Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Cybersecurity Considerations for Grid-Connected Batteries with Hardware Demonstrations

The share of renewable and distributed energy resources (DERs), like wind turbines, solar photovoltaics and grid-connected batteries, interconnected to the electric grid is rapidly increasing due to reduced costs, rising efficiency, and regulatory requirements aimed at incentivizing a lower-carbon electricity system. These distributed energy resources differ from traditional generation in many ways including the use of many smaller devices connected primarily (but not exclusively) to the distribution network, rather than few larger devices connected to the transmission network. DERs being installed today often include modern communication hardware like cellular modems and WiFi connectivity and, in addition, the inverters used to connect these resources to the grid are gaining increasingly complex capabilities, like providing voltage and frequency support or supporting microgrids. To perform these new functions safely, communications to the device and more complex controls are required. The distributed nature of DER devices combined with their network connectivity and complex controls interfaces present a larger potential attack surface for adversaries looking to create instability in power systems. To address this area of concern, the steps of a cyberattack on DERs have been studied, including the security of industrial protocols, the misuse of the DER interface, and the physical impacts. These different steps have not previously been tied together in practice and not specifically studied for grid-connected storage devices. In this work, we focus on grid-connected batteries. We explore the potential impacts of a cyberattack on a battery to power system stability, to the battery hardware, and on economics for various stakeholders. We then use real hardware to demonstrate end-to-end attack paths exist when security features are disabled or misconfigured. Our experimental focus is on control interface security and protocol security, with the initial assumption that an adversary has gained access to the network to which the device is connected. We provide real examples of the effectiveness of certain defenses. This work can be used to help utilities and other grid-connected battery owners and operators evaluate the severity of different threats and the effectiveness of defense strategies so they can effectively deploy and protect grid-connected storage devices.

25 ENERGY STORAGE↗

A Game Changer: Electrifying Remote Communities by Using Isolated Microgrids

Microgrids, as self-contained entities, are of increasing interest in modern electric grids. Microgrids provide a sustainable solution to aggregate distributed energy resources (DERs) [e.g., photovoltaics (PVs), wind turbines], energy storage, and loads in a localized manner, especially in distribution systems. As a controllable unit, a microgrid can manage and balance the source and load power inside it to ensure stable and reliable operation. Moreover, through coordination with upper-level control systems, it can be dispatched and respond to the control commands issued by the central controller in the distribution system-in other words, a system that is effectively a distribution management system (DMS).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AC Resistance Reduction Using Orthogonal Air Gaps in High-Frequency Inductors: Preprint

This paper presents a relatively simple technique to reduce winding losses due to fringing fields in high-frequency inductors. In high-frequency power electronics, ac inductor winding losses are affected by skin and proximity effects, including uneven current distribution due to fringing magnetic fields around airgaps. It is well known how fringing effects can be mitigated using distributed airgaps, at the expense of non-standard core or winding geometry. In planar magnetics, the orthogonal-airgap approach proposed in this paper combines airgaps in core segments parallel with the windings with conventionally placed airgaps in segments perpendicular to the windings. The approach is developed using a 1D analytical framework and validated by 2D finite-element simulations. Analytical guidelines are presented to optimize the airgaps to achieve minimum ac resistance. As a case study, a planar inductor is designed for an 8~kW SiC-based buck converter operating at 250~kHz. It is shown how the orthogonal airgaps result in more than 45\% reduction in ac resistance and substantially reduced inductor losses compared to the design using standard airgaps. The results are verified by loss measurements on an experimental converter prototype.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Efficiency 2-Bladed Utility Wind Turbine Enhanced by CoFlow Jet Active Flow Control

The aerodynamic performance and power output of a high efficiency Co-Flow Jet (CFJ) 2-bladed Wind Turbine is studied in this paper. CFJ is a Zero-Net-Mass-Flux (ZNMF) active flow control method that dramatically increases airfoil lift coefficient and suppresses flow separation at a low energy expenditure. The 3D Reynolds Averaged Navier-Stokes (RANS) equations with one-equation Spalart-Allmaras (SA) turbulence model are solved to simulate the 3D flows of the wind turbines. The CFJ-Wind Turbine in this paper is modified from the NREL 3-bladed 3.4 MW reference wind turbine with the same RPM, blade length, distribution of chord, twist, and bending. The CFJ 2-bladed wind turbine utilizes the CFJ-NACA 64 series airfoils at most of the blade span from 31.88\% to the tip. The CFJ injection and suction slots are implemented along the full blade span to enhance the effectiveness and power output. The study shows that the 2-bladed CFJ turbine significantly increases power output compared with the 3-bladed baseline turbine at all wind speeds by 15.8\% at the wind speed of 9.8 m/s and by 25.9\% at 4 m/s respectively. The efficiency enhancement is substantially more at the low wind speed than at high wind speed. This would be very beneficial to increase the annual power output or capacity factor as wind turbines work at the speeds lower than the rated speed for most of the time. The results show that the flow field around the blade surface presents a significant enhanced suction peak near the blade leading edge, which results in a very high tangential force and thus increased wind turbine net power coefficient. Consistent with the previous study for the small NREL Phase VI research wind turbine, this paper demonstrates that CFJ 2-bladed wind turbine is an effective technology to extract more power from the wind at all speeds. This study is just an initial effort to demonstrate the advantage of the CFJ blade with no design optimization. It is believed that there is more potential to further enhance the efficiency improvement.

active flow control↗

An Energy Service Interface for Distributed Energy Resources

Renewable energy resources, particularly wind and solar photovoltaic, are becoming significant contributors to electric power generation. These re-sources will contribute towards achieving sustainable electric power systems. However, renewable resources will dramatically increase the demand for flexible power system operations. This paper proposes an energy service interface that will allow aggregated distributed energy resources, such as residential loads and inverter-based systems, to participate in NERC-defined smart energy reliability services. Such cyber-physical systems will increase system flexibility by ensuring match between energy supply and energy demand.Aggregation and coordinated dispatch of millions of distributed energy resources will require development of large-scale computing networks. Several smart grid interface-enabling technologies, including IEEE 2030.5, Common Smart Inverter Profile, SunSpec Modbus, and CTA 2045, are discussed. Residential loads are categorized by their static and dynamic energy characteristics to identify services in which they can participate. The business model for the energy services interface as well as probabilistic modeling for resource estimation are highlighted as future considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multiple Flux-tube Solar Wind Model

We present a new model, MULTI-VP, which computes the three-dimensional structure of the solar wind and includes the chromosphere, the transition region, and the corona and low heliosphere. MULTI-VP calculates a large ensemble of wind profiles flowing along open magnetic field lines that sample the entire three-dimensional atmosphere or, alternatively, a given region of interest. The radial domain starts from the photosphere and typically extends to about 30 R{sub ⊙}. The elementary uni-dimensional wind solutions are based on a mature numerical scheme that was adapted in order to accept any flux-tube geometry. We discuss here the first results obtained with this model. We use Potential Field Source-surface extrapolations of magnetograms from the Wilcox Solar Observatory to determine the structure of the background magnetic field. Our results support the hypothesis that the geometry of the magnetic flux-tubes in the lower corona controls the distribution of slow and fast wind flows. The inverse correlation between density and speed far away from the Sun is a global effect resulting from small readjustments of the flux-tube cross-sections in the high corona (necessary to achieve global pressure balance and a uniform open flux distribution). In comparison to current global MHD models, MULTI-VP performs much faster and does not suffer from spurious cross-field diffusion effects. We show that MULTI-VP has the capability to predict correctly the dynamical and thermal properties of the background solar wind (wind speed, density, temperature, magnetic field amplitude, and other derived quantities) and to approach real-time operation requirements.

79 ASTRONOMY AND ASTROPHYSICS↗

Regional distribution of large blowdown patches across Amazonia in 2005 caused by a single convective squall line: Distribution of Amazonia Blowdown Damage

In mid-January 2005 a convective squall line traversed 4.5 × 10 6 km 2 of Amazonia from southwest to northeast. As seen in Landsat images, this atypical convective storm left blowdown imprints with diffuse geometry, unlike the fan-shaped wind disturbance of much more frequent east-to-west propagating squall lines. Previous work reported 0.2% of the forest area damaged by this one relatively rare event within one Landsat image and assumed similar disturbance across the entire traverse. Here, we mapped convective wind damage impact to the region in 2005 by identifying large-scale (>4 ha) blowdown imprints in 30 Landsat images. The diffuse-type imprints associated with this single squall line contributed up to 60–72% of total 2005 wind-disturbed area detected across the region, but damage was highly concentrated in central Amazonia. Consequently, the distribution of large wind damage patches in 2005 across Amazonia was very different from long-term average. In conclusion, tegional distribution of wind-driven tree mortality for smaller patch sizes remains unknown.

54 ENVIRONMENTAL SCIENCES↗

Wind Power Forecasting Error Frequency Analyses for Operational Power System Studies: Preprint

The examination of wind power forecasting errors is crucial for optimal unit commitment and economic dispatch of power systems with significant wind power penetrations. This scheduling process includes both renewable and nonrenewable generators, and the incorporation of wind power forecasts will become increasingly important as wind fleets constitute a larger portion of generation portfolios. This research considers the Western Wind and Solar Integration Study database of wind power forecasts and numerical actualizations. This database comprises more than 30,000 locations spread over the western United States, with a total wind power capacity of 960 GW. Error analyses for individual sites and for specific balancing areas are performed using the database, quantifying the fit to theoretical distributions through goodness-of-fit metrics. Insights into wind-power forecasting error distributions are established for various levels of temporal and spatial resolution, contrasts made among the frequency distribution alternatives, and recommendations put forth for harnessing the results. Empirical data are used to produce more realistic site-level forecasts than previously employed, such that higher resolution operational studies are possible. This research feeds into a larger work of renewable integration through the links wind power forecasting has with various operational issues, such as stochastic unit commitment and flexible reserve level determination.

17 WIND ENERGY↗

Inverse Biot–Savart Optimization for Superconducting Accelerator Magnets

Superconducting (SC) magnets for accelerator concepts are often synthesized by numerically optimizing magnetic field waveforms, a process that requires a subsequent solution of a constrained inverse problem to identify suitable SC magnet windings. When the desired field distribution is intuitive, the inverse process is facilitated by seeding preconceived coil distributions into design optimization methods for refinement. With more complex magnetic field distributions, an initial design may be unknown, and topology optimization tools are required to synthesize current distributions without a priori guidance from a subject matter expert. In this work, we develop a constrained inverse Biot-Savart topology optimization methodology that synthesizes optimal distributions of current density in racetrack-like SC coils. The problem structure is exploited through a computationally efficient quadratic programming formulation, and the method is applied to recently published magnetic field waveforms for a recirculating proton phase shifter, a proton therapy gantry, and dipole magnets with sharp field transitions. The method and results herein identify novel winding configurations that can help magnet designers bring accelerator concepts to fruition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Life Sciences Laboratory 2 Fan Exhaust Mixing Study

An SF 6 tracer release was performed in the LSL-II ventilation stack over the weekend of March 5, 2016. The primary purpose of this study was to experimentally determine the gaseous concentration of material from a fume hood to the fan outlet, as well as at typical worker locations, to gain an understanding of potential worker exposures impacts. Five different fan operating configurations were utilized to ensure that the full spectrum of historical operating configurations was addressed. Some summary points from this study include: •Relatively high concentrations were observed within the stack area. –Between 50 and 100% of the exhaust concentration may be observed within the stack. •Background concentrations were observed outside the stack area. –Workers outside the stack itself, but on the roof, are unlikely to be impacted by the exhaust. •Elevated concentrations on the order of 25% of the exhaust concentrations were observed within the Penthouse. •Transport time from a laboratory fume hood to the exhaust fan is within one to two minutes. •Penthouse concentrations climb from background levels to steady state over 15+ minutes. •Wind speed and wind direction did not play a significant role in the test outcomes. –A slight bias in the concentration distribution may be discernable based on wind speed and direction. •When both fans are operating, material from fume hoods on the east side preferentially flow through the east fan, while material from fume hoods on the west side preferentially flow through the west fan. This effectively doubles the concentration at that fan. This mixing study will inform other study components to develop a more complete picture of the worker potential exposure from LSL-II Rooftop activities. Estimating the mean concentration in the stack from chemical inventories and fume hood emissions for both current and historical laboratory activities is a separate effort. These estimates of mean ventilation concentrations will utilize this mixing study to estimate the potential exposure to workers working in and around the LSL-II stack.

42 ENGINEERING↗

Energy optimization for a wind DFIG with flywheel energy storage

The type of distributed generation unit that is the subject of this paper relates to renewable energy sources, especially wind power. The wind generator used is based on a double fed induction Generator (DFIG). The stator of the DFIG is connected directly to the network and the rotor is connected to the network through the power converter with three levels. The objective of this work is to study the association a Flywheel Energy Storage System (FESS) in wind generator. This system is used to improve the quality of electricity provided by wind generator. It is composed of a flywheel; an induction machine (IM) and a power electronic converter. A maximum power tracking technique « Maximum Power Point Tracking » (MPPT) and a strategy for controlling the pitch angle is presented. The model of the complete system is developed in Matlab/Simulink environment / to analyze the results from simulation the integration of wind chain to networks.

17 WIND ENERGY↗

Waiting-time distributions of magnetic discontinuities: Clustering or Poisson process?

Using solar wind data from the Advanced Composition Explorer spacecraft, with the support of Hall magnetohydrodynamic simulations, the waiting-time distributions of magnetic discontinuities have been analyzed. A possible phenomenon of clusterization of these discontinuities is studied in detail. We perform a local Poisson's analysis in order to establish if these intermittent events are randomly distributed or not. Possible implications about the nature of solar wind discontinuities are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Digital Twin for Hydrogen Dispersion and Safety Assessment in an Electrolyzer Based Hydrogen Production Facility

Digital twin models are virtual representations of physical systems that use real-time data to simulate and optimize performance. This study presents the development and initial implementation of a digital twin (DT) for the electrolyzer-based hydrogen production facility at NREL's Advanced Research on Integrated Energy Systems (ARIES), focused on enhancing safety and optimizing sensor placement through physics-based simulations and metadata integration. The DT incorporates detailed facility-specific information, including component layout, leak locations, and controlled release parameters, to model hydrogen dispersion under varying environmental conditions. Using steady-state computational fluid dynamics (CFD) simulations informed by real meteorological data, such as wind speed, direction, and vertical wind profiles, the DT enables visualization of hydrogen plume behavior and spatial concentration distributions. Comparative analysis between high and low wind speed scenarios illustrates the significant influence of wind dynamics on plume shape and extent, with horizontal momentum dominating dispersion at higher speeds, while buoyancy effects become more prominent under low wind conditions. These simulations generate a rich dataset embedded within the DT, allowing users to assess potential leak outcomes and identify optimal sensor locations based on concentration thresholds. The model supports scenario-based analysis to guide safety strategies and equipment deployment for open-area hydrogen infrastructure. The digital twin thus serves as a dynamic platform for virtual prototyping, providing predictive insight into hydrogen behavior and enhancing risk-informed decision-making. This initial phase establishes a validated foundation for future integration of transient, uncontrolled leak scenarios and real-time sensor feedback, positioning the DT as a critical tool for safety design, operational planning, and adaptive monitoring in hydrogen systems. Overall, the approach demonstrates the value of combining environmental data with digital simulations to inform safer and more efficient deployment of hydrogen technologies.

08 HYDROGEN↗

Development of a Digital Twin for Hydrogen Dispersion and Safety Assessment in an Electrolyzer-Based Hydrogen Production Facility: Preprint

Digital twin models are virtual representations of physical systems that use real-time data to simulate and optimize performance. This study presents the development and initial implementation of a digital twin (DT) for the electrolyzer-based hydrogen production facility at the National Renewable Energy Laboratory (NREL)'s Advanced Research on Integrated Energy Systems (ARIES), focused on enhancing safety and optimizing sensor placement through physics-based simulations and metadata integration. The DT incorporates detailed facility-specific information, including component layout, leak locations, and controlled release parameters, to model hydrogen dispersion under varying environmental conditions. Using steady-state computational fluid dynamics (CFD) simulations informed by real meteorological data, such as wind speed, direction, and vertical wind profiles, the DT enables visualization of hydrogen plume behavior and spatial concentration distributions. Comparative analysis between high and low wind speed scenarios illustrates the significant influence of wind dynamics on plume shape and extent, with horizontal momentum dominating dispersion at higher speeds, while buoyancy effects become more prominent under low wind conditions. These simulations generate a rich dataset embedded within the DT, allowing users to assess potential leak outcomes and identify optimal sensor locations based on concentration thresholds. The model supports scenario-based analysis to guide safety strategies and equipment deployment for open-area hydrogen infrastructure. The digital twin thus serves as a dynamic platform for virtual prototyping, providing predictive insight into hydrogen behavior and enhancing risk-informed decision-making. This initial phase establishes a validated foundation for future integration of transient, uncontrolled leak scenarios and real-time sensor feedback, positioning the DT as a critical tool for safety design, operational planning, and adaptive monitoring in hydrogen systems. Overall, the approach demonstrates the value of combining environmental data with digital simulations to inform safer and more efficient deployment of hydrogen technologies.

08 HYDROGEN↗

Emissions of nitrogen oxides from US urban areas: estimation from Ozone Monitoring Instrument retrievals for 2005–2014

Satellite remote sensing of tropospheric nitrogen dioxide (NO 2 ) can provide valuable information for estimating surface nitrogen oxides (NO x ) emissions. Using an exponentially modified Gaussian (EMG) method and taking into account the effect of wind on observed NO 2 distributions, we estimate 3-year moving-average emissions of summertime NO x from 35 US (United States) urban areas directly from NO 2 retrievals of the Ozone Monitoring Instrument (OMI) during 2005–2014. Following conclusions of previous studies that the EMG method provides robust and accurate emission estimates under strong-wind conditions, we derive top-down NO x emissions from each urban area by applying the EMG method to OMI data with wind speeds greater than 3–5 m s -1 . Meanwhile, we find that OMI NO 2 observations under weak-wind conditions (i.e., < 3 m s &minus;1 ) are qualitatively better correlated to the surface NO x source strength in comparison to all-wind OMI maps; therefore, we use them to calculate the satellite-observed NO 2 burdens of urban areas and compare with NO x emission estimates. The EMG results show that OMI-derived NO x emissions are highly correlated ( R > 0.93) with weak-wind OMI NO 2 burdens as well as with bottom-up NO x emission estimates over 35 urban areas, implying a linear response of the OMI observations to surface emissions under weak-wind conditions. The simultaneous EMG-obtained effective NO 2 lifetimes (~ 3.5 ± 1.3 h), however, are biased low in comparison to the summertime NO 2 chemical lifetimes. In general, isolated urban areas with NO x emission intensities greater than ~ 2 Mg h -1 produce statistically significant weak-wind signals in 3-year average OMI data. From 2005 to 2014, we estimate that total OMI-derived NO x emissions over all selected US urban areas decreased by 49 %, consistent with reductions of 43, 47, 49, and 44 % in the total bottom-up NO x emissions, the sum of weak-wind OMI NO 2 columns, the total weak-wind OMI NO 2 burdens, and the averaged NO 2 concentrations, respectively, reflecting the success of NO x control programs for both mobile sources and power plants. The decrease rates of these NO x -related quantities are found to be faster (i.e., -6.8 to -9.3 % yr &minus;1 ) before 2010 and slower (i.e., -3.4 to -4.9 % yr &minus;1 ) after 2010. For individual urban areas, we calculate the R values of pair-wise trends among the OMI-derived and bottom-up NO x emissions, the weak-wind OMI NO 2 burdens, and ground-based NO 2 measurements, and high correlations are found for all urban areas (median R = 0.8), particularly large ones ( R up to 0.97). The results of the current work indicate that using the EMG method and considering the wind effect, the OMI data allow for the estimation of NO x emissions from urban areas and the direct constraint of emission trends with reasonable accuracy.

54 ENVIRONMENTAL SCIENCES↗

Emissions of nitrogen oxides from US urban areas: estimation from Ozone Monitoring Instrument retrievals for 2005-2014

Satellite remote sensing of tropospheric nitrogen dioxide (NO 2 ) can provide valuable information for estimating surface nitrogen oxides (NO x ) emissions. Using an exponentially-modified Gaussian (EMG) method and taking into account the effect of wind on observed NO 2 distributions, we estimate three-year moving-average emissions of summertime NO x from 35 US urban areas directly from NO 2 retrievals of the Ozone Monitoring Instrument (OMI) during 2005–2014. Following the conclusions of previous studies that the EMG method provides robust and accurate emission estimates under strong-wind conditions, we derive top-down NO x emissions from each urban area by applying the EMG method to OMI data with wind speeds greater than 3–5 m s -1 . Meanwhile, we find that OMI NO 2 observations under weak-wind conditions (i.e., < 3 m s -1 ) are qualitatively better correlated with the surface NO x source strength in comparison to all-wind OMI maps; and therefore we use them to calculate the satellite-observed NO 2 burdens of urban areas and compare with NO x emission estimates. The EMG results show that OMI-derived NO x emissions are highly correlated ( R > 0.93) with weak-wind OMI NO 2 burdens as well as bottom-up NO x emission estimates over 35 urban areas, implying a linear response of the OMI observations to surface emissions under weak-wind conditions. The simultaneous, EMG-obtained, effective NO 2 lifetimes (~3.5 ± 1.3 h), however, are biased low in comparison to the summertime NO 2 chemical lifetimes. In general, isolated urban areas with NO x emission intensities greater than ~ 2 Mg h -1 produce statistically significant weak-wind signals in three-year average OMI data. From 2005 to 2014, we estimate that total OMI-derived NO x emissions over all selected US urban areas decreased by 49%, consistent with reductions of 43, 47, 49, and 44% in the total bottom-up NO x emissions, the sum of weak-wind OMI NO 2 columns, the total weak-wind OMI NO 2 burdens, and the averaged NO 2 concentrations, respectively, reflecting the success of NO x control programs for both mobile sources and power plants. The decrease rates of these NO x -related quantities are found to be faster (i.e., -6.8 to -9.3% yr -1 ) before 2010 and slower (i.e., -3.4 to -4.9% yr -1 ) after 2010. For individual urban areas, we calculate the R values of pair-wise trends among the OMI-derived and bottom-up NO x emissions, the weak-wind OMI NO 2 burdens, and ground-based NO 2 measurements; and high correlations are found for all urban areas (median R = 0.8), particularly large ones ( R up to 0.97). The results of the current work indicate that using the EMG method and considering the wind effect, the OMI data allow for the estimation of NO x emissions from urban areas and the direct constraint of emission trends with reasonable accuracy.

54 ENVIRONMENTAL SCIENCES↗

PRESSURE OF THE PROTON PLASMA IN THE INNER HELIOSHEATH

We develop a physical model to study the pressure of the source proton plasma in the inner heliosheath based on the IBEX Energetic Neutral Atom (ENA) spectra. A multiple linear regression technique is used to parameterize the proton distribution function, by connecting the observed ENA flux spectrum from IBEX-Hi with the power-law of the model proton distribution. We calculate the partial pressure over the measured energy range, using (1) a non-parametric method by integrating the observed ENA flux, and (2) a parametric method by integrating the modeled distribution of protons in the inner heliosheath. The two sky maps of the parametric and non-parametric partial pressures are nearly identical, owing to their power-law distributions at high energies; the kappa distribution is such a function that can be reduced to a power-law in the IBEX-Hi energy range. The slight differences between the two partial pressures may indicate protons that are not described by the kappa distribution, and instead, involve newer or 'immature' (spherical shell) pick-up proton distributions. Ultimately, however, these become incorporated with the solar wind into one single proton population described by a kappa distribution. Moreover, we derive analytically (1) the ENA flux spectra, which suggests that this flux maximizes at {approx}30 eV, and (2) the differential pressure, which provides estimates of the partial pressures outside of those measured by IBEX-Hi. Under the assumptions of the modeled ENA spectra, the Ribbon emissions appear to be primarily limited to the energy ranges of IBEX-Lo and IBEX-Hi.

79 ASTRONOMY AND ASTROPHYSICS↗

Probabilistic Modeling of Climate Change Impacts on Renewable Energy and Storage Requirements for NM's Energy Transition Act (SAND Report)

This report provides a study of the potential impacts of climate change on intermittent renewable energy resources, battery storage, and resource adequacy in Public Service Company of New Mexico’s Integrated Resource Plan for 2020 – 2040. Climate change models and available data were first evaluated to determine uncertainty and potential changes in solar irradiance, temperature, and wind speed in NM in the coming decades. These changes were then implemented in solar and wind energy models to determine impacts on renewable energy resources in NM. Results for the extreme climate-change scenario show that the projected wind power may decrease by ~13% due to projected decreases in wind speed. Projected solar power may decrease by ~4% due to decreases in irradiance and increases in temperature in NM. Uncertainty in these climate-induced changes in wind and solar resources was accommodated in probabilistic models assuming uniform distributions in the annual reductions in solar and wind resources. Uncertainty in battery storage performance was also evaluated based on increased temperature, capacity fade, and degradation in round-trip efficiency. The hourly energy balance was determined throughout the year given uncertainties in the renewable energy resources and energy storage. The loss of load expectation (LOLE) was evaluated for the 2040 No New Combustion portfolio and found to increase from 0 days/year to a median value of ~2 days/year due to potential reductions in renewable energy resources and battery storage performance and capacity. A rank-regression analyses revealed that battery round-trip efficiency was the most significant parameter that impacted LOLE, followed by solar resource, wind resource, and battery fade. An increase in battery storage capacity to ~25,000 – 30,000 MWh from a baseline value of ~14,000 MWh was required to reduce the median value of LOLE to ~0.2 days/year with consideration of potential climate impacts and battery degradation.

54 ENVIRONMENTAL SCIENCES↗