Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype of ND-LAr, the liquid argon time-projection chamber of the Deep Underground Neutrino Experiment’s Near Detector complex. Both the 2x2 Demonstrator and ND-LAr are modular detectors that will have pixelated charge readouts and inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are located in between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional grid for each track. Voxels that fall into predefined inactive regions are removed to simulate the lack of detector output. The model is trained to infer the topology of the missing track voxels, with the ultimate goal of inferring the missing charge or energy values in these voxels as well. Results indicate that this approach shows promise in prediction of missing track regions with some accuracy.

Utaegbulam, Hilary↗

Signals of New Physics in the Underlying Event

LHC searches for new physics focus on combinations of hard physics objects. In this work we propose a qualitatively different soft signal for new physics at the LHC - the 'anomalous underlying event'. Every hard LHC event will be accompanied by a soft underlying event due to QCD and pile-up effects. Though it is often used for QCD and monte carlo studies, here we propose the incorporation of an underlying event analysis in some searches for new physics. An excess of anomalous underlying events may be a smoking-gun signal for particular new physics scenarios such as 'quirks' or 'hidden valleys' in which large amounts of energy may be emitted by a large multiplicity of soft particles. We discuss possible search strategies for such soft diffuse signals in the tracking system and calorimetry of the LHC experiments. We present a detailed study of the calorimetric signal in a concrete example, a simple quirk model motivated by folded supersymmetry. In these models the production and radiative decay of highly excited quirk bound states leads to an 'antenna pattern' of soft unclustered energy. Using a dedicated simulation of a toy detector and a 'CMB-like' multipole analysis we compare the signal to the expected backgrounds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signals of new physics in the underlying event

LHC searches for new physics focus on combinations of hard physics objects. In this work we propose a qualitatively different soft signal for new physics at the LHC - the 'anomalous underlying event'. Every hard LHC event will be accompanied by a soft underlying event due to QCD and pileup effects. Though it is often used for QCD and Monte Carlo studies, here we propose the incorporation of an underlying event analysis in some searches for new physics. An excess of anomalous underlying events may be a smoking-gun signal for particular new physics scenarios such as 'quirks' or 'hidden valleys' in which large amounts of energy may be emitted by a large multiplicity of soft particles. We discuss possible search strategies for such soft diffuse signals in the tracking system and calorimetry of the LHC experiments. We present a detailed study of the calorimetric signal in a concrete example, a simple quirk model motivated by folded supersymmetry. In these models the production and radiative decay of highly excited quirk bound states leads to an 'antenna pattern' of soft unclustered energy. Using a dedicated simulation of a toy detector and a multipole analysis familiar in cosmic microwave background studies, we compare the signal to the expected backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector Backgrounds at the Higgs Factory Muon Collider: MARS $vs$ FLUKA

Simulations for the 125-GeV Higgs Factory (HF) Muon Collider (MC) have shown large background particle loads on the collider detector. To verify level, source and composition of background calculations were performed using FLUKA and MARS codes for two shielding configurations. After comprehensive tuning of muon beam parameters, geometry setups and scoring procedures, background particle distributions at the detector entrance were simulated and compared. The spatial distributions and energy spectra of background particles obtained by two codes are rather similar. Average numbers of background particles simulated using MARS and FLUKA agree within a factor of two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Characterization of the SPT-3G Camera

The third-generation South Pole Telescope camera is designed to measure the cosmic microwave background across three frequency bands (centered at 95, 150 and 220 GHz) with ~ 16,000 transition-edge sensor (TES) bolometers. Each multichroic array element on a detector wafer has a broadband sinuous antenna that couples power to six TESs, one for each of the three observing bands and both polarizations, via lumped element filters. Ten detector wafers populate the detector array, which is coupled to the sky via a large-aperture optical system. Here we present the frequency band characterization with Fourier transform spectroscopy, measurements of optical time constants, beam properties, and optical and polarization efficiencies of the detector array. The detectors have frequency bands consistent with our simulations and have high average optical efficiency which is 86, 77 and 66% for the 95, 150 and 220 GHz detectors. The time constants of the detectors are mostly between 0.5 and 5 ms. The beam is round with the correct size, and the polarization efficiency is more than 90% for most of the bolometers.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

On-board Radiation Sensor and Low-Altitude Contour Mapping of Radiation Fields using UAS Swarm - 18239

This paper addresses the design of light weight radiation sensors for the small-scale unmanned aerial system (UAS), and its implementation for low-altitude radiation source localization and contour mapping. The compact, high-resolution gamma-ray CZT sensors were integrated to UAS platforms as plug-and-play components using Robot Operation System (ROS). In this work, the UAS swarm consists of three platforms positioned in circular formation. The onboard data analysis provides time and position stamped intensities of gamma-ray peaks for each UAS-based sensor that are used as the input data for the swarm flight control algorithm. Each UAS measures radiation simultaneously for estimating gradient of radiation to compute a bulk heading angle of the swarm for contour mapping, which can provide relatively precise boundary of the safe area for potential human exploration. The UAS radiation sensors allow measurements from just few meters up to hundreds of meters thus filling the gap between land- and helicopter- based platforms. The swarm of UAS has advantages over a single agent based approach in detecting radiative sources and effectively mapping the area. The proposed method can locate sources of radiation as well as mapping the contaminated area for enhancing situation awareness capabilities for first responders. Computer simulation is presented for UAS swarm based source localization and contour mapping in the simulated radiation fields created by the MCNP code. Selected key gradient estimation and contour mapping algorithms are validated experimentally with small scale multicopter UAS in the indoor flight test bed. (authors)

42 ENGINEERING↗

Cosmic Ray Inspection and Passive Tomography for SNM Detection

The Cosmic Ray Inspection and Passive Tomography (CRIPT) project has recently started investigating the detection of illicit Special Nuclear Material in cargo using cosmic ray muon tomography and complementary neutron detectors. We are currently performing simulation studies to help with the design of small scale prototypes. Based on the prototype tests and refined simulations, we will determine whether the muon tracking system for the full scale prototype will be based on drift chambers or extruded scintillator trackers. An analysis of the operations of the Port of Montreal has determined how long muon scan times should take if all or a subset of the cargo is to be screened. As long as the throughput of the muon system(s) is equal to the rate at which containers are unloaded from ships, the impact on port operations would not be great if a muon scanning stage were required for all cargo. We also show preliminary simulation results indicating that excellent separation between Al, Fe and Pb is possible under ideal conditions. The discrimination power is reduced but still significant when realistic momentum resolution measurements are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a diagnostic for energetic laser-Compton produced photon beams

This paper describes the design and simulation of a radiation detector system for diagnostic measurements of photon beams produced by Thomson or Compton Scattering. The photon beam is Compton scattered in a thin passive converter, and the resulting electrons are analyzed using a charge-coupled device-based tracker and classification algorithms. The flux of the scattered electrons is much lower than that of the photon beam and is additionally dispersed. This dispersal enables measurements while avoiding pileup, which is important in order to provide diagnostic information from intense 'shot’ based pulsed systems, such as those being built to leverage laser wakefield accelerators. Simulations indicate that the designed system is capable of resolving beam parameters from a single shot. The fidelity to which various beam parameters can be resolved is presented as are methods that could result in further improvement to diagnostic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-432: Field Size Influence On the Electron and Photon Spectra Within Small MV Field Detectors

Purpose: To investigate the influence of photon field size on the electron and photon fluence spectra in the active volume of small field detectors. Methods: The PENELOPE MC system based usercode PenEasy was used to calculate the material influence on the spectra by scoring the differential fluence in inserts of silicon, carbon, phosphorus and aluminium having 3 mm diameter and height. The spectra were then calculated inside the active volume of eleven detectors (ion chambers and solid-state detectors) whose geometry was simulated with great detail. The inserts/detectors were placed at 10 cm depth in a 30 cm x 30 cm x 30 cm water phantom and irradiated with 2.5 MeV photons and Varian Clinac 6 MV beams of small, medium and large size. Results: For all configurations, photon spectra in the scoring volume were similar to that in a small water volume except for additional characteristic x-ray peaks resulting from the material itself and from the materials surrounding the detectors (i.e. high-Z shielding the silicon). Electron fluence calculated in the inserts were up to 60% larger than in water; the difference increased with material density and decreasing field size. MC-calculated doses were compared to analytically determined collision kerma and restricted cema (cut-off=15keV). For the inserts, with large and medium fields K-col agreed with MC-dose, but K-col overestimated the dose for small fields due to lack of lateral CPE. For the detectors, up to 15% differences between K-col and the MC-dose were found. For all configurations the C-delta and MC-dose agreed within ±2%. Conclusion: The most relevant findings were that shielding affects substantially the photon spectra and material conditions the electron spectra, their field size dependence varying with the geometry configuration. These affect the values of factors entering into relative dosimetry.

60 APPLIED LIFE SCIENCES↗

Searches for New Physics with the ALICE Experiment in pp Collisions

The performance of the ALICE detector in searches for new heavy stable charged particles in pp collisions is discussed in this paper. Gluino R-hadron was chosen as an example of a candidate, and cross sections and kinematic properties were obtained from PYTHIA simulations for various gluino masses (100-500 GeV/c{sup 2}). Detector response simulations for R-hadrons in the TPC acceptance (|eta|<1) were performed for 100 GeV/c{sup 2} R-hadron mass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-471: Simulated External Beam Delivery Errors Detection with a Large Area Ion Chamber Transmission Detector

Purpose: The Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area, linac-mounted ion chamber used to monitor photon fluence during patient treatment. Our previous work evaluated the change of the ion chamber’s response to deviations from static 1×1 cm2 and 10×10 cm2 photon beams and other characteristics integral to use in external beam detection. The aim of this work is to simulate two external beam radiation delivery errors, quantify the detection of simulated errors and evaluate the reduction in patient harm resulting from detection. Methods: Two well documented radiation oncology delivery errors were selected for simulation. The first error was recreated by modifying a wedged whole breast treatment, removing the physical wedge and calculating the planned dose with Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). The second error was recreated by modifying a static-gantry IMRT pharyngeal tonsil plan to be delivered in 3 unmodulated fractions. A radiation oncologist evaluated the dose for simulated errors and predicted morbidity and mortality commiserate with the original reported toxicity, indicating that reported errors were approximately simulated. The ion chamber signal of unmodified treatments was compared to the simulated error signal and evaluated in Pinnacle TPS again with radiation oncologist prediction of simulated patient harm. Results: Previous work established that transmission detector system measurements are stable within 0.5% standard deviation (SD). Errors causing signal change greater than 20 SD (10%) were considered detected. The whole breast and pharyngeal tonsil IMRT simulated error increased signal by 215% and 969%, respectively, indicating error detection after the first fraction and IMRT segment, respectively. Conclusion: The transmission detector system demonstrated utility in detecting clinically significant errors and reducing patient toxicity/harm in simulated external beam delivery. Future work will evaluate detection of other smaller magnitude delivery errors.

60 APPLIED LIFE SCIENCES↗

Refining instrument response functions with 3-D Monte Carlo simulations of differential hard x-ray spectrometers

Three x-ray spectrometers – the hard x-ray detector (HXRD), the bremsstrahlung MeV x-ray spectrometer (BMXS), and the hard x-ray image plate (HXIP) – areused here to estimate hot-electron bremsstrahlung spectrum parameters for inertial confinement fusion experiments on OMEGA. Using 1-D deterministically calculated response functions, they show significantly different estimates of spectrum slope temperature. For all three detectors, 3-D Geant4 Monte Carlo simulations are developed and used to compute instrument response functions. Simulations explain features in raw image-plate data, but only significantly improve systematic errors in predicted detector channel signals for BMXS and do not entirely eliminate the discrepancy between estimates of slope temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FlameNEST: explicit profile likelihoods with the Noble Element Simulation Technique

We present FlameNEST, a framework providing explicit likelihood evaluations in noble element particle detectors using data-driven models from the Noble Element Simulation Technique. FlameNEST provides a way to perform statistical analyses on real data with no dependence on large, computationally expensive Monte Carlo simulations by evaluating the likelihood on an event-by-event basis using analytic probability elements convolved together in a single TensorFlow multiplication. Furthermore, this robust framework creates opportunities for simple inter-collaboration analyses which will be fundamental for the future of experimental dark matter physics.

47 OTHER INSTRUMENTATION↗

Photon detection probability prediction using one-dimensional generative neural network

Abstract Photon detection is important for liquid argon detectors for direct dark matter searches or neutrino property measurements. Precise simulation of photon transport is widely used to understand the probability of photon detection in liquid argon detectors. Traditional photon transport simulation, which tracks every photon using the Geant4 simulation toolkit, is a major computational challenge for kilo-tonne-scale liquid argon detectors and GeV-level energy depositions. In this work, we propose a one-dimensional generative model which efficiently generates features using an O u t e r P r o d u c t -layer. This model bypasses photon transport simulation and predicts the number of photons detected by particular photon detectors at the same level of detail as the Geant4 simulation. The application to simulating photon detection systems in kilo-tonne-scale liquid argon detectors demonstrates this novel generative model is able to reproduce Geant4 simulation with good accuracy and 20 to 50 times faster. This generative model can be used to quickly predict photon detection probability in huge liquid argon detectors like ProtoDUNE or DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpolation of computed gamma-ray detector response functions

Gamma-ray spectra measured by traditional detectors contain features that result from a combination of the effects of detector materials/geometry, the incident gamma-ray energy, and the angle of entry. The features, such as the full-energy photopeak, Compton continuum, annihilation peak, and escape peaks, are governed by simple relationships depending on incident energy and have been known for a long time. Monte Carlo computer simulations of gamma rays interacting with a detector will show these features, and with a resolution function applied, the results should look similar to real measurements. The traditional approach to creating a detector response function requires many separate simulations of monoenergetic gamma rays striking the detector. This paper presents a new approach to developing computed detector response functions. The new approach involves a much smaller number of monoenergetic gamma-ray simulations and uses interpolation to quickly generate the responses of gamma rays that were not simulated. During the interpolation process, the underlying physics equations are used to accurately compute the response of a given energy gamma ray from the small set of simulations. Such work enables accelerated generation of synthetic radiation detector data.

Detector response↗

Simulating SiD Calorimetry: Software Calibration Procedures and Jet Energy Resolution

Simulated calorimeter performance in the SiD detector is examined. The software calibration procedures are described, as well as the perfect pattern recognition PFA reconstruction. Performance of the SiD calorimeters is summarized with jet energy resolutions from calorimetry only, perfect pattern recognition and the SiD PFA algorithm. Presented at LCWS08[1]. Our objective is to simulate the calorimeter performance of the SiD detector, with and without a Particle Flow Algorithm (PFA). Full Geant4 simulations using SLIC[2] and the SiD simplified detector geometry (SiD02) are used. In this geometry, the calorimeters are represented as layered cylinders. The EM calorimeter is Si/W, with 20 layers of 2.5mm W and 10 layers of 5mm W, segmented in 3.5 x 3.5mm{sup 2} cells. The HAD calorimeter is RPC/Fe, with 40 layers of 20mm Fe and a digital readout, segmented in 10 x 10mm{sup 2} cells. The barrel detectors are layered in radius, while the endcap detectors are layered in z(along the beam axis).

43 PARTICLE ACCELERATORS↗

Event Reconstruction Algorithms for the ATLAS Trigger

The ATLAS experiment under construction at CERN is due to begin operation at the end of 2007. The detector will record the results of proton-proton collisions at a center-of-mass energy of 14 TeV. The trigger is a three-tier system designed to identify in real-time potentially interesting events that are then saved for detailed offline analysis. The trigger system will select approximately 200 Hz of potentially interesting events out of the 40 MHz bunch-crossing rate (with 10{sup 9} interactions per second at the nominal luminosity). Algorithms used in the trigger system to identify different event features of interest will be described, as well as their expected performance in terms of selection efficiency, background rejection and computation time per event. The talk will concentrate on recent improvements and on performance studies, using a very detailed simulation of the ATLAS detector and electronics chain that emulates the raw data as it will appear at the input to the trigger system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗