Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bringing Fenton Hill into the Digital Age: Data Conversion in Support of the Geothermal Technologies Office Code Comparison Study Challenge Problems

The Geothermal Technologies Office Code Comparison Study (GTO-CCS) was established by the U.S. Department of Energy to facilitate collaboration among members of the geothermal modeling community and to evaluate and improve upon the ability of existing codes to simulate thermal, hydrological, mechanical, and chemical processes associated with complex enhanced geothermal systems (EGS). The first stage of the project, which has been completed, involved comparing simulations for seven benchmark problems that were primarily designed using well-prescribed, simplified data sets. In the second stage, the participating teams are tackling two challenge problems based on the EGS research conducted in hot dry rock (HDR) at Fenton Hill, near Los Alamos, New Mexico. The Fenton Hill project, conducted by Los Alamos National Laboratory (LANL) from 1970 to 1995, was the world’s first HDR demonstration project. One of the criteria for selecting this experiment as the basis for the challenge problems was the amount and availability of data for generating model inputs. The Fenton Hill HDR system consisted of two reservoirs – an earlier Phase I reservoir tested from 1974 to 1981 and a deeper Phase II reservoir tested from 1980 to 1995. Detailed accounts of both phases of the HDR project have been presented in a number of books and reports, including a recently published summary of the lessons learned and a final report with a chronological description of the Fenton Hill project, prepared by LANL. Project documents and records have been archived and made public through the National Geothermal Data System (NGDS). Some of the data acquired from Phase II are available in electronic format readable on modern computers. These include the microseismic data from some of the important experiments (e.g. the massive hydraulic fracturing test conducted in 1983) and the injection/production wellhead data from the circulation tests conducted between 1992-1995. However, much of the data collected during the project, while publicly available, currently only exist in the form of tables or graphs within scanned documents. Therefore, in support of the GTO-CCS, the data needed for developing simulation inputs are being compiled and converted to platform independent, open readable formats so that all participating teams will have access to the same electronic data set. In some cases this requires conversion using optical character recognition, digitizing existing images, and generating the appropriate metadata from project documents. The GTO-Velo knowledge management framework, developed by Pacific Northwest National Laboratory (PNNL), was used for the benchmark problem stage of the comparison study and will also be used as the data repository for the challenge problem data sets. It is staggering and impractical to convert all published data for the Fenton Hill site, so the focus is on data that supports simulations for the three topical areas defined by the study for the challenge problems: 1) reservoir creation/stimulation, 2) reactive and passive transport, and 3) thermal recovery. Conversion of these data provide value not only to GTO-CCS participants, but also to members of the geothermal community at large who may be interested in revisiting the Fenton Hill experiment in the future.

Code Comparison Study↗

Quality Assurance and Quality Control (QA/QC) of Meteorological Time Series Data for Billy Barr, East River, Colorado USA

A comprehensive Quality Assurance (QA) and Quality Control (QC) statistical framework consists of three major phases: Phase 1—Preliminary raw data sets exploration, including time formatting and combining datasets of different lengths and different time intervals; Phase 2—QA of the datasets, including detecting and flagging of duplicates, outliers, and extreme values; and Phase 3—the development of time series of a desired frequency, imputation of missing values, visualization and a final statistical summary. The time series data collected at the Billy Barr meteorological station (East River Watershed, Colorado) were analyzed. The developed statistical framework is suitable for both real-time and post-data-collection QA/QC analysis of meteorological datasets.The files that are in this data package include one excel file, converted to CSV format (Billy_Barr_raw_qaqc.csv) that contains the raw meteorological data, i.e., input data used for the QA/QC analysis. The second CSV file (Billy_Barr_1hr.csv) is the QA/QC and flagged meteorological data, i.e., output data from the QA/QC analysis. The last file (QAQC_Billy_Barr_2021-03-22.R) is a script written in R that implements the QA/QC and flagging process. The purpose of the CSV data files included in this package is to provide input and output files implemented in the R script.

54 ENVIRONMENTAL SCIENCES↗

Method and Apparatus for Monitoring of Daily Activity in Terms of Ground Reaction Forces

A device to record and analyze habitual daily activity in terms of the history of gait-related musculoskeletal loading is disclosed. The device consists of a pressure-sensing insole placed into the shoe or embedded in a shoe sole, which detects contact of the foot with the ground. The sensor is coupled to a portable battery-powered digital data logger clipped to the shoe or worn around the ankle or waist. During the course of normal daily activity, the system maintains a record of time-of-occurrence of all non-spurious foot-down and lift-off events. Off line, these data are filtered and converted to a history of foot-ground contact times, from which measures of cumulative musculoskeletal loading, average walking- and running-specific gait speed, total time spent walking and running, total number of walking steps and running steps, and total gait-related energy expenditure are estimated from empirical regressions of various gait parameters to the contact time reciprocal. Data are available as cumulative values or as daily averages by menu selection. The data provided by this device are useful for assessment of musculoskeletal and cardiovascular health and risk factors associated with habitual patterns of daily activity.

Whalen, Robert T.↗

Defining a Metric to Assess Leachability of Contaminants from Cementitious Waste Forms in Lab Testing Related to Hanford - 20478

This paper reports on the determination of performance metrics for the release of four contaminants (technetium, iodine, nitrate, and chromium) from a theoretical supplemental low-activity waste (LAW) inventory of grout in the Hanford Integrated Disposal Facility (IDF). The performance metric was defined as a retardation factor, R, that can be used to quantify a waste form's ability to retain one contaminant compared with an un-retarded species (e.g., sodium). By setting the target R value at the magnitude required to maintain concentrations of the contaminants below the drinking water standard at the point of compliance for the IDF, a bar for grout leach performance can be established for screening laboratory leach test data. The R can be converted to a corresponding laboratory-observed diffusivity value against which to assess leach test data. The individual performance metrics were determined through an iterative set of simulations using a variable saturation and transport flow model of a grout waste form inventory in the IDF to calculate the resulting concentration-based requirements at the point of compliance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AtomAI framework for deep learning analysis of image and spectroscopy data in electron and scanning probe microscopy

Over the past several decades, electron and scanning probe microscopes have become critical components of condensed matter physics, materials science and chemistry research. At the same time, the infrastructure for establishing a connection between microscopy observations and materials behaviour over a broader parameter space is lacking. In this work, we introduce AtomAI, an open-source software package bridging instrument-specific Python libraries, deep learning and simulation tools into a single ecosystem. AtomAI allows direct applications of deep neural networks for atomic and mesoscopic image segmentation converting image and spectroscopy data into class-based local descriptors for downstream tasks such as statistical and graph analysis. For atomically resolved imaging data, the output is types and positions of atomic species, with an option for subsequent refinement. AtomAI further allows the implementation of a broad range of image and spectrum analysis functions, including invariant variational autoencoders for disentangling structural factors of variation and im2spec type of encoder–decoder models for mapping structure–property relationships. Finally, our framework allows seamless connection to the first principles modelling with a Python interface on the inferred atomic positions.

36 MATERIALS SCIENCE↗

Application of physical parameter identification to finite element models

A time domain technique for matching response predictions of a structural dynamic model to test measurements is developed. Significance is attached to prior estimates of physical model parameters and to experimental data. The Bayesian estimation procedure allows confidence levels in predicted physical and modal parameters to be obtained. Structural optimization procedures are employed to minimize an error functional with physical model parameters describing the finite element model as design variables. The number of complete FEM analyses are reduced using approximation concepts, including the recently developed convoluted Taylor series approach. The error function is represented in closed form by converting free decay test data to a time series model using Prony' method. The technique is demonstrated on simulated response of a simple truss structure.

Bronowicki, Allen J.↗

LAPS Lidar Measurements at the ARM Alaska Northslope Site (Support to FIRE Project)

This report consists of data summaries of the results obtained during the May 1998 measurement period at Barrow Alaska. This report does not contain any data interpretation or analysis of the results which will follow this activity. This report is forwarded with a data set on magnetic media which contains the reduced data from the LAPS lidar in 15 minute intervals. The data was obtained during the period 15-30 May 1998. The measurement period overlapped with several aircraft flights conducted by NASA as part of the FIRE project. The report contains a summary list of the data obtained plus figures that have been prepared to help visualize the measurement periods. The order of the presentation is as follows: Section 1. A copy of the Statement of Work for the planned activity of the second measurement period at the ARM Northslope site is provided. Section 2. A list of the data collection periods shows the number of one minute data records stored during each hour of operation and the corresponding size (Mbytes) of the one hour data folders. The folder and file names are composed from the year, month, day, hour and minute. The date/time information is given in UTC for easier comparison with other data sets. Section 3. A set of 4 comparisons between the LAPS lidar results and the sondes released by the ARM scientists from a location nearby the lidar. The lidar results show the +/- 1 sigma statistical error on each of the independent 75 m altitude bins of the data. This set of 4 comparisons was used to set and validate the calibration value which was then used for the complete data set. Section 4. A set of false color figures with up to 10 hours of specific humidity measurements are shown in each graph. Two days of measurements are shown on each page. These plots are crude representations of the data and permit a survey which indicates when the clouds were very low or where interesting events may occur in the results. These plots are prepared using the real time sequence plot program which has no smoothing in either the altitude or time (except that you are allowed to pick the integration time and time step. All of these plots were prepared with 15 minute integration and 5 minute time step. Section 5. A set of time sequence data for all of the extended observation periods are shown with a smoothing algorithm from the Matlab plotting library. Most of these data are integrated for 5 minutes and stepped at I minute intervals but several plots are shown with both 15 minute integration and 5 minute steps. The upper level on these data was selected and converted to the white background where the error in the specific humidity reached 25%. Section 6. The set of one hour integrated plots shown with up to 4 hours per page are provided- from the real time analysis snapshot program. The only difference in these plots and the real time display is that the plots are stopped at an altitude where the error appears to be too large for the data to contain any meaningful information.

Philbrick, C. Russell↗

Transmission of radiometer data from the Synchronous Meteorological Satellite

The Synchronous Meteorological Satellite uses a spin scanner radiometer which generates eight visual signals and two infrared signals. These signals are multiplexed and converted into a 28-Mbps data stream. This signal is transmitted to ground by quadriphase modulation at 1686.1 MHz. On the ground, the digital signal is reconstructed to an analog signal. To conserve bandwidth, an analog-to-digital converter with a nonlinear transfer function was used for the visual signals. The size of the quantization step was made proportional to the noise output of the scanner photomultiplier tube which increases as the square root of incident light. The radiometer data transmission link was simulated on a digital computer to determine the transfer function. Some results of the simulation are shown.

Davies, R. S.↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 2, Methods and Dose Calculations

This paper is part two of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Assumptions about equilibrium with long-lived parents are made for the 28 other radionuclides in these series lacking data. This paper describes the methods developed to group the collected data into source regions described in the Radiation Dose Assessment Resource (RADAR) dosimetric methodology. Methods for converting the various units of data published over 50 years into a standard form are developed and described. Often, meaningful values of uncertainty of measurements were not published so that variability in data sets is confounded with measurement uncertainty. A description of the methods developed to estimate variability is included in this paper. The data described in part one are grouped by gender and age to match the RADAR dosimetric phantoms. Within these phantoms, concentration values are grouped into source tissue regions by radionuclide, and they are imputed for source regions lacking tissue data. Radionuclide concentrations are then imputed for other phantoms’ source regions with missing concentration values, and the uncertainties of the imputed values are increased. The content concentrations of hollow organs are calculated, and activities are apportioned to the bone source regions using assumptions about each radionuclide’s bone-seeking behavior. The data sets are then ready to be used to estimate equivalent doses to target tissues from these source regions. The target tissues are then mapped to lists of tissues with International Commission on Radiation Protection (ICRP) tissue weighting factors, or they are mapped to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue weighting factors recommended in 1977, 1990, and 2007, are calculated from tissue and organ equivalent doses.

59 BASIC BIOLOGICAL SCIENCES↗

Raw tensiometer soil matric potential data, from Oct 2017-Jun 2020 in Manaus, Brazil

This data package contains raw output from two Campbell Scientific CR1000 data loggers each connected to three UMS T4e tensiometer sensors in Manaus, Brazil. Tensiometers at each data logger location were installed to depths of 10 cm, 20 cm and 50 cm below the ground surface for the purpose of measuring soil matric potential at each depth. “Station 3” tensiometers were installed at approximately 2°36'31.68"S, 60°12'34.70"W. “Station 4” tensiometers were installed at approximately 2°36'32.46"S, 60°12'34.92"W. The files “tensio3.edit.202109.csv” and “tensio4.edit.202109.csv” contain raw data (with invalid data removed). A text editor will be required to view the raw files in .csv (comma-separated values) format. Data processing was limited to: 1) Editing column headers for clarity; 2) Applying a correction that converts voltage read by the data loggers to pressure units (kPa); 3) removing all data greater than 50 kPa and less than -115 kPa; 4) Adding columns entitled “Caution.10cm”, “Caution.20cm” and “Caution.50cm” that contains values of either “NA” or “Caution”, the latter of which is applied when data exceeds the manufacturer reported data validity range of less than -85 kPa to suggest use of these data with caution; 5) Adding columns entitled “Invalid.10cm”, “Invalid.20cm”, and “Invalid.50cm” that contains values of either “NA” or “Invalid”, the latter of which is applied when data accuracy is deemed compromised due to the introduction of air bubbles into the instrument. Data marked “Invalid” may still indicate general trends of wet/high matric potential and dry/low matric potential, but values are inaccurate and dry/low matric potential values are likely not low enough. Wet/high matric potential values are likely to be more accurate than dry/low matric potential values; 6) Data format changed from .dat to .csv. This research was performed as a part of the NGEE Tropics project, which aims to advance model predictions of tropical forest carbon cycle responses to a changing climate over the 21st Century.

54 ENVIRONMENTAL SCIENCES↗

Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common data format (imzML) and a public data repository can contribute to more reliability and transparency of MS imaging studies.

Environmental Molecular Sciences Laboratory↗

A Modified Triples Algorithm for Flush Air Data Systems that Allows a Variety of Pressure Port Configurations

Air Data Systems (FADS) are becoming more prevalent on re-entry vehicles, as evi- denced by the Mars Science Laboratory and the Orion Multipurpose Crew Vehicle. A FADS consists of flush-mounted pressure transducers located at various locations on the fore-body of a flight vehicle or the heat shield of a re-entry capsule. A pressure model converts the pressure readings into useful air data quantities. Two algorithms for converting pressure readings to air data have become predominant- the iterative Least Squares State Estimator (LSSE) and the Triples Algorithm. What follows herein is a new algorithm that takes advantage of the best features of both the Triples Algorithm and the LSSE. This approach employs the potential flow model and strategic differencing of the Triples Algorithm to obtain the defective flight angles; however, the requirements on port placement are far less restrictive, allowing for configurations that are considered optimal for a FADS.

Millman, Daniel R.↗

Petrologic model of the northern Mississippi Embayment based on satellite magnetic and ground-based geophysical data

A petrologic model of the northern Mississippi Embayment, derived from gravity, seismic and rift data, is evaluated by converting the model to a magnetization model which is compared with satellite magnetic anomaly models. A magnetization contrast of approximately -0.54 A/m, determined from the petrologic model of the embayment compares favorably to values of -0.62 A/m and -0.45 A/m from a Magsat United States Apparent Magnetization Contrast Map and a published POGO magnetization contrast model, respectively. The petrologic model suggests that the magnetic anomaly low associated with the Mississippi Embayment may be largely due to the intrusion under non-oxidizing conditions of low Curie temperature gabbroic material at the base of the crust of the embayment. Near-surface mafic plutons, bordering the Mississippi Valley Graben, appear from aeromagnetic data to have higher magnetizations than the deeper gabbroic material; however, it is impossible to ascertain if this is due to compositional differences or similar material at shallower (lower temperature) depths. These results indicate that variations in the Curie temperatures of intrusions accompanying rifting may account for a large part of the wide range of magnetic anomalies associated with presently inactive rifts with normal heat flow.

Thomas, H. H.↗

Tests of NACA 0009, 0012, and 0018 Airfoils in the Full-Scale Tunnel

An investigation was conducted in the NACA full-scale wind tunnel to determine the aerodynamic characteristics of the NACA 0009, 0012, and 0018 airfoils, with the ultimate purpose of providing data to be used as a basis for comparison with other wind-tunnel data, mainly in the study of scale and turbulence effects. Three symmetrical 6 by 36-foot rectangular airfoils were used. The Reynolds number range for minimum drag was form 1,800,000 to 7,000,000 and for maximum lift, from 1,700,000 to 4,500,000. The effect of rounded tips was determined for each of the airfoils. Tests were also made of the NACA 0012 airfoil equipped with a 0.20c full-span split flap hinged at 0.80c. Tuft surveys were included to show the progressive breakdown of flow near maximum lift. Momentum surveys were made in conjunction with force measurements at zero lift as an aid in converting force-test data to section coefficients.

Goett, Harry J↗

Experiences From NASA/Langley's DMSS Project

There is a trend in institutions with high performance computing and data management requirements to explore mass storage systems with peripherals directly attached to a high speed network. The Distributed Mass Storage System (DMSS) Project at the NASA Langley Research Center (LaRC) has placed such a system into production use. This paper will present the experiences, both good and bad, we have had with this system since putting it into production usage. The system is comprised of: 1) National Storage Laboratory (NSL)/UniTree 2.1, 2) IBM 9570 HIPPI attached disk arrays (both RAID 3 and RAID 5), 3) IBM RS6000 server, 4) HIPPI/IPI3 third party transfers between the disk array systems and the supercomputer clients, a CRAY Y-MP and a CRAY 2, 5) a "warm spare" file server, 6) transition software to convert from CRAY's Data Migration Facility (DMF) based system to DMSS, 7) an NSC PS32 HIPPI switch, and 8) a STK 4490 robotic library accessed from the IBM RS6000 block mux interface. This paper will cover: the performance of the DMSS in the following areas: file transfer rates, migration and recall, and file manipulation (listing, deleting, etc.); the appropriateness of a workstation class of file server for NSL/UniTree with LaRC's present storage requirements in mind the role of the third party transfers between the supercomputers and the DMSS disk array systems in DMSS; a detailed comparison (both in performance and functionality) between the DMF and DMSS systems LaRC's enhancements to the NSL/UniTree system administration environment the mechanism for DMSS to provide file server redundancy the statistics on the availability of DMSS the design and experiences with the locally developed transparent transition software which allowed us to make over 1.5 million DMF files available to NSL/UniTree with minimal system outage

Source record↗

Simulation of arthroscopic surgery using MRI data

With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

Heller, Geoffrey↗