energy sources are only capable of base-load operation, i.e. they have no load following or cycling capability. Wind turbines are no exception. Greater awareness of this implicit (and often unnecessary) limitation is needed. Analysis methods are recommended which include very low penetration (infinite bus) as well as very high penetration (stand-alone) scenarios.

Hinrichsen, E. N.↗

Paschen Considerations for High Altitude Airships

Recently, there have been several proposals submitted to funding agencies for long-lived high altitude (about 70,000 feet) airships for communications, surveillance, etc. In order for these airships to remain at altitude, high power, high efficiency, lightweight solar arrays must be used, and high efficiency power management and distribution systems must be employed. The needs for high power and high efficiency imply high voltage systems. However, the air pressure at these extreme altitudes is such that electrical power systems will be near the Paschen discharge minimum over a wide range of electrode separations. In this paper, preliminary calculations are made for acceptable high voltage design practices under ambient, hydrogen and helium gas atmospheres.

Ferguson, D. C.↗

Financing Federal Microgrids [Slides]

A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. When components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs, implementation by one of several privately financed federal procurement mechanisms is possible. However, it is typically difficult to achieve enough savings and avoided costs to cover the design, equipment, and installation of certain microgrid components that are required to integrate the system. This presentation explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrified Aircraft Propulsion Controls Hardware Testing

Electrified Aircraft Propulsion (EAP) systems hold potential for the reduction of aircraft fuel burn and emissions. To realize this potential for single-aisle aircraft, control technology challenges associated with EAP designs are increasing the demand for Hardware-In-the-Loop (HIL) studies that address the tightly coupled electrical powertrain and turbofan propulsion systems. Reconfigurable HIL testbeds enable the study of integrated supervisory control and control approaches that augment engine shaft torques to improve performance. This paper presents an overview of conceptual EAP controls architecture testing in two HIL testbeds. The NASA Electric Aircraft Testbed provides the ability for megawatt class electric powertrain testing for technology maturation. A 100 kilowatt testbed, the Hybrid Propulsion Emulation Rig, allows for rapid controls technology trade studies. In both testbeds, controls testing is performed by implementing the electrical power system in hardware while turbomachinery is emulated via electric machines that are commanded by a real-time model and controls. A novel scaling algorithm is applied to emulate the inertial loads of the turbomachinery that causes the electric machines to respond in a fashion similar to that of the full-scale propulsion system they represent. Results demonstrate desired control performance at both testbed scales for the conceptual EAP architecture.

Electrified Aircraft Propulsion↗

Electrified Aircraft Propulsion Controls Hardware Testing

Electrified Aircraft Propulsion (EAP) systems hold potential for the reduction of aircraft fuel burn and emissions. To realize this potential for single-aisle aircraft, control technology challenges associated with EAP designs are increasing the demand for Hardware-In-the-Loop (HIL) studies that address the tightly coupled electrical powertrain and turbofan propulsion systems. Reconfigurable HIL testbeds enable the study of integrated supervisory control and control approaches that augment engine shaft torques to improve performance. This paper presents an overview of conceptual EAP controls architecture testing in two HIL testbeds. The NASA Electric Aircraft Testbed provides the ability for megawatt class electric powertrain testing for technology maturation. A 100 kilowatt testbed, the Hybrid Propulsion Emulation Rig, allows for rapid controls technology trade studies. In both testbeds, controls testing is performed by implementing the electrical power system in hardware while turbomachinery is emulated via electric machines that are commanded by a real-time model and controls. A novel scaling algorithm is applied to emulate the inertial loads of the turbomachinery that causes the electric machines to respond in a fashion similar to that of the full-scale propulsion system they represent. Results demonstrate desired control performance at both testbed scales for the conceptual EAP architecture.

Electrified Aircraft Propulsion↗

iROSA Computational Model Development and Integration for the International Space Station

The power generation capability of the International Space Station (ISS) is being augmented with the installation of new solar arrays. The new solar arrays, named iROSA (ISS Roll Out Solar Array), are installed in front of original main truss solar arrays and integrate into the existing structure and electrical power system of the ISS. However, iROSA represents significant changes in technology for solar arrays compared to the original solar arrays on the ISS main truss. Knowing the power capabilities of the augmented solar arrays is critical for near-term and long-term mission planning and utilization. This new iROSA installation thus requires updates to be made to the prior-day methods of calculating power generation capability for the ISS. New types of solar cells and array designs, both electrically and structurally, present challenges for concurrent computational modeling of both the original solar arrays and the newer iROSA. This presentation will detail the development and integration of the computational models to calculate the power for the augmented arrays on ISS and the evaluation of the model to ensure that it functions with and without iROSA and returns accurate predictions of power generation in nominal and off-nominal conditions.

International Space Station↗

Study on Conversion from an Existing Alternating Current Medium-Voltage Line to a Direct Current Line: A Case of Load or Source Expansion

Simultaneous increase of power generation through renewable systems and load due owing to the rapid growth in electrified road transportation systems, leads to new challenges in the design, operation, and protection of distribution-level electrical power systems. This paper addresses challenges related to the integration of new sources or loads to a distribution grid through long alternating current lines. The International Council on Large Electric Systems medium-voltage benchmark model developed for North America was used for simulation studies. Use cases were developed to illuminate the issues related to long alternating current lines and the usefulness of medium-voltage direct current lines in a distribution network.

Jaldanki, Sreenivasa↗

Analysis of Glint During the Artemis I Mission

Glint occurs when light reflects off a specular (mirror-like) surface. In the context of spacecraft, glinted light can land in places that may cause unintended negative effects. During the Artemis I mission in November and December of 2022, the Orion vehicle was configured intentionally to cause glint to occur to study its effect on the Orion electrical power system (EPS). With the vehicle in a nose-to-sun attitude, light was reflected off the crew module’s reflective skin and onto forward-pointed solar array wings (SAWs), producing more current than would result from direct solar flux alone. Along with this flight test, glint was unexpectedly observed several other times during the mission, primarily due to light reflecting from one SAW to another. The planned glint events helped to anchor the models previously used to study this phenomenon and to understand what parameters have the most significant impact on glinted current generation. With refined models, the SAW-to-SAW glint occurrences were studied with the goal of characterizing its potential impact on vehicle operation.

Photovoltaic↗

Carolina Offshore Wind Integration Case Study: Phases I and II Final Technical Report

Duke Energy performed a phase 1 study to assess the impact of offshore wind development in the waters off the coasts of North Carolina and South Carolina. The study analyzed the impacts to the Duke Energy Carolinas electric power system of multiple wind deployment scenarios. Focusing on an integrated utility system in the Carolinas provided a unique opportunity to assess the impacts of offshore wind development in a region that has received less attention regarding renewables than others in the US. North Carolina is the only state in the Southeastern United States that currently has a renewable portfolio standard (RPS) which requires that 12.5% of the state’s total energy requirements be met with renewable resources by 2021. 12.5% of the state’s total energy requirements in 2021 equates to approximately 17,000 GWH of energy needed from renewable resources. Wind resources represent one of the ways to potentially meet this requirement. The study builds upon and augments ongoing work, including a study by UNC to identify potential wind development sites and the analysis of impacts to the regional transmission system performed by the NCTPC, an Order 890 planning entity of which DEC is a member. Furthermore, because the region does not have an independent system operator (ISO) or regional transmission organization (RTO), the study will provide additional information unique to non-RTO/ISO systems. The Phase 2 study builds on the results of Phase 1 and investigates the dynamic stability of the electrical network in Task 4, the operating characteristics of the wind turbines as they impact operating reserve requirements of the DEC utility in Task 5, and the production cost of integrating the offshore wind resources into the DEC generation fleet making comparisons to future planned operation without the addition of the wind resources in Task 6.

17 WIND ENERGY↗

Fundamental Drivers of the Cost and Price of Operating Reserves

Operating reserves impose a cost on the electric power system by forcing system operators to keep partially loaded spinning generators available for responding to system contingencies variable demand. In many regions of the United States, thermal power plants provide a large fraction of the operating reserve requirement. Alternative sources of operating reserves, such as demand response and energy storage, may provide more efficient sources of these reserves. However, to estimate the potential value of these services, the cost of reserve services under various grid conditions must first be established. This analysis used a commercial grid simulation tool to evaluate the cost and price of several operating reserve services, including spinning contingency reserves and upward regulation reserves. These reserve products were evaluated in a utility system in the western United States, considering different system flexibilities, renewable energy penetration, and other sensitivities. The analysis demonstrates that the price of operating reserves depend highly on many assumptions regarding the operational flexibility of the generation fleet, including ramp rates and the fraction of fleet available to provide reserves.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Array Performance Modeling for NASA’s Artemis Missions

NASA’s Artemis exploration campaign includes multiple elements that utilize photovoltaic power generation. Artemis mission profiles feature a variety of events that can limit solar array generation and stress electrical power system (EPS) performance, including eclipses, propulsive or navigational maneuvers which constrain the positioning of the solar arrays, and spiral trajectories with significant radiation degradation. These features make predicting the performance of the power system particularly important and requires accurate modeling of power generation by the solar arrays under a variety of conditions. One of the tools used to predict spacecraft EPS performance is the System Power Analysis for Capability Evaluation (SPACE) model developed at NASA Glenn Research Center. SPACE is used by NASA to model EPS performance for the Orion crew transport vehicle and the Power and Propulsion Element (PPE) of the Gateway space station. This presentation will provide an overview of how SPACE calculates solar array performance, including degradation factors considered and environmental conditions that drive the solar array designs. Additionally, Orion array performance predictions generated by SPACE will be compared to flight data collected during the Artemis I mission.

Photovoltaic↗

Analysis of Glint During the Artemis I Mission

Glint occurs when light reflects off a specular (mirror-like) surface. In the context of spacecraft, glinted light can land in places that may cause unintended, negative effects. During the Artemis I mission in November and December of 2022, glint was forced to occur in order to study its effect on the Orion electrical power system (EPS). With the vehicle in a nose-to-sun attitude, light was reflected off the crew module’s reflective skin and onto forward pointed solar array wings (SAWs), producing more current than would result from direct solar flux alone. The goal of this in-flight test was to anchor the models previously used to study this phenomenon and to understand what parameters have the most significant impact on glinted current generation. In this presentation, the two models used for estimating optical properties for glint analysis will be discussed, as well as a worst-case study that was performed before the Artemis I mission. In-flight telemetry data will be compared to values of SAW section current produced by the models. Each of the optical properties and parameters studied will be outlined and their significance on the impact of glint will be discussed.

Glint↗

It's Indisputable: Five Facts About Planning and Operating Modern Power Systems

An indisputable fact cannot be rebutted. It is supported by theory and experience. Over the past 25 years, wind and solar generation has undergone dramatic growth, resulting in a variety of experiences that model the integration of wind and solar into the planning and operation of modern electric power systems. In this article, we bring together examples from Europe, North America, and Australia to identify five indisputable facts about planning and operating modern power systems. Taken together, we hope these experiences can help build consensus among the engineering and public policy communities about the current state of wind and solar integration and also facilitate conversations about evolving future challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Hydropower Representation in Power System Models (Summary of Technical Workshop)

In March 2019, Pacific Northwest National Laboratory (PNNL) and National Renewable Energy Laboratory (NREL) held a workshop to discuss the characterization of hydropower resources within electric power system models. The workshop took place at the Western Electricity Coordinating Council in Salt Lake City, Utah, and was sponsored by the Water Power Technologies Office of the US Department of Energy. The intention of the workshop is to support the federal energy research initiative HydroWIRES. The Initiative has a specific technical objective to advance the representation of hydropower resources in relevant water and power models and to address the seams between the two. This report describes the workshop, contributions from attendees, a summary of the findings of the event and proposed next steps. The themes and recommendations from this workshop have provided foundational guidance for future research and program strategy.

13 HYDRO ENERGY↗

Near-term implications of a ban on new coal-fired power plants in the United States

Large numbers of proposed new coal power generators in the United States have been cancelled, and some states have prohibited new coal power generators. We examine the effects on the U.S. electric power system of banning the construction of coal-fired electricity generators, which has been proposed as a means to reduce U.S. CO{sub 2} emissions. The model simulates load growth, resource planning, and economic dispatch of the Midwest Independent Transmission System Operator (ISO), Inc., Electric Reliability Council of Texas (ERCOT), and PJM under a ban on new coal generation and uses an economic dispatch model to calculate the resulting changes in dispatch order, CO{sub 2} emissions, and fuel use under three near-term (until 2030) future electric power sector scenarios. A national ban on new coal-fired power plants does not lead to CO{sub 2} reductions of the scale required under proposed federal legislation such as Lieberman-Warner but would greatly increase the fraction of time when natural gas sets the price of electricity, even with aggressive wind and demand response policies. 50 refs., 5 figs., 4 tabs.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.