Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

An initial measurement of a fast neutral spectrum for ion cyclotron range of frequency heated plasma using two-channel compact neutral particle analyzers in KSTAR

The accurate measurement of fast neutral particles from high energy ion tails is very important since it is a measure of ion cyclotron range of frequency (ICRF) or neutral beam (NB) ion heating. In KSTAR, fast neutral measurements have been carried out using a compact neutral particle analyzer based on the silicon photo diode since 2010. As a result, the fast neutral spectrum was observed consistent with the ion temperature, diamagnetic energy, and neutron flux in 2011. However, there was fast neutral count beyond the injected neutral beam energy in NB-only heating. Since it is difficult to expect the count unless the temperature is high enough to diffuse the fast ions beyond the beam energy it was required to identify what it is. During the 2012 campaign, the two-channel diode detectors with and without a particle stopper were used to distinguish fast neutral counts and other counts by a hard X-ray or neutrons. As a result, it was confirmed that the high energy component beyond the beam energy originated from a hard X-ray or neutrons. Finally, it was observed that faster neutrals are generated by ICRF heating and enhanced by electron cyclotron heating compared to NB-only heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon technology compatible photonic molecules for compact optical signal processing

Photonic molecules (PMs) based on multiple inner coupled microring resonators allow to surpass the fundamental constraint between the total quality factor (Q{sub T}), free spectral range (FSR), and resonator size. In this work, we use a PM that presents doublets and triplets resonance splitting, all with high Q{sub T}. We demonstrate the use of the doublet splitting for 34.2 GHz signal extraction by filtering the sidebands of a modulated optical signal. We also demonstrate that very compact optical modulators operating 2.75 times beyond its resonator linewidth limit may be obtained using the PM triplet splitting, with separation of ∼55 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design approach for the development of a cryomodule for compact crab cavities for Hi-Lumi LHC

A prototype Superconducting RF (SRF) cryomodule, comprising multiple compact crab cavities is foreseen to realise a local crab crossing scheme for the “Hi-Lumi LHC”, a project launched by CERN to increase the luminosity performance of LHC. A cryomodule with two cavities will be initially installed and tested on the SPS drive accelerator at CERN to evaluate performance with high-intensity proton beams. A series of boundary conditions influence the design of the cryomodule prototype, arising from; the complexity of the cavity design, the requirement for multiple RF couplers, the close proximity to the second LHC beam pipe and the tight space constraints in the SPS and LHC tunnels. As a result, the design of the helium vessel and the cryomodule has become extremely challenging. This paper assesses some of the critical cryogenic and engineering design requirements and describes an optimised cryomodule solution for the evaluation tests on SPS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent achievements in the Hamiltonian treatment of the dynamics and motion of compact binaries in general relativity

The current knowledge in the post-Newtonian (PN) dynamics and motion of non-spinning and spinning compact binaries will be presented based on the Arnowitt-Deser-Misner Hamiltonian approach to general relativity. The presentation will cover the binary dynamics with non-spinning components up to the 4PN order and for spinning binaries up to the next-to-next-to-leading order in the spin-orbit and spin-spin couplings. Radiation reaction will be treated for both non-spinning and spinning binaries. Explicit analytic expressions for the motion will be given, innermost stable circular orbits will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron

The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C{sup 4+} ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8–10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C{sup 4+}, for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

07 ISOTOPE AND RADIATION SOURCES↗

Study of instability formation and EUV emission in thin liners driven with a compact 250 kA, 150 ns linear transformer driver

A compact linear transformer driver, capable of producing 250 kA in 150 ns, was used to study instability formation on the surface of thin liners. In the experiments, two different materials, Cu and Ni, were used to study the effect of the liner's resistivity on formation and evolution of the instabilities. The dimensions of the liners used were 7 mm height, 1 mm radius, and 3 μm thickness. Laser probing and time resolved extreme ultraviolet (EUV) imaging were implemented to diagnose instability formation and growth. Time-integrated EUV spectroscopy was used to study plasma temperature and density. A constant expansion rate for the liners was observed, with similar values for both materials. Noticeable differences were found between the Cu and Ni instability growth rates. The most significant perturbation in Cu rapidly grows and saturates reaching a limiting wavelength of the order of the liner radius, while the most significant wavelength in Ni increases slowly before saturating, also at a wavelength close to the liner radius. Evidence suggests that the instability observed is the well-known m = 0 MHD instability. However, upon comparing the instability evolution of Cu and Ni, the importance of the resistivity on the seeding mechanism becomes evident. A comparison of end-on and side-on EUV emission possible indicates the formation of precursor plasma, where it has been estimated using EUV spectroscopy that the precursor plasma temperature is approximately 40 eV with ion density of order 10{sup 19} cm{sup −3}, for both materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact 180-kV Marx generator triggered in atmospheric air by femtosecond laser filaments

We developed a compact Marx generator triggered in atmospheric air by a single femtosecond laser beam undergoing filamentation. Voltage pulses of 180 kV could be generated with a subnanosecond jitter. The same laser beam was also used to initiate simultaneously guided discharges up to 21 cm long at the output of the generator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monochromatic short pulse laser produced ion beam using a compact passive magnetic device

High-intensity laser accelerated protons and ions are emerging sources with complementary characteristics to those of conventional sources, namely high charge, high current, and short bunch duration, and therefore can be useful for dedicated applications. However, these beams exhibit a broadband energy spectrum when, for some experiments, monoenergetic beams are required. We present here an adaptation of conventional chicane devices in a compact form (10 cm × 20 cm) which enables selection of a specific energy interval from the broadband spectrum. This is achieved by employing magnetic fields to bend the trajectory of the laser produced proton beam through two slits in order to select the minimum and maximum beam energy. The device enables a production of a high current, short duration source with a reproducible output spectrum from short pulse laser produced charged particle beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A compact, multichannel, and low noise arbitrary waveform generator

A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A plateau in the sensitivity of a compact optically pumped atomic magnetometer

In a compact optically pumped atomic magnetometer (OPAM), there is a plateau in the sensitivity where the dependence of the sensitivity on pumping power is small compared with that predicted by the uniform polarization model. The mechanism that generates this plateau was explained by numerical analysis. The distribution of spin polarization in the alkali metal cell of an OPAM was modeled using the Bloch equation incorporating a diffusion term and an equation for the attenuation of the pump beam. The model was well-fitted to the experimental results for a module with a cubic cell with 20 mm sides and pump and probe beams with 8 mm diameter. On the plateau, strong magnetic response was generated at the regions that were not illuminated directly by the intense pump beam, while at the same time spin polarization as large as 0.5 was maintained due to diffusion of the spin-polarized atoms. Thus, the sensitivity of the magnetometer monitored with a probe beam decreases only slightly with increasing pump beam intensity because the spin polarization under an intense pump beam is saturated. This plateau, which is characteristic of this type of magnetometer using a narrow pump and probe beams, can be used in arrays of magnetometers because it enables stable operation with little sensitivity fluctuation from changes in pump beam power.

36 MATERIALS SCIENCE↗

Monolithic integration of a quantum emitter with a compact on-chip beam-splitter

A fundamental component of an integrated quantum optical circuit is an on-chip beam-splitter operating at the single-photon level. Here, we demonstrate the monolithic integration of an on-demand quantum emitter in the form of a single self-assembled InGaAs quantum dot (QD) with a compact (>10 μm), air clad, free standing directional coupler acting as a beam-splitter for anti-bunched light. The device was tested by using single photons emitted by a QD embedded in one of the input arms of the device. We verified the single-photon nature of the QD signal by performing Hanbury Brown-Twiss measurements and demonstrated single-photon beam splitting by cross-correlating the signal from the separate output ports of the directional coupler.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A compact chaotic laser device with a two-dimensional external cavity structure

We propose a compact chaotic laser device, which consists of a semiconductor laser and a two-dimensional (2D) external cavity for delayed optical feedback. The overall size of the device is within 230 μm × 1 mm. A long time delay sufficient for chaos generation can be achieved with the small area by the multiple reflections at the 2D cavity boundary, and the feedback strength is controlled by the injection current to the external cavity. We experimentally demonstrate that a variety of output properties, including chaotic output, can be selectively generated by controlling the injection current to the external cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact micro-wave synthesizer for transportable cold-atom interferometers

We present the realization of a compact micro-wave frequency synthesizer for an atom interferometer based on stimulated Raman transitions, applied to transportable inertial sensing. Our set-up is intended to address the hyperfine transitions of {sup 87}Rb at 6.8 GHz. The prototype is evaluated both in the time and the frequency domain by comparison with state-of-the-art frequency references developed at Laboratoire national de métrologie et d'essais−Systémes de référence temps espace (LNE-SYRTE). In free-running mode, it features a residual phase noise level of −65 dB rad{sup 2} Hz{sup −1} at 10 Hz offset frequency and a white phase noise level in the order of −120 dB rad{sup 2} Hz{sup −1} for Fourier frequencies above 10 kHz. The phase noise effect on the sensitivity of the atomic interferometer is evaluated for diverse values of cycling time, interrogation time, and Raman pulse duration. To our knowledge, the resulting contribution is well below the sensitivity of any demonstrated cold atom inertial sensors based on stimulated Raman transitions. The drastic improvement in terms of size, simplicity, and power consumption paves the way towards field and mobile operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of silicon photomultipliers as compact light readout systems for gamma-ray spectroscopy applications in fusion plasmas

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr{sub 3} crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%–4% in the energy range E{sub γ} = 3–5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and initial characterization of a compact, ultra high vacuum compatible, low frequency, tilt accelerometer

A compact tilt accelerometer with high sensitivity at low frequency was designed to provide low frequency corrections for the feedback signal of the Advanced Laser Interferometer Gravitational Wave Observatory active seismic attenuation system. It has been developed using a Tungsten Carbide ceramic knife-edge hinge designed to avoid the mechanical 1/f noise believed to be intrinsic in polycrystalline metallic flexures. Design and construction details are presented; prototype data acquisition and control limitations are discussed. The instrument's characterization reported here shows that the hinge is compatible with being metal-hysteresis-free, and therefore also free of the 1/f noise generated by the dislocation Self-Organized Criticality in the metal. A tiltmeter of this kind will be effective to separate the ground tilt component from the signal of horizontal low frequency seismometers, and to correct the ill effects of microseismic tilt in advanced seismic attenuation systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of one-dimensional stagnation solutions to three-dimensional simulation of compact wire array in absence of radiation

We investigate the stagnation phase of a three-dimensional (3D), magnetohydrodynamic simulation of a compact, tungsten wire-array Z pinch, under the simplifying assumption of negligible radiative loss. In particular, we address the ability of one-dimensional (1D) analytic theory to describe the time evolution of spatially averaged plasma properties from 3D simulation. The complex fluid flows exhibited in the stagnated plasma are beyond the scope of 1D theory and result in centrifugal force as well as enhanced thermal transport. Despite these complications, a 1D homogeneous (i.e., shockless) stagnation solution can capture the increase of on-axis density and pressure during the initial formation of stagnated plasma. Later, when the stagnated plasma expands outward into the imploding plasma, a 1D shock solution describes the decrease of on-axis density and pressure, as well as the growth of the shock accretion region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thomson scattering diagnostic system design for the Compact Toroidal Hybrid experiment

A new Thomson scattering system using standard commercially available components has been designed for the non-axisymmetric plasmas of the Compact Toroidal Hybrid (CTH). The beam, generated by a frequency doubled Continuum PL DLS 2 J Nd:YAG laser, is passed vertically through an entrance Brewster window and an aperturing baffle system to minimize the stray laser light that could enter the collection optics. The beam line has been designed with an 8 m propagation distance to the mid-plane of the CTH device with the beam diameter kept less than 3 mm inside the plasma volume. The beam exits the vacuum system through another Brewster window and enters a beam dump, again to minimize the stray light in the vacuum chamber. Light collection, spectral processing, and signal detection are accomplished with an f/#∼ 1 aspheric lens, a commercially available Holospec f/1.8 spectrometer, and an Andor iStar DH740-18U-C3 image intensified camera. Spectral rejection of stray laser light, if needed, can be performed with the use of an optional interference filter at the spectrometer input. The system has been developed for initial single point measurements of plasmas with core electron temperatures of approximately 20–300 eV and densities of 5 × 10{sup 18} to 5 × 10{sup 19} m{sup −3} dependent upon operational scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mean field limit for bosons with compact kernels interactions by Wigner measures transportation

We consider a class of many-body Hamiltonians composed of a free (kinetic) part and a multi-particle (potential) interaction with a compactness assumption on the latter part. We investigate the mean field limit of such quantum systems following the Wigner measures approach. We prove in particular the propagation of these measures along the flow of a nonlinear (Hartree) field equation. This enhances and complements some previous results of the same type shown in Z. Ammari and F. Nier and Fröhlich et al. [“Mean field limit for bosons and propagation of Wigner measures,” J. Math. Phys. 50(4), 042107 (2009); Z. Ammari and F. Nier and Fröhlich et al., “Mean field propagation of Wigner measures and BBGKY hierarchies for general bosonic states,” J. Math. Pures Appl. 95(6), 585–626 (2011); Z. Ammari and F. Nier and Fröhlich et al., “Mean-field- and classical limit of many-body Schrödinger dynamics for bosons,” Commun. Math. Phys. 271(3), 681–697 (2007)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗