Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DECOMPRESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Deciphering Extreme Mineral Records; Microstructural Phase Heritage of Shocked Materials

High-pressure minerals such as coesite, stishovite, and reidite are often used as indicators of shock metamorphism. However, high-pressure and high-temperature phases are metastable at ambient conditions and, therefore, often revert to a more energetically favorable phase. During solid-state transformations, the crystallographic orientations of the stable polymorph are controlled by the transformation pathway from the parent. Microstructural orientation analysis using electron backscatter diffraction (EBSD) of the stable phase can reveal systematic intercrystalline orientation relationships (OR) diagnostic of solid-state transformations from these high-pressure or high-temperature polymorph phases (Cayron et al., 2006). Knowledge of polymorph stability fields for a given system can thus be used to infer minimum shock P and/or T conditions that rocks have experienced, which are otherwise unavailable using traditional thermobarometers such as element partition coefficients. Using orientation relationships to infer the former presence of mineral phases has been termed microstructural “phase heritage”, and has successfully been used to probe for evidence of extreme pressures and temperatures resulting from hypervelocity impacts. The reconstruction of polymorphs of ZrSiO4 (zircon, reidite) and ZrO2 (baddeleyite) have further elucidated the behavior of these phases under hypervelocity impact conditions (Timms et al., 2017a; White et al., 2018), and OR analysis of shocked monazite has identified a previously unrecognized tetragonal high-P polymorph (Erickson et al., 2019). Zircon will convert to the low tetragonal polymorph reidite at shock stresses above ~21 GPa. However, upon decompression at temperatures above 1200 °C reidite will revert to zircon (Kusaba et al., 1985). Recrystallized zircon neoblasts encased in impact melt often show systematic misorientation relationships of 90° about <110> indicative of reversion from the reidite (Fig. 1), and preserving cryptic evidence of the high-P history that is often erased by the post shock thermal spike (Cavosie et al., 2016). Microstructural OR analysis of a dissociated zircon corona composed of baddeleyite (monoclinic-ZrO2) has identified the former presence of cubic zirconia within impact melt glass from the Mistastin Lake impact structure, Labrador, CA. Based on stability fields in the ZrO2-SiO2 binary phase diagram, cubic zirconia records thermal conditions in excess of 2370 °C at ambient P, indicating that the Mistastin impact melt is the hottest rock identified on Earth’s surface (Timms et al., 2017b). Shock-deformed monazite (monoclinic La,Ce,ThPO4) containing lamellae comprised of interlocking laths has been identified from the Haughton Dome impact structure, Nunavut, Canada and Nördlinger-Ries Crater, southern Germany. The lath-structured lamellae are composed of four systematic orientation variants, which OR analyses indicate originate from a tetragonal parent whereby the [010]monoclinic aligns with either [100] or [010]tetragonal (Erickson et al., 2019). These results highlight utility of microstructural phase heritage analyses for the identification of unstable high-P or high-T polymorphs that uniquely record the extremely transient shock conditions produced by hypervelocity impacts.

Timmons Erickson↗

Eruption Characterisitics of Lunar Localized Pyroclastic Deposits Based on Water Content, Mineralogy, Regolith Properties

Lunar pyroclastic deposits are low albedo deposits present throughout the lunar surface including both maria and highlands, nearside and farside, and high latitudes and equatorial regions [e.g., 1]. There are two main types of pyroclastic deposits based upon size: localized (<2500 km2) and regional pyroclastic deposits (>2500 km2) [1]. In this study, we focus on the smaller localized pyroclastic deposits. The first and most detailed study of localized pyroclastic deposits are the deposits in Alphonsus crater [2]. This study included examining the radar and volumetric properties of these deposits. They found that vulcanian-like eruptions are most consistent with their observations. They imagined that a dike intrudes into the crust and creates a cooled basaltic cap. With increasing pressure under the basaltic cap, the pressure eventually overwhelms the surrounding rocks and results in explosive decompression. Later studies examined several pyroclastic deposits across the lunar surface using radar [2–4], digital terrain models (DTMs) [2,4], visible and near-infrared spectrometers [1,4–7], and a radiometer [4] to determine the mineralogy (e.g., olivine, glass, clinopyroxene, orthopyroxene, and plagioclase), deposit thickness and volume, proportion of juvenile material, radar backscatter, surface rock abundance, and regolith density. These various properties were examined against one another to better group localized pyroclastic deposits and understand how they relate to one another [4]. One of the studies divided pyroclastic deposits into three groups based upon the shape of the 1-μm absorption feature. The three Groups could be interpretated as having highlands and pyroclastic material (Group I), mare and pyroclastic material (Group II), and glass and orthopyroxene material (Group III) [5]. Building on that foundation, another study divided the pyroclastic deposits into four groups based upon their surface rock abundance and glass abundance [4], where deposits are classified based upon low surface rock abundance and high glass abundance (Glassy deposits); high rock abundance, high glass abundance (Blocky deposits); moderate rock abundance and low glass abundance (Crystalline deposits); and high rock abundance and low glass abundance (Indistinct Group). In addition to these studies, we can now look at their water contents using the new Effective Single Particle Absorption Thickness (ESPAT) parameter map [8]. The ESPAT map measures the strength of the 3-μm absorption feature in single scattering albedo space. The strength of this feature and its relationship to water content has been calibrated to returned samples, which allows for water content to be derived from remote spectral data (i.e., Moon Mineralogy Mapper). The goal of this study is to examine how water content in the pyroclastic deposits varies with respect to the geometric, mineralogic, and physical properties of the localized pyroclastic deposits as measured by a previous study [i.e., 4]. A more complete version of this work is found in [9].

D Trang↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the space suit Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure for the crew member during pre-breathe, extra-vehicular activity (EVA), post EVA airlock operations, and decompression sickness treatment. The last time a spacesuit oxygen regulator was designed was for the Space Shuttle Program EMU. The regulator & EMU were then used on the International Space Station (ISS) with no significant changes to the regulator throughout its life. This xEMU PLSS spacesuit oxygen regulator implements many elements of the previous EMU Secondary Oxygen Pack (SOP) design while integrating numerous new improvements and changes. There are changes both to the high-level regulator architecture approach in the suit itself, in addition to modernizations with electrical motor control & sensing. For architecture, there are two oxygen regulators for each space suit, a primary and secondary that are nearly identical to each other and have the same maximum design pressure of 3750 Pounds per Square Inch Absolute (PSIA). The primary regulator provides nominal pressure during EVA, while the secondary provides a backup pressure only in case of primary regulator failure or if an emergency purge of the suit oxygen is required. The design was based originally off of the secondary oxygen regulator on the EMU which utilizes a two-stage regulator to improve safety and controllability. The xEMU PLSS Oxygen Regulator development started with a modification to add a linear actuator to the design to control the downstream pressure electronically instead of a manual control with a wire linkage system used with the EMU. The design was iterated to include a Monel body for oxygen fire safety, and sensors for pressure verification at each stage. Then the regulator design was packaged to fit into the xEMU PLSS envelope. Development included extensive testing which brought to light some issues with the design which were addressed at each stage of development. This paper will review the design history, development, testing results, and lessons learned designing the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Medical Lessons Learned from the Exploration Atmospheres Study

Background: The National Aeronautics and Space Administration’s (NASA) Exploration Atmospheres study (EA) was done to evaluate alternative cabin atmospheres for future spacecraft designs and planetary surface exploration of the Moon, Mars and beyond. Deep space exploration involves creating habitats and environments safe for human occupancy and means to explore the outside environment (extravehicular activities, EVA). In order to validate alternative atmospheres and pre-spacewalk procedures, the EA study was conducted to evaluate factors such as hypoxia risks, denitrogenation protocols, food limitations, medications, and the impact of other factors on human performance. Overview: Space travel is constrained by mass, volume, power and the cost of vehicle development, which creates tradeoffs in various capabilities, including breathing gasses. Higher atmospheric pressure in a vehicle means more gas, and a stronger containment vessel/habitat; while lower pressure requires higher oxygen partial pressure, which may increase fire risk. NASA’s EA study evaluated a proposed alternative cabin environment (8.2 psia, 34% Oxygen), for future spacecraft habitat, and planetary EVAs. EA included both a 3-day and a 11-day trial. These trials included a depressurization and saturation to 8.2psi at 34% O2 with additional depresses to 4.3 psia at 85% O2 for simulated EVAs, (1 EVA during the 3-day and 5 during the 11-day trials). Discussion: Planning for and executing the medical monitoring and response plan for a trial of this scope was a huge undertaking with no prior practice to fall back on. Food obstacles, sleeping issues, medications, joint injury, equipment limitations, medical privacy, multiple cases of decompression sickness, and even a COVID outbreak among the support team proved challenging. Conclusion: Testing of this nature is an essential part NASA’s preparation for the upcoming Lunar Artemis missions. As spaceflight transitions beyond low earth orbit, to planetary, even more trials of this nature will be required to learn what are the optimal atmospheric and associated operational constraints to maintain the optimal health of the crew and achieve mission objectives.

R Sanders↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew F J Abercromby↗

Detect-and-Avoid in Off-Nominal Situations for Supersonic Transport Aircraft in Upper Class E Airspace

This thesis researches potential failure conditions within supersonic and potential hypersonic aircraft. The most critical off-nominal situations have been identified to be Engine Failures, Rapid Decompression and High Altitude Radiation. Having in mind, current regulatory requirements as well as past operations of Concorde, potential locations for different speeds have been modeled to identify safe operational volumes. With an emphasis on the engine failure case as part of the thesis requirement, a potential first order approach to future DAA systems is described in order to add these models on top of current conflict resolution models.

supersonic↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew Abercromby↗

Coordinated Microstructural and Isotopic Characterization of Diamond Inclusions within the Kenna Ureilite

Introduction: The origin of diamonds in ureilitic meteorites, a major family of ultramafic achondrites, has long been debated, with various formation mechanisms inferred, including: 1) shock conversion of preexisting graphite due to a hypervelocity impact on the ureilite parent body [e.g., 1]; 2) vapor deposition during condensation of the solar nebula [e.g., 2]; or 3) static transformation in the mantle of a large planetesimal (>1000 km in diameter) [e.g., 3]. The Kenna ureilite is a 10.9 kg stone that was found in Kansas in 1972 and is dominantly composed of olivine and pigeonite (68% and 22% modal abundance, respectively), together with minor metal and carbon-rich regions. Within the carbon-rich domains researchers have identified microdiamonds up to ~10 µm in size [4]. Methods: Due to the proximity of the extremely hard microdiamonds with soft graphite and moderately hard silicates, achieving an appropriately flat surface for electron backscatter diffraction (EBSD) analysis has proven challenging. We have, therefore, employed a Hitachi ArBlade 5000 broad beam Ar ion milling system to prepare a sample with an adequately uniform surface flatness across the various minerals. The ion milling dramatically im-proved indexing of the EBSD patterns and facilitated high-resolution microstructural analysis of the carbon-rich domains. After microstructural EBSD analyses using an Oxford Symmetry detector we collected coordinated hy-perspectral cathodoluminescence (CL) analyses using a Gatan Monarc system mounted on a JEOL 7900F field emission (FE) scanning electron microscope at NASA Johnson Space Center. A focused ion beam (FIB) foil was extracted from a region of interest and analyzed using a JEOL 2500 FE scanning transmission electron microscope (STEM). In situ carbon and nitrogen isotopic analyses were collected from diamond-bearing domains using a Cameca NanoSIMS 50L at NASA JSC. Results: The carbon rich regions occur as tabular domains between polygonal olivine and pigeonite, and are composed of aggregates of micrometer-scale diamond with intermediate graphite, oxides and metal grains. Within the microdiamonds, {111} twins are abundant, many of which form ragged lamellae consistent with mechanical twinning. The microdiamond assemblages appear to pseudomorph tabular graphite habits, which together with the abundant deformation twins, support a shock transformation mechanism for microdiamond formation within the Kenna meteorite. Further supporting this observation, the diamond laths show close alignment of <111> and <110> between domains, consistent with a solid-state transformation from graphite along <0001> and <1-210>, respec-tively [5]. A FIB foil was extracted from a region with mechanical twins, and high resolution STEM analyses reveal cross-cutting veins of graphite and oriented kamacite crystals together with additional sets of {111} nano-twins formed in at least three orientations. Isotopic analyses of C and N reveal sector zoning patterns [cf. 3] that are unre-lated to the diamond substructure identified by EBSD yet consistent with hyperspectral CL images. Conclusions: These data provide new constraints on microdiamond formation within ureilites. The microdia-monds exhibit orientation variants defined by aligned <111> and <110> axes consistent with inherited crystallo-graphic orientations from transformation of a single hexagonal graphite parent crystal [5]. Crosscutting the micro-diamonds are veins of graphite and kamacite, together with additional {111} nanotwins. Taken together these data suggest that microdiamonds from ureilites formed from a solid state, diffusionless transformation from graphite, likely associated with a major shock event, which was subject to subsequent reversion either during decompression or a later deformation event. The N and C isotopic sector zoning is unrelated to diamond microstructures and likely reflects inheritance from the parent graphite crystal.

Ureilite↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure control for the crew member during prebreathe, Extra-Vehicular Activity (EVA), post EVA airlock operations, and Decompression Sickness (DCS) treatment. It has been over four decades since a new spacesuit oxygen regulator has been designed. The regulator and EMU that is presently used on the International Space Station (ISS) was developed for the space shuttle program without any significant changes made throughout its service life. The xEMU spacesuit oxygen regulator is based on the previous EMU Secondary Oxygen Pack (SOP). The new design integrates numerous improvements and changes including an innovative approach to regulator architecture, a more robust first stage pressure sensing mechanism, digital actuation control, and electronic pressure sensing. These upgrades replace manual control linkages, physical gauges, and enable infinitely variable pressure set points. The new setpoints can decrease prebreathe time and make in suit DCS treatment possible. Throughout its four iterations design concerns have been addressed, safety features have been added, and the envelope of the regulator designed to fit inside the xEMU PLSS package. This paper will review the history, design, testing, and lessons learned during the development of the xEMU PLSS Oxygen Regulator.

Ryan Eric Ogilvie↗

Space Suit Portable Life Support System (PLSS) Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure control for the crew member during prebreathe, Extra-Vehicular Activity (EVA), post EVA airlock operations, and Decompression Sickness (DCS) treatment. It has been over four decades since a new spacesuit oxygen regulator has been designed. The regulator and EMU that is presently used on the International Space Station (ISS) was developed for the space shuttle program without any significant changes made throughout its service life. The xEMU spacesuit oxygen regulator is based on the previous EMU Secondary Oxygen Pack (SOP). The new design integrates numerous improvements and changes including an innovative approach to regulator architecture, a more robust first stage pressure sensing mechanism, digital actuation control, and electronic pressure sensing. These upgrades replace manual control linkages, physical gauges, and enable infinitely variable pressure set points. The new setpoints can decrease prebreathe time and make in suit DCS treatment possible. Throughout its four iterations design concerns have been addressed, safety features have been added, and the envelope of the regulator designed to fit inside the xEMU PLSS package. This paper will review the history, design, testing, and lessons learned during the development of the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Development, Validation and Approval of A Planetary Extravehicular Activity Prebreathe Protocol: NASA Exploration Atmosphere Tests 1 & 2

INTRODUCTION: Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions as planned by the Artemis program. Living in an “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. A prebreathe validation campaign at NASA’s Johnson Space Center in 2022–2023 has aimed to validate the prebreathe durations and is being operationalized by NASA for use in upcoming Lunar EVAs. METHODS: Twelve volunteers lived in a hyboparic chamber for 11 days with an “exploration atmosphere” of 56.6kPa/34% O2 66% N2. Subjects acclimated to this atmosphere for 48 hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15 min, as well as clinical monitoring for DCS signs/symptoms. Venous gas emboli (VGE) and DCS outcomes were verified against NASA Standard 3001, which guides allowable prebreathe protocol acceptance criteria. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were identified during EVAs. No Grade IV VGE were observed. Two cases of mild, Type I DCS were identified in the subjects over the course of 50 EVA exposures. Ten planned EVA exposures were eliminated due to mask fit, metabolic rate, or subject safety concerns. One subject was removed from the study due to presence of left ventricular VGE. Additionally, two doppler techs also experienced DCS, and one case of hypoxia was noted. All cases of DCS resolved with treatment. No cases of severe DCS were observed. The observed incidence (4%, 1.1–13.5% at 95% confidence) met the NASA Standard 3001 criteria leading to the transition of this protocol from research to operational use for upcoming Lunar missions.

Exploration Atmosphere↗

Effects of Mild Hypobaric Hypoxia on Response From Mild Exercise in NASA Exploration Atmosphere Tests

INTRODUCTION: The NASA Exploration Atmosphere study aims to validate a new prebreathe protocol incorporating an alternate habitat atmosphere of 56.5 kPa (8.2psia), 34% O 2 , and 66% N 2 to control and mitigate decompression sickness risk associated with spaceflight extravehicular activities. This alternate atmosphere results in a mild hypoxic environment (PIO 2 of 128 mmHg) that may influence inhabitant physiological responses to exercise. Therefore, the responses to light exercise in relation to the mild hypobaric hypoxic environment were investigated. METHODS: Eight participants (4M/4F; age=38.3±9.0 yr; weight=76.0±13.1 kg; peak aerobic capacity [VO 2 pk]= 3.1±0.7 L/min) were exposed to a mild hypobaric hypoxic environment for 11 days in NASA’s 20-foot hypobaric chamber at Johnson Space Center. Participants alternated test days between a habitat atmosphere of 56.5 kPA/34% O 2 and simulated 6-hour EVA environment, 29.6 kPa/85% O 2 . Participants completed pre-mission graded VO 2 pk tests on a LODE cycle ergometer with ParvoMedics metabolic analyzer. Submaximal aerobic tests were performed pre and during the mission (10-minutes of exercise at a workload of 40% VO 2 pk).Pre-mission, performed submaximal exercise exposed to a breathing air mixture of, 18% O 2 and balance N 2 , to simulate the mildly hypoxic environment within the 20-foot chamber. Linear mixed models (fixed effect: test day; random effects: subject, age) were performed to determine whether physiological responses (oxygen uptake [VO 2 ], carbon dioxide production [VCO 2 ], ventilation [VE], oxygen saturation [SPO 2 ], heart rate [HR], respiratory exchange ratio [RER]) to submaximal exercise performed within the 20-foot hypobaric chamber every 2 days differed from the pre-mission (18% O 2 ) testing. Results are presented as estimated marginal means with lower and upper confidence limits, with significance set to 0.05. RESULTS AND DISCUSSION: Seven of eight participants completed the chamber study. Mixed models for VO 2 , VCO 2 , SpO 2 , HR, and RER indicated negligible impact of the mild hypoxic chamber environment compared to pre-mission testing (all p>0.05).Results for VE indicated a minor impact of chamber environment compared to pre-mission testing (37.0 L/min [30.8, 43.2]), with increased VE at test day 10 (40.4 L/min [34.2, 46.6]; p= 0.029).The aerobic performance data collected suggests limited physiologic responses to mild exercise when performed at normobaric hypoxia and hypobaric hypoxia.

B Siders↗

Quantifying Risk to Improve Medical System Design for Long Duration Artemis Missions: A Demonstration of NASA's IMPACT Tradespace Analysis Tool

BACKGROUND NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. A greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the evacuation of ill or injured crew. Mass, volume, and power will be limited while higher demands will be placed on the crews to manage medical events. NASA’s Moon to Mars exploration strategy outlines increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human system risk attributable to medical conditions and use these estimates to advance medical system design. METHODS IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a probabilistic risk assessment (PRA) and tradespace analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; a large increase in the number of medical resources and the flexibility of their use; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to mimic a foundational exploration Artemis mission. The DRM profile includes outbound transit on Orion, Gateway space station rendezvous in lunar orbit, 6 months on the Lunar surface with extravehicular activity (EVA), return rendezvous with Gateway, and transit back to Earth. RESULTS/DISCUSSION: Overall, IMPACT successfully quantified medical risk and derived an optimal medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to medical risk were decompression sickness, trauma, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions and performed as expected. This demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Arian Anderson↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

High Performance Access to Archival Data Stored in HDF4 and HDF5 on Cloud Object Stores Without Reformatting the Files

Cloud computing offers numerous advantages for users of extensive Earth science data collections. These benefits encompass direct online access to data files and granules from any location, scalable access supporting parallel computing workflows, and flexible computing tools enabling innovative experimentation with processing techniques. However, older archival file formats designed for distinct computing systems hinder efficient access to decade-long time-series data when compared to data stored in modern cloud-optimized formats like Web Object Stores (WOS), exemplified by Amazon Web Services’ Simple Storage Service (S3). We describe DMR++ (Dataset Metadata Response plus plus), a technology facilitating efficient access to HDF5 (Hierarchical Data Format, version 5) and HDF4 files stored on WOS systems without requiring data reformatting. DMR++ achieves performance comparable to technologies like Zarr while preserving the original file structure, a substantial benefit considering the vast quantity of archival files held by organizations such as NASA. Moreover, DMR++ typically outperforms cloud-optimized versions of HDF5. Essentially an XML (Extensible Markup Language) document usually stored alongside the described data, DMR++ can also be generated on-the-fly but is generally created during data staging to the WOS. Archival files that use HDF4/5 often store large arrays of numerical data. The data in these files is often compressed, typically reducing their size by a factor of four or more. To achieve efficient access to portions of those arrays, they are 'chunked' into smaller sub-arrays, each individually compressed. The chunk size is a compromise, where spinning disks can efficiently access data in smaller chunks while S3 favors larger chunks. A simple optimization of aggregating smaller chunks that are stored adjacently, transferring them in a single access and then individually decompressing them will improve performance. NASA data pose an additional challenge: special Application Programmer Interface (API) libraries are often needed to compute some variables. These libraries are incompatible with WOS environments. Our solution involves storing computed values in the DMR++ document or a companion file, making them accessible like other variables and eliminating the need for specialized APIs. We outline specific optimizations for both satellite grid and swath data stored in HDF4-EOS2 (Earth Observing System).

James Gallagher↗