Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The high-energy pulsed X-ray spectrum of Hercules X-1 as observed with OSO 8

Hercules X-1 was observed from August 30 to September 10, 1977, by using the high-energy X-ray scintillation spectrometer on board the OSO 8 satellite. The observation, during which the source was monitored continually for nearly an entire ON-state, covered the energy range from 16 to 280 keV. Pulsed-flux measurements as a function of binary orbit and binary phase are presented for energies between 16 and 98 keV. The pulsed flux between 16 and 33 keV exhibited a sharp decrease following the fourth binary orbit and was consistent with zero pulsed flux thereafter. Only weak evidence was found for temporal variation in the pulsed flux between 33 and 98 keV. The pulsed spectrum has been fitted with a power law, a thermal spectrum without features, and a thermal spectrum with a superposed Gaussian centered at 55 keV. The latter fit has the smallest value of chi-square per degree of freedom, and the resulting integrated line intensity is approximately 0.0015 photon/sec per sq cm for a width of 3.1 (+9.1, -2.6) keV. This result, while of low statistical significance, agrees with the value observed by Truemper (1978) during the same ON-state.

Maurer, G. S.↗

Digest of celestial X-ray missions and experiments

Information on instruments, the platforms that carried them, and the data they gathered is presented. Instrument selection was confined to detectors operating in the 0.20 to 300 keV range. Included are brief descriptions of the spacecraft, experiment packages and missions. Cross-referenced indexes are provided for types of instruments, energy ranges, time spans covered, positional catalogs and observational catalogs. Data sets from these experiments (NSSDC) are described.

Locke, M. C.↗

A high-resolution measurement of the 2.223 MeV neutron capture line in a solar flare

An intense solar flare lasting 40 s was observed by the HEAO 3 gamma-ray spectrometer on November 9, 1979, at 3:05 UT. The flare was observed in four high-resolution germanium detectors as well as in five CsI shield detectors over an energy range of 100 keV to above 5 MeV. Of particular interest is a line feature at 2.2248 + or - 0.0010 MeV. The precise energy measurement provides unambiguous evidence that this is the (H-1)(n, gamma)(H-2) line resulting from neutron capture on hydrogen. An upper limit of 5 keV is found for the natural line width. The time dependence of the neutron capture line is discussed as well as the overall characteristics of the November 9 flare.

Prince, T. A.↗

Total electron scattering cross sections. I - He, Ne, Ar, Xe

The apparatus and experimental procedures used to obtain total electron scattering cross sections are described, and results are presented for He, Ne, Ar and Xe in the 4-300 eV incident energy range, together with statistical errors. The results are generally found to be in good agreement with previous data except at low impact energies. Serious discrepancies remain in Xe below 20 eV impact energy.

Nickel, J. C.↗

Gamma-ray bursts and radio pulsar glitches

Upper limits to gamma-ray fluxes produced in conjunction with a radio pulsar glitch are presented. The glitch occurred on the Vela pulsar on December 24, 1988 and was the first to be observed as it occurred. Sensitive gamma-ray burst detectors aboard the Phobos 2 spacecraft were operating at this time, but recorded no significant burst at the time of the glitch. It is concluded that if a gamma-ray burst was generated in the energy range to which the Phobos detectors were sensitive, and if it was not beamed away from the spacecraft, the efficiency of glitch energy conversion into gamma-rays could not have exceeded 10 exp -4.

Hartmann, D.↗

The Energy Spectra of Proton and Helium Measured from the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon experiment is designed to investigate the composition and energy spectra of cosmic rays at the highest energies currently accessible from direct measurements, the region up to 100 TeV. The instrument consists of a silicon matrix for charge measurement, a graphite target (0.75 nuclear interaction length) to induce hadronic fragmentation, 3 scintillator strip hodoscopes for triggering and helping reconstruct trajectory, and a BGO calorimeter (18 radiation lengths) to measure the energy of incident particles. ATIC had two successful Long Duration Balloon (LDB) flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We present the energy spectra of proton and helium extracted from the ATIC flights, over the energy range from 100 GeV to 100 TeV, and compare them with the results from other experiments at both the lower and higher energy ends.

Ahn, H. S.↗

Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

Smith, S. J.↗

Design and Performance of the GAMMA-400 Gamma-Ray Telescope for Dark Matter Searches

The GAMMA-400 gamma-ray telescope is designed to measure the fluxes of gamma-rays and cosmic-ray electrons (+) positrons, which can be produced by annihilation or decay of the dark matter particles, as well as to survey the celestial sphere in order to study point and extended sources of gamma-rays, measure energy spectra of Galactic and extragalactic diffuse gamma-ray emission, gamma-ray bursts, and gamma-ray emission from the Sun. GAMMA-400 covers the energy range from 100 MeV to 3000 GeV. Its angular resolution is approximately 0.01deg (E(sub gamma) greater than 100 GeV), the energy resolution approximately 1% (E(sub gamma) greater than 10 GeV), and the proton rejection factor approximately 10(exp 6). GAMMA-400 will be installed on the Russian space platform Navigator. The beginning of observations is planned for 2018.

Dark Matter↗

Performance Assessment of Different Pulse Reconstruction Algorithms for the ATHENA X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) microcalorimeter, on-board Athena, with its focal plane comprising 3840 Transition Edge Sensors (TESs) operating at 90 mK, will provide unprecedented spectral-imaging capability in the 0.2-12 keV energy range. It will rely on the on-board digital processing of current pulses induced by the heat deposited in the TES absorber, as to recover the energy of each individual events. Assessing the capabilities of the pulse reconstruction is required to understand the overall scientific performance of the X-IFU, notably in terms of energy resolution degradation with both increasing energies and count rates. Using synthetic data streams generated by the X-IFU End-to-End simulator, we present here a comprehensive benchmark of various pulse reconstruction techniques, ranging from standard optimal filtering to more advanced algorithms based on noise covariance matrices. Beside deriving the spectral resolution achieved by the different algorithms, a first assessment of the computing power and ground calibration needs is presented. Overall, all methods show similar performances, with the reconstruction based on noise covariance matrices showing the best improvement with respect to the standard optimal filtering technique. Due to prohibitive calibration needs, this method might however not be applicable to the X-IFU and the best compromise currently appears to be the so-called resistance space analysis which also features very promising high count rate capabilities.

microcalorimeters↗

A consistent, Bayesian, approach to the cross section probability distribution in the unresolved resonance region

The cross sections of neutron-induced reactions can be divided into three energy ranges: the resolved resonance region (RRR), the unresolved resonance region (URR), and the fast region. In general, the cross sections in the URR show significant fluctuations that cannot be predicted and cannot be experimentally resolved, thus, it is commonly assumed that the cross section at a specific energy is given by a probability distribution function (PDF) over a range of values that can span several orders of magnitude. The current methodology used to describe such behavior is to construct the PDF by stochastically generating resonance ladders and numerically measuring the PDF. The resonance ladders are sampled using known resonance statistical properties and average resonance widths and spacings extrapolated from the RRR. Although this is a standard and widely used technique, it is computationally very expensive, therefore, an alternative, analytical, approach would be preferable due to the considerable speed up of the computational time in real life applications. Moreover, the current methodology does not take into account existing experimental data, such for total and capture cross sections, that are available for many nuclei. Finally, this approach was developed to be used in reactor-scale applications and it is not suited for use in single-event applications. In this work we will rethink the entire approach to the PDF construction using a Bayesian mindset. This will allow us to provide a different definition of the PDF that allows a much faster calculation of the higher-temperature PDFs and a proper combination of theoretical and experimental PDFs following the probability theory. We will also show that our definition is well suited for single-event applications and we will make an explicit connection between our method and the standard approach. We do this by showing that the central limit theorem applies and our method leads to the same PDF obtained with the standard methodology, for a large number of events per history.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlling Factors of Chorus Spectral Gaps

Abstract The present study compares a single‐band chorus wave against a banded chorus wave observed by Van Allen Probes at adjacent times, and demonstrates that the single‐band chorus wave is associated with an anisotropic electron population over a broad energy range, while the banded chorus wave is accompanied by an electron phase space density plateau and an electron anisotropy reduction around Landau resonant energies. We further compare banded chorus waves with different spectral gap widths, and show that a wider spectral gap is associated with electron isotropization extending to higher energies with respect to the equatorial Landau resonant energy. We suggest that early generated chorus waves isotropize electrons via Landau resonant acceleration, and the waves that propagate to higher latitudes isotropize electrons at higher energies. The isotropization extending to higher energies leads to a larger spectral gap of new chorus waves after electrons bounce back to the equator.

Li, Jinxing↗

Highly ordered graphite (HOPG) to hexagonal diamond (lonsdaleite) phase transition observed on picosecond time scales using ultrafast x-ray diffraction

Here, the response of rapidly compressed highly oriented pyrolytic graphite (HOPG) normal to its basal plane was investigated at a pressure of ~80 GPa. Ultrafast x-ray diffraction using ~100 fs pulses at the Materials Under Extreme Conditions sector of the Linac Coherent Light Source was used to probe the changes in crystal structure resulting from picosecond timescale compression at laser drive energies ranging from 2.5 to 250 mJ. A phase transformation from HOPG to a highly textured hexagonal diamond structure is observed at the highest energy, followed by relaxation to a still highly oriented, but distorted graphite structure following release. We observe the formation of a highly oriented lonsdaleite within 20 ps, subsequent to compression. This suggests that a diffusionless martensitic mechanism may play a fundamental role in phase transition, as speculated in an early work on this system, and more recent static studies of diamonds formed in impact events.

58 GEOSCIENCES↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Dipole response in Te 128 , 130 below the neutron threshold

Numerous studies of the ground-state decay of the pygmy dipole resonance (PDR) have been carried out in the past. However, data on the decay of the PDR to low-lying excited states is still very scarce due to limitations of the sensitivity to weak branching transitions of experimental setups. Here, we present a detailed examination of the low-energy dipole response of 128 Te and 130 Te below their neutron separation thresholds of 8.8 and 8.5 MeV, respectively. Photonuclear reactions with the subsequent γ-ray spectroscopy of the decay channel with continuous-energy bremsstrahlung at varying endpoint energies and linearly polarized quasimonochromatic γ-ray beams with energies ranging from 2.7 to 8.9 MeV in steps of roughly 250 keV were used for probing the decay behavior of the low-energy dipole response in 128Te and 130Te. In addition, (γ,γ' γ") reactions were used to study the population of low-lying states of 128 Te. Spin-parity quantum numbers and reduced transition probabilities are determined for individual photo-excited states. The analysis of average decay properties for nuclear levels in narrow excitation-energy bins enable the extraction of photoabsorption cross sections, average branching ratios to the $2$$^{+}_{1}$ state, and the distinction between E1 and M1 transitions to the ground state and to the $2$$^{+}_{1}$ state accounting for resolved and unresolved transitions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Status of the Energy Calibration, Polarization and Monochromatization of the FCC-ee

The Future Circular electron-positron Collider, FCC- ee, is designed for unprecedented precision for particle physics experiments from the Z-pole up to above the top-pair-threshold, corresponding to a beam energy range from 45.6 to 182.5 GeV. Performing collisions at various particle-physics resonances requires precise knowledge of the centre-of-mass energy (ECM) and collision boosts at all four interaction points. Measurement of the ECM by resonant depolarization of transversely polarized pilot bunches in combination with a 3D polarimeter, aims to achieve a systematic uncertainty of 4 and 100 keV for the Z-pole and W-pair-threshold energies respectively. The ECM itself depends on the RF-cavity locations, beamstrahlung, longitudinal impedance, the Earth’s tides, opposite sign dispersion and possible collision offsets. Application of monochromatization schemes are envisaged at certain beam energies to reduce the energy spread. The latest results of studies of the energy calibration, polarization and monochromatization are reported here.

43 PARTICLE ACCELERATORS↗

Electron Energy Regression in High-Granularity Calorimeter Prototype

The dataset consists of simulations of calibrated reconstructed hits produced by a positron passing through the HGCAL test beam prototype. For the simulations, Monte Carlo method is used to produce the positrons with energy ranging from 10 to 350 GeV. The dataset contains the coordinates of the calibrated reconstructed hits in the prototype along with the calibrated energy in units of MIP. The HDF5 files can be extracted from the gzip files.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma radiation from the Crab nebula above 35 MeV

Electromagnetic radiation from the Crab nebula were observed, showing that the Crab is unique among strong X-ray sources in that major component in the low energy range (1 to 10 KeV) shows little or no temporal variation. Observations of the Crab above 35 MeV were made with the high energy gamma ray telescope flown on SAS-2. The detector and technique are described in detail.

Kniffen, D. A.↗