Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contact dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Early immune response to Coccidioides is characterized by robust neutrophil and fibrotic macrophage recruitment and differentiation

Coccidioidomycosis, or Valley fever, is an emerging respiratory disease caused by soil-dwelling fungi of the Coccidioides genus that is expected to spread from the southwest into the central U.S. by 2050. While 60% of infections are asymptomatic, the other 40% of patients experience a range of symptoms, from self-limiting pneumonia to life-threatening disseminated disease. The immunological events that underlie the progression to severe disease remain underdefined. Here, we probed the early immune response to Coccidioides using a high dose of an attenuated strain of Coccidioides posadasii in a mouse model of infection coupled with single-cell RNA sequencing. At 24 h post-infection, robust immune infiltration is detected in the lung, marked by high levels of inflammatory PD-L1 + neutrophils and fungal-contact-dependent pro-fibrotic Spp1 + macrophages. These findings elucidate the early dynamics of the host response to Coccidioides and provide a deeper understanding of host-pathogen interactions in the lung.

Coccidioides↗

ORNL Interim Progress Report on Static CIRFT Testing Curvature Data Update

Since the CIRFT tests reported in NUREG-7198 were generated, a number of factors that influence the recorded curvature measurement data were identified. In 2016, a data reanalysis task was undertaken to implement the lessons learned. This letter report provides the revised results of previous CIRFT tests, after implementing the following data reanalysis procedures: (A) experimental data smoothing and LVDT reset, (B) LVDT probe contact and sensor spacing correction for curvature data, and (C) LVDT probe dynamic vibration adjustment procedure development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Functionalization of Cathode–Electrolyte Interface with Ionic Liquids for High-Performance Quasi-Solid-State Lithium–Sulfur Batteries: A Low-Sulfur Loading Study

We introduce a quasi-solid-state electrolyte lithium-sulfur (Li–S) battery (QSSEB) based on a novel Li-argyrodite solid-state electrolyte (SSE), Super P–Sulfur cathode, and Li-anode. The cathode was prepared using a water-based carboxymethyl cellulose (CMC) solution and styrene butadiene rubber (SBR) as the binder while Li6PS5F0.5Cl0.5 SSE was synthesized using a solvent-based process, via the introduction of LiF into the argyrodite crystal structure, which enhances both the ionic conductivity and interface-stabilizing properties of the SSE. Ionic liquids (IL) were prepared using lithium bis(trifluoromethyl sulfonyl)imide (LiTFSI) as the salt, with pre-mixed pyrrolidinium bis(trifluoromethyl sulfonyl)imide (PYR) as solvent and 1,3-dioxolane (DOL) as diluent, and they were used to wet the SSE–electrode interfaces. The effect of IL dilution, the co-solvent amount, the LiTFSI concentration, the C rate at which the batteries are tested and the effect of the introduction of SSE in the cathode, were systematically studied and optimized to develop a QSSEB with higher capacity retention and cyclability. Interfacial reactions occurring at the cathode–SSE interface during cycling were also investigated using electrochemical impedance spectroscopy, cyclic voltammetry, and X-ray photoelectron spectroscopy supported by ab initio molecular dynamics simulations. This work offers a new insight into the intimate interfacial contacts between the SSE and carbon–sulfur cathodes, which are critical for improving the electrochemical performance of quasi-solid-state lithium–sulfur batteries.

25 ENERGY STORAGE↗

A molecular portrait of maternal sepsis from Byzantine Troy

Pregnancy complications are poorly represented in the archeological record, despite their importance in contemporary and ancient societies. While we excavated a Byzantine cemetery in Troy, we discovered calcified abscesses among a woman’s remains. Scanning electron microscopy of the tissue revealed ‘ghost cells’, resulting from dystrophic calcification, which preserved ancient maternal, fetal and bacterial DNA of a severe infection, likely chorioamnionitis. Gardnerella vaginalis and Staphylococcus saprophyticus dominated the abscesses. Phylogenomic analyses of ancient, historical, and contemporary data showed that G. vaginalis Troy fell within contemporary genetic diversity, whereas S. saprophyticus Troy belongs to a lineage that does not appear to be commonly associated with human disease today. We speculate that the ecology of S. saprophyticus infection may have differed in the ancient world as a result of close contacts between humans and domesticated animals. Our results highlight the complex and dynamic interactions with our microbial milieu that underlie severe maternal infections.

59 BASIC BIOLOGICAL SCIENCES↗

Lubrication and failure mechanisms of graphite fluoride films

An optical microscope, equipped with a vertical illuminator and two polaroid filters (one rotatable), was used to visually study 440C HT steel surfaces lubricated with rubbed graphite fluoride films. Friction and wear results were compared to visual observations as a function of sliding distance for films applied to three surface finishes - polished, sanded, and sand-blasted. In general, the lubricating process was one of initial deformation or wear of metallic asperities into flat plateaus and then the formation of thin, layer-like, dynamic films which sheared between the flats and eventually flowed through the contact area. Failure was due to depletion of the graphite fluoride with the subsequent formation of excessive powdery metallic debris that formed a heavy, powdery film on both the rider and disk surfaces.

Fusaro, R. L.↗

Evaluation of left ventricular assist device pump bladders cast from ion-sputtered polytetrafluorethylene mandrels

A highly thromboresistant blood contacting interface for use in implanatable blood pump is investigated. Biomaterials mechanics, dynamics, durability, surface morphology, and chemistry are among the critical consideration pertinent to the choice of an appropriate blood pump bladder material. The use of transfer cast biopolymers from ion beam textured surfaces is investigated to detect subtle variations in blood pump surface morphology using Biomer as the biomaterial of choice. The efficacy of ion beam sputtering as an acceptable method of fabricating textured blood interfaces is evaluated. Aortic grafts and left ventricular assist devices were implanted in claves; the blood interfaces were fabricated by transfer casting methods from ion beam textured polytetrafluorethylene mandrels. The mandrels were textured by superimposing a 15 micron screen mesh; ion sputtering conditions were 300 volts beam energy, 40 to 50 mA beam, and a mandrel to source distance of 25 microns.

Source record↗

High temperature ceramic interface study

Monolithic SiC and Si3N4 are susceptible to contact stress damage at static and sliding interfaces. Transformation-toughened zirconia (TTZ) was evaluated under sliding contact conditions to determine if the higher material fracture toughness would reduce the susceptibility to contact stress damage. Contact stress tests were conducted on four commercially available TTZ materials at normal loads ranging from 0.455 to 22.7 kg (1 to 50 pounds) at temperatures ranging from room temperature to 1204C (2200 F). Static and dynamic friction were measured as a function of temperature. Flexural strength measurements after these tests determined that the contact stress exposure did not reduce the strength of TTZ at contact loads of 0.455, 4.55, and 11.3 kg (1, 10, and 25 pounds). Prior testing with the lower toughness SiC and Si3N4 materials resulted in a substantial strength reduction at loads of only 4.55 and 11.3 kg (10 and 25 pounds). An increase in material toughness appears to improve ceramic material resistance to contact stress damage. Baseline material flexure strength was established and the stress rupture capability of TTZ was evaluated. Stress rupture tests determined that TTZ materials are susceptible to deformation due to creep and that aging of TTZ materials at elevated temperatures results in a reduction of material strength.

Lindberg, L. J.↗

Design and evaluation of high contact ratio gearing

Scoring test and surface fatigue tests were conducted on spur gears of a standard design and spur gears of a high contact ratio design. All testing was conducted in the Sikorsky 6-inch dynamic test facility at a speed of 8000 rpm using 23699 oil. Bulk gear temperatures were also recorded. The surface fatigue tests were run at Hertz stresses of 165 x 10 to the 7th power N/sq m and 145 x 10 to the 7th power N/sq m (240,000 and 210,000 psi), respectively.

Frint, Harold K.↗

Dynamic condensation model of rolling droplets for high-performance heat transfer

Condensation is a critical process during vapor-liquid phase change in relation to heat transfer. To achieve a high heat transfer coefficient, the classical model for dropwise condensation requires a low contact angle and low contact angle hysteresis, failing to align with experimental observations on a hydrophobic and slippery quasi-liquid surface (QLS). Here, we report a dynamic condensation model that incorporates high-frequency condensate removal by emphasizing the role of timescale during droplet growth and shedding. Our model agrees well with the experimental result that a surface with high contact angle and low contact angle hysteresis promotes condensation, particularly during rolling-propelled condensate removal. Particle image velocimetry reveals that rolling droplets on a hydrophobic QLS exhibit 4-fold higher shedding speeds than the sliding droplets on a hydrophilic QLS, leading to significant heat transfer enhancement. This work deepens our theoretical understanding of condensation heat transfer and provides advanced physics-informed design rationales for water and energy systems.

42 ENGINEERING↗

The Rutile (110)-Water Interface: A comment on "Structure and Dynamics of Liquid Water on Rutile TiO2(110)" by L.-M. Liu, C. Zhang, G. Thornton and A. Michaelides

The (110) surface of rutile ( -TiO2) in contact with water is one of the most technologically-important and scientifically-investigated interfaces that exists. Liu and coworkers1 (hereafter Liu1) expanded on an excellent review of water-titania interfaces2, by conducting extensive static density functional theory (DFT) and DFT molecular dynamics (DFT-MD) investigations of rutile (110) using a range of cell configurations and DFT functionals. We agree with their DFT calculations of the influence of crystal slab thickness on water sorption energies, but find some of their major conclusions unwarranted or overstated, namely a.) that there is no dissociation of first-layer sorbed water at ~300K; b.) that translational diffusion of water molecules in contact with the surface approaches that of bulk liquid water ; and c.) that second layer water structuring and hydrogen bonding to surface oxygens are weak. We present published evidence not cited by Liu1 that challenge these assertions.

08 HYDROGEN↗

Contact detection acceleration in pebble flow simulation for pebble bed reactor systems

Pebble flow simulation plays an important role in the steady state and transient analysis of thermal-hydraulics and neutronics for Pebble Bed Reactors (PBR). The Discrete Element Method (DEM) and the modified Molecular Dynamics (MD) method are widely used to simulate the pebble motion to obtain the distribution of pebble concentration, velocity, and maximum contact stress. Although DEM and MD present high accuracy in the pebble flow simulation, they are quite computationally expensive due to the large quantity of pebbles to be simulated in a typical PBR and the ubiquitous contacts and collisions between neighboring pebbles that need to be detected frequently in the simulation, which greatly restricted their applicability for large scale PBR designs such as PBMR400. Since the contact detection accounts for more than 60% of the overall CPU time in the pebble flow simulation, the acceleration of the contact detection can greatly enhance the overall efficiency. In the present work, based on the design features of PBRs, two contact detection algorithms, the basic cell search algorithm and the bounding box search algorithm are investigated and applied to pebble contact detection. The influence from the PBR system size, core geometry and the searching cell size on the contact detection efficiency is presented. Our results suggest that for present PBR applications, the bounding box algorithm is less sensitive to the aforementioned effects and has superior performance in pebble contact detection compared with basic cell search algorithm. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Probing the Impact of Vacancy Diffusion on Void Dynamics at the Lithium Metal–Solid Electrolyte Interface

Lithium (Li) metal-based solid-state batteries (SSBs) are considered promising candidates for next-generation energy storage due to their superior energy density and enhanced safety compared to conventional Li-ion systems. However, their practical application is limited by challenges such as void formation at the Li-solid electrolyte (SE) interface, which disrupts ion transport and accelerates interfacial degradation. This work investigates how the coupled effects of electro-dissolution kinetics and surface diffusion at the Li metal surface govern the evolution of interfacial morphology during stripping. This work examines the influence of three distinct surface diffusion modes, which are terrace diffusion, step diffusion, and interlayer diffusion, on maintaining interfacial stability. In addition, how the dominant surface diffusion mechanism can overcome the contact loss due to high reaction kinetics is explored. Furthermore, the roughness of the Li metal anode surface is quantified, and the influence of different diffusion mechanisms on the evolution of the dynamic solid–solid interface is examined. The critical role of temperature in enhancing Li surface diffusivity and expanding the regime of stable contact is highlighted. By identifying distinct regimes of interface stability, this study analyzes how non-uniform electrochemical dynamics dictate void morphology evolution and interfacial contact. These insights offer guiding principles for engineering robust Li–SE interfaces in SSBs.

lithium metal anode↗

Load-Displacement Relation and Gap Distribution Between Rough Surfaces: Partial Differential Equations Approach

We develop a theoretical model to predict the load-displacement relation and probability density function for gaps between contacting rough surfaces. We derive partial differential equations from the previous model (Joe et al., 2018), and extend them to the non-adhesive contact problem. The predictions of the present theory are compared with numerical results using the Green's function molecular dynamics algorithm, and a good agreement is obtained.

adhesion↗

Presto 4.14 user s guide.

Presto is a three-dimensional transient dynamics code with a versatile element library, nonlinear material models, large deformation capabilities, and contact. It is built on the SIERRA Framework [1, 2]. SIERRA provides a data management framework in a parallel computing environment that allows the addition of capabilities in a modular fashion. Contact capabilities are parallel and scalable. The Presto 4.14 User's Guide provides information about the functionality in Presto and the command structure required to access this functionality in a user input file. This document is divided into chapters based primarily on functionality. For example, the command structure related to the use of various element types is grouped in one chapter; descriptions of material models are grouped in another chapter. The input and usage of Presto is similar to that of the code Adagio [3]. Adagio is a three-dimensional quasi-static code with a versatile element library, nonlinear material models, large deformation capabilities, and contact. Adagio, like Presto, is built on the SIERRA Framework [1]. Contact capabilities for Adagio are also parallel and scalable. A significant feature of Adagio is that it offers a multilevel, nonlinear iterative solver. Because of the similarities in input and usage between Presto and Adagio, the user's guides for the two codes are structured in the same manner and share common material. (Once you have mastered the input structure for one code, it will be easy to master the syntax structure for the other code.) To maintain the commonality between the two user's guides, we have used a variety of techniques. For example, references to Adagio may be found in the Presto user's guide and vice versa, and the chapter order across the two guides is the same. On the other hand, each of the two user's guides is expressly tailored to the features of the specific code and documents the particular functionality for that code. For example, though both Presto and Adagio have contact functionality, the content of the chapter on contact in the two guides differs. Important references for both Adagio and Presto are given in the references section at the end of this chapter. Adagio was preceded by the codes JAC and JAS3D; JAC is described in Reference 4; JAS3D is described in Reference 5. Presto was preceded by the code Pronto3D. Pronto3D is described in References 6 and 7. Some of the fundamental nonlinear technology used by both Presto and Adagio are described in References 8, 9, and 10. Currently, both Presto and Adagio use the Exodus II database and the XDMF database; Exodus II is more commonly used than XDMF. (Other options may be added in the future.) The Exodus II database format is described in Reference 11, and the XDMF database format is described in Reference 12. Important information about contact is provided in the reference document for ACME [13]. ACME is a third-party library for contact. One of the key concepts for the command structure in the input file is a concept referred to as scope. A detailed explanation of scope is provided in Section 1.2. Most of the command lines in Chapter 2 are related to a certain scope rather than to some particular functionality.

97 MATHEMATICS AND COMPUTING↗

Exploring Anomalous Polarization Dynamics in Organometallic Halide Perovskites

Organometallic halide perovskites (OMHPs) have attracted broad attention as prospective materials for optoelectronic applications. Among the many anomalous properties of these materials, of special interest are the ferroelectric properties including both classical and relaxor-like components, as a potential origin of slow dynamics, field enhancement, and anomalous mobilities. Here, ferroelectric properties of the three representative OMHPs are explored, including FAPb x Sn 1–x I 3 (x = 0, x = 0.85) and FA 0.85 MA 0.15 PbI 3 using band excitation piezoresponse force microscopy and contact mode Kelvin probe force microscopy, providing insight into long- and short-range dipole and charge dynamics in these materials and probing ferroelectric density of states. Furthermore, second-harmonic generation in thin films of OMHPs is observed, providing a direct information on the noncentrosymmetric polarization in such materials. Overall, the data provide strong evidence for the presence of ferroelectric domains in these systems; however, the domain dynamics is suppressed by fast ion dynamics. These materials hence present the limit of ferroelectric materials with spontaneous polarization dynamically screened by ionic and electronic carriers.

36 MATERIALS SCIENCE↗

Validation of Laser-Induced Fluorescent Photogrammetric Targets on Membrane Structures

The need for static and dynamic characterization of a new generation of inflatable space structures requires the advancement of classical metrology techniques. A new photogrammetric-based method for non-contact ranging and surface profiling has been developed at NASA Langley Research Center (LaRC) to support modal analyses and structural validation of this class of space structures. This full field measurement method, known as Laser-Induced Fluorescence (LIF) photogrammetry, has previously yielded promising experimental results. However, data indicating the achievable measurement precision had not been published. This paper provides experimental results that indicate the LIF-photogrammetry measurement precision for three different target types used on a reflective membrane structure. The target types were: (1) non-contact targets generated using LIF, (2) surface attached retro-reflective targets, and (3) surface attached diffuse targets. Results from both static and dynamic investigations are included.

Jones, Thomas W.↗

Linear and nonlinear instability in vertical counter-current laminar gas-liquid flows

We consider the genesis and dynamics of interfacial instability in vertical gas-liquid flows, using as a model the two-dimensional channel flow of a thin falling film sheared by counter-current gas. The methodology is linear stability theory (Orr-Sommerfeld analysis) together with direct numerical simulation of the two-phase flow in the case of nonlinear disturbances. We investigate the influence of two main flow parameters on the interfacial dynamics, namely the film thickness and pressure drop applied to drive the gas stream. To make contact with existing studies in the literature, the effect of various density contrasts is also examined. Energy budget analyses based on the Orr-Sommerfeld theory reveal various coexisting unstable modes (interfacial, shear, internal) in the case of high density contrasts, which results in mode coalescence and mode competition, but only one dynamically relevant unstable interfacial mode for low density contrast. A study of absolute and convective instability for low density contrast shows that the system is absolutely unstable for all but two narrow regions of the investigated parameter space. Direct numerical simulations of the same system (low density contrast) show that linear theory holds up remarkably well upon the onset of large-amplitude waves as well as the existence of weakly nonlinear waves. For high density contrasts, corresponding more closely to an air-water-type system, linear stability theory is also successful at determining the most-dominant features in the interfacial wave dynamics at early-to-intermediate times. Nevertheless, the short waves selected by the linear theory undergo secondary instability and the wave train is no longer regular but rather exhibits chaotic motion. The same linear stability theory predicts when the direction of travel of the waves changes — from downwards to upwards. We outline the practical implications of this change in terms of loading and flooding. The change in direction of the wave propagation is represented graphically in terms of a flow map based on the liquid and gas flow rates and the prediction carries over to the nonlinear regime with only a small deviation.

42 ENGINEERING↗

Structure and Dynamics of the Liver Receptor Homolog 1–PGC1 α Complex

Peroxisome proliferator-activated gamma coactivator 1-α (PGC1α) regulates energy metabolism by directly interacting with transcription factors to modulate gene expression. Among the PGC1α binding partners is liver receptor homolog 1 (LRH-1; NR5A2), an orphan nuclear hormone receptor that controls lipid and glucose homeostasis. Although PGC1α is known to bind and activate LRH-1, mechanisms through which PGC1α changes LRH-1 conformation to drive transcription are unknown. Here, we used biochemical and structural methods to interrogate the LRH-1–PGC1α complex. Purified, full-length LRH-1, as well as isolated ligand binding domain, bound to PGC1α with higher affinity than to the coactivator, nuclear receptor coactivator-2 (Tif2), in coregulator peptide recruitment assays. We present the first crystal structure of the LRH-1–PGC1α complex, which depicts several hydrophobic contacts and a strong charge clamp at the interface between these partners. In molecular dynamics simulations, PGC1α induced correlated atomic motion throughout the entire LRH-1 activation function surface, which was dependent on charge-clamp formation. In contrast, Tif2 induced weaker signaling at the activation function surface than PGC1α but promoted allosteric signaling from the helix 6/β-sheet region of LRH-1 to the activation function surface. These studies are the first to probe mechanisms underlying the LRH-1–PGC1α interaction and may illuminate strategies for selective therapeutic targeting of PGC1α-dependent LRH-1 signaling pathways.

60 APPLIED LIFE SCIENCES↗