Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distance Learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

PRIMO – The Oil & Gas Well Plugging Optimizer

This work presents PRIMO’s main capabilities and introduces the PRIMO web application, an intuitive user interface that leverages our sophisticated mathematical optimization model to rigorously optimize P&A priorities and plugging campaign efficiency. The web app simplifies user interaction, provides a powerful data management framework, and supports a broad user base (e.g., state agencies, well owners/operators, and plugging companies) to use PRIMO for decision-making. Specifically, we provide a demonstration of how to input the information on candidate wells, plugging campaign budget, user-defined priority and efficiency criteria to PRIMO. A real-world case study that consists of 1411 oil and gas wells and impact and efficiency priorities (e.g., well age, well proximity to schools/hospitals, well accessibility, distance between wells in projects) is presented to showcase PRIMO’s core capabilities: (i) ranking a candidate well population based on priorities, (ii) recommending high-impact and high-efficiency P&A projects, and (iii) assigning impact and efficiency scores to projects allowing for rigorous quantitative comparison among them.

02 PETROLEUM↗

Sound at Scale: Characterizing Impacts of Noise Ordinances on the Onshore Wind Energy Technical Potential for the United States

Recent surveys have documented the rapid rise of sound ordinances across state and county jurisdictions, which has become crucial for wind energy siting. However, the lack of information on ordinances and computational challenges in turbine sound modeling create uncertainties regarding how evolving policies may affect resource potential and clean energy objectives. Therefore, we develop an approach to evaluate wind turbine sound profiles at millions of locations across the U.S. and translate them into setback distances for every residential structure. Compared to a baseline reference scenario, we find a 7% reduction in the national wind energy capacity potential when accounting for counties with existing sound ordinances. Additionally, when expanding the surveyed sound ordinances nationwide, we observe a potential loss of 53% of the national wind capacity under the most stringent ordinances, with a disproportionate share of this lost capacity coming from high-quality and low-cost wind resource. This work reveals that neglecting sound ordinances results in a significant overestimation of wind resource potential and highlights the important trade-offs between increased wind energy deployment to meet target decarbonization goals and the social/environmental impacts of this deployment that must be considered.

aeroacoustics↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

The Application of Artificial Intelligence Deep Learning to Visually Identify Micrometeoroid and Orbital Debris Impacts

Recent advances in Artificial Intelligence (AI) are changing the World. Novel approaches to training AI systems have led to dramatic reductions in the amount of time required. Training an AI system could take years and teams of people using traditional methods, but with the advancements of Deep Learning (DL) models this training can now be accomplished by an individual in a matter of minutes. The development of “fast AI” libraries has delivered AI to essentially everyone. Democratization of AI power has inspired many to revisit past problems that will benefit from DL approaches. For example, the application of AI has improved detection of breast cancer by 20% compared to traditional detection methods. Computer vision and machine learning are being used to identify soil deficiencies and provide planting recommendations to farmers. Success stories like these and many others have provided inspiration to see if AI can help improve one of our needed capabilities – that of visually identifying micrometeoroid and orbital debris (MMOD) impact damage to spacecraft from images of the spacecraft exterior. The need to visually locate and characterize spacecraft MMOD impact damage has been present since the early days of space travel. This is often done by either having a crew member take photographs of the spacecraft through a window using a hand-held camera or ground personnel directing externally-mounted cameras. The photographs are then transmitted back to Earth for visual analysis. This method of MMOD damage inspection works well and has been used on various spacecraft including the Space Shuttle and the International Space Station (ISS). One of the issues with the current method that we believe AI could improve is the speed and possibly the accuracy in identifying MMOD impacts. Note that detecting MMOD impacts in images can be very difficult. The visual appearance of an MMOD impact can change dramatically with lighting conditions, size of impact, depth of penetration, material types, surface waviness, fabric coverings, camera & lens, distance to surface, spacecraft orientation, analyst experience, and many other factors. Currently, this takes a team of highly-experienced specialists in both the fields of Image Analysis and MMOD impacts. This paper documents our initial research in training an AI DL model using the fast-AI library to identify actual and simulated MMOD impacts and perforations into exposed flat surfaces. While we recognize that this initial goal seems modest, it must be noted that what we have done would have taken teams of individuals and years of training just ten years ago. Our long-term goal is to add complexity and use-cases to the DL model being trained to expand the capabilities of this model so that it can be used to identify MMOD impacts on all types of spacecraft surfaces.

Cameron M Collins↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Marine Mammal Behavioral Response to Tidal Turbine Sound

The sound emitted by tidal turbines overlaps with the generalized hearing ranges for marine mammals and may, consequently, affect marine mammal behavior. Because of the strong environmental protections for marine mammals, these effects are of interest to resource agencies and project developers. The primary goal of this project is to improve the understanding of how sound emitted by tidal turbines may affect marine mammal behavior, with the intent that such understanding may allow this environmental risk to be “retired” for initial demonstrations and arrays. A secondary project goal is to evaluate the efficacy of marine mammal observations from a shore-based vantage point as a method to detect change as a consequence of marine energy stressors. Three, two-week trials were conducted across spring, summer and autumn of 2017 during which vantage-point observations of marine mammals were made from land. We refer to these two-week periods as ‘trials’ as they represent different periods of field data collection. These observations consisted of scan samples every 10 minutes with a set of binoculars and a DSLR camera. When pinnipeds were sighted, still images were taken. When harbor porpoise were sighted, focal follows using video were initiated. These data were later analyzed to estimate the location of animals sighted using photogrammetric techniques. For approximately half of each trial period, a boat was moored in the study area from which an underwater projector was used to play back tidal turbine sounds at a broadband source level of 158 dB re µPa @ 1 m. The other half of each trial period had no playbacks and was used as a control period. During the control and playback periods, ancillary data were collected in the study area near the sea floor (ambient noise, tidal velocity, and porpoise clicks) while weather and vessel tracks were recorded near the vantage-point station. Harbor seals did not show a significant response to the simulated turbine noise, nor did harbor porpoise change their closest point of approach or change the direction/deviation of the paths during periods when the playback was occurring. While porpoise sightings and porpoise acoustic detections were significantly reduced during playback periods in the first two trials, the number of detections during the playback periods increased during the third trial. Similarly, the calculated distance from porpoises to the playback location suggests that harbor porpoises avoided an area around the playback location of approximately 300 m during Trial 1, which decreased to approximately 100 m in Trial 2, and disappeared in Trial 3. This could be an indication of habituation or increased tolerance, either to the playback sound or the vessel presence. Our finding of no significant effect of turbine noise on harbor seals contrast with the findings in a previous study by Hastie et al. (2017) conducted in United Kingdom waters. However, due to substantive differences in source levels and propagation loss, seals in our study would need to have been within 10 m of the playback location to experience similar received levels to those in the Hastie et al. study. Consequently, the two studies may actually be in agreement. Our findings of significant effect of turbine noise on harbor porpoise are in line with previous studies suggesting the harbor porpoise are sensitive to noise. However, we note that, due to cost and logistical constraints, the playback vessel was only mooring during the playback periods. Consequently, we cannot definitively ascribe the changes in porpoise behavior to the simulated turbine noise, playback vessel presence, or a combination of both factors. This methodological limitation and other lessons learned are discussed to benefit future studies that explore the effects of acoustic stressors on marine mammals.

16 TIDAL AND WAVE POWER↗

Overview of the Fiber System for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI's success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ~f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

79 ASTRONOMY AND ASTROPHYSICS↗

Monitoring the Intrinsic Absorption Complex Toward RX J1230.8+115

There is a very prominent intrinsic absorption complex in the spectrum of the quasar RX J1230.8+115. It was diagnosed as intrinsic due to partial covering of the quasar by the absorber, which can only happen for material very near to the quasar. Measuring a variability timescale for the absorption would allow us to place a more stringent constraint on the distance of the absorber from the central engine. Furthermore, understanding the variability and covering factors in different transitions can help to identify if it is due to changes in the ionizing source or transverse motion of the absorber. The OVI doublet is covered in the FUSE wavelength range. Unfortunately, our initial target, RX J1230.8+0115 could not be observed due to the failure of the first reaction wheel. We determined that another target, H 1821+643, could be observed and would satisfy similar science goals, understanding intrinsic narrow absorption line systems. Our specific goal for that target was to search for Ne VI11 absorption from the associated absorber. This observation was attempted, but the counts in the Sic channel, where the absorption was expected to lie, were too low to satisfy our science goal. This was, at least in part, due to a misalignment of the SiC mirrors. Because of this problem, more time was awarded. However, even the extra time was too little. It appears that the quasar may be too faint to properly align all the mirrors. So with disappointment, I report that we were not able to accomplish our science goals for this program. The funds were used to support my work with a graduate student, Jie Ding, to evaluate possible replacement targets once we learned that Rx J1230.8+115 would not be observable. We considered the intrinsic NAL candidates that we could find through a partial coverage analysis of doublets in the STIS E140M and E230M quasar spectra taken from the HST archive. We then checked the flux in the FUSE wavelength range, and in most cases of interest it was found to be too low to satisfy our S/N requirement in the exposure time we had been awarded. We decided that H1821+643 was the best choice for this project, even though the associated absorber we would be studying might in fact originate in the cluster with the quasar and not in intrinsic gas. Part of the appeal of the target, was in fact the opportunity to consider this issue. Please do not hesitate to contact me if more detail is needed for this report. I found it difficult to write a satisfying report under the circumstance and am uncertain if I've provided the proper level of information.

Charlton, Jane↗

NENCI-2021. I. A large benchmark database of non-equilibrium non-covalent interactions emphasizing close intermolecular contacts

In this work, we present NENCI-2021, a benchmark database of ~8000 Non-Equilibirum Non-Covalent Interaction energies for a large and diverse selection of intermolecular complexes of biological and chemical relevance. To meet the growing demand for large and high-quality quantum mechanical data in the chemical sciences, NENCI-2021 starts with the 101 molecular dimers in the widely used S66 and S101 databases and extends the scope of these works by (i) including 40 cation–π and anion–π complexes, a fundamentally important class of non-covalent interactions that are found throughout nature and pose a substantial challenge to theory, and (ii) systematically sampling all 141 intermolecular potential energy surfaces (PESs) by simultaneously varying the intermolecular distance and intermolecular angle in each dimer. Designed with an emphasis on close contacts, the complexes in NENCI-2021 were generated by sampling seven intermolecular distances along each PES (ranging from 0.7× to 1.1× the equilibrium separation) and nine intermolecular angles per distance (five for each ion–π complex), yielding an extensive database of 7763 benchmark intermolecular interaction energies (E int ) obtained at the coupled-cluster with singles, doubles, and perturbative triples/complete basis set [CCSD(T)/CBS] level of theory. The E int values in NENCI-2021 span a total of 225.3 kcal/mol, ranging from -38.5 to +186.8 kcal/mol, with a mean (median) E int value of -1.06 kcal/mol (-2.39 kcal/mol). In addition, a wide range of intermolecular atom-pair distances are also present in NENCI-2021, where close intermolecular contacts involving atoms that are located within the so-called van der Waals envelope are prevalent—these interactions, in particular, pose an enormous challenge for molecular modeling and are observed in many important chemical and biological systems. A detailed symmetry-adapted perturbation theory (SAPT)- based energy decomposition analysis also confirms the diverse and comprehensive nature of the intermolecular binding motifs present in NENCI-2021, which now includes a significant number of primarily induction-bound dimers (e.g., cation–π complexes). NENCI-2021 thus spans all regions of the SAPT ternary diagram, thereby warranting a new four-category classification scheme that includes complexes primarily bound by electrostatics (3499), induction (700), dispersion (1372), or mixtures thereof (2192). A critical error analysis performed on a representative set of intermolecular complexes in NENCI-2021 demonstrates that the E int values provided herein have an average error of ±0.1 kcal/mol, even for complexes with strongly repulsive E int values, and maximum errors of ±0.2–0.3 kcal/mol (i.e., ~±1.0 kJ/mol) for the most challenging cases. For these reasons, we expect that NENCI-2021 will play an important role in the testing, training, and development of next-generation classical and polarizable force fields, density functional theory approximations, wavefunction theory methods, and machine learning based intra- and inter-molecular potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Nature and State of Groundwater Contamination at the Nevada National Security Site: What Have We Learned from Decades of Groundwater Analysis? - 20337

The regulatory framework for remediating radionuclide contamination from underground nuclear testing at the Nevada National Security Site (NNSS) is based on a combination of characterization and modeling studies, monitoring, and institutional controls [1]. Currently, tritium is the largest contributor (∼90%) to the estimated 44.6 million-curie radionuclide inventory resulting from underground testing [2]. Because of its short half-life (12.32 years), its relative contribution reduces below 10% of the total radiologic inventory over the next 120 years as a result of radioactive decay. Although tritium levels are observed well above the Safe Drinking Water Act (SDWA) maximum contaminant levels (MCLs) in groundwater, other radionuclides are well below their MCLs except within the nuclear test near-field (nuclear test cavity and chimney) environment. In fact, most device-derived radionuclides are below their MCL in groundwater even in samples collected from this near-field environment. The distribution of radionuclides following the nuclear detonation greatly influences the availability of potential contaminants for groundwater transport. Tritium is initially distributed in the gas phase, later as tritiated water in steam, and finally as liquid water, and is available to groundwater transport away from the near-field environment. Other radionuclides that are mobile in groundwater are {sup 14}C, {sup 36}Cl, {sup 99}Tc, and {sup 129}I though their radiologic inventory is small when compared to tritium. Many radionuclides (e.g. U, Pu, Am) are incorporated to a significant extent into the melt glass at the bottom of the cavity and are accessible to groundwater primarily through the slow process of glass dissolution. These radionuclides are also adsorbed to the surfaces of the crushed rock within the cavity and chimney which limits their migration in groundwater. Although colloid facilitated transport of radionuclides at the NNSS has been observed [3], radionuclide concentrations decrease with time and migration distances due to desorption and colloid filtration processes. Current studies indicate that radionuclides associated with colloids are unlikely to migrate downgradient from NNSS underground nuclear tests at concentrations above the SDWA MCL [4][5]. The results of over 50 years of sampling, along with an understanding of these post detonation processes, indicate that tritium is the only contaminant of concern downgradient of testing and that even tritium will not exceed its MCL in groundwater after ∼120 years. Although other longer-lived radionuclides may continue to be released slowly from the near-field environment they will likely never reach levels exceeding their MCLs in groundwater downgradient of the NNSS. Groundwater monitoring will continue to verify these observations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated detection and analysis of particle beams in laser-plasma accelerator simulations

Numerical simulations of laser-plasma wakefield (particle) accelerators model the acceleration of electrons trapped in plasma oscillations (wakes) left behind when an intense laser pulse propagates through the plasma. The goal of these simulations is to better understand the process involved in plasma wake generation and how electrons are trapped and accelerated by the wake. Understanding of such accelerators, and their development, offer high accelerating gradients, potentially reducing size and cost of new accelerators. One operating regime of interest is where a trapped subset of electrons loads the wake and forms an isolated group of accelerated particles with low spread in momentum and position, desirable characteristics for many applications. The electrons trapped in the wake may be accelerated to high energies, the plasma gradient in the wake reaching up to a gigaelectronvolt per centimeter. High-energy electron accelerators power intense X-ray radiation to terahertz sources, and are used in many applications including medical radiotherapy and imaging. To extract information from the simulation about the quality of the beam, a typical approach is to examine plots of the entire dataset, visually determining the adequate parameters necessary to select a subset of particles, which is then further analyzed. This procedure requires laborious examination of massive data sets over many time steps using several plots, a routine that is unfeasible for large data collections. Demand for automated analysis is growing along with the volume and size of simulations. Current 2D LWFA simulation datasets are typically between 1GB and 100GB in size, but simulations in 3D are of the order of TBs. The increase in the number of datasets and dataset sizes leads to a need for automatic routines to recognize particle patterns as particle bunches (beam of electrons) for subsequent analysis. Because of the growth in dataset size, the application of machine learning techniques for scientific data mining is increasingly considered. In plasma simulations, Bagherjeiran et al. presented a comprehensive report on applying graph-based techniques for orbit classification. They used the KAM classifier to label points and components in single and multiple orbits. Love et al. conducted an image space analysis of coherent structures in plasma simulations. They used a number of segmentation and region-growing techniques to isolate regions of interest in orbit plots. Both approaches analyzed particle accelerator data, targeting the system dynamics in terms of particle orbits. However, they did not address particle dynamics as a function of time or inspected the behavior of bunches of particles. Ruebel et al. addressed the visual analysis of massive laser wakefield acceleration (LWFA) simulation data using interactive procedures to query the data. Sophisticated visualization tools were provided to inspect the data manually. Ruebel et al. have integrated these tools to the visualization and analysis system VisIt, in addition to utilizing efficient data management based on HDF5, H5Part, and the index/query tool FastBit. In Ruebel et al. proposed automatic beam path analysis using a suite of methods to classify particles in simulation data and to analyze their temporal evolution. To enable researchers to accurately define particle beams, the method computes a set of measures based on the path of particles relative to the distance of the particles to a beam. To achieve good performance, this framework uses an analysis pipeline designed to quickly reduce the amount of data that needs to be considered in the actual path distance computation. As part of this process, region-growing methods are utilized to detect particle bunches at single time steps. Efficient data reduction is essential to enable automated analysis of large data sets as described in the next section, where data reduction methods are steered to the particular requirements of our clustering analysis. Previously, we have described the application of a set of algorithms to automate the data analysis and classification of particle beams in the LWFA simulation data, identifying locations with high density of high energy particles. These algorithms detected high density locations (nodes) in each time step, i.e. maximum points on the particle distribution for only one spatial variable. Each node was correlated to a node in previous or later time steps by linking these nodes according to a pruned minimum spanning tree (PMST). We call the PMST representation 'a lifetime diagram', which is a graphical tool to show temporal information of high dense groups of particles in the longitudinal direction for the time series. Electron bunch compactness was described by another step of the processing, designed to partition each time step, using fuzzy clustering, into a fixed number of clusters.

43 PARTICLE ACCELERATORS↗

Overview of the Instrumentation for the Dark Energy Spectroscopic Instrument

Abstract The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii ] doublet at 8 × 10 −17 erg s −1 cm −2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamics-guided machine learning model for predicting convective boundary layer height and its multi-site applicability

Accurate estimation of convective boundary layer height (CBLH) is vital for weather, climate, and air quality modeling. Machine learning (ML) shows promise in CBLH prediction, but input parameter selection often lacks physical grounding, limiting generalizability. This study introduces a novel ML framework for CBLH prediction, integrating thermodynamic constraints and the diurnal CBLH cycle as an implicit physical guide. Boundary layer growth is modeled as driven by surface heat fluxes and atmospheric heat absorption represented with the low tropospheric stability, using the diurnal cycle as input and output. TPOT and AutoKeras are employed to select optimal models, validated against Doppler lidar-derived CBLH data, achieving an R 2 of 0.84 across untrained years. Comparisons of eddy covariance (ECOR) and energy balance Bowen ratio (EBBR) flux measurements show the same prediction capability. Models trained on the ARM SGP C1 site with ECOR data and tested at E37 and E39 yield R 2 values of 0.79 and 0.81, respectively, demonstrating their adaptability. The ML model trained with all sites' data slightly enhances the performance compared with ML models trained over single-site data. The interquartile range for predicted CBLH is consistently narrower than that for DL-derived CBLH, reflecting lower variability in predicted CBLH compared to DL-derived CBLH, which is influenced by additional factors, which are not well represented with the model inputs. The model's generalizability across multiple sites at the ARM SGP site demonstrates its potential for transfer to greater distances, offering a scalable approach for enhancing boundary layer parameterization in atmospheric models.

Chu, Yufei [Stony Brook Univ., NY (United States)]↗

EI_MS_ML

The unambiguous identification of compounds from their electron ionization mass (EI-MS) spectra remains a significant unsolved problem in the field of metabolomics and analytical chemistry as a whole. Typically EI-MS spectra are compared using various mathematical operations that convert the spectral similarity or differences into a distance-like metric that roughly approximates the similarity of any two spectra. A commonly used metric for this is the cosine similarity metric which has values close to one for very similar spectra and a value of zero for very dissimilar spectra; however, no metric is perfect. Due to the prevalence of structurally-similar compounds such as isomers and the prevalence of certain fragmentation patterns across structurally-dissimilar compounds, the unambiguous assignment of EI-MS spectra compounds remains difficult. Frequently, querying an observed EI-MS spectrum against a large database such as the NIST17 library yields multiple possible assignments requiring the end user to distinguish between multiple high scoring hits, or multiple low scoring hits while keeping in mind that the correct hit may not be in the database at all. Although techniques such as orthogonal information from techniques such as chromatography can greatly aid in unambiguous assignment, this also requires more complicated experimental designs and access to more complicated analytical instrumentation. Substructures can be trivially detected and represented as strings using a previously published technique called node coloring from a known chemical structure. However, for experimentally-derived EI-MS spectra this information must be derived from the spectra itself (i.e., because we do not know what compound it represents). To achieve this, the software uses techniques from the field of machine learning and a large training dataset of EI-MS spectra corresponding to known structures annotated with substructure strings, to build models that can predict the presence of a given chemical substructure from an EI-MS spectrum directly.If these predictions are of high-quality (i.e., are unlikely to be false positives), the presence of one or more predicted substructures can be used to constrain the number of possible hits for a query spectrum. Mathematically, this restriction could be expressed in many forms, but the most straight-forward implementation is to weight the cosine similarity of a query spectrum and a plausible database match with a Tanimoto-like coefficient based on the ratio of the number of substructures predicted to the number of substructures present in the potential database hit. Determining which combination of models best reduces assignment ambiguity will be achieved using a combination of manual curation and optimization techniques such as genetic algorithms. This software will perform all the steps necessary to construct said models from a training dataset and evaluate them using a holdout dataset. Various statistical analyses can be performed to determine if this approach does decrease assignment ambiguity. For example, if this approach works, on average, the rank-order of the correct assignment for the holdout set of EI-MS spectra should decrease and the weighted cosine similarities for most of the possible matches in the database should be better than the unweighted cosine similarities. Furthermore, this same pipeline can be used on real experimental data to generate less ambiguous assignments.

Mitchell, Joshua↗