Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DELIVERY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A Case Study in Proton Pencil-Beam Scanning Delivery

Purpose: We completed an implementation of pencil-beam scanning (PBS), a technology whereby a focused beam of protons, of variable intensity and energy, is scanned over a plane perpendicular to the beam axis and in depth. The aim of radiotherapy is to improve the target to healthy tissue dose differential. We illustrate how PBS achieves this aim in a patient with a bulky tumor. Methods and Materials: Our first deployment of PBS uses 'broad' pencil-beams ranging from 20 to 35 mm (full-width-half-maximum) over the range interval from 32 to 7 g/cm{sup 2}. Such beam-brushes offer a unique opportunity for treating bulky tumors. We present a case study of a large (4,295 cc clinical target volume) retroperitoneal sarcoma treated to 50.4 Gy relative biological effectiveness (RBE) (presurgery) using a course of photons and protons to the clinical target volume and a course of protons to the gross target volume. Results: We describe our system and present the dosimetry for all courses and provide an interdosimetric comparison. Discussion: The use of PBS for bulky targets reduces the complexity of treatment planning and delivery compared with collimated proton fields. In addition, PBS obviates, especially for cases as presented here, the significant cost incurred in the construction of field-specific hardware. PBS offers improved dose distributions, reduced treatment time, and reduced cost of treatment.

07 ISOTOPE AND RADIATION SOURCES↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Prolonged Fraction Delivery Times Simulating IMRT on Cultured Nasopharyngeal Carcinoma Cell Killing

Purpose: To determine the impact of prolonged fraction delivery times (FDTs) simulating intensity-modulated radiotherapy (IMRT) on cultured nasopharyngeal carcinoma (NPC) cell killing. Methods and Material: Cultured NPC cell lines CNE1 and CNE2 were used in this study. The biological effectiveness of fractionated irradiation protocols simulating conventional external beam radiotherapy and IMRT (FDT of 15, 36, and 50 minutes) was estimated with standard colony assay, and the differences in cell surviving fractions after irradiation with different protocols were tested by use of the paired t test. The impact degree of prolonged FDTs (from 8 to 50 minutes) on cell killing was also assessed by the dose-modifying factors, which were estimated by comparing the effectiveness of intermittently delivered 2 Gy with that of continuously delivered 1.5 to 2 Gy. Results: The cell surviving fractions of both CNE1 and CNE2 after fractionated irradiation simulating IMRT were higher than those simulating conventional external beam radiotherapy (p < 0.05). The dose-modifying factors for a fraction dose of 2 Gy increased from 1.05 to 1.18 for CNE1 and from 1.05 to 1.11 for CNE2 with the FDT being prolonged from 15 to 50 minutes. Conclusions: This study showed that the prolonged FDTs simulating IMRT significantly decreased the cell killing in both CNE1 and CNE2 cell lines, and these negative effects increased with the FDT being prolonged from 15 to 50 minutes. These effects, if confirmed by in vivo and clinical studies, need to be considered in designing IMRT treatments for NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Non-Coplanar Liver SBRT: A Novel Delivery Technique

Purpose: To improve the quality of liver stereotactic body radiation therapy (SBRT) treatments, a novel 4π framework was developed with accompanying algorithms to optimize non-coplanar beam orientations and fluences. The dose optimization is performed on a patient-specific deliverable beam geometry solution space, parameterized with patient and linear accelerator gantry orientations. Methods and Materials: Beams causing collision between the gantry and the couch or patient were eliminated by simulating all beam orientations using a precise computer assisted design model of the linear accelerator and a human subject. Integrated beam orientation and fluence map optimizations were performed on remaining beams using a greedy column generation method. Testing of the new method was performed on 10 liver SBRT cases previously treated with 50 to 60 Gy in 5 fractions using volumetric modulated arc therapy (VMAT). For each patient, both 14 and 22 non-coplanar fields were selected and optimized to meet the objective of ≥95% of the planning target volume (PTV) covered by 100% of the prescription dose. Doses to organs at risk, normal liver volumes receiving <15 Gy, integral dose, and 50% dose spillage volumes were compared against the delivered clinical VMAT plans. Results: Compared with the VMAT plans, the 4π plans yielded reduced 50% dose spillage volume and integral dose by 22% (range 10%-40%) and 19% (range 13%-26%), respectively. The mean normal liver volume receiving <15 Gy was increased by 51 cc (range 21-107 cc) with a 31% reduction of the mean normal liver dose. Mean doses to the left kidney and right kidney and maximum doses to the stomach and spinal cord were on average reduced by 70%, 51%, 67%, and 64% (P≤.05). Conclusions: This novel 4π non-coplanar radiation delivery technique significantly improved dose gradient, reduced high dose spillage, and improved organ at risk sparing compared with state of the art VMAT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoparticle-Based Brachytherapy Spacers for Delivery of Localized Combined Chemoradiation Therapy

Purpose: In radiation therapy (RT), brachytherapy-inert source spacers are commonly used in clinical practice to achieve high spatial accuracy. These implanted devices are critical technical components of precise radiation delivery but provide no direct therapeutic benefits. Methods and Materials: Here we have fabricated implantable nanoplatforms or chemoradiation therapy (INCeRT) spacers loaded with silica nanoparticles (SNPs) conjugated containing a drug, to act as a slow-release drug depot for simultaneous localized chemoradiation therapy. The spacers are made of poly(lactic-co-glycolic) acid (PLGA) as matrix and are physically identical in size to the commercially available brachytherapy spacers (5 mm × 0.8 mm). The silica nanoparticles, 250 nm in diameter, were conjugated with near infrared fluorophore Cy7.5 as a model drug, and the INCeRT spacers were characterized in terms of size, morphology, and composition using different instrumentation techniques. The spacers were further doped with an anticancer drug, docetaxel. We evaluated the in vivo stability, biocompatibility, and biodegradation of these spacers in live mouse tissues. Results: The electron microscopy studies showed that nanoparticles were distributed throughout the spacers. These INCeRT spacers remained stable and can be tracked by the use of optical fluorescence. In vivo optical imaging studies showed a slow diffusion of nanoparticles from the spacer to the adjacent tissue in contrast to the control Cy7.5-PLGA spacer, which showed rapid disintegration in a few days with a burst release of Cy7.5. The docetaxel spacers showed suppression of tumor growth in contrast to control mice over 16 days. Conclusions: The imaging with the Cy7.5 spacer and therapeutic efficacy with docetaxel spacers supports the hypothesis that INCeRT spacers can be used for delivering the drugs in a slow, sustained manner in conjunction with brachytherapy, in contrast to the rapid clearance of the drugs when administered systemically. The results demonstrate that these spacers with tailored release profiles have potential in improving the combined therapeutic efficacy of chemoradiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Experience With Markerless Online 3D Spine Position Monitoring During SBRT Delivery Using a Conventional LINAC

The purpose was to report our initial experience with online markerless 3-dimensional (3D) spine position monitoring. We used template matching plus triangulation of fluoroscopic kilovoltage images acquired with the gantry-mounted imager during flattening filter-free volumetric modulated arc spine stereotactic body radiation therapy delivery on a conventional linear accelerator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oral delivery of a functional algal-expressed TGF-β mimic halts colitis in a murine DSS model

Inflammatory bowel disease (IBD) is a set of immunological disorders which can generate chronic pain and fatigue associated with the inflammatory symptoms. The treatment of IBD remains a significant hurdle with current therapies being only partially effective or having significant side effects, suggesting that new therapies that elicit different modes of action and delivery strategies are required. TGM1 is a TGF-β mimic that was discovered from the intestinal helminth parasite Heligmosomoides polygyrus and is thought to be produced by the parasite to suppress the intestinal inflammation response to help evade host immunity, making it an ideal candidate to be developed as a novel anti-inflammatory bio-therapeutic. Here we utilized the expression system of the edible green algae Chlamydomonas reinhardtii in order to recombinantly produce active TGM1 in a form that could be ingested. C. reinhardtii robustly expressed TGM1, and the resultant recombinant protein is biologically active as measured by regulatory T cell induction. When delivered orally to mice, the algal expressed TGM1 is able to ameliorate weight loss, lymphadenopathy, and disease symptoms in a mouse model of DSS-induced colitis, demonstrating the potential of this biologic as a novel treatment of IBD.

09 BIOMASS FUELS↗

Delivery of Vegetable Oil Suspensions in a Shear Thinning Fluid for Enhanced Bioremediation

In situ anaerobic biological processes are widely applied for dechlorination of chlorinated solvents in groundwater. A wide range of organic substrates have been tested and applied to support the dechlorination processes. Vegetable oils are a promising substrate and have been shown to induce effective dechlorination, have limited geochemical impacts, and good longevity. Distribution of vegetable oil in the subsurface, because it is a non-aqueous phase material, has typically been addressed by creating emulsified oil solutions. In this study, inexpensive waste vegetable oils were suspended in a xanthan gum solution, a shear-thinning fluid, as an alternative oil delivery mechanism. The stability, oil droplet size and distribution, and rheological behavior of the oil suspensions that are created in the xanthan solutions were studied in batch experiments. The injectability of the suspensions and oil distribution in porous medium were evaluated in column tests. Numerical modeling of the oil droplet transport and distribution in porous media was conducted to help interpret the column-test data. Batch studies showed that simple mixing of vegetable oil and xanthan solution produced stable suspensions of the oil as micron-size droplets. The mixture rheology retains shear-thinning properties that facilitate improved uniformity of substrate distribution in heterogeneous aquifers. Column tests demonstrated successful injection of the vegetable oil suspension into porous medium. This study provided evidence that vegetable oil suspensions in xanthan are a potential substrate to support in situ anaerobic bioremediation with favorable injection properties.

Zhong, Lirong↗

Sustainability of carbon delivery to an algal biorefinery: A techno-economic and life-cycle assessment

Supplementation of carbon is critical for high productivity cultivation of most microalgae. Moreover, using microalgae for atmospheric CO 2 mitigation to combat climate change is promising as waste sources and atmospheric CO 2 can be utilized to produce useful products. The challenge is developing technologies, processes, and strategies that utilize carbon efficiently such that the overall system is sustainable. Through engineering system modeling combined with techno-economic and life-cycle assessments, this study examined the implications of various delivery methods of carbon to a production-scale algal biorefinery. Five primary carbon sources were considered: atmospheric CO 2 ; CO 2 from direct chemical or power plant waste emissions; CO 2 that has been concentrated from waste sources and compressed; inorganic carbon in the form of hydrogen carbonate; and organic carbon in the form of cellulosic sugars derived from corn stover. Each source was evaluated assuming co-location as well as pipeline transportation up to 100 km. Sustainability results indicate that economics are more prohibitive than energy and emissions. Furthermore, of the scenarios evaluated, only two met both the economic and environmental criteria of contributing less than 0.50 US-$ GGE -1 and 20 g CO 2-eq MJ -1 to the overall system, respectively: uncompressed, pure sources of gaseous CO 2 with pipeline transportation of 40 km or less; and compressed, supercritical CO 2 from pure sources for pipeline transportation up to 100 km. A first order scalability assessment of algal biofuels based on these results shows carbon to be a limiting nutrient in an algal biorefinery with a total US production capability of 360 million gallons of fuel per year.

42 ENGINEERING↗

pH-responsive drug delivery system based on AIE luminogen functionalized layered zirconium phosphate nano-platelets

Aggregation-induced emission (AIE) luminogen, quaternary tetraphenylethene cation (TPEN), was successfully incorporated into layered α-zirconium phosphate (α-ZrP) by using co-precipitation method to form inorganic–organic hybrid materials. The obtained materials show the characteristic hexagonal platelet shape with the interlayer distance did not reveal significant difference compared with pure α-ZrP. In addition, the obtained hybrid materials emit strong blue emission centered at 476 nm in aqueous media due to the electrostatic interactions of TPEN with the anionic framework of α-ZrP, which largely restrict their intramolecular rotation. More importantly, the materials provide a pH dependent release of doxorubicin (DOX), suggesting that AIE luminogen functionalized α-ZrP may be used as an imaging guided and pH-responsive delivery system for targeting therapy. - Graphical abstract: AIE luminogen was successfully incorporated into layered α-zirconium phosphate by a co-precipitation method to form inorganic–organic hybrid materials, showing a pH dependent release of DOX. - Highlights: • AIE luminogen cation was incorporated into layered α-ZrP by co-precipitation method. • The obtained material emits strong blue emission upon UV irradiation. • The material exhibits pH dependent release of DOX. • The AIE functionalized α-ZrP has potential applications in imaging guided therapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alendronate functionalized mesoporous hydroxyapatite nanoparticles for drug delivery

Highlights: ► The synthesized mesoporous hydroxyapatite has nanostructure and bioactivity. ► The materials have high surface area and amino group. ► The materials show higher drug loading and slower release rate than pure HAP. - Abstract: Mesoporous nanosized hydroxyapatite (HAP) functionalized by alendronate (ALN) was synthesized using cationic surfactant CTAB as template. The structural, morphological and textural properties were fully characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and N{sub 2} adsorption/desorption. Then the obtained materials were performed as drug delivery carriers using ibuprofen (IBU) as a model drug to investigate their drug storage/release properties in simulated body fluid (SBF). The materials showed relatively slower release rate compared with HAP due to the ionic interaction between -NH{sub 3}{sup +} on the matrix and -COO{sup −}belongs to IBU. The system provides a new concept for improving the drug loading or slowing down the release rate.

36 MATERIALS SCIENCE↗

Synthesis and characterization of pharmaceutical surfactant templated mesoporous silica: Its application to controlled delivery of duloxetine

Graphical abstract: - Highlights: • Usefulness of dual pharmaceutical surfactants in silica synthesis was evaluated. • Effects of concentration of secondary template (Tween-40) were studied. • Effects of fixed solvothermal condition on mesostructure formation were studied. • Duloxetine drug loading capability was studied. • Sustained release of duloxetine was evaluated. - Abstract: A new group of mesoporous silica nanoparticles (MSNs) were synthesized using combination pharmaceutical surfactants, Triton X-100 and Tween-40 as template and loaded with duloxetine hydrochloride (DX), for improving the sustained release of DX and patterns with high drug loading. Agglomerated spherical silica MSNs were synthesized by sol–gel and solvothermal methods. The calcined and drug loaded MSNs were characterized using X-ray diffraction (XRD), Braunner–Emmett–Teller (BET), thermogravimetric analysis (TGA), Fourier-transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), differential scanning calorimetry (DSC), diffuse reflectance ultraviolet–visible (DRS-UV–vis) spectroscopy. MSNs with high surface area and pore volume were selected and studied for their DX loading and release. The selected MSNs can accommodate a maximum of 34% DX within it. About 90% was released at 200 h and hence, the synthesized MSNs were capable of engulfing DX and sustain its release. Further form the Ritger and Peppas, Higuchi model for mechanism drug release from all the MSN matrices follows anomalous transport or Non-Fickian diffusion with the ‘r’ and ‘n’ value 0.9 and 0.45 < n < 1, respectively. So, from this study it could be concluded that the MSNs synthesized using pharmaceutical templates were better choice of reservoir for the controlled delivery of drug which requires sustained release.

36 MATERIALS SCIENCE↗

Dosimetric Effects of Setup Uncertainties on Breast Treatment Delivery

This study aimed to assess the dosimetric impact of setup errors during the delivery of radiotherapy to the breast, and use this information to make recommendations on intervention tolerances for portal imaging of breast treatments. Translational and rotational setup errors were simulated for 10 recent breast patients using an Oncentra MasterPlan treatment planning system. The effect of these errors on the breast and tumor bed target volumes receiving 95% and 107% of the prescribed dose were assessed. For the majority of patients, shifts of up to 10 mm or a 4 deg. patient rotation about the cranio-caudal axis had no significant effect on the dose distribution. Changes in dosimetry were more likely if the reference plan contained large hot or cold spots. For a typical patient, it is estimated that a shift of 5 mm in any one direction, or a 2 deg. patient rotation would not cause more than a 5% change in the target volume receiving between 95% and 107% of the prescribed dose. If combinations of errors occur, greater dosimetric changes would be expected. It is concluded that individual patient shifts of up to 5 mm or rotations about the cranio-caudal axis of 2 deg. or less are unlikely to affect dose-volume histogram parameters by an amount judged as clinically significant. Setup errors exceeding these values may cause large dosimetric changes for some patients, particularly those with larger hot or cold regions in the dose distribution, and intervention is therefore recommended.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Simple IMRT Delivery Techniques for Non-Small Cell Lung Cancer Patients with Respiratory Motion Using 4DCT

Techniques for generating simplified IMRT treatment plans for treating non-small cell lung cancer (NSCLC) patients with respiratory motion were investigated. To estimate and account for respiratory motion, 4-dimensional computed tomography (4DCT) datasets from 5 patients were used to design 5-field 6-MV ungated step-and-shoot intensity modulated radiotherapy (IMRT) plans delivering a dose of 66 Gy to the planning target volume (PTV). For each patient, 2 plans were generated using the mean intensity and the maximum intensity of 10 CT datasets from different breathing phases. The plans also utilized different margins around the clinical target volume/internal target volume (CTV/ITV) to account for tumor motion. To reduce the treatment time and ensure accurate dose delivery to moving targets, the number of intensity levels was minimized while maintaining dose coverage to PTV and minimizing dose to organs at risk (OARs). Dose-volume histograms (DVHs), dosimetric metrics, and outcome probabilities were evaluated for all plans. Plans using the averaged CT image dataset were inferior, requiring larger margins around the PTV, with a maximum of 1.5 cm, to ensure coverage of the tumor, and therefore increased the dose to OARs located in proximity of the tumor. The plans based on superimposed CT image datasets achieved full coverage of the tumor, while allowing tight margins around the PTV and minimizing the dose to OARs. A small number of intensity-levels (3 to 5), resulting in IMRT plans with a total of 13 to 30 segments, were sufficient for homogeneous PTV coverage, without affecting the sparing of OARs. In conclusion, a technique involving treatment planning with the superimposed CT scans of all respiratory phases, and the application of IMRT with only a small number of segments was feasible despite significant tumor motion; however, greater patient numbers are needed to support the statistical significance of the results presented in this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of the arrays was verified by comparison with film and by rotating the detector 180{sup o}. The dosimeter response to rotational irradiation changed by no more than 0.2% when one of the detector boards was replaced by the homogeneous phantom material. The daily output correction factor can be derived from a Delta4 measurement in a uniform cylindrical field. The {gamma}(3%, 3 mm) passing rate (absolute dose) was above 90% for all 9 evaluated clinical plans, and above 96% for all but one. The mean passing rate was 97 {+-} 2.7%. The plans varied in modulation factor, pitch, and calculation grid size. For best results, the phantom needs to be aligned carefully, preferably by megavoltage computed tomography imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Helical Tomotherapy-Based STAT Stereotactic Body Radiation Therapy: Dosimetric Evaluation for a Real-Time SBRT Treatment Planning and Delivery Program

Stereotactic body radiation therapy (SBRT) treatments have high-dose gradients and even slight patient misalignment from the simulation to treatment could lead to target underdosing or organ at risk (OAR) overdosing. Daily real-time SBRT treatment planning could minimize the risk of geographic miss. As an initial step toward determining the clinical feasibility of developing real-time SBRT treatment planning, we determined the calculation time of helical TomoTherapy-based STAT radiation therapy (RT) treatment plans for simple liver, lung, and spine SBRT treatments to assess whether the planning process was fast enough for practical clinical implementation. Representative SBRT planning target volumes for hypothetical liver, peripheral lung, and thoracic spine lesions and adjacent OARs were contoured onto a planning computed tomography scan (CT) of an anthropomorphic phantom. Treatment plans were generated using both STAT RT 'full scatter' and conventional helical TomoTherapy 'beamlet' algorithms. Optimized plans were compared with respect to conformality index (CI), heterogeneity index (HI), and maximum dose to regional OARs to determine clinical equivalence and the number of required STAT RT optimization iterations and calculation times were determined. The liver and lung dosimetry for the STAT RT and standard planning algorithms were clinically and statistically equivalent. For the liver lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.04 and 1.04 and HI of 1.03 and 1.03, respectively. For the lung lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.05 and 1.03 and HI of 1.05and 1.05, respectively. For spine lesions, 'full scatter' and 'beamlet' algorithms showed a CI of 1.15 and 1.14 and HI of 1.22 and 1.14, respectively. There was no difference between treatment algorithms with respect to maximum doses to the OARs. The STAT RT iteration time with current treatment planning systems is 45 sec, and the treatment planning required 3 iterations or 135 sec for STAT RT liver and lung SBRT plans and 7 iterations or 315 sec for STAT RT spine SBRT plans. Helical TomoTherapy-based STAT RT treatment planning with the 'full scatter' algorithm provides levels of dosimetric conformality, heterogeneity, and OAR avoidance for SBRT treatments that are clinically equivalent to those generated with the Helical TomoTherapy 'beamlet' algorithm. STAT RT calculation times for simple SBRT treatments are fast enough to warrant further investigation into their potential incorporation into an SBRT program with daily real-time planning. Development of methods for accurate target and OAR determination on megavoltage computed tomography scans incorporating high-resolution diagnostic image co-registration software and CT detector-based exit dose measurement for quality assurance are necessary to build a real-time SBRT planning and delivery program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of image value-to-density table (IVDT) on the accuracy of delivery quality assurance (DQA) process in helical tomotherapy

The effect of the accuracy in the application of the image value-to-density table (IVDT) from kilovoltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) images on the delivery quality assurance (DQA) in helical tomotherapy (HT) was analyzed. The DQA plans were prepared with a kVCT image of a cheese phantom for 10 HT patients, and the difference in absolute dose equivalence between the planned and real measurement was evaluated according to the accuracy of IVDT application. The difference between the calculated dose distribution and real dose distribution measured with MapCHECK (SunNuclear, Melbourne, FL) was analyzed through the DQA process with a kVCT MapCHECK image and the same analysis was performed with an MVCT MapCHECK image. The IVDT for kVCT was applied to MVCT and the variation in error between the planned and real measurement caused by improper application of IVDT was evaluated. The accuracy of the IVDT application in the homogeneous water-equivalent cheese phantom had only a minor influence on the dose calculation. Although the overall accuracy of the calculated dose was increased when the proper IVDT was applied, this result had no statistical significance. The MVCT image of MapCHECK contained less error between the calculated dose and delivered dose with a high pass rate. The proper IVDT application to the MVCT image of MapCHECK increased the accuracy of dose calculation, and this result had a statistical significance. Application of the correct IVDT is important in HT DQA and its significance is increased when using phantoms consisting of inhomogeneous density materials.

61 RADIATION PROTECTION AND DOSIMETRY↗